All MIBs › CISCO-CALL-TRACKER-MIB
Organization: Cisco Systems, Inc.
Last Updated: 2005-04-12
Category: Cisco Devices, Telephony and VoIP
Description: Tracks active and historical dial calls including duration and status on Cisco access servers.
Start monitoring vendor-neutral, standards-based MIB, any SNMPv3-capable network device (SNMP engine identity/boot/clock status) with a free 30-day trial of IPNetwork Monitor. Import MIBs, browse SNMP OIDs, create custom SNMP monitors, configure alerts, and monitor any SNMP-enabled network device from a single console.
What Is CISCO-CALL-TRACKER-MIB?
CISCO-CALL-TRACKER-MIB is a Cisco Systems, Inc. proprietary MIB tracking the progress and status of a data call from the hardware layer through the application/service layer on Cisco Network Access Server (NAS) equipment. Its active-call table, keyed by call ID, records setup/connection/physical-layer-ready/service-up/user-validation times, origin, service type, user ID/IP address/subnet mask, accounting session ID, call category, initial RX/TX rate, and the specific resource slot/port/entry/DS1 handling the call. As a performance/status MIB it lets an administrator trace an individual dial-in call's full setup timeline to diagnose slow call establishment. It is deployed on Cisco Systems Network Access Server (NAS) equipment. Engineers can download the CISCO-CALL-TRACKER-MIB file directly to load it into their MIB browser.
IPNetwork Monitor allows you to monitor SNMP objects defined in CISCO-CALL-TRACKER-MIB. Use the built-in SNMP Monitoring Browser to explore available variables, view their current values and descriptions, and select the objects you want to monitor. You can then create SNMP monitors, configure thresholds, and receive alerts when monitored values change.
Supported Devices
- Cisco Systems Network Access Server (NAS) equipment
Monitoring Examples
An administrator checks cctActiveConnectionTime against cctActiveSetupTime to diagnose slow call establishment on a Cisco Network Access Server.
What Can Be Monitored
- per-call setup timeline and resource assignment
This MIB depends on
Related MIBs
Imported Objects
From CISCO-SMI
| ciscoMgmt | OBJECT-IDENTITY |
From DIAL-CONTROL-MIB
| AbsoluteCounter32 |
From SNMPv2-CONF
| MODULE-COMPLIANCE | |
| NOTIFICATION-GROUP | |
| OBJECT-GROUP |
From SNMPv2-SMI
| Gauge32 | |
| Integer32 | |
| IpAddress | |
| MODULE-IDENTITY | |
| NOTIFICATION-TYPE | |
| OBJECT-TYPE | |
| Unsigned32 |
From SNMPv2-TC
| DisplayString | |
| TEXTUAL-CONVENTION | |
| TimeStamp | |
| TruthValue |
How to Use in IPNetwork Monitor
Example using cctActiveTableNumberEntries OID:
OIDs
| OID symbolic | OID numeric | Type | Access | Description |
|---|---|---|---|---|
| cctActive | 1.3.6.1.4.1.9.9.163.1.2 | |||
| STR cctActiveAccountingSessionId | 1.3.6.1.4.1.9.9.163.1.2.3.1.12 | DisplayString | read-only | Accounting session identification assigned to this call by AAA. The session ID is sent by AAA to RADIUS as the Acct-Session-Id attribute or TACACS+ as the task_id. If no accounting session ID is assigned, the value is a null string. |
| CCT cctActiveCallCategory | 1.3.6.1.4.1.9.9.163.1.2.3.1.13 | CctCallCategory | read-only | The call category or type |
| STR cctActiveCalledPartyId | 1.3.6.1.4.1.9.9.163.1.2.3.1.22 | DisplayString | read-only | The called telephone number for this call. For calls answered by the system, this corresponds to the Dialed Number Identification (DNIS). For calls originated by the system, this is the destination number. If not available this is a zero-length string. |
| CCT cctActiveCallId | 1.3.6.1.4.1.9.9.163.1.2.3.1.1 | CctCallId | not-accessible | Represents a Call Identifier. The call identifier is a monotonically increasing unsigned integer which uniquely identifies the call within the system. The Call ID is represented as an unsigned 32-bit integer. After 4,294,967,295 calls, the ID will wrap and the 4,294,967,296th call will receive the next smallest available id starting from 1. Zero is not a valid value. |
