| OID symbolic | OID numeric | Type | Access | Description |
| mibsystemProfile | 1.3.6.1.4.1.529.23.125 | | | |
| mibsystemProfile_StatusNumberEntry | 1.3.6.1.4.1.529.23.125.2.1 | | not-accessible | A mibsystemProfile__status_number entry containing objects that maps to the parameters of mibsystemProfile__status_number profile. |
| mibsystemProfile_StatusNumberTable | 1.3.6.1.4.1.529.23.125.2 | | not-accessible | A list of mibsystemProfile__status_number profile entries. |
| mibsystemProfileEntry | 1.3.6.1.4.1.529.23.125.1.1 | | not-accessible | A mibsystemProfile entry containing objects that
maps to the parameters of mibsystemProfile profile. |
| mibsystemProfileTable | 1.3.6.1.4.1.529.23.125.1 | | not-accessible | A list of mibsystemProfile profile entries. |
| INT systemProfile_Action_o | 1.3.6.1.4.1.529.23.125.1.1.52 | INTEGER | read-write | |
| INT systemProfile_AnalogEncoding | 1.3.6.1.4.1.529.23.125.1.1.26 | INTEGER | read-write | Sets the encoding standard for digitized analog data to either u-Law or A-Law. Universally sets all codecs on the unit to the value selected. Defaults to u-Law for T1, A-Law for E1 interfaces. |
| INT systemProfile_AutoLogout | 1.3.6.1.4.1.529.23.125.1.1.16 | INTEGER | read-write | When TRUE select the default security profile on loss of CD/DTR from the main console port. |
| STR systemProfile_BootSrVersion | 1.3.6.1.4.1.529.23.125.1.1.43 | DisplayString | read-only | Place for tntsrb, the shelf controller boot loader, to provide its version. Boot loader updates the field with its version on every system reset |
| INT systemProfile_CallByCall | 1.3.6.1.4.1.529.23.125.1.1.45 | INTEGER | read-write | PRI Called Party element's Network Specific Facility for Call-by-Call. |
| INT systemProfile_CallRoutingSortMethod | 1.3.6.1.4.1.529.23.125.1.1.31 | INTEGER | read-write | How to sort the Call Routing table for analog calls. |
| INT systemProfile_Console | 1.3.6.1.4.1.529.23.125.1.1.6 | INTEGER | read-write | A MenuType specifying the type of interface to use on the console port. |
| INT systemProfile_ConsoleSecurity | 1.3.6.1.4.1.529.23.125.1.1.7 | INTEGER | read-write | Serial console security for the control port. |
| STR systemProfile_Contact | 1.3.6.1.4.1.529.23.125.1.1.3 | DisplayString | read-write | The name of the contact for this device. SNMP readable. |
| INT systemProfile_ControlBusType | 1.3.6.1.4.1.529.23.125.1.1.42 | INTEGER | read-write | How to send control bus messages. This attribute exists only when the shelf-controller-type is not SLAVE. |
| INT systemProfile_Country | 1.3.6.1.4.1.529.23.125.1.1.46 | INTEGER | read-write | Country in which the system is located. |
| INT systemProfile_DelayDualPortDialing | 1.3.6.1.4.1.529.23.125.1.1.24 | INTEGER | read-write | TRUE if we should delay between dual port calls, FALSE if they should be placed at the same time. |
| INT systemProfile_DigitalCallRoutingSortMethod | 1.3.6.1.4.1.529.23.125.1.1.32 | INTEGER | read-write | How to sort the Call Routing table for digital calls. |
| INT systemProfile_DmSubaddress | 1.3.6.1.4.1.529.23.125.1.1.12 | INTEGER | read-write | sub-address assigned to digital modem connections. |
| STR systemProfile_EditNumber | 1.3.6.1.4.1.529.23.125.1.1.25 | DisplayString | read-write | The menu number of the default edit screen. |
| INT systemProfile_ExactMatchCallRouting | 1.3.6.1.4.1.529.23.125.1.1.33 | INTEGER | read-write | If yes, the system will search for an exact match of call-route profile parameters when selecting devices. Wildcard matches will be accepted only after all 4 quadrants have been searched. (APX only) |
| INT systemProfile_IdleLogout | 1.3.6.1.4.1.529.23.125.1.1.17 | INTEGER | read-write | When non-zero select the default security profile after this value of minutes with no keyboard activity. |
| INT systemProfile_IgnoreLineup | 1.3.6.1.4.1.529.23.125.1.1.51 | INTEGER | read-write | If ignore-lineup in line config profile is set to SYSTEM DEFINED, then this will take precedence. |
| INT systemProfile_IncCallDistrib | 1.3.6.1.4.1.529.23.125.1.1.50 | INTEGER | read-write | Route incoming calls to first available valid port or the least used among a set of ports. |
| INT systemProfile_Index_o | 1.3.6.1.4.1.529.23.125.1.1.1 | INTEGER | read-only | |
