| OID symbolic | OID numeric | Type | Access | Description |
| shelfDataTable | 1.3.6.1.4.1.5504.3.2.1 | | not-accessible | A table of shelf information and status for each shelf
in a PLS system. The table includes revision level,
general shelf status, and enviromental monitoring.
The maximum number of shelves in a system is 255. Shelf
0 is an invalid entry. |
| shelfDataEntry | 1.3.6.1.4.1.5504.3.2.1.1 | | not-accessible | An entry per shelf in a PLS system. The entries are
indexed by zhoneShelfIndex or the shelf number which
has a value of 1 to 255. Shelf 0 is not valid.
zhoneShelfIndex is a column in the zhoneShelfSlotTable,
defined in the zhone MIB (Zhone.mib).
An Entry in the table is automatically created when
a new shelf is added to a PLS and detected by the
operating software of the system |
| STR shelfMfgCLEICode | 1.3.6.1.4.1.5504.3.2.1.1.1 | ZhoneAdminString | read-only | CLEI (Common Language Equipment Identifier) code of the
shelf assembly as stored in the EEPROM of the unit if
defined otherwise the value will be set to NULL (0-length
string) by the shelf monitor card.
Note: CLEI codes for individual assemblies of the shelf
such as monitor card or backplane assembly are not
supported. |
| STR shelfMonitorSerialNumber | 1.3.6.1.4.1.5504.3.2.1.1.2 | ZhoneAdminString | read-only | The manufacturing serial number for the shelf monitor
card of this shelf assembly. |
| STR shelfMonitorRevisionCode | 1.3.6.1.4.1.5504.3.2.1.1.3 | ZhoneAdminString | read-only | Manufacturing hardware revision code for the shelf
monitoring card of this shelf assembly |
| STR shelfBkplaneSerialNumber | 1.3.6.1.4.1.5504.3.2.1.1.4 | ZhoneAdminString | read-only | The manufacturing serial number of the backplane in this
shelf assembly. |
| STR shelfBkplaneRevisionCode | 1.3.6.1.4.1.5504.3.2.1.1.5 | ZhoneAdminString | read-only | The manufacturing hardware revision code for the back-
plane in this shelf assembly. |
| STR shelfFanTraySerialNumber | 1.3.6.1.4.1.5504.3.2.1.1.6 | ZhoneAdminString | read-only | The manufacturing serial number for the fan tray assembly
in this shelf assembly. |
| STR shelfFanTrayRevisionCode | 1.3.6.1.4.1.5504.3.2.1.1.7 | ZhoneAdminString | read-only | The hardware revision code for the fan tray assembly in
this shelf assembly. |
| I32 shelfSlotCount | 1.3.6.1.4.1.5504.3.2.1.1.8 | Integer32 | read-only | The number of slots in this shelf |
| OCT shelfFeatureBits | 1.3.6.1.4.1.5504.3.2.1.1.9 | OCTET STRING | read-only | A string of 8 octets indicating the setting of the feature BITS. |
| ZHO shelfFanTrayType | 1.3.6.1.4.1.5504.3.2.1.1.10 | ZhoneCardType | read-only | Description. |
| T/F shelfIOAlarmBoardPresent | 1.3.6.1.4.1.5504.3.2.1.1.11 | TruthValue | read-only | Indicates that MXK I/O Alarm Board hardware
is present and supported. Not used in systems
other than MXK. |
| shelfStatusTable | 1.3.6.1.4.1.5504.3.2.2 | | not-accessible | environmental status table - this table contains the
environmental monitoring data for each shelf in a PLS. |
| shelfStatusEntry | 1.3.6.1.4.1.5504.3.2.2.1 | | not-accessible | This table augments the shelfDataTable. Each entry in
the table contains the status of the environmental
monitoring sensors on the shelf monitor card. |
| INT shelfAPowerStatus | 1.3.6.1.4.1.5504.3.2.2.1.1 | INTEGER | read-only | Status of the A power to the shelf. On systems with
multiple power sources, this entry represents the
AC power-supply status.
On systems with line-power, this entry represents
the status of power-line 1.
The status of the power is indicated as follows:
powerOk: the shelf is receiving a normal (in-range)
voltage.
powerNotOk: the shelf is not receiving voltage or
the voltage is outside of the usable range.
A trap is generated with the loss of A power. |
| INT shelfBPowerStatus | 1.3.6.1.4.1.5504.3.2.2.1.2 | INTEGER | read-only | Status of the B power to the shelf.