| STR cctActiveCallingPartyId | 1.3.6.1.4.1.9.9.163.1.2.3.1.23 | DisplayString | read-only | The calling telephone number for this call. For calls answered by the system, this corresponds to the calling identification (CLID). For calls originated by the system, this is the number associated with the device. For the interworking call, this object contains the translated calling party number if there is a translation rule is associated with dial plan for making this outgoing call. If not available this is a zero-length string. |
| CCT cctActiveCallSignalingType | 1.3.6.1.4.1.9.9.163.1.2.3.1.28 | CctCallSigType | read-only | Signaling type used to setup the call. |
| NUM cctActiveChargedUnits | 1.3.6.1.4.1.9.9.163.1.2.3.1.25 | AbsoluteCounter32 | read-only | The number of charged units for this connection. For incoming calls or if charging information is not supplied by the switch, the value of this object will be zero. |
| TIM cctActiveConnectionTime | 1.3.6.1.4.1.9.9.163.1.2.3.1.4 | TimeStamp | read-only | Value of sysUpTime when the system connected the call. |
| cctActiveEntry | 1.3.6.1.4.1.9.9.163.1.2.3.1 | not-accessible | The information regarding a single call. Entries are created when a setup request is first received by the system. Entries are removed when a call is terminated or rejected. A corresponding entry is created in the cctHistoryTable. | |
| I32 cctActiveEntryChannel | 1.3.6.1.4.1.9.9.163.1.2.3.1.21 | Integer32 | read-only | The channel or timeslot within the cctActiveEntryDs1 allocated to the call. |
| I32 cctActiveEntryDs1 | 1.3.6.1.4.1.9.9.163.1.2.3.1.20 | Integer32 | read-only | The DS1 link containing the call. This may be a DS1 contained within a larger grouping of multiple DS1s within a single physical port. If the physical port is of type DS1, this value is identical to cctActiveEntryPort. If the DS1 is a logical subinterface within the physical port, this value is the number of the DS1 within this slot. Examples: 8 port DS1 card - cctActiveEntryPort and cctActiveEntryDs1 will have identical values. 3 port T3 card - cctActiveEntryPort represents T3 ports. cctActiveEntryEntryDs1 represents logical T1 interfaces. Each T3 contains 28 T1 interfaces. The T1 interfaces are numbered sequentially across the entire T3 card. |
| I32 cctActiveEntryPort | 1.3.6.1.4.1.9.9.163.1.2.3.1.19 | Integer32 | read-only | The physical port within the device slot on which the call exists. |
| I32 cctActiveEntrySlot | 1.3.6.1.4.1.9.9.163.1.2.3.1.18 | Integer32 | read-only | The device slot containing the port on which the call exists. |
| cctActiveGroup | 1.3.6.1.4.1.9.9.163.3.2.2 | A collection of objects providing the active call information. | ||
| cctActiveGroupRev1 | 1.3.6.1.4.1.9.9.163.3.2.6 | A collection of objects providing the active call information. | ||
| U32 cctActiveInitialRxRate | 1.3.6.1.4.1.9.9.163.1.2.3.1.14 | Unsigned32 | read-only | Initial receive data rate for this call. If call is a synchronous digital call such as ISDN sync, this value is the data rate of the B-channel. If call is asynchronous, even if using a synchronous transmission medium such as ISDN, the value is determined by the resource providing the asynchronous processing. For modem calls, this value corresponds to the value of cmRXRate from CISCO-MODEM-MGMT-MIB, immediately after the modem has completed initial negotiations. This value does not change, even if the data rate varies during the call. This value will be zero until an initial data rate has been determined. |
| U32 cctActiveInitialTxRate | 1.3.6.1.4.1.9.9.163.1.2.3.1.15 | Unsigned32 | read-only | Initial transmit data rate for this call. If call is a synchronous digital call such as ISDN sync, this value is the data rate of the B-channel. If call is asynchronous, even if using a synchronous transmission medium such as ISDN, the value is determined by the resource providing the asynchronous processing. For modem calls, this value corresponds to the value of cmTXRate from CISCO-MODEM-MGMT-MIB, immediately after the modem has completed initial negotiations. This value does not change, even if the data rate varies during the call. This value will be zero until an initial data rate has been determined. |