| STR systemProfile_JamFileComponents_JamFile1 | 1.3.6.1.4.1.529.23.125.1.1.53 | DisplayString | read-only | File name of the first JAM file's component |
| STR systemProfile_JamFileComponents_JamFile2 | 1.3.6.1.4.1.529.23.125.1.1.54 | DisplayString | read-only | File name of the second JAM file's component |
| STR systemProfile_JamFileComponents_JamFile3 | 1.3.6.1.4.1.529.23.125.1.1.55 | DisplayString | read-only | File name of the third JAM file's component |
| STR systemProfile_JamFileComponents_JamFile4 | 1.3.6.1.4.1.529.23.125.1.1.56 | DisplayString | read-only | File name of the fourth JAM file's component |
| STR systemProfile_JamFileComponents_JamFile5 | 1.3.6.1.4.1.529.23.125.1.1.57 | DisplayString | read-only | File name of the fifth JAM file's component |
| STR systemProfile_JamFileComponents_JamFile6 | 1.3.6.1.4.1.529.23.125.1.1.58 | DisplayString | read-only | File name of the sixth JAM file's component |
| INT systemProfile_LanSubaddress | 1.3.6.1.4.1.529.23.125.1.1.11 | INTEGER | read-write | sub-address assigned to sync lan connections. |
| STR systemProfile_Location | 1.3.6.1.4.1.529.23.125.1.1.4 | DisplayString | read-write | The location of this device. SNMP readable. |
| INT systemProfile_MasterShelfController | 1.3.6.1.4.1.529.23.125.1.1.35 | INTEGER | read-write | Master shelf controller number. This attribute exists only when the shelf-controller-type is SLAVE. Note: This variable is not applicable to the APX 8000. |
| INT systemProfile_MaxDialoutTime | 1.3.6.1.4.1.529.23.125.1.1.21 | INTEGER | read-write | The max time in Sec, system will wait for Call Setup Complete |
| INT systemProfile_MaxSystemDS0Mins | 1.3.6.1.4.1.529.23.125.1.1.20 | INTEGER | read-write | Sets the high water billing mark at which all originating switched connections are brought down. |
| INT systemProfile_ModemPriNumberingPlanId | 1.3.6.1.4.1.529.23.125.1.1.38 | INTEGER | read-write | PRI Called Party element's Numbering-Plan-ID value for outgoing modem calls. |
| INT systemProfile_ModemPriTypeOfNumber | 1.3.6.1.4.1.529.23.125.1.1.37 | INTEGER | read-write | PRI Called Party element's Type-Of-Number value for outgoing modem calls. |
| STR systemProfile_Name | 1.3.6.1.4.1.529.23.125.1.1.2 | DisplayString | read-write | The name of the system given by the user, a standard null terminated ASCII string. |
| INT systemProfile_NasPortFormat | 1.3.6.1.4.1.529.23.125.1.1.59 | INTEGER | read-write | Specifies NAS-Port-Format used to calculate the NAS-Port-ID. When set to 'not-applicable', indicates that the NAS Port Format is determined by the settings in the 'new-nas-port-id-format' field. Defaults to 'not-applicable'. |
| INT systemProfile_NewNasPortIdFormat | 1.3.6.1.4.1.529.23.125.1.1.36 | INTEGER | read-write | Field is deprecated; use the 'nas-port-format' field to specify the NAS port format. Will be used only if 'nas-port-format' is set to 'not-applicable'. TRUE if new NAS port ID format is used, FALSE if old NAS Port ID is used. On the TNT product family the new NAS port ID format is used by default. The old format cannot be used for multi-shelf systems or if any line cards are in a slot greater than the twelfth position. |
| INT systemProfile_NumDigitsTrunkGroups | 1.3.6.1.4.1.529.23.125.1.1.15 | INTEGER | read-write | Specify number of digits TrunkGroups support. |
| INT systemProfile_oDS0MinRst | 1.3.6.1.4.1.529.23.125.1.1.19 | INTEGER | read-write | Has three choices: Off, 24Hr or Monthly. When enabled, the following maxSystemDS0Mins is the high water mark at which all switched connections originating on the system will be taken down. |
| INT systemProfile_P50SwitchUsage | 1.3.6.1.4.1.529.23.125.1.1.18 | INTEGER | read-write | What the P50 switch does. |
| INT systemProfile_ParallelDialing | 1.3.6.1.4.1.529.23.125.1.1.22 | INTEGER | read-write | The number of simultaneous DS0 channel outdials the switch allows. |
| INT systemProfile_PermConnUpdMode | 1.3.6.1.4.1.529.23.125.1.1.40 | INTEGER | read-write | Enables nonintrusive remote update of permanent connections' configurations. 'Changed' means that only changed connections will be torn down and reestablished, 'All' means all existing permanent connections will be turn down and then reestablished only if they are fetched from the RADIUS server again |
