All MIBs › ADN-MIB › adnAtmVclTrafficDescrType
adnAtmVclTrafficDescrType
Module: ADN-MIB
OID (symbolic): ADN-MIB::adnAtmVclTrafficDescrType
OID (numeric): 1.3.6.1.4.1.637.3.1.4.37.1.7.1.5
Node type: OBJECT-TYPE
Type: INTEGER
Access: read-only
Description: The type of Virtual Channel Link (VCL) traffic descriptor in the transmit and receiving direction. Depending on the value, certain traffic parameters must be initialized:
- 'adnAtmTrafficDescPcrCdv':
The following traffic parameters must be initialized:
adnAtmVclTrmPcrAggregate, adnAtmVclRcvPcrAggregate, adnAtmVclTrmCdvTol, adnAtmVclRcvCdvTol, adnAtmVclTrmBwWeighting, adnAtmVclRcvBwWeighting,
- 'adnAtmTrafficDescPcrCdvScrMbs':
The following traffic parameters must be initialized:
adnAtmVclTrmPcrAggregate, adnAtmVclRcvPcrAggregate, adnAtmVclTrmScrAggregate, adnAtmVclRcvScrAggregate, adnAtmVclTrmMbsAggregate, adnAtmVclRcvMbsAggregate, adnAtmVclTrmCdvTol, adnAtmVclRcvCdvTol, adnAtmVclTrmBwWeighting, adnAtmVclRcvBwWeighting.
Common Name: Traffic Descriptor
What is adnAtmVclTrafficDescrType?
This OID defines which type of traffic descriptor rules apply to a Virtual Channel Link (VCL), determining how its bandwidth and delay characteristics are described and enforced. A network engineer configures this first before setting up a VCL, since the traffic descriptor type determines which other parameters (PCR, SCR, MBS, CDV) must be initialized. For example, selecting 'adnAtmTrafficDescPcrCdv' means you must configure peak cell rate and cell delay variation tolerance values, while other descriptor types require different parameters.
Examples
Walk all instances (SNMPv2c):
snmpwalk -v2c -c public <target> 1.3.6.1.4.1.637.3.1.4.37.1.7.1.5 snmpwalk -v2c -c public <target> ADN-MIB::adnAtmVclTrafficDescrType
Get a specific instance (index 1):
snmpget -v2c -c public <target> 1.3.6.1.4.1.637.3.1.4.37.1.7.1.5.1 snmpget -v2c -c public <target> ADN-MIB::adnAtmVclTrafficDescrType.1
Start monitoring Ascom Timeplex ADN multiplexers (legacy) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the ADN-MIB::adnAtmVclTrafficDescrType OID value, configure state conditions and alerts, and monitor any Ascom Timeplex ADN multiplexers (legacy) from a single console.
OID Breakdown
Upper-level ancestors (6 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.4 | private | AirPair-MIB |
| 1.3.6.1.4.1 | enterprises | AirPair-MIB |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.637 | alcatel | ADN-MIB |
| 1.3.6.1.4.1.637.3 | adn | ADN-MIB |
| 1.3.6.1.4.1.637.3.1 | adnMIB | ADN-MIB |
| 1.3.6.1.4.1.637.3.1.4 | adnExtensions | ADN-MIB |
| 1.3.6.1.4.1.637.3.1.4.37 | adnAtmMIB | ADN-MIB |
| 1.3.6.1.4.1.637.3.1.4.37.1 | adnAtmMIBObjects | ADN-MIB |
| 1.3.6.1.4.1.637.3.1.4.37.1.7 | adnAtmVclTable | ADN-MIB |
| 1.3.6.1.4.1.637.3.1.4.37.1.7.1 | adnAtmVclEntry | ADN-MIB |
| 1.3.6.1.4.1.637.3.1.4.37.1.7.1.5 | adnAtmVclTrafficDescrType | ADN-MIB |