| U32 cctActiveMpBundleId | 1.3.6.1.4.1.9.9.163.1.2.3.1.24 | Unsigned32 | read-only | Multilink PPP bundle identification for call if cctActiveServiceType has the value 'mp'. If the value of cctActiveServiceType for this call is not 'mp', then the value of this object is not meaningful. |
| INT cctActiveOrigin | 1.3.6.1.4.1.9.9.163.1.2.3.1.3 | INTEGER | read-only | This object indicates how the call was created. originate(1) - The call was initiated locally with the system sending the setup request. Dialout answer(2) - The call was initiated remotely and the system received the setup request. Dialin |
| TIM cctActivePhysicalLayerReadyTime | 1.3.6.1.4.1.9.9.163.1.2.3.1.5 | TimeStamp | read-only | Value of sysUpTime when the physical layer for the call achieved a steady state and the call is ready for higher protocol layers to begin. In the case of modem calls, the physical layer for the call achieves a steady state when the data rates, modulations, and error correcting protocols have been negotiated between the originating and answering modems. This is primarily intended for calls which connect to a processing resource identified by cctActiveResourceSlot and cctActiveResourcePort. It also applies to digital calls using adaptive rate technologies such as V.110 and V.120. |
| NUM cctActiveReceiveBytes | 1.3.6.1.4.1.9.9.163.1.2.3.1.26 | AbsoluteCounter32 | read-only | The number of bytes received on the call. All the 'raw' bytes are counted including any protocol headers which may or may not be present depending on the value of cctActiveServiceType. |
| I32 cctActiveResourcePort | 1.3.6.1.4.1.9.9.163.1.2.3.1.17 | Integer32 | read-only | Identification of the processing resource allocated to the call. In the case of a call requiring a modem resource, this is the value of cmPortIndex from CISCO-MODEM-MGMT-MIB. This value along with cctActiveResourceSlot uniquely identifies a resource port. Value is -1 if call does not utilize such a resource. |
| I32 cctActiveResourceSlot | 1.3.6.1.4.1.9.9.163.1.2.3.1.16 | Integer32 | read-only | Identification of the processing resource allocated to the call. In the case of a call requiring a modem resource, this is the value of cmSlotIndex from CISCO-MODEM-MGMT-MIB. This value along with cctActiveResourcePort uniquely identifies a resource port. Value is -1 if call does not utilize such a resource. |
| CCT cctActiveServiceType | 1.3.6.1.4.1.9.9.163.1.2.3.1.7 | CctServiceType | read-only | Service associated with the call. This is the highest level of service known to the system for the call. The service represents the encapsulation protocol layer active for the call. In the case of multiple services on a given call, the last service activated will be reported. |
| TIM cctActiveServiceUpTime | 1.3.6.1.4.1.9.9.163.1.2.3.1.6 | TimeStamp | read-only | Value of sysUpTime when the call service type identified in cctActiveServiceType was established. |
| TIM cctActiveSetupTime | 1.3.6.1.4.1.9.9.163.1.2.3.1.2 | TimeStamp | read-only | Value of sysUpTime when the call is first made known to the system. |
| cctActiveTable | 1.3.6.1.4.1.9.9.163.1.2.3 | not-accessible | This table contains entries for active calls in the system. All such calls either originate or terminate at this system. The table is indexed by call ID assigned to the call. | |
| G32 cctActiveTableHighWaterMark | 1.3.6.1.4.1.9.9.163.1.2.2 | Gauge32 | read-only | Maximum number of entries present in cctActiveTable since last system re-initialization. This corresponds to the maximum value reported by cctActiveTableNumberEntries. |
| G32 cctActiveTableNumberEntriesEx | 1.3.6.1.4.1.9.9.163.1.2.1 | Gauge32 | read-only | The number of entries currently in the cctActiveTable. |
| NUM cctActiveTransmitBytes | 1.3.6.1.4.1.9.9.163.1.2.3.1.27 | AbsoluteCounter32 | read-only | The number of bytes transmitted on the call. All the 'raw' bytes are counted including any protocol headers which may or may not be present depending on the value of cctActiveServiceType. |
