| OID symbolic | OID numeric | Type | Access | Description |
| atAlmMon | 1.3.6.1.4.1.207.8.4.4.3.26 | | | The AT Alarm Monitoring MIB for managing and
reporting device alarms. |
| atAlmMonActionTable | 1.3.6.1.4.1.207.8.4.4.3.26.1 | | not-accessible | A table of information describing alarm monitoring inputs
and consequent actions (i.e. fault LED & relay outputs). |
| atAlmMonActionEntry | 1.3.6.1.4.1.207.8.4.4.3.26.1.1 | | not-accessible | The description and configuration of what to do for a specific monitored alarm. |
| U32 atAlmMonActionStackMemberId | 1.3.6.1.4.1.207.8.4.4.3.26.1.1.1 | Unsigned32 | read-only | The index of the stack member of this alarm action. |
| U32 atAlmMonActionIndex | 1.3.6.1.4.1.207.8.4.4.3.26.1.1.2 | Unsigned32 | read-only | The numeric identifier of this alarm action. |
| ATA atAlmMonAlarmType | 1.3.6.1.4.1.207.8.4.4.3.26.1.1.3 | AtAlmMonAlarmType | read-only | The type of alarm that this action monitors. |
| U32 atAlmMonAlarmTypeSelection | 1.3.6.1.4.1.207.8.4.4.3.26.1.1.4 | Unsigned32 | read-only | The 1-based index of the alarm of the particular type (as catagorised by atAlmMonAlarmType). |
| STR atAlmMonActionDescription | 1.3.6.1.4.1.207.8.4.4.3.26.1.1.5 | DisplayStringUnsized | read-only | The description of this alarm monitoring entry. |
| ATA atAlmMonActionUseRelay1 | 1.3.6.1.4.1.207.8.4.4.3.26.1.1.6 | AtAlmMonActionUseOutput | read-write | Indicates/controls whether or not this alarm monitor drives the first relay output. |
| ATA atAlmMonActionUseRelay2 | 1.3.6.1.4.1.207.8.4.4.3.26.1.1.7 | AtAlmMonActionUseOutput | read-write | Indicates/controls whether or not this alarm monitor drives the second relay output. |
| ATA atAlmMonActionUseRelay3 | 1.3.6.1.4.1.207.8.4.4.3.26.1.1.8 | AtAlmMonActionUseOutput | read-write | Indicates/controls whether or not this alarm monitor drives the third relay output. |
| ATA atAlmMonActionUseFaultLed | 1.3.6.1.4.1.207.8.4.4.3.26.1.1.9 | AtAlmMonActionUseOutput | read-write | Indicates/controls whether or not this alarm monitor drives the fault LED. |
| ATA atAlmMonAbnormalState | 1.3.6.1.4.1.207.8.4.4.3.26.1.1.10 | AtAlmMonAbnormalState | read-write | Indicates/sets the abnormal (i.e. alarm active) state for a contact input.
Only used for contactInput alarm monitors, ignored for all other types. |
| ATA atAlmMonActionState | 1.3.6.1.4.1.207.8.4.4.3.26.1.1.11 | AtAlmMonActionState | read-only | Indicates the current state of this alarm monitor. |
| T/F atAlmMonPerStackConfiguration | 1.3.6.1.4.1.207.8.4.4.3.26.2 | TruthValue | read-write | Indicates whether to support per stack member configuration.
A true value means that atAlmMonAvailableTable, atAlmMonOutputRelayTable,
atAlmMonOutputLedTable and atAlmMonIutputContactTable are supported.
A notTrue value means that atAlmMonActionTable is supported.
This object should be set to a value that reflects the way that alarm
monitors are actually configured or to be configured. |
| atAlmMonAvailableTable | 1.3.6.1.4.1.207.8.4.4.3.26.3 | | not-accessible | A table of information listing available alarms on the device. |
| atAlmMonAvailableEntry | 1.3.6.1.4.1.207.8.4.4.3.26.3.1 | | not-accessible | The description and configuration of each available alarm. |
| U32 atAlmMonAvailableAlarmId | 1.3.6.1.4.1.207.8.4.4.3.26.3.1.1 | Unsigned32 | read-only | The unique numeric identifier for this alarm. |
| ATA atAlmMonAvailableType | 1.3.6.1.4.1.207.8.4.4.3.26.3.1.2 | AtAlmMonAlarmType | read-only | The type of this alarm, such as externalPSU(1), epsr(2), etc. |
| U32 atAlmMonAvailableTypeIndex | 1.3.6.1.4.1.207.8.4.4.3.26.3.1.3 | Unsigned32 | read-only | The index of the particular alarm type (catagorised by atAlmMonAlarmType).
For some alarms there are multiple sources on the device (i.e. power supplies).
In these cases this object indicates which source the alarm is for (i.e.
power supply 1, or power supply 2).
This object is used for externalPSU(1) and contactInput(3) alarm only. |
| U32 atAlmMonAvailableStkId | 1.3.6.1.4.1.207.8.4.4.3.26.3.1.4 | Unsigned32 | read-only | The id of stack member this alarm triggers on.
This object is used for externalPSU(1), contactInput(3), portLinkDown(4),
portPoeFailure(7) and temperature(8) alarm only. |
| STR atAlmMonAvailableIfName | 1.3.6.1.4.1.207.8.4.4.3.26.3.1.5 | DisplayStringUnsized | read-only | The name of the specific interface that this alarm triggers on, such as 'port1.0.1.
