| OID symbolic | OID numeric | Type | Access | Description |
| cadSpMgtMib | 1.3.6.1.4.1.4998.1.1.15.4 | | | The MIB module describes the C4 Upstream Spectrum Management |
| cadSpMgtNotifications | 1.3.6.1.4.1.4998.1.1.15.4.1 | | | |
| cadSpMgtObjects | 1.3.6.1.4.1.4998.1.1.15.4.2 | | | |
| cadSpMgtGroup | 1.3.6.1.4.1.4998.1.1.15.4.2.1 | | | |
| cadSpMgtGroupTable | 1.3.6.1.4.1.4998.1.1.15.4.2.1.1 | | not-accessible | Each entry in this table defines a C4 Upstream Spectrum
Management group. |
| cadSpMgtGroupEntry | 1.3.6.1.4.1.4998.1.1.15.4.2.1.1.1 | | not-accessible | A set of C4 Upstream Spectrum Management group information.
Entries in the cadSpMgtGroupTable are created and
deleted using the cadSpMgtGroupRowStatus object. |
| I32 cadSpMgtGroupIndex | 1.3.6.1.4.1.4998.1.1.15.4.2.1.1.1.1 | Integer32 | not-accessible | The index used to identify the Upstream Spectrum Group. |
| I32 cadSpMgtGroupSamplePeriod | 1.3.6.1.4.1.4998.1.1.15.4.2.1.1.1.2 | Integer32 | read-create | The time (in seconds) between samples used for the degradation
and the improvement triggers. |
| I32 cadSpMgtGroupHopPeriod | 1.3.6.1.4.1.4998.1.1.15.4.2.1.1.1.3 | Integer32 | read-create | The minimum period of time (in seconds) that must pass between
successive state transitions. |
| I32 cadSpMgtGroupCodeword | 1.3.6.1.4.1.4998.1.1.15.4.2.1.1.1.4 | Integer32 | read-create | The minimum number of codewords that must have been transmitted
on the upstream channel before the degradation and improvement
triggers are considered to be valid. |
| I32 cadSpMgtGroupRetryPeriod | 1.3.6.1.4.1.4998.1.1.15.4.2.1.1.1.5 | Integer32 | read-create | This object specifies the minimum wait time (in seconds)
before the retry is attempted. The retry-period timer controls
how quickly the state machine is allowed to retry when
transition failure occurred. |
| T/F cadSpMgtGroupEnabled | 1.3.6.1.4.1.4998.1.1.15.4.2.1.1.1.6 | TruthValue | read-create | This object allows for the optional enabling and disabling of a
spectrum group. |
| ROW cadSpMgtGroupRowStatus | 1.3.6.1.4.1.4998.1.1.15.4.2.1.1.1.7 | RowStatus | read-create | The status of this conceptual row. To create a row in this
table, set this object to createAndGo(4). Support of the values
includes createAndGo(4) and destroy(6) |
| cadSpMgtStateTable | 1.3.6.1.4.1.4998.1.1.15.4.2.1.2 | | not-accessible | Each entry in this table defines a state used for C4 Upstream
Spectrum Management. |
| cadSpMgtStateEntry | 1.3.6.1.4.1.4998.1.1.15.4.2.1.2.1 | | not-accessible | A set of Upstream Spectrum Management state information.
Entries in the cadSpMgtStateTable are created and
deleted using the cadSpMgtStateRowStatus object. |
| I32 cadSpMgtStateIndex | 1.3.6.1.4.1.4998.1.1.15.4.2.1.2.1.1 | Integer32 | not-accessible | The index used to identify the state in C4 Upstream Spectrum
Management. |
| I32 cadSpMgtStateFrequency | 1.3.6.1.4.1.4998.1.1.15.4.2.1.2.1.2 | Integer32 | read-create | The center of the frequency band for the upstream channel
associated with this state. |
| I32 cadSpMgtStateWidth | 1.3.6.1.4.1.4998.1.1.15.4.2.1.2.1.3 | Integer32 | read-create | The bandwidth for the upstream channel associated with this
state. |
| U32 cadSpMgtStateModulationProfile | 1.3.6.1.4.1.4998.1.1.15.4.2.1.2.1.4 | Unsigned32 | read-create | An entry identical to the docsIfModIndex in the
docsIfCmtsModulationTable that describes the upstream channel
associated with this state. |
| ROW cadSpMgtStateRowStatus | 1.3.6.1.4.1.4998.1.1.15.4.2.1.2.1.5 | RowStatus | read-create | The status of this conceptual row. To create a row in this
table, set this object to createAndGo(4). Support of the
values includes createAndGo(4) and destroy(6) |
| cadSpMgtTriggerTable | 1.3.6.1.4.1.4998.1.1.15.4.2.1.3 | | not-accessible | Each entry in this table defines a trigger for C4 Upstream
Spectrum Management |
| cadSpMgtTriggerEntry | 1.3.6.1.4.1.4998.1.1.15.4.2.1.3.1 | | not-accessible | A set of Upstream Spectrum Management trigger information.