| STR cctActiveUserId | 1.3.6.1.4.1.9.9.163.1.2.3.1.9 | DisplayString | read-only | The User login ID or zero length string if unavailable. |
| IP cctActiveUserIpAddr | 1.3.6.1.4.1.9.9.163.1.2.3.1.10 | IpAddress | read-only | The IP address assigned to the cctActiveUserId for this call or 0.0.0.0 if not applicable or unavailable. |
| IP cctActiveUserSubnetMask | 1.3.6.1.4.1.9.9.163.1.2.3.1.11 | IpAddress | read-only | The IP subnet mask assigned to the cctActiveUserId for this call or 0.0.0.0 if not applicable or unavailable. |
| TIM cctActiveUserValidationTime | 1.3.6.1.4.1.9.9.163.1.2.3.1.8 | TimeStamp | read-only | Value of sysUpTime when the user identification associated with this call was validated. See cctActiveUserId for description of user identification. |
| U32 cctCallIdPrefix | 1.3.6.1.4.1.9.9.163.1.1.1 | Unsigned32 | read-only | This object may be used in conjunction with objects of type CctCallId to provide call references which are unique across system re-initializations. This value is generated at system re-initialization. It is a 32-bit random number, with very low likely-hood of repeating within the lifetime of the system. |
| NTF cctCallSetupNotification | 1.3.6.1.4.1.9.9.163.2.0.1 | A Call Tracker Setup notification is generated whenever a new active call entry is created in the cctActiveTable. | ||
| T/F cctCallSetupTermNotifyEnable | 1.3.6.1.4.1.9.9.163.1.4.1 | TruthValue | read-write | This variable controls generation of cctCallSetupNotification and cctCallTerminateNotification. When this variable is 'true(1)', generation of these notifications is enabled. When this variable is 'false(2)', generation is disabled. The default value is 'false(2)'. |
| NTF cctCallTerminateNotification | 1.3.6.1.4.1.9.9.163.2.0.2 | A Call Tracker Terminate notification is generated whenever a new history call entry is created in the cctHistoryTable. | ||
| cctGeneral | 1.3.6.1.4.1.9.9.163.1.1 | |||
| cctGeneralGroup | 1.3.6.1.4.1.9.9.163.3.2.1 | A collection of objects providing the general information. | ||
| cctHistory | 1.3.6.1.4.1.9.9.163.1.3 | |||
| STR cctHistoryAccountingSessionId | 1.3.6.1.4.1.9.9.163.1.3.7.1.13 | DisplayString | read-only | Accounting session identification assigned to this call by AAA. The session ID is sent by AAA to RADIUS as the Acct-Session-Id attribute or TACACS+ as the task_id. If no accounting session ID is assigned, the value is a null string. |
| CCT cctHistoryCallCategory | 1.3.6.1.4.1.9.9.163.1.3.7.1.14 | CctCallCategory | read-only | The call category or type |
| STR cctHistoryCalledPartyId | 1.3.6.1.4.1.9.9.163.1.3.7.1.24 | DisplayString | read-only | The called telephone number for this call. For calls answered by the system, this corresponds to the Dialed Number Identification (DNIS). For calls originated by the system, this is the destination number. If not available the string length is zero. |
| CCT cctHistoryCallId | 1.3.6.1.4.1.9.9.163.1.3.7.1.2 | CctCallId | read-only | The call identifier for the call. This is the same value assigned to the call in cctActiveCallId when it was in the cctActiveTable. It is possible for two cctHistoryEntry entries to have the same cctHistoryCallId if one very long running call terminates after the cctActiveCallId has wrapped around and is reassigned to a new short lived call. |
| STR cctHistoryCallingPartyId | 1.3.6.1.4.1.9.9.163.1.3.7.1.25 | DisplayString | read-only | The calling telephone number for this call. For calls answered by the system, this corresponds to the calling identification (CLID). For calls originated by the system, this is the number associated with the device. For the interworking call, this object contains the translated calling party number if there is a translation rule is associated with dial plan for making this outgoing call. If not available this is a zero-length string. |
| CCT cctHistoryCallSignalingType | 1.3.6.1.4.1.9.9.163.1.3.7.1.32 | CctCallSigType | read-only | Signaling type used to setup the call. |
| G32 cctHistoryChargedUnits | 1.3.6.1.4.1.9.9.163.1.3.7.1.27 | Gauge32 | read-only | The number of charged units for this connection. For incoming calls or if charging information is not supplied by the switch, the value of this object will be zero. |
