ADN-MIB :: adnHscBoardTrMgtLOBEFCIOnTh

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsADN-MIBadnHscBoardTrMgtLOBEFCIOnTh

adnHscBoardTrMgtLOBEFCIOnTh

Module: ADN-MIB

OID (symbolic): ADN-MIB::adnHscBoardTrMgtLOBEFCIOnTh

OID (numeric): 1.3.6.1.4.1.637.3.1.5.15.25.1.10

Node type: OBJECT-TYPE

Type: INTEGER

Access: read-write

Description: This indicates the Explicit Forward Congestion Indication (EFCI) activation threshold in low priority output buffer (OB); EFCI is generated towards the receiver termination point, in order to prevent congestion situation to be encountered within the output buffer; EFCI tagging is activated as soon as the activation threshold is reached; EFCI tagging is stopped as soon as the filling of the OB is below the EFCI desactivation threshold; the EFCI desactivation threshold is equal to the activation threshold minus 1/10 of the activation threshold; the value range of the threshold is 0..adnHscBoardTrMgtLOBSize; this is only relevant for HSC board with a low priority output buffer.

What is adnHscBoardTrMgtLOBEFCIOnTh?

This configurable integer threshold specifies when EFCI congestion signals activate for low-priority output buffers. Network engineers tune this to provide early enough warning that upstream sources can reduce transmission before excessive cell loss occurs. For example, setting this to 10000 activates congestion feedback when the low-priority buffer exceeds 10000 cells.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.637.3.1.5.15.25.1.10
snmpwalk -v2c -c public <target> ADN-MIB::adnHscBoardTrMgtLOBEFCIOnTh

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.637.3.1.5.15.25.1.10.1
snmpget -v2c -c public <target> ADN-MIB::adnHscBoardTrMgtLOBEFCIOnTh.1

Set instance 1 (SNMPv2c):

snmpset -v2c -c private <target> 1.3.6.1.4.1.637.3.1.5.15.25.1.10.1 i <value>

Start monitoring Ascom Timeplex ADN multiplexers (legacy) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the ADN-MIB::adnHscBoardTrMgtLOBEFCIOnTh OID value, configure state conditions and alerts, and monitor any Ascom Timeplex ADN multiplexers (legacy) from a single console.

OID Breakdown

Upper-level ancestors (6 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
Numeric OIDNameModule
1.3.6.1.4.1.637alcatelADN-MIB
1.3.6.1.4.1.637.3adnADN-MIB
1.3.6.1.4.1.637.3.1adnMIBADN-MIB
1.3.6.1.4.1.637.3.1.5adnProprietaryADN-MIB
1.3.6.1.4.1.637.3.1.5.15adnNodeSupervisionMIBADN-MIB
1.3.6.1.4.1.637.3.1.5.15.25adnHscBoardTrMgtTableADN-MIB
1.3.6.1.4.1.637.3.1.5.15.25.1adnHscBoardTrMgtEntryADN-MIB
1.3.6.1.4.1.637.3.1.5.15.25.1.10adnHscBoardTrMgtLOBEFCIOnThADN-MIB