Entries in the cadSpMgtTriggerTable are created and
deleted using the cadSpMgtTriggerRowStatus object. |
| I32 cadSpMgtTriggerIndex | 1.3.6.1.4.1.4998.1.1.15.4.2.1.3.1.1 | Integer32 | not-accessible | The trigger index used to identify the trigger for each state
transition. |
| SPT cadSpMgtTriggerType | 1.3.6.1.4.1.4998.1.1.15.4.2.1.3.1.2 | SpTriggerType | read-create | The trigger type. |
| SPT cadSpMgtTriggerDay | 1.3.6.1.4.1.4998.1.1.15.4.2.1.3.1.3 | SpTriggerDay | read-create | The trigger day is to specify the reoccurrence of the TOD
trigger for a week. The trigger day has the following defined
values:
0: Sunday
1: Monday
2: Tuesday
3: Wednesday
4: Thursday
5: Friday
6: Saturday
7: Everyday |
| SPT cadSpMgtTriggerTOD | 1.3.6.1.4.1.4998.1.1.15.4.2.1.3.1.4 | SpTimeOfDay | read-create | Time of day to transition to next state, in HH:MM:SS format |
| I32 cadSpMgtTriggerPeriod | 1.3.6.1.4.1.4998.1.1.15.4.2.1.3.1.5 | Integer32 | read-create | The amount of time that should be loaded into a timer, in
seconds, once the state machine has transitioned into the
associated current state. When the timer expires, the transition
to next state defined in the state machine is executed. This
value is an integer between 1 and 604,800 (which covers a period
of a week). This object is applicable for trigger type of
periodic(2) |
| U32 cadSpMgtTriggerThres1 | 1.3.6.1.4.1.4998.1.1.15.4.2.1.3.1.6 | Unsigned32 | read-create | This object is applicable for trigger type of degradation (3)
and improvement (4).
For degradation trigger, this is the maximum acceptable
percentage of FEC errors (uncorrectable plus correctable).
For improvement trigger, this is the minimum acceptable
percentage of FEC errors (uncorrectable plus correctable) |
| U32 cadSpMgtTriggerThres2 | 1.3.6.1.4.1.4998.1.1.15.4.2.1.3.1.7 | Unsigned32 | read-create | This object is applicable for trigger type of degradation (3)
and improvement (4).
For degradation trigger, this is the maximum acceptable
percentage of uncorrectable FEC errors.
For improvement trigger, this is the minimum acceptable
percentage of uncorrectable FEC errors. |
| TEN cadSpMgtTriggerThres3 | 1.3.6.1.4.1.4998.1.1.15.4.2.1.3.1.8 | TenthdB | read-create | This object is applicable for trigger type of degradation (3)
and improvement (4).
For degradation trigger, this is the minimum acceptable
Signal/Noise ratio (in dB).
