ADN-MIB :: adnDsx1FarEndDayIntervalESs

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsADN-MIBadnDsx1FarEndDayIntervalESs

adnDsx1FarEndDayIntervalESs

Module: ADN-MIB

OID (symbolic): ADN-MIB::adnDsx1FarEndDayIntervalESs

OID (numeric): 1.3.6.1.4.1.637.3.1.4.10.18.8.1.1

Node type: OBJECT-TYPE

Type: Gauge

Access: read-only

Description: The number of Far End Errored Seconds (ES) encoun- tered by a DS1 interface during the current day (from 0 hours to the current time).

What is adnDsx1FarEndDayIntervalESs?

This counter measures the cumulative far-end errored seconds from midnight to now as reported by the remote DS1 equipment. A network engineer uses this to perform end-to-end SLA calculations and to identify whether error accumulation is happening uniformly across the day or in specific periods. For example, if far-end ES is 200 by 6 PM, combined with local ES of 150, you have a network-wide quality problem that needs both facilities to investigate.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.637.3.1.4.10.18.8.1.1
snmpwalk -v2c -c public <target> ADN-MIB::adnDsx1FarEndDayIntervalESs

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.637.3.1.4.10.18.8.1.1.1
snmpget -v2c -c public <target> ADN-MIB::adnDsx1FarEndDayIntervalESs.1

Start monitoring Ascom Timeplex ADN multiplexers (legacy) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the ADN-MIB::adnDsx1FarEndDayIntervalESs OID value, configure state conditions and alerts, and monitor any Ascom Timeplex ADN multiplexers (legacy) from a single console.

OID Breakdown

Upper-level ancestors (6 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
Numeric OIDNameModule
1.3.6.1.4.1.637alcatelADN-MIB
1.3.6.1.4.1.637.3adnADN-MIB
1.3.6.1.4.1.637.3.1adnMIBADN-MIB
1.3.6.1.4.1.637.3.1.4adnExtensionsADN-MIB
1.3.6.1.4.1.637.3.1.4.10adnTransmissionADN-MIB
1.3.6.1.4.1.637.3.1.4.10.18adnDs1ADN-MIB
1.3.6.1.4.1.637.3.1.4.10.18.8adnDsx1FarEndDayIntervalTableADN-MIB
1.3.6.1.4.1.637.3.1.4.10.18.8.1adnDsx1FarEndDayIntervalEntryADN-MIB
1.3.6.1.4.1.637.3.1.4.10.18.8.1.1adnDsx1FarEndDayIntervalESsADN-MIB