On systems with
multiple power sources, this entry represents the
-48 Volt DC power-supply status.
On systems with line-power, this entry represents
the status of power-line 2.
The status of the power is indicated as follows:
powerOk: the shelf is receiving a normal (in-range)
voltage.
powerNotOk: the shelf is not receiving voltage or
the voltage is outside of the usable range.
A trap is generated with the loss of A power. |
| INT shelfTemperatureStatus | 1.3.6.1.4.1.5504.3.2.2.1.3 | INTEGER | read-only | Outlet or exhaust air temperature as status.
A trap is generated if temperature leaves the normal opertioning range. |
| INT shelfFanTrayStatus | 1.3.6.1.4.1.5504.3.2.2.1.4 | INTEGER | read-only | The operational status of the shelf fan tray assembly as
follows:
Operational: the fan tray is fully operational with
all fans running.
notOperational: the fan tray assembly has failed. A high severity trap
is generated when the status is set to notOperational. |
| BIT shelfAlarmContactsStatus | 1.3.6.1.4.1.5504.3.2.2.1.5 | Bits | read-only | A BIT field of two (2) BITs indicating larm status of the dry contact alarm on
the chassis/shelf:
A value of zero(0) is returned in each BIT if the contact is open
A value of one(1) is returned if the contack is closed |
| OCT shelfCardStatus | 1.3.6.1.4.1.5504.3.2.2.1.6 | OCTET STRING | read-only | A string of octets, with one octet per card slot on
the shelf assembly. The string of octets indicates the
status of each slot in sequence with the first octet
describing first slot. The encoding of each octet is as
follows:
1: card is booting from eeprom
2: card is performing post tests
3: card is loading code from code loader
4: card is configuing
5: card is running
6: card is blocked from booting
7: card is dumping fatal data
8: card is in faulted
9: card is reseting
10: slot is empty
11: slot is not provisioned
12: card is disabled
13: card is powered down
14: card is powered up
15: card is uplink with active traffic
16: card is uplink without active traffic |
| BIT shelfLedStatus | 1.3.6.1.4.1.5504.3.2.2.1.7 | Bits | read-only | A BIT field of six(6) BITs indicating the status of the
LEDs on the chassis bezel. A value of zero(0) is
returned in each BIT if the LED is off, a value of one(1)
is returned if the LED is lit. |
| G32 shelfAdminResets | 1.3.6.1.4.1.5504.3.2.2.1.8 | Gauge32 | read-only | Count of the number of administration resets
to a shelf such as systemreboot. |
| G32 shelfFaultResets | 1.3.6.1.4.1.5504.3.2.2.1.9 | Gauge32 | read-only | Count of the number of shelf resets due to faults. |
| G32 shelfPowerResets | 1.3.6.1.4.1.5504.3.2.2.1.10 | Gauge32 | read-only | Count of the number of shelf resets due to power
failure or power cycle. |
| INT shelfCPowerStatus | 1.3.6.1.4.1.5504.3.2.2.1.11 | INTEGER | read-only | Status of the C power to the shelf. On systems with
multiple power sources, this entry represents the
line-power power-supply status.
On systems with line-power, this entry represents
the status of power-line 3.
The status of the power is indicated as follows:
powerOk: the shelf is receiving a normal (in-range)
voltage.
powerNotOk: the shelf is not receiving voltage or
the voltage is outside of the usable range.
A trap is generated with the loss of A power. |
| INT shelfDPowerStatus | 1.3.6.1.4.1.5504.3.2.2.1.12 | INTEGER | read-only | Status of the D power to the shelf.
On systems with line-power, this entry represents
the status of power-line 4.
The status of the power is indicated as follows:
powerOk: the shelf is receiving a normal (in-range)
voltage.
powerNotOk: the shelf is not receiving voltage or
the voltage is outside of the usable range.
A trap is generated with the loss of A power. |
| STR shelfBatteryAVoltage | 1.3.6.1.4.1.5504.3.2.2.1.13 | ZhoneAdminString | read-only | Battery A voltage measurement. |
| STR shelfBatteryBVoltage | 1.3.6.1.4.1.5504.3.2.2.1.14 | ZhoneAdminString | read-only | Battery B voltage measurement. |
| STR shelfChassisReturnVoltage | 1.3.6.1.4.1.5504.3.2.2.1.15 | ZhoneAdminString | read-only | Chassis return voltage. |
| shelfFanTable | 1.3.6.1.4.1.5504.3.2.3 | | not-accessible | A table of information about the fans on the shelf.
