| OID symbolic | OID numeric | Type | Access | Description |
| chateauCDProductMIB | 1.3.6.1.4.1.10910.2.2.3.1.1 | | | This MIB defines Nodes and Data Objects to support
Chateau Systems CD Players.
This MIB has been distributed as part of the handout
materials from the SNMP Technology Seminar presented
by Chateau Systems.
Any person or organization making use of this example MIB is
responsible for ensuring its complete suitability for their
own purposes. This includes the text of the legal disclaimers
below, as well as all other aspects.
Chateau Systems reserves the right to make changes in
specifications and other information contained
in this document without prior notice.
The reader should contact Chateau Systems to determine
whether or not such changes have been made.
In no event shall Chateau Systems be liable for any
incidental, indirect, special, or consequential damages
whatsoever (including but not limited to lost profits)
arising out of or related to this document or the
information contained in it, even if Chateau Systems has
been advised of, known, or should have known, the
possibility of such damages.
Chateau Systems grants vendors, end-users, and other interested
parties a non-exclusive license to use this specification
in connection with the management of Chateau Systems products.
Copyright November 2005 Chateau Systems, Inc. |
| chateauCDProdConfig | 1.3.6.1.4.1.10910.2.2.3.1.1.1 | | | CD Configuration Organizational node |
| cdStaticConfig | 1.3.6.1.4.1.10910.2.2.3.1.1.1.1 | | | CD Static Configuration Node |
| OID cdStCfgManufacturer | 1.3.6.1.4.1.10910.2.2.3.1.1.1.1.1 | OBJECT IDENTIFIER | read-only | The IANA issued Enterprise OID for this Product's Manufacturer. |
| STR cdStCfgModel | 1.3.6.1.4.1.10910.2.2.3.1.1.1.1.2 | DisplayString | read-only | Manufacturer's Model Designation |
| STR cdStCfgFirmwareRev | 1.3.6.1.4.1.10910.2.2.3.1.1.1.1.10 | DisplayString | read-only | The Firmware Revision for currently loaded firmware |
| cdDynamicConfig | 1.3.6.1.4.1.10910.2.2.3.1.1.1.2 | | | CD Dynamic Configuration Node |
| STR cdDynCfgUserAlias | 1.3.6.1.4.1.10910.2.2.3.1.1.1.2.1 | DisplayString | read-write | Any user assigned name for this CD player |
| chateauCDProdControl | 1.3.6.1.4.1.10910.2.2.3.1.1.2 | | | CD Control Organizational node |
| INT cdCtlPower | 1.3.6.1.4.1.10910.2.2.3.1.1.2.1 | INTEGER | read-write | Indicated CD Player Power status.
Can be modified by the user. |
| INT cdCtlTrayDoor | 1.3.6.1.4.1.10910.2.2.3.1.1.2.2 | INTEGER | read-write | CD Player tray door status.
Can be modified by the user.
If cdCtlPower = off,
then the user cannot modify this value. |
| T/F cdCtlPlaying | 1.3.6.1.4.1.10910.2.2.3.1.1.2.3 | TruthValue | read-write | CD Player 'play' status.
Can be modified by the user.
If cdCtlPower = off
OR cdCtlTrayDoor = open,
then the user cannot modify this value. |
| chateauCDProdStatus | 1.3.6.1.4.1.10910.2.2.3.1.1.3 | | | CD Player Status organizational node |
| cdChassisStatus | 1.3.6.1.4.1.10910.2.2.3.1.1.3.1 | | | CD Player Chassis status node |
| U32 cdChStPowerOnHours | 1.3.6.1.4.1.10910.2.2.3.1.1.3.1.1 | Unsigned32 | read-only | The total number of hours that this CD Player
has been powered on in its lifetime. |
| U32 cdChStLaserOnHours | 1.3.6.1.4.1.10910.2.2.3.1.1.3.1.2 | Unsigned32 | read-only | The total number of hours that this CD Player's
Laser has been powered on in its lifetime.
Trending this value may predict Laser failures. |
| C32 cdChStCrcErrorCtrEx | 1.3.6.1.4.1.10910.2.2.3.1.1.3.1.3 | Counter32 | read-only | Counter for CRC errors encountered reading CDs.