| TIM cctHistoryConnectionTime | 1.3.6.1.4.1.9.9.163.1.3.7.1.5 | TimeStamp | read-only | Value of sysUpTime when the system connected the call. |
| STR cctHistoryDisconnectReasonText | 1.3.6.1.4.1.9.9.163.1.3.7.1.31 | DisplayString | read-only | Text description of the disconnect reason provided. Value is zero-length string if no text is available. |
| TIM cctHistoryDisconnectTime | 1.3.6.1.4.1.9.9.163.1.3.7.1.30 | TimeStamp | read-only | Value of sysUpTime when call was disconnected. This is when the system initiates, detects, or is notified of call termination. This is the call duration from initial setup request. |
| cctHistoryEntry | 1.3.6.1.4.1.9.9.163.1.3.7.1 | not-accessible | The information regarding a single terminated call. An entry of this table is created when the system initiates, detects, or is notified of a call termination. Resources allocated to the call may still be in use by the call when the entry is created. An entry is deleted when it has existed in this table longer than cctHistoryTableRetainTimer minutes. An entry is also removed if the table is full and a new entry needs to be created to accommodate a terminated call. The oldest entry in the table will be deleted. | |
| I32 cctHistoryEntryChannel | 1.3.6.1.4.1.9.9.163.1.3.7.1.23 | Integer32 | read-only | The channel or timeslot within the cctHistoryEntryDs1 which was allocated to the call. |
| I32 cctHistoryEntryDs1 | 1.3.6.1.4.1.9.9.163.1.3.7.1.22 | Integer32 | read-only | The DS1 link containing the call. This may be a DS1 contained within a larger grouping of multiple DS1s within a single physical port. If the physical port is of type DS1, this value is identical to cctActiveEntryPort. If the DS1 is a logical subinterface within the physical port, this value is the number of the DS1 within this slot. Examples: 8 port DS1 card - cctActiveEntryPort and cctActiveEntryDs1 will have identical values. 3 port T3 card - cctActiveEntryPort represents T3 ports. cctActiveEntryEntryDs1 represents logical T1 interfaces. Each T3 contains 28 T1 interfaces. The T1 interfaces are numbered sequentially across the entire T3 card. |
| I32 cctHistoryEntryPort | 1.3.6.1.4.1.9.9.163.1.3.7.1.20 | Integer32 | read-only | The physical port within the device slot on which the call existed. |
| I32 cctHistoryEntrySlot | 1.3.6.1.4.1.9.9.163.1.3.7.1.19 | Integer32 | read-only | The device slot containing the port on which the call existed. |
| cctHistoryGroup | 1.3.6.1.4.1.9.9.163.3.2.3 | A collection of objects providing the historical call information. | ||
| cctHistoryGroupRev1 | 1.3.6.1.4.1.9.9.163.3.2.7 | A collection of objects providing the historical call information. | ||
| U32 cctHistoryIndex | 1.3.6.1.4.1.9.9.163.1.3.7.1.1 | Unsigned32 | not-accessible | A monotonically increasing integer for the sole purpose of indexing terminated calls. When it reaches the maximum value the agent wraps the value back to 1 and will flush existing entries. |
| U32 cctHistoryInitialRxRate | 1.3.6.1.4.1.9.9.163.1.3.7.1.15 | Unsigned32 | read-only | Initial receive data rate for this call. If call is a synchronous digital call such as ISDN sync, this value is the data rate of the B-channel. If call is asynchronous, even if using a synchronous transmission medium such as ISDN, the value is determined by the resource providing the asynchronous processing. For modem calls, this value corresponds to the value of cmRXRate from CISCO-MODEM-MGMT-MIB, immediately after the modem has completed initial negotiations. This value does not change, even if the data rate varies during the call. This value will be zero if the call terminated prior to an initial data rate determination. |
