All MIBs › VERTIV-V5-MIB
Organization: Vertiv
Last Updated: 2020-01-07
Category: Power and Environmental Monitoring
Description: Tracks Vertiv V5 power and cooling infrastructure, including UPS units, PDUs, and thermal management.
Start monitoring vendor-neutral, standards-based MIB, any SNMPv3-capable network device (SNMP engine identity/boot/clock status) with a free 30-day trial of IPNetwork Monitor. Import MIBs, browse SNMP OIDs, create custom SNMP monitors, configure alerts, and monitor any SNMP-enabled network device from a single console.
What Is VERTIV-V5-MIB?
VERTIV-V5-MIB is a vendor MIB from Vertiv (formerly Emerson Network Power) covering the "V5" product platform, used to manage power and cooling infrastructure such as UPS, PDU, and thermal management units. It exposes device identity and inventory data (product title, version, model, part and serial numbers, MAC address, hostname, platform) alongside environmental data such as temperature units and device counts. Its monitoring role centers on hardware/software status of the power/cooling device itself — firmware/software version tracking via productVersion, hardware identification via productSerialNumber/productModelNumber, and environmental conditions via temperature-related objects, useful for verifying device identity and health during fleet management. No explicit dependency on other MIBs is indicated; it appears to be a self-contained vendor MIB. It is typically deployed on Vertiv UPS, PDU, and precision cooling/thermal management units in data center and telecom facilities. Network engineers evaluating or troubleshooting this functionality can download the VERTIV-V5-MIB file directly to load it into their MIB browser.
IPNetwork Monitor allows you to monitor SNMP objects defined in VERTIV-V5-MIB. Use the built-in SNMP Monitoring Browser to explore available variables, view their current values and descriptions, and select the objects you want to monitor. You can then create SNMP monitors, configure thresholds, and receive alerts when monitored values change.
Supported Devices
- Vertiv UPS units
- Vertiv PDUs
- Vertiv precision cooling/thermal management systems
Monitoring Examples
An administrator would poll productFriendlyName, productModelNumber, productSerialNumber, and productVersion under deviceInfo to confirm firmware version and hardware identity of a Vertiv V5 unit, and check temperatureUnits together with deviceCount to validate the number of managed sub-devices reporting into the imd (intelligent monitoring device) subtree. A mismatch between expected productVersion and the polled value would flag a unit running outdated firmware needing an update.
What Can Be Monitored
- product/firmware version
- product model and serial number
- device hostname and MAC address
- temperature units
- managed device count
This MIB depends on
Related MIBs
Imported Objects
From SNMP-FRAMEWORK-MIB
| SnmpAdminString |
From SNMPv2-MIB
| sysName | OBJECT-TYPE |
From SNMPv2-SMI
| Gauge32 | |
| Integer32 | |
| MODULE-IDENTITY | |
| NOTIFICATION-TYPE | |
| OBJECT-IDENTITY | |
| OBJECT-TYPE | |
| enterprises |
From SNMPv2-TC
| DisplayString | |
| MacAddress | |
| TruthValue |
How to Use in IPNetwork Monitor
Example using pduMainAvail OID:
OIDs
| OID symbolic | OID numeric | Type | Access | Description |
|---|---|---|---|---|
| vertiv | 1.3.6.1.4.1.21239 | The MIB for Vertiv products | ||
| v5 | 1.3.6.1.4.1.21239.5 | |||
| imd | 1.3.6.1.4.1.21239.5.2 | |||
| deviceInfo | 1.3.6.1.4.1.21239.5.2.1 | |||
| STR productTitle | 1.3.6.1.4.1.21239.5.2.1.1 | SnmpAdminString | read-only | Product name |
| STR productVersion | 1.3.6.1.4.1.21239.5.2.1.2 | SnmpAdminString | read-only | Product version |
| STR productFriendlyName | 1.3.6.1.4.1.21239.5.2.1.3 | SnmpAdminString | read-only | User-assigned name |
| MAC productMacAddress | 1.3.6.1.4.1.21239.5.2.1.4 | MacAddress | read-only | Product's unique MAC address |
| I32 deviceCount | 1.3.6.1.4.1.21239.5.2.1.6 | Integer32 | read-only | Total number of devices on unit |