| INT systemProfile_PotsDigitTimeout | 1.3.6.1.4.1.529.23.125.1.1.47 | INTEGER | read-write | POTS interdigit timeout. |
| INT systemProfile_SerialSubaddress | 1.3.6.1.4.1.529.23.125.1.1.10 | INTEGER | read-write | sub-address assigned to serial port connections. |
| INT systemProfile_SessionidBase | 1.3.6.1.4.1.529.23.125.1.1.27 | INTEGER | read-write | The base session ID value |
| INT systemProfile_ShelfControllerType | 1.3.6.1.4.1.529.23.125.1.1.34 | INTEGER | read-write | Used to define the role of this controller in a single-shelf or multi-shelf system. Note: This variable is not applicable to the APX 8000. |
| INT systemProfile_SingleFileIncoming | 1.3.6.1.4.1.529.23.125.1.1.23 | INTEGER | read-write | Should the calls be treated as a single-file list, or in parallel. PictureTel wants parallel others want single-file. |
| STR systemProfile_StatusNumber | 1.3.6.1.4.1.529.23.125.2.1.3 | DisplayString | read-write | An array of status screen number entries used to specify the default status screen layout. |
| INT systemProfile_StatusNumber_Index_o | 1.3.6.1.4.1.529.23.125.2.1.1 | INTEGER | read-only | |
| INT systemProfile_StatusNumber_Index1_o | 1.3.6.1.4.1.529.23.125.2.1.2 | INTEGER | read-only | |
| INT systemProfile_SubAddressMode | 1.3.6.1.4.1.529.23.125.1.1.9 | INTEGER | read-write | Selects system wide sub-address support. See mibglob.mdf for details. |
| INT systemProfile_SupportDbcs | 1.3.6.1.4.1.529.23.125.1.1.49 | INTEGER | read-write | TRUE if we should support DBCS character set, FALSE if not. |
| STR systemProfile_SysModemProfile_oATAnswerString | 1.3.6.1.4.1.529.23.125.1.1.44 | DisplayString | read-write | Allows the user to enter any additional AT commands in the modem answer string. |
| INT systemProfile_System8kClock | 1.3.6.1.4.1.529.23.125.1.1.48 | INTEGER | read-write | 8KHz clock source for Stinger-10. |
| INT systemProfile_SystemRmtMgmt | 1.3.6.1.4.1.529.23.125.1.1.8 | INTEGER | read-write | Set true if this system allows remote management. |
| INT systemProfile_T302Timer | 1.3.6.1.4.1.529.23.125.1.1.30 | INTEGER | read-write | Number of milliseconds to wait for additional called number information elements for an incoming T-Online call. Defaults to 1500. |
| INT systemProfile_TermRate | 1.3.6.1.4.1.529.23.125.1.1.5 | INTEGER | read-write | The bit rate of the management terminal port, as given above. |
| INT systemProfile_TOnline | 1.3.6.1.4.1.529.23.125.1.1.28 | INTEGER | read-write | TRUE if we should route calls to T-Online, FALSE if not. |
| INT systemProfile_TOnlineMostAvailChan | 1.3.6.1.4.1.529.23.125.1.1.29 | INTEGER | read-write | TRUE if T-Online calls are to be routed to NT line with the most available B-channels FALSE if it is based on circular basis. |
| STR systemProfile_UserstatFormat | 1.3.6.1.4.1.529.23.125.1.1.41 | DisplayString | read-write | Defines the output format of the session listing command 'userstat' and the remote user information protocol 'finger'. The following special characters will be converted to their values for each listed session. The width of each field is indicated in []. %i [10] SessionID, Unique ID assigned to the session. %l [10] Line/Chan, Physical address (shelf.slot.line/chan). %s [11] Slot:Item, shelf:slot:item/logical-item of the host port. %r [11] Tx/Rx Rate, Transmit and receive rates. %d [ 3] Svc, A three-letter code showing the type of service. %a [15] Address, IP address. %u [14] Username, Connection profile name. %c [10] ConnTime, Ammount of time connected in hours:minutes:seconds. %t [10] IdleTime, Ammount of time idle in hours:minutes:seconds. %n [24] Dialed#, Number dialed if known. %f [24] Calling#, Number calling from if known. For example set userstat-format = '%i %l %s %r %d %a %u %c %t %n' would set the format to the factory default value. |
| INT systemProfile_UseTrunkGroups | 1.3.6.1.4.1.529.23.125.1.1.14 | INTEGER | read-write | Enables TrunkGroups for all network lines. |
| INT systemProfile_V110Subaddress | 1.3.6.1.4.1.529.23.125.1.1.13 | INTEGER | read-write | sub-address assigned to V.110 rate adaption connections |
| INT systemProfile_WanInterface | 1.3.6.1.4.1.529.23.125.1.1.39 | INTEGER | read-write | Sets the type of WAN interface supported: T1-CSU or Serial WAN. |