Currently a BAN has 8 fans and a MALC has 3 fans. |
| shelfFanEntry | 1.3.6.1.4.1.5504.3.2.3.1 | | not-accessible | Description. |
| I32 shelfFanIndex | 1.3.6.1.4.1.5504.3.2.3.1.1 | Integer32 | not-accessible | An index into the fan table. It is index from
1..Number of fans with no missing indicies. |
| I32 shelfFanSpeed | 1.3.6.1.4.1.5504.3.2.3.1.2 | Integer32 | read-only | Fan speed of the fan in RPM |
| STR shelfFanLocation | 1.3.6.1.4.1.5504.3.2.3.1.3 | ZhoneAdminString | read-only | Description of the location of the fan in the fan tray |
| I32 shelfFanLowSpeedThreshold | 1.3.6.1.4.1.5504.3.2.3.1.4 | Integer32 | read-only | The lower speed allowed for a fan before it is considered failed. |
| shelfTemperatureTable | 1.3.6.1.4.1.5504.3.2.4 | | not-accessible | A table of information about the temperature sensors
in the shelf. |
| shelfTemperatureEntry | 1.3.6.1.4.1.5504.3.2.4.1 | | not-accessible | Description. |
| I32 shelfTemperatureIndex | 1.3.6.1.4.1.5504.3.2.4.1.1 | Integer32 | not-accessible | An index into the temperature table. It is index
1..Number of temperature sensors with no missing indicies. |
| I32 shelfTemperature | 1.3.6.1.4.1.5504.3.2.4.1.2 | Integer32 | read-only | The temperature of a shelf at this position. |
| STR shelfTemperatureLocation | 1.3.6.1.4.1.5504.3.2.4.1.3 | ZhoneAdminString | read-only | The location of the this temperature sensors. |
| I32 shelfTemperatureHighThreshold | 1.3.6.1.4.1.5504.3.2.4.1.4 | Integer32 | read-only | The upper temperature when an alarm will be sent. |
| I32 shelfTemperatureLowThreshold | 1.3.6.1.4.1.5504.3.2.4.1.5 | Integer32 | read-only | The lower temperature that an alarm will be sent. |
| shelfCardTable | 1.3.6.1.4.1.5504.3.2.5 | | not-accessible | A table of card information for each shelf in a PLS
system. The includes different counts of resets for
each card and the card type for each slot. |
| shelfCardEntry | 1.3.6.1.4.1.5504.3.2.5.1 | | not-accessible | An entry per slot and shelf in a PLS system.
The entries are indexed by zhoneShelfIndex/zhoneSlotIndex. |
| ZHO cardType | 1.3.6.1.4.1.5504.3.2.5.1.1 | ZhoneCardType | read-only | The card type for the card in this slot. |
| ZHO cardSubType | 1.3.6.1.4.1.5504.3.2.5.1.2 | ZhoneCardType | read-only | The card sub type for this slot |
| ZHO cardLineType | 1.3.6.1.4.1.5504.3.2.5.1.3 | ZhoneCardLineType | read-only | The card line type for this slot. This is only valid if the slot is provisioned. |
| STR cardVersion | 1.3.6.1.4.1.5504.3.2.5.1.4 | ZhoneAdminString | read-only | The card version for the card in this slot. |
| STR cardEepromVersion | 1.3.6.1.4.1.5504.3.2.5.1.5 | ZhoneAdminString | read-only | The eeprom version for the card in this slot. |
| STR cardSerialNumber | 1.3.6.1.4.1.5504.3.2.5.1.6 | ZhoneAdminString | read-only | The serial number for the card in this slot. |
| STR cardCLEICode | 1.3.6.1.4.1.5504.3.2.5.1.7 | ZhoneAdminString | read-only | CLEI (Common Language Equipment Identifier) code of the
shelf assembly as stored in the EEPROM of the unit if
defined otherwise the value will be set to NULL (0-length
string) by the shelf monitor card. |
| OCT cardFeatureBits | 1.3.6.1.4.1.5504.3.2.5.1.8 | OCTET STRING | read-only | A string of 8 octets indicating the setting of the feature BITS. |
| INT cardState | 1.3.6.1.4.1.5504.3.2.5.1.9 | INTEGER | read-only | The card state for the card in this slot.