| U32 cctHistoryInitialTxRate | 1.3.6.1.4.1.9.9.163.1.3.7.1.16 | Unsigned32 | read-only | Initial transmit data rate for this call. If call is a synchronous digital call such as ISDN sync, this value is the data rate of the B-channel. If call is asynchronous, even if using a synchronous transmission medium such as ISDN, the value is determined by the resource providing the asynchronous processing. For modem calls, this value corresponds to the value of cmTXRate from CISCO-MODEM-MGMT-MIB, immediately after the modem has completed initial negotiations. This value does not change, even if the data rate varies during the call. This value will be zero if the call terminated prior to an initial data rate determination. |
| U32 cctHistoryMpBundleId | 1.3.6.1.4.1.9.9.163.1.3.7.1.26 | Unsigned32 | read-only | Multilink PPP bundle identification for call if cctHistoryServiceType has the value 'mp'. If the value of cctHistoryServiceType for this call is not 'mp', then the value of this object is not meaningful. |
| INT cctHistoryOrigin | 1.3.6.1.4.1.9.9.163.1.3.7.1.4 | INTEGER | read-only | This object indicates how the call was created. originate(1) - The call was initiated locally with the system sending the setup request. Dialout answer(2) - The call was initiated remotely and the system received the setup request. Dialin |
| TIM cctHistoryPhysicalLayerReadyTime | 1.3.6.1.4.1.9.9.163.1.3.7.1.6 | TimeStamp | read-only | Value of sysUpTime when the physical layer for the call achieved a steady state and the call is ready for higher protocol layers to begin. In the case of modem calls, the physical layer for the call achieves a steady state when the data rates, modulations, and error correcting protocols have been negotiated between the originating and answering modems. This is primarily intended for calls which connect to a processing resource identified by cctHistoryResourceSlot and cctHistoryResourcePort. It also applies to digital calls using adaptive rate technologies such as V.110 and V.120. |
| G32 cctHistoryReceiveBytes | 1.3.6.1.4.1.9.9.163.1.3.7.1.28 | Gauge32 | read-only | The number of bytes received on the call. All the 'raw' bytes are counted including any protocol headers which may or may not be present depending on the value of cctHistoryServiceType. |
| I32 cctHistoryResourcePort | 1.3.6.1.4.1.9.9.163.1.3.7.1.18 | Integer32 | read-only | Identification of processing resource allocated to call. In the case of a call requiring a modem resource, this is the value of cmPortIndex from CISCO-MODEM-MGMT-MIB. This value along with cctHistoryResourceSlot uniquely identifies a resource port. Value is -1 if call does not utilize such a resource. |
| I32 cctHistoryResourceSlot | 1.3.6.1.4.1.9.9.163.1.3.7.1.17 | Integer32 | read-only | Identification of processing resource allocated to call. In the case of a call requiring a modem resource, this is the value of cmSlotIndex from CISCO-MODEM-MGMT-MIB. This value along with cctHistoryResourcePort uniquely identifies a resource port. Value is -1 if call does not utilize such a resource. |
| CCT cctHistoryServiceType | 1.3.6.1.4.1.9.9.163.1.3.7.1.8 | CctServiceType | read-only | Service associated with the call. This is the highest level of service known to the system for the call. The service represents the encapsulation protocol layer active for the call. In the case of multiple services on a given call, the last service activated will be reported. |
| TIM cctHistoryServiceUpTime | 1.3.6.1.4.1.9.9.163.1.3.7.1.7 | TimeStamp | read-only | Value of sysUpTime when the call service type identified in cctHistoryServiceType was established. |
| TIM cctHistorySetupTime | 1.3.6.1.4.1.9.9.163.1.3.7.1.3 | TimeStamp | read-only | Value of sysUpTime when the call was first made known to the system. |
| cctHistoryTable | 1.3.6.1.4.1.9.9.163.1.3.7 | not-accessible | This table provides information on terminated calls. | |
| U32 cctHistoryTableEntriesLimit | 1.3.6.1.4.1.9.9.163.1.3.1 | Unsigned32 | read-write | The upper limit on the number of entries that the cctHistoryTable may contain. A value of zero will prevent any history from being retained. This value may not exceed the system specific limit provided in cctHistoryTableMaxEntries. |
| G32 cctHistoryTableHighWaterMark | 1.3.6.1.4.1.9.9.163.1.3.5 | Gauge32 | read-only | Maximum number of entries present in cctHistoryTable since last system re-initialization or the value of cctHistoryTableEntriesLimit has been changed. This corresponds to the maximum value reported by cctHistoryTableNumberEntries. Changing the value of cctHistoryTableEntriesLimit resets this value to zero. |
