ADN-MIB :: adnDsx1FarEndDayIntervalPCVs

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsADN-MIBadnDsx1FarEndDayIntervalPCVs

adnDsx1FarEndDayIntervalPCVs

Module: ADN-MIB

OID (symbolic): ADN-MIB::adnDsx1FarEndDayIntervalPCVs

OID (numeric): 1.3.6.1.4.1.637.3.1.4.10.18.8.1.6

Node type: OBJECT-TYPE

Type: Gauge

Access: read-only

Description: The number of Far End Path Coding Violations (PCV) reported via the far end block error count en- countered by a DS1 interface during the current day (from 0 hours to the current time).

What is adnDsx1FarEndDayIntervalPCVs?

This counter accumulates the number of path coding violations (PCV) reported by the far-end equipment during today's 24-hour period, representing instances where the encoded signal received was invalid according to the DS1 line code (usually T1 AMI or B8ZS). These violations indicate that the signal quality is poor enough that the receiver cannot decode data correctly. When this metric climbs, it's a sign of electrical noise, cable damage, or improper signal levels on the transmission line.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.637.3.1.4.10.18.8.1.6
snmpwalk -v2c -c public <target> ADN-MIB::adnDsx1FarEndDayIntervalPCVs

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.637.3.1.4.10.18.8.1.6.1
snmpget -v2c -c public <target> ADN-MIB::adnDsx1FarEndDayIntervalPCVs.1

Start monitoring Ascom Timeplex ADN multiplexers (legacy) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the ADN-MIB::adnDsx1FarEndDayIntervalPCVs OID value, configure state conditions and alerts, and monitor any Ascom Timeplex ADN multiplexers (legacy) from a single console.

OID Breakdown

Upper-level ancestors (6 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
Numeric OIDNameModule
1.3.6.1.4.1.637alcatelADN-MIB
1.3.6.1.4.1.637.3adnADN-MIB
1.3.6.1.4.1.637.3.1adnMIBADN-MIB
1.3.6.1.4.1.637.3.1.4adnExtensionsADN-MIB
1.3.6.1.4.1.637.3.1.4.10adnTransmissionADN-MIB
1.3.6.1.4.1.637.3.1.4.10.18adnDs1ADN-MIB
1.3.6.1.4.1.637.3.1.4.10.18.8adnDsx1FarEndDayIntervalTableADN-MIB
1.3.6.1.4.1.637.3.1.4.10.18.8.1adnDsx1FarEndDayIntervalEntryADN-MIB
1.3.6.1.4.1.637.3.1.4.10.18.8.1.6adnDsx1FarEndDayIntervalPCVsADN-MIB