cardStateBooting card is booting from eeprom
cardStatePost card is performing post tests
cardStateLoading card is loading code from code loader
cardStateConfiguring card is configuing
cardStateRunning card is running
cardStateResetHold card is blocked from booting
cardStateDumping
cardStateFault card is in faulted
cardStateReset card is reseting
cardNotPresent card is not present in slot
cardNotProvisioned card in slot is not provisioned |
| G32 cardAdminResets | 1.3.6.1.4.1.5504.3.2.5.1.10 | Gauge32 | read-only | Count of the number of administration resets to this
card. |
| G32 cardFaultResets | 1.3.6.1.4.1.5504.3.2.5.1.11 | Gauge32 | read-only | Count of number of fault resets to this card. |
| T/F cardReboot | 1.3.6.1.4.1.5504.3.2.5.1.12 | TruthValue | read-write | When set to true, this card will be rebooted.
Error cases:
(a) If the card is not present, a set results in an
INCONSISTENT_VALUE error.
(b) An attempt to set to false results in a
WRONG_VALUE error.
All gets will return a value of false.
This is supported only on systems with a supervisory
bus, such as BAN & MALC. |
| INT zhoneShelfStatus | 1.3.6.1.4.1.5504.3.2.7 | INTEGER | read-only | This variable is set by the ShelfMonitor when the
shelf state changes. |
| INT zhoneCardStatus | 1.3.6.1.4.1.5504.3.2.8 | INTEGER | read-only | This variable is set by the ShelfMonitor whenever the
card state changes. |
| TIM zhoneShelfStatusLastChange | 1.3.6.1.4.1.5504.3.2.10 | TimeStamp | read-only | The time the shelf status changed. |
| TIM zhoneCardStatusLastChange | 1.3.6.1.4.1.5504.3.2.11 | TimeStamp | read-only | The time the card status last changed. |
| zhoneTrapShelfMonitorV2Traps | 1.3.6.1.4.1.5504.3.2.12 | | | ShelfMonitor Trap. |
| zhoneTrapShelfMonitorGroup | 1.3.6.1.4.1.5504.3.2.12.1 | | | Description. |
| NTF zhoneTrapShelfStatusChange | 1.3.6.1.4.1.5504.3.2.12.2 | | | Shelf status reported by the ShelfMonitor. |
| NTF zhoneTrapCardStatusChange | 1.3.6.1.4.1.5504.3.2.12.3 | | | Card status reported by the ShelfMonitor. |
| NTF zhoneTrapCardVersionCheck | 1.3.6.1.4.1.5504.3.2.12.4 | | | When the cardVersion of a card is incompatible with that
of active InfoServ card, this trap is generated. Currently,
this is only supported on BAN platform and its card versions
are described as follows:
The revision number of the newer 40 Mhz cards is in the range
of 'BA' to 'CV'.
Older card version either does not display in this format or
the revision number is not in this range.
For example, for a card with cardVersion '840-29496-72-CR',
the revision number is 'CR' and is a new 40 Mhz card. |
| NTF zhoneTrapFlashCardStatusChange | 1.3.6.1.4.1.5504.3.2.12.5 | | | This Trap reports the FlashCard status change for the InfoServ slots
flash cards within BAN shelf. |
| NTF zhoneTrapCardToBkplaneStatusChange | 1.3.6.1.4.1.5504.3.2.12.6 | | | Mxk line card link to backplane status. |
| zhoneShelfStatusGroup | 1.3.6.1.4.1.5504.3.2.13 | | | These objects are used to identify the status change
of the trap. |
| zhoneStatusLastChangeGroup | 1.3.6.1.4.1.5504.3.2.14 | | | Description. |
| zhoneCardStatusGroup | 1.3.6.1.4.1.5504.3.2.15 | | | Description. |
| INT zhoneFlashCardStatusChange | 1.3.6.1.4.1.5504.3.2.16 | INTEGER | accessible-for-notify | The FlashCardStatus reports the status of the flash card ports on the
InfoServe cards within BAN shelf.
1 : FlashCard Port 1 is Installed
2 : FlashCard Port 1 is Removed
3 : FlashCard Port 2 is Installed
4 : FlashCard Port 2 is Removed |
| INT zhoneCardLinkToBkplaneStatus | 1.3.6.1.4.1.5504.3.2.17 | INTEGER | accessible-for-notify | Mxk linecard Link To Backplane status. |
| zhoneShelfMonitorModule | 1.3.6.1.4.1.5504.6.7 | | | Contains the elements that are monitored on a per
shelf basis in the PLS. |