For improvement trigger, this is the maximum acceptable
Signal/Noise ratio (in dB). |
| ROW cadSpMgtTriggerRowStatus | 1.3.6.1.4.1.4998.1.1.15.4.2.1.3.1.9 | RowStatus | read-create | The status of this conceptual row. To create a row in this
table, set this object to createAndGo(4). Support of the values
includes createAndGo(4) and destroy(6) |
| cadSpMgtStateTransTable | 1.3.6.1.4.1.4998.1.1.15.4.2.1.4 | | not-accessible | Each entry in this table defines the state machine in C4 Upstream Spectrum Management. |
| cadSpMgtStateTransEntry | 1.3.6.1.4.1.4998.1.1.15.4.2.1.4.1 | | not-accessible | |
| I32 cadSpMgtTransNextState | 1.3.6.1.4.1.4998.1.1.15.4.2.1.4.1.1 | Integer32 | read-create | The index used to identify the next state to which the state
machine may transition to as a result of this trigger. |
| ROW cadSpMgtStateTransRowStatus | 1.3.6.1.4.1.4998.1.1.15.4.2.1.4.1.2 | RowStatus | read-create | The status of this conceptual row. To create a row in this
table, set this object to createAndGo(4). Support of the values
includes createAndGo(4) and destroy(6) |
| cadSpMgtHistoryTable | 1.3.6.1.4.1.4998.1.1.15.4.2.1.5 | | not-accessible | Table of state transition history. |
| cadSpMgtHistoryEntry | 1.3.6.1.4.1.4998.1.1.15.4.2.1.5.1 | | not-accessible | Entry of state transition history. |
| NUM cadSpMgtHistoryUpChannelIfIndex | 1.3.6.1.4.1.4998.1.1.15.4.2.1.5.1.1 | InterfaceIndex | not-accessible | IfIndex of the upstream channel. |
| DAT cadSpMgtHistoryTime | 1.3.6.1.4.1.4998.1.1.15.4.2.1.5.1.2 | DateAndTime | not-accessible | The value of this object is the actual clock time
when this entry was created. |
| I32 cadSpMgtHistoryTriggerIndex | 1.3.6.1.4.1.4998.1.1.15.4.2.1.5.1.3 | Integer32 | read-only | The trigger index used to identify the trigger for state
transition. A value of 0 indicates a manual trigger. |
| I32 cadSpMgtHistoryFromStateIndex | 1.3.6.1.4.1.4998.1.1.15.4.2.1.5.1.4 | Integer32 | read-only | The index used to identify the current state. |
| I32 cadSpMgtHistoryNextStateIndex | 1.3.6.1.4.1.4998.1.1.15.4.2.1.5.1.5 | Integer32 | read-only | The index used to identify the next state to which the state
machine may transition to. |
| I32 cadSpMgtHistoryResultStateIndex | 1.3.6.1.4.1.4998.1.1.15.4.2.1.5.1.6 | Integer32 | read-only | The index used to identify the result state to which the state
machine has transitioned to. For a successful state transition
request, the value of this object is the same as
cadSpMgtHistoryNextState. |
| TEN cadSpMgtHistorySNR | 1.3.6.1.4.1.4998.1.1.15.4.2.1.5.1.7 | TenthdB | read-only | This object is the measured Signal/Noise ratio (in dB) for the
upstream channel. This object is applicable when the value in
cadSpMgtHistoryTriggerIndex defines the trigger of type
degradation or improvement. |
| U32 cadSpMgtHistoryUFecError | 1.3.6.1.4.1.4998.1.1.15.4.2.1.5.1.8 | Unsigned32 | read-only | This object is the measured percentage of uncorrectable
FEC errors for the upstream channel. This object is applicable
when the value in cadSpMgtHistoryTriggerIndex defines the trigger
of type degradation or improvement. |
| U32 cadSpMgtHistoryFecError | 1.3.6.1.4.1.4998.1.1.15.4.2.1.5.1.9 | Unsigned32 | read-only | This object is the measured percentage of FEC errors
(uncorrectable plus correctable) for the upstream channel.
