ADN-MIB :: adnDsx1FarEndDayIntervalUASs

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsADN-MIBadnDsx1FarEndDayIntervalUASs

adnDsx1FarEndDayIntervalUASs

Module: ADN-MIB

OID (symbolic): ADN-MIB::adnDsx1FarEndDayIntervalUASs

OID (numeric): 1.3.6.1.4.1.637.3.1.4.10.18.8.1.4

Node type: OBJECT-TYPE

Type: Gauge

Access: read-only

Description: The number of Far End Unavailable Seconds (UAS) encountered by a DS1 interface during the current day (from 0 hours to the current time).

What is adnDsx1FarEndDayIntervalUASs?

This counter measures the number of unavailable seconds (UAS) reported by the far-end equipment during today, indicating periods when the DS1 line was considered down or unusable by the remote device. An unavailable second is a 1-second interval with 10+ consecutive severely errored seconds or complete signal loss. High values here mean the remote location lost connectivity or service for extended periods.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.637.3.1.4.10.18.8.1.4
snmpwalk -v2c -c public <target> ADN-MIB::adnDsx1FarEndDayIntervalUASs

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.637.3.1.4.10.18.8.1.4.1
snmpget -v2c -c public <target> ADN-MIB::adnDsx1FarEndDayIntervalUASs.1

Start monitoring Ascom Timeplex ADN multiplexers (legacy) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the ADN-MIB::adnDsx1FarEndDayIntervalUASs OID value, configure state conditions and alerts, and monitor any Ascom Timeplex ADN multiplexers (legacy) from a single console.

OID Breakdown

Upper-level ancestors (6 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
Numeric OIDNameModule
1.3.6.1.4.1.637alcatelADN-MIB
1.3.6.1.4.1.637.3adnADN-MIB
1.3.6.1.4.1.637.3.1adnMIBADN-MIB
1.3.6.1.4.1.637.3.1.4adnExtensionsADN-MIB
1.3.6.1.4.1.637.3.1.4.10adnTransmissionADN-MIB
1.3.6.1.4.1.637.3.1.4.10.18adnDs1ADN-MIB
1.3.6.1.4.1.637.3.1.4.10.18.8adnDsx1FarEndDayIntervalTableADN-MIB
1.3.6.1.4.1.637.3.1.4.10.18.8.1adnDsx1FarEndDayIntervalEntryADN-MIB
1.3.6.1.4.1.637.3.1.4.10.18.8.1.4adnDsx1FarEndDayIntervalUASsADN-MIB