All MIBs › VIDEOFRAME-SIGMON-VM0006-MIB
Organization: Videoframe Systems
Last Updated: 2001-09-11
Category: Videoframe Broadcast Monitoring
Description: Monitors Videoframe VM0006 module signal status and fault detection in broadcast environments.
Start monitoring vendor-neutral, standards-based MIB, any SNMPv3-capable network device (SNMP engine identity/boot/clock status) with a free 30-day trial of IPNetwork Monitor. Import MIBs, browse SNMP OIDs, create custom SNMP monitors, configure alerts, and monitor any SNMP-enabled network device from a single console.
What Is VIDEOFRAME-SIGMON-VM0006-MIB?
This is a Videoframe Systems vendor MIB for the VM0006 GPI (General Purpose Interface) module, a broadcast signal-monitoring card that augments MIB-2, the VF-GENERIC MIB, and the VF-SIGMON MIB to identify and manage this specific device within Videoframe's signal monitoring product line. It exposes per-slot hardware inventory (slot number, active/locate status) and per-GPI-signal state data across the module's GPI interface. It is primarily a hardware-status monitoring MIB for broadcast facilities — vm0006Active and vm0006Locate reveal whether a specific rack-mounted module is present/active or has been flagged via its physical locate indicator, while vm0006GPISignalState reports the real-time state of each GPI contact/tally signal used for equipment control or on-air indication. It explicitly depends on and augments MIB-2 (the standard system/interfaces MIB) along with Videoframe's own VF-GENERIC and VF-SIGMON MIBs for shared identification and signal-monitoring conventions. It is typically deployed in broadcast master control rooms or transmission facilities using Videoframe rack-mounted signal monitoring gear with GPI-based tally/control interfacing. Engineers can download the VIDEOFRAME-SIGMON-VM0006-MIB file directly to load it into their MIB browser.
IPNetwork Monitor allows you to monitor SNMP objects defined in VIDEOFRAME-SIGMON-VM0006-MIB. Use the built-in SNMP Monitoring Browser to explore available variables, view their current values and descriptions, and select the objects you want to monitor. You can then create SNMP monitors, configure thresholds, and receive alerts when monitored values change.
Supported Devices
- Videoframe Systems VM0006 GPI interface module (broadcast rack equipment)
Monitoring Examples
An administrator would poll vm0006Table/vm0006Entry indexed by vm0006SlotNumber to confirm a given module is vm0006Active, then walk vm0006GPISignalTable/vm0006GPISignalEntry using vm0006GPISignalNumber to read vm0006GPISignalState for each named GPI contact (identified via vm0006GPISignalName) — an unexpected state change here, combined with vm0006GPIInterfaceEvents notifications, would flag a tally or GPI-triggered event such as an on-air/off-air transition or an external alarm contact closure.
What Can Be Monitored
- module slot active/locate status
- GPI signal state per contact
- GPI interface events
- GPI signal naming/identification
Imported Objects
From RFC1155-SMI
| OBJECT-TYPE |
From SNMPv2-CONF
| MODULE-COMPLIANCE | |
| OBJECT-GROUP |
From SNMPv2-SMI
| IpAddress | |
| MODULE-IDENTITY | |
| NOTIFICATION-TYPE | |
| OBJECT-IDENTITY |
From SNMPv2-TC
| DisplayString | |
| RowStatus |
| vfBoxId | OBJECT-TYPE |
From VIDEOFRAME-REGISTRATIONS-MIB
| vfMIBModules | OBJECT-IDENTITY |
| vfFrameSlotNumber | OBJECT-TYPE |
| vfProductsVF200Reg | OBJECT-IDENTITY |
| vfSigmonFrameModuleTypes | OBJECT-IDENTITY |
How to Use in IPNetwork Monitor
Example using vm0006Active OID:
OIDs
RFC description
Manages GPI signal monitoring and control on VideoFrame Sigmon VM0006 HFC network elements in cable systems.
Start monitoring Videoframe Systems VM0006 GPI interface module, broadcast rack equipment (module active/GPI-signal-state status) with a free 30-day trial of IPNetwork Monitor. Import MIBs, browse SNMP OIDs, create custom SNMP monitors, configure alerts, and monitor any SNMP-enabled network device from a single console.