| U32 cctHistoryTableMaxEntries | 1.3.6.1.4.1.9.9.163.1.3.2 | Unsigned32 | read-only | The maximum allowed table length supported by this system. The value of cctHistoryTableEntriesLimit may not exceed this value. |
| U32 cctHistoryTableNewestIndex | 1.3.6.1.4.1.9.9.163.1.3.6 | Unsigned32 | read-only | This object provides the index value of the most recent entry currently in the cctHistoryTable. A value of zero indicates there has never been an entry in the table or all entries have expired. |
| G32 cctHistoryTableNumberEntries | 1.3.6.1.4.1.9.9.163.1.3.4 | Gauge32 | read-only | Count of the number of entries currently in the cctHistoryTable. |
| U32 cctHistoryTableRetainTimer | 1.3.6.1.4.1.9.9.163.1.3.3 | Unsigned32 | read-write | The maximum amount of time that an entry will be maintained within the cctHistoryTable before being deleted. A value of zero will prevent any history from being retained. |
| G32 cctHistoryTransmitBytes | 1.3.6.1.4.1.9.9.163.1.3.7.1.29 | Gauge32 | read-only | The number of bytes transmitted on the call. All the 'raw' bytes are counted including any protocol headers which may or may not be present depending on the value of cctHistoryServiceType. |
| STR cctHistoryUserId | 1.3.6.1.4.1.9.9.163.1.3.7.1.10 | DisplayString | read-only | The User login ID or zero length string if unavailable. If this contains a non-zero length string, and cctHistoryUserValidationTime is zero, then the user failed validation. |
| IP cctHistoryUserIpAddr | 1.3.6.1.4.1.9.9.163.1.3.7.1.11 | IpAddress | read-only | The IP address assigned to the cctHistoryUserId for this call or 0.0.0.0 if not applicable or unavailable. |
| IP cctHistoryUserSubnetMask | 1.3.6.1.4.1.9.9.163.1.3.7.1.12 | IpAddress | read-only | The IP subnet mask assigned to the cctHistoryUserId for this call or 0.0.0.0 if not applicable or unavailable. |
| TIM cctHistoryUserValidationTime | 1.3.6.1.4.1.9.9.163.1.3.7.1.9 | TimeStamp | read-only | Value of sysUpTime when the user identification associated with this call was validated. See cctHistoryUserId for description of user identification. |
| cctMIBCompliance | 1.3.6.1.4.1.9.9.163.3.1.1 | The compliance statement for entities which implement the CISCO CALL TRACKER MIB | ||
| cctMIBComplianceRev1 | 1.3.6.1.4.1.9.9.163.3.1.2 | The compliance statement for entities which implement the CISCO CALL TRACKER MIB | ||
| cctMIBCompliances | 1.3.6.1.4.1.9.9.163.3.1 | |||
| cctMIBConformance | 1.3.6.1.4.1.9.9.163.3 | |||
| cctMIBGroups | 1.3.6.1.4.1.9.9.163.3.2 | |||
| cctMIBNotificationPrefix | 1.3.6.1.4.1.9.9.163.2 | |||
| cctMIBNotifications | 1.3.6.1.4.1.9.9.163.2.0 | |||
| cctMIBObjects | 1.3.6.1.4.1.9.9.163.1 | |||
| cctNotificationConfig | 1.3.6.1.4.1.9.9.163.1.4 | |||
| cctNotificationConfigGroup | 1.3.6.1.4.1.9.9.163.3.2.4 | A collection of objects providing the notification configuration. | ||
| cctNotificationGroup | 1.3.6.1.4.1.9.9.163.3.2.5 | The collection of notifications used for call status changes. | ||
| ciscoCallTrackerMIB | 1.3.6.1.4.1.9.9.163 | This MIB module provides information for tracking the progress and status of a data call from the hardware layer through the application or service layer. A data call is a call setup via a signaling protocol (e.g., ISDN D Channel signaling) on the Public Switching Telephony Network to a Network Access Server in order to transfer data, either as a byte stream (e.g., terminal emulation) or in a packet format (e.g., PPP packets) from a data terminal (e.g., Personal Computer) to a data network (e.g., Internet). |
RFC description
Cisco vendor-private MIB for call tracking and monitoring on Cisco voice/telecommunications equipment.
Start monitoring Cisco Network Access Server (NAS) equipment with a free 30-day trial of IPNetwork Monitor. Import MIBs, browse SNMP OIDs, create custom SNMP monitors, configure alerts, and monitor any SNMP-enabled network device from a single console.