This Counter is initialized whenever the CD Player
is powered on. |
| I32 cdChStTemperature | 1.3.6.1.4.1.10910.2.2.3.1.1.3.1.4 | Integer32 | read-only | CD Player internal chassis temperature. |
| INT cdChStPowerSupply | 1.3.6.1.4.1.10910.2.2.3.1.1.3.1.5 | INTEGER | read-only | CD Player Power Supply status. |
| cdChangerStatus | 1.3.6.1.4.1.10910.2.2.3.1.1.3.2 | | | CD Player Changer status node |
| U32 cdChangerNbrCdSlots | 1.3.6.1.4.1.10910.2.2.3.1.1.3.2.1 | Unsigned32 | read-only | The maximum number of CDs that can be loaded into
this CD player.
The size of (number of indexed entries in) the cdChangerSlotTable. |
| cdChangerSlotTable | 1.3.6.1.4.1.10910.2.2.3.1.1.3.2.2 | | not-accessible | CD Changer Slot Table. |
| cdChangerSlotEntry | 1.3.6.1.4.1.10910.2.2.3.1.1.3.2.2.1 | | not-accessible | An entry in cdChangerSlotTable. |
| U32 cdChangerSlotNbr | 1.3.6.1.4.1.10910.2.2.3.1.1.3.2.2.1.1 | Unsigned32 | not-accessible | Slot number and table index. |
| INT cdChangerSlotStatus | 1.3.6.1.4.1.10910.2.2.3.1.1.3.2.2.1.2 | INTEGER | read-only | CD Changer Slot Status. |
| U32 cdChangerSlotCDTrackPlaying | 1.3.6.1.4.1.10910.2.2.3.1.1.3.2.2.1.3 | Unsigned32 | read-only | If a CD is currently playing, this is the Track Number.
This is also the value of cdChangerCDTrackNbr for the CD that is playing.
= 0 if no CD is currently playing. |
| U32 cdChangerCDNbrTracks | 1.3.6.1.4.1.10910.2.2.3.1.1.3.2.2.1.4 | Unsigned32 | read-only | The number of Tracks on this CD.
This is also the size the sub-table cdChangerCDTrackTable
for this CD - ie, the maximum value of cdChangerCDTrackNbr. |
| cdChangerCDTrackTable | 1.3.6.1.4.1.10910.2.2.3.1.1.3.2.3 | | not-accessible | Changer Track Table for a single CD. |
| cdChangerCDTrackEntry | 1.3.6.1.4.1.10910.2.2.3.1.1.3.2.3.1 | | not-accessible | An entry in cdChangerCDTrackTable. |
| U32 cdChangerCDTrackNbr | 1.3.6.1.4.1.10910.2.2.3.1.1.3.2.3.1.1 | Unsigned32 | not-accessible | CD Track Number and Table Index |
| T/F cdChangerCDTrackPlaying | 1.3.6.1.4.1.10910.2.2.3.1.1.3.2.3.1.2 | TruthValue | read-only | = true if this Track is currently playing.
Only one Track can be true at a time. |
| U32 cdChangerCDTrackLengthSecs | 1.3.6.1.4.1.10910.2.2.3.1.1.3.2.3.1.3 | Unsigned32 | read-only | Track time in seconds. |
| STR cdChangerCDTrackLengthStr | 1.3.6.1.4.1.10910.2.2.3.1.1.3.2.3.1.4 | DisplayString | read-only | Track time in minutes and seconds displayed as text. |
| STR cdChangerCDTrackTitle | 1.3.6.1.4.1.10910.2.2.3.1.1.3.2.3.1.5 | DisplayString | read-only | CD Track Title.
NULL string if information is not available. |
| STR cdChangerCDTrackArtist | 1.3.6.1.4.1.10910.2.2.3.1.1.3.2.3.1.6 | DisplayString | read-only | CD Track Artist.
NULL string if information is not available. |
| chateauCDProdEvents | 1.3.6.1.4.1.10910.2.2.3.1.1.10 | | | CD Player Event Data and Trap Definitions
are organized under this node. |
| cdEventList | 1.3.6.1.4.1.10910.2.2.3.1.1.10.0 | | | Notification Objects are organized under this node. |
| NTF cdChassisTempAlarmEv | 1.3.6.1.4.1.10910.2.2.3.1.1.10.0.10 | | | Sent when cdChStTemperature > cdChassisTempAlarmThresh.