This object is applicable when the value in
cadSpMgtHistoryTriggerIndex defines the trigger of type
degradation or improvement. |
| I32 cadSpMgtHistorySpareCardId | 1.3.6.1.4.1.4998.1.1.15.4.2.1.5.1.10 | Integer32 | read-only | The cardId of the spare CAM. The value of 0 indicates the
CAM is not spared at the time the request is received. |
| STR cadSpMgtHistoryText | 1.3.6.1.4.1.4998.1.1.15.4.2.1.5.1.11 | DisplayString | read-only | This object provides a human-readable description of the entry,
including all relevant context. |
| I32 cadSpMgtHistoryGroupId | 1.3.6.1.4.1.4998.1.1.15.4.2.1.5.1.12 | Integer32 | read-only | The Upstream Spectrum Group index associated with the upstream channel. |
| UNS cadSpMgtHistoryStateChangeCount | 1.3.6.1.4.1.4998.1.1.15.4.2.1.5.1.13 | Unsigned16 | read-only | Provides the count of state changes in the history entry. This object will
always increase. It is 16 bits, once it is at 0xffff, the counter will roll
over and start from beginning. |
| U32 cadSpMgtHistorySysUpTime | 1.3.6.1.4.1.4998.1.1.15.4.2.1.5.1.14 | Unsigned32 | read-only | Provides the system up time in the history entry. This object will
always increase. |
| cadSpMgtUpChannelTable | 1.3.6.1.4.1.4998.1.1.15.4.2.1.6 | | not-accessible | This table describes Upstream Frequency Agility attributes of
attached upstream channels. |
| cadSpMgtUpChannelEntry | 1.3.6.1.4.1.4998.1.1.15.4.2.1.6.1 | | not-accessible | The List of Upstream Frequency Agility attributes associated with
an upstream channel. |
| I32 cadSpMgtUpChannelCurrState | 1.3.6.1.4.1.4998.1.1.15.4.2.1.6.1.1 | Integer32 | read-only | The current state as a result of the upstream spectrum group
state transition. This object is only applicable if upstream
spectrum management is enabled for this upstream channel. |
| DAT cadSpMgtUpChannelStateTransTime | 1.3.6.1.4.1.4998.1.1.15.4.2.1.6.1.2 | DateAndTime | read-only | The value of this object is the actual clock time when the current
state information in cadIfUpChannelSpGroupCurrState is most
recently updated. |
| cadSpMgtRequests | 1.3.6.1.4.1.4998.1.1.15.4.2.2 | | | |
| NUM cadSpMgtRequestUpChannelIfIndex | 1.3.6.1.4.1.4998.1.1.15.4.2.2.1 | InterfaceIndex | read-write | IfIndex of the upstream channel. |
| I32 cadSpMgtRequestTriggerIndex | 1.3.6.1.4.1.4998.1.1.15.4.2.2.2 | Integer32 | read-write | The trigger index used to identify the trigger. A value of 0
indicates no trigger is attempted. |
| I32 cadSpMgtRequestNextState | 1.3.6.1.4.1.4998.1.1.15.4.2.2.3 | Integer32 | read-write | The index used to identify the next state to which the state
machine may transition to. |
| TEN cadSpMgtRequestSNR | 1.3.6.1.4.1.4998.1.1.15.4.2.2.4 | TenthdB | read-write | This object is the measured Signal/Noise ratio (in dB) for the
upstream channel. This object is applicable when the value in
cadSpMgtRequestTriggerIndex defines the trigger of type
degradation or improvement. |
| U32 cadSpMgtRequestUFecError | 1.3.6.1.4.1.4998.1.1.15.4.2.2.5 | Unsigned32 | read-write | This object is the measured percentage of uncorrectable
FEC errors for the upstream channel.
This object is applicable when the value in
cadSpMgtRequestTriggerIndex defines the trigger of type
degradation or improvement. |
| U32 cadSpMgtRequestFecError | 1.3.6.1.4.1.4998.1.1.15.4.2.2.6 | Unsigned32 | read-write | This object is the measured percentage of FEC errors
(uncorrectable plus correctable) for the upstream channel.
This object is applicable when the value in
cadSpMgtRequestTriggerIndex defines the trigger of type
degradation or improvement. |
| T/F cadSpMgtRequestCommit | 1.3.6.1.4.1.4998.1.1.15.4.2.2.7 | TruthValue | read-write | The command to execute the request when set to
true(1).
The following are reasons for rejecting an SNMP
SET to this object:
- An operation is commited for a non-existing upstream channel ID or the corresponding ifOperStatus is down(2).
- An operation is committed but cadSpMgtRequestNextState is not an existing state index in cadSpMgtStateEntry.
- An operation is committed but the value in cadSpMgtRequestTriggerIndex is non-zero and not an existing trigger index in cadSpMgtTriggerEntry.
Reading this object always returns false(2). |
| cadSpMgtConformance | 1.3.6.1.4.1.4998.1.1.15.4.3 | | | |