ADN-MIB :: adnHscBoardTrMgtMOBEFCIOnTh

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsADN-MIBadnHscBoardTrMgtMOBEFCIOnTh

adnHscBoardTrMgtMOBEFCIOnTh

Module: ADN-MIB

OID (symbolic): ADN-MIB::adnHscBoardTrMgtMOBEFCIOnTh

OID (numeric): 1.3.6.1.4.1.637.3.1.5.15.25.1.9

Node type: OBJECT-TYPE

Type: INTEGER

Access: read-write

Description: This indicates the Explicit Forward Congestion Indication (EFCI) activation threshold in medium priority output buffer (OB); EFCI is generated towards the receiver termination point, in order to prevent congestion situation to be encountered within the output buffer; EFCI tagging is activated as soon as the activation threshold is reached; EFCI tagging is stopped as soon as the filling of the OB is below the EFCI desactivation threshold; the EFCI desactivation threshold is equal to the activation threshold minus 1/10 of the activation threshold; the value range of the threshold is 0..adnHscBoardTrMgtMOBSize; this is not relevant for HSC boards without a medium priority output buffer (e.g. BBT1B and BBE1B)..

What is adnHscBoardTrMgtMOBEFCIOnTh?

This configurable integer threshold determines when EFCI congestion signaling activates for medium-priority output buffers. Network engineers adjust this parameter to control when the switch notifies upstream devices that congestion is beginning, allowing them to proactively reduce traffic. For example, setting this to 4500 causes congestion warnings to activate when the medium buffer exceeds 4500 cells.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.637.3.1.5.15.25.1.9
snmpwalk -v2c -c public <target> ADN-MIB::adnHscBoardTrMgtMOBEFCIOnTh

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.637.3.1.5.15.25.1.9.1
snmpget -v2c -c public <target> ADN-MIB::adnHscBoardTrMgtMOBEFCIOnTh.1

Set instance 1 (SNMPv2c):

snmpset -v2c -c private <target> 1.3.6.1.4.1.637.3.1.5.15.25.1.9.1 i <value>

Start monitoring Ascom Timeplex ADN multiplexers (legacy) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the ADN-MIB::adnHscBoardTrMgtMOBEFCIOnTh OID value, configure state conditions and alerts, and monitor any Ascom Timeplex ADN multiplexers (legacy) from a single console.

OID Breakdown

Upper-level ancestors (6 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
Numeric OIDNameModule
1.3.6.1.4.1.637alcatelADN-MIB
1.3.6.1.4.1.637.3adnADN-MIB
1.3.6.1.4.1.637.3.1adnMIBADN-MIB
1.3.6.1.4.1.637.3.1.5adnProprietaryADN-MIB
1.3.6.1.4.1.637.3.1.5.15adnNodeSupervisionMIBADN-MIB
1.3.6.1.4.1.637.3.1.5.15.25adnHscBoardTrMgtTableADN-MIB
1.3.6.1.4.1.637.3.1.5.15.25.1adnHscBoardTrMgtEntryADN-MIB
1.3.6.1.4.1.637.3.1.5.15.25.1.9adnHscBoardTrMgtMOBEFCIOnThADN-MIB