Will not be resent until cdChStTemperature drops below
cdChasisTempAlarmThresh less 10%.
This trap can be disabled by setting cdChassisTempEvTrapEn = trapDisable. |
| NTF cdChassisTempOkayEv | 1.3.6.1.4.1.10910.2.2.3.1.1.10.0.11 | | | Sent when cdChStTemperature drops below cdChassisTempAlarmThresh.
This trap can be disabled by setting cdChassisTempEvTrapEn = trapDisable. |
| NTF cdPowerSupplyEv | 1.3.6.1.4.1.10910.2.2.3.1.1.10.0.20 | | | Sent when cdChStPowerSupply changes from okay to voltageError,
or from voltageError to okay.
This trap can be disabled by setting cdPowerSupplyEvTrapEn = trapDisable. |
| cdEventControl | 1.3.6.1.4.1.10910.2.2.3.1.1.10.1 | | | Node for data affecting Agent Trap Management Semantics |
| U32 cdEvCtlAgtPollFreq | 1.3.6.1.4.1.10910.2.2.3.1.1.10.1.1 | Unsigned32 | read-write | How often the Agent polls the CD Player for trappable conditions.
Set = 0 to disable all traps.
Persistent through system resets. |
| I32 cdChassisTempAlarmThresh | 1.3.6.1.4.1.10910.2.2.3.1.1.10.1.2 | Integer32 | read-write | User settable to define the Chassis Temperature
past which a Chassis Temperature Alarm will occur.
Agent semantics will apply hysterisis logic so
that traps to not repeat unecessarily when the
chassis temperature is very close to this threshold.
Persistent through system resets. |
| CHA cdChassisTempEvTrapEn | 1.3.6.1.4.1.10910.2.2.3.1.1.10.1.10 | ChateauTrapControl | read-write | User settable to disable/enable Chassis Temperature alarms
and okay events.
Persistent through system resets. |
| CHA cdPowerSupplyEvTrapEn | 1.3.6.1.4.1.10910.2.2.3.1.1.10.1.20 | ChateauTrapControl | read-write | User settable to disable/enable Power Supply alarms
and okay events.
Persistent through system resets. |
| cdEventDescriptors | 1.3.6.1.4.1.10910.2.2.3.1.1.10.2 | | | Event Descriptor Node |
| CHA cdEvSeverity | 1.3.6.1.4.1.10910.2.2.3.1.1.10.2.1 | ChateauEventSeverity | accessible-for-notify | This value is sent with each trap as an
indication of the intended severity of the event. |
| STR cdEvDescription | 1.3.6.1.4.1.10910.2.2.3.1.1.10.2.2 | DisplayString | accessible-for-notify | Text which may provide the user with further diagnostic information. |
| chateauCDProdConformance | 1.3.6.1.4.1.10910.2.2.3.1.1.20 | | | Organizational node for Conformance Objects. |
| cdConformanceGroups | 1.3.6.1.4.1.10910.2.2.3.1.1.20.1 | | | Organizational node for Conformance Groups. |
| cdProdConfigGroup | 1.3.6.1.4.1.10910.2.2.3.1.1.20.1.1 | | | cdProdConfigGroup |
| cdProdControlGroup | 1.3.6.1.4.1.10910.2.2.3.1.1.20.1.2 | | | cdProdControlGroup |
| cdProdStatusGroup | 1.3.6.1.4.1.10910.2.2.3.1.1.20.1.3 | | | cdProdStatusGroup |
| cdProdEventGroup | 1.3.6.1.4.1.10910.2.2.3.1.1.20.1.4 | | | cdProdEventGroup |
| cdProdNotificationsGroup | 1.3.6.1.4.1.10910.2.2.3.1.1.20.1.5 | | | cdProdNotificationsGroup |
| cdCompliance | 1.3.6.1.4.1.10910.2.2.3.1.1.20.2 | | | Specification of mandatory & non-mandatory
MIB objects. |