All MIBs › ADN-MIB › adnAtmUniVpCconnectLastChassis
adnAtmUniVpCconnectLastChassis
Module: ADN-MIB
OID (symbolic): ADN-MIB::adnAtmUniVpCconnectLastChassis
OID (numeric): 1.3.6.1.4.1.637.3.1.4.37.1.8.1.33
Node type: OBJECT-TYPE
Type: INTEGER
Access: read-only
Description: The chassis number detecting the error. This nominator, which is read only, is not significant if adnAtmUniVpCconnectCauseError is equal to 'notSignificant'.
What is adnAtmUniVpCconnectLastChassis?
This read-only value records which chassis in your multi-chassis system detected an error on a Virtual Path cross-connection, stored as an integer between roughly -2 billion and +2 billion. You'd check this when troubleshooting a failed VP connection to pinpoint exactly which physical box experienced the problem. For example, a value of '3' means chassis 3 in your stack detected the error; if it shows '0' or '-1', the field is not relevant because adnAtmUniVpCconnectCauseError is set to 'notSignificant'.
Examples
Walk all instances (SNMPv2c):
snmpwalk -v2c -c public <target> 1.3.6.1.4.1.637.3.1.4.37.1.8.1.33 snmpwalk -v2c -c public <target> ADN-MIB::adnAtmUniVpCconnectLastChassis
Get a specific instance (index 1):
snmpget -v2c -c public <target> 1.3.6.1.4.1.637.3.1.4.37.1.8.1.33.1 snmpget -v2c -c public <target> ADN-MIB::adnAtmUniVpCconnectLastChassis.1
Start monitoring Ascom Timeplex ADN multiplexers (legacy) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the ADN-MIB::adnAtmUniVpCconnectLastChassis OID value, configure state conditions and alerts, and monitor any Ascom Timeplex ADN multiplexers (legacy) from a single console.
OID Breakdown
Upper-level ancestors (6 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.4 | private | AirPair-MIB |
| 1.3.6.1.4.1 | enterprises | AirPair-MIB |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.637 | alcatel | ADN-MIB |
| 1.3.6.1.4.1.637.3 | adn | ADN-MIB |
| 1.3.6.1.4.1.637.3.1 | adnMIB | ADN-MIB |
| 1.3.6.1.4.1.637.3.1.4 | adnExtensions | ADN-MIB |
| 1.3.6.1.4.1.637.3.1.4.37 | adnAtmMIB | ADN-MIB |
| 1.3.6.1.4.1.637.3.1.4.37.1 | adnAtmMIBObjects | ADN-MIB |
| 1.3.6.1.4.1.637.3.1.4.37.1.8 | adnAtmUniVpCconnectTable | ADN-MIB |
| 1.3.6.1.4.1.637.3.1.4.37.1.8.1 | adnAtmUniVpCconnectEntry | ADN-MIB |
| 1.3.6.1.4.1.637.3.1.4.37.1.8.1.33 | adnAtmUniVpCconnectLastChassis | ADN-MIB |