This object is used for portLinkDown(4) and portPoeFailure(7) alarm only. |
| ATA atAlmMonAvailableState | 1.3.6.1.4.1.207.8.4.4.3.26.3.1.6 | AtAlmMonActionState | read-only | Indicates the current state of this alarm. |
| atAlmMonOutputRelayTable | 1.3.6.1.4.1.207.8.4.4.3.26.4 | | not-accessible | This table lists all associations existing on the device between output
relays and alarms.
Theoretically, an output relay on the device can be triggered by multiple
alarms and an alarm can trigger multiple output relays. |
| atAlmMonOutputRelayEntry | 1.3.6.1.4.1.207.8.4.4.3.26.4.1 | | not-accessible | This entry reprents an association between one ouput relay and one alarm.
To configure an alarm to use an output relay, a user needs to create a new
entry. This can be done through writing a value of used(2) to object
atAlmMonOutputRelayUsage that is specified by atAlmMonOutputRelayStkId,
atAlmMonOutputRelayNumber, and atAlmMonOutputRelayAlarmId.
To reconfigure an alarm not to use an output relay, a user needs to delete
the entry. This can be done by writing a value of unused(1) to object
atAlmMonOutputRelayUsage. |
| U32 atAlmMonOutputRelayStkId | 1.3.6.1.4.1.207.8.4.4.3.26.4.1.1 | Unsigned32 | read-only | The id of stack member that the relay(s) reside on. |
| U32 atAlmMonOutputRelayNumber | 1.3.6.1.4.1.207.8.4.4.3.26.4.1.2 | Unsigned32 | read-only | The number (i.e. the 1 based index) of the relay. |
| U32 atAlmMonOutputRelayAlarmId | 1.3.6.1.4.1.207.8.4.4.3.26.4.1.3 | Unsigned32 | read-only | The id of the alarm that may use this relay output. |
| ATA atAlmMonOutputRelayUsage | 1.3.6.1.4.1.207.8.4.4.3.26.4.1.4 | AtAlmMonActionUseOutput | read-write | This object indicates whether or not the relay output is used.
Since there are entries only for existing associations between the output
relays and the alarms, the object value should be always used(2).
If a user sets a value of unused(1) to this object, then the whole entry
will be deleted.
If a user sets a value of used(2) to this object with new index, then
a new entry should be created if stack member id, relay number and
alarm id are specified properly in the index. |
| atAlmMonOutputLedTable | 1.3.6.1.4.1.207.8.4.4.3.26.5 | | not-accessible | This table lists all associations existing on the device between output
LED(s) and alarms.
Theoretically, an output LED on the device can be triggered by multiple
alarms and an alarm can trigger multiple LED(s). |
| atAlmMonOutputLedEntry | 1.3.6.1.4.1.207.8.4.4.3.26.5.1 | | not-accessible | This entry reprents an association between one LED and one alarm.
To configure an alarm to use an output LED, a user needs to create a new
entry. This can be done through writing a value of used(2) to object
atAlmMonOutputLedUsage that is specified by atAlmMonOutputLedStkId and
atAlmMonOutputRelayAlarmId.
To reconfigure an alarm not to use an output LED, a user needs to delete
the entry. This can be done by writing a value of unused(1) to object
atAlmMonOutputLedUsage. |
| U32 atAlmMonOutputLedStkId | 1.3.6.1.4.1.207.8.4.4.3.26.5.1.1 | Unsigned32 | read-only | The id of stack member that the output LED resides on. |
| U32 atAlmMonOutputLedAlarmId | 1.3.6.1.4.1.207.8.4.4.3.26.5.1.2 | Unsigned32 | read-only | The id of the alarm that may use this output LED. |
| ATA atAlmMonOutputLedUsage | 1.3.6.1.4.1.207.8.4.4.3.26.5.1.3 | AtAlmMonActionUseOutput | read-write | This object indicates whether or not an LED is used.
Since there are entries only for existing associations between the output
LED(s) and the alarms, the object value should be always used(2).
If a user sets a value of unused(1) to this object, then the whole entry
will be deleted.
If a user sets a value of used(2) to this object with new index, then
a new entry should be created if stack member id and alarm id are
specified properly in the index. |
| atAlmMonInputContactTable | 1.3.6.1.4.1.207.8.4.4.3.26.6 | | not-accessible | This table lists all input contacts on the device and their positions. |
| atAlmMonInputContactEntry | 1.3.6.1.4.1.207.8.4.4.3.26.6.1 | | not-accessible | The information of each input contact configuration. |
| U32 atAlmMonInputContactStkId | 1.3.6.1.4.1.207.8.4.4.3.26.6.1.1 | Unsigned32 | read-only | The id of stack member that the input contact reside on. |
| U32 atAlmMonInputContactNumber | 1.3.6.1.4.1.207.8.4.4.3.26.6.1.2 | Unsigned32 | read-only | The number (i.e. the 1 based index) of the input contact. |
| ATA atAlmMonInputContactPosition | 1.3.6.1.4.1.207.8.4.4.3.26.6.1.3 | AtAlmMonContactPosition | read-write | This object represents the position of the input contact. It is either
open or closed.
A user can reconfigure the position of an input contact by setting
a different value to this object. |