| INT temperatureUnits | 1.3.6.1.4.1.21239.5.2.1.7 | INTEGER | read-write | Current units for temperature/dewpoint values: 0 = Degrees Fahrenheit 1 = Degrees Celsius |
| STR productModelNumber | 1.3.6.1.4.1.21239.5.2.1.8 | SnmpAdminString | read-only | Product model number (factory-assigned) |
| STR productPartNumber | 1.3.6.1.4.1.21239.5.2.1.9 | SnmpAdminString | read-only | Product part number (factory-assigned) |
| STR productSerialNumber | 1.3.6.1.4.1.21239.5.2.1.10 | SnmpAdminString | read-only | Product serial number (factory-assigned) |
| STR productPlatform | 1.3.6.1.4.1.21239.5.2.1.11 | SnmpAdminString | read-only | Product platform |
| STR productHostname | 1.3.6.1.4.1.21239.5.2.1.12 | SnmpAdminString | read-only | Product hostname |
| I32 productAlarmCount | 1.3.6.1.4.1.21239.5.2.1.13 | Integer32 | read-only | Number of alarms currently tripped |
| I32 productWarnCount | 1.3.6.1.4.1.21239.5.2.1.14 | Integer32 | read-only | Number of warnings currently tripped |
| STR productManufacturer | 1.3.6.1.4.1.21239.5.2.1.15 | SnmpAdminString | read-only | Product manufacturer |
| pdu | 1.3.6.1.4.1.21239.5.2.3 | |||
| pduMainTable | 1.3.6.1.4.1.21239.5.2.3.1 | not-accessible | PDU general information | |
| pduMainEntry | 1.3.6.1.4.1.21239.5.2.3.1.1 | not-accessible | Entry in the pduMainTable table: each entry contains an index and other sensor details | |
| I32 pduMainIndex | 1.3.6.1.4.1.21239.5.2.3.1.1.1 | Integer32 | not-accessible | Table entry index value |
| STR pduMainSerial | 1.3.6.1.4.1.21239.5.2.3.1.1.2 | DisplayString | read-only | Serial number |
| STR pduMainName | 1.3.6.1.4.1.21239.5.2.3.1.1.3 | SnmpAdminString | read-only | PDU name (factory-assigned) |
| STR pduMainLabel | 1.3.6.1.4.1.21239.5.2.3.1.1.4 | SnmpAdminString | read-write | PDU label (user-defined) |
| G32 pduMainAvailEx | 1.3.6.1.4.1.21239.5.2.3.1.1.5 | Gauge32 | read-only | Device availability: 0 = Unavailable 1 = Available 2 = Partially Unavailable |
| INT pduMeterType | 1.3.6.1.4.1.21239.5.2.3.1.1.6 | INTEGER | read-only | Current meter type: 0 = Wye 1 = Delta |
| STR pduTotalName | 1.3.6.1.4.1.21239.5.2.3.1.1.7 | SnmpAdminString | read-only | Total name (factory-assigned) |
| STR pduTotalLabel | 1.3.6.1.4.1.21239.5.2.3.1.1.8 | SnmpAdminString | read-write | Total label (user-defined) |
| G32 pduTotalRealPower | 1.3.6.1.4.1.21239.5.2.3.1.1.9 | Gauge32 | read-only | PDU total real power |
| G32 pduTotalApparentPower | 1.3.6.1.4.1.21239.5.2.3.1.1.10 | Gauge32 | read-only | PDU total apparent power |
| G32 pduTotalPowerFactor | 1.3.6.1.4.1.21239.5.2.3.1.1.11 | Gauge32 | read-only | PDU total power factor |
| G32 pduTotalEnergy | 1.3.6.1.4.1.21239.5.2.3.1.1.12 | Gauge32 | read-only | PDU total accumulated energy in watt-hours |
| pduPhaseTable | 1.3.6.1.4.1.21239.5.2.3.2 | not-accessible | PDU phases information | |
| pduPhaseEntry | 1.3.6.1.4.1.21239.5.2.3.2.1 | not-accessible | Entry in the pduPhaseTable table: each entry contains an index and other sensor details | |
| I32 pduPhaseIndex | 1.3.6.1.4.1.21239.5.2.3.2.1.1 | Integer32 | not-accessible | Table entry index value |
| STR pduPhaseName | 1.3.6.1.4.1.21239.5.2.3.2.1.2 | SnmpAdminString | read-only | PDU phase name (factory-assigned) |
| STR pduPhaseLabel | 1.3.6.1.4.1.21239.5.2.3.2.1.3 | SnmpAdminString | read-write | PDU phase label (user-defined) |
| G32 pduPhaseVoltage | 1.3.6.1.4.1.21239.5.2.3.2.1.4 | Gauge32 | read-only | PDU phase voltage in tenths of a volt |
| G32 pduPhaseCurrent | 1.3.6.1.4.1.21239.5.2.3.2.1.8 | Gauge32 | read-only | PDU phase current reading in hundredths of an amp |
| G32 pduPhaseRealPower | 1.3.6.1.4.1.21239.5.2.3.2.1.12 | Gauge32 | read-only | Real power for phase in watts |
| G32 pduPhaseApparentPower | 1.3.6.1.4.1.21239.5.2.3.2.1.13 | Gauge32 | read-only | Apparent power for phase in volt-amps |
| G32 pduPhasePowerFactor | 1.3.6.1.4.1.21239.5.2.3.2.1.14 | Gauge32 | read-only | Power factor for phase |
| G32 pduPhaseEnergy | 1.3.6.1.4.1.21239.5.2.3.2.1.15 | Gauge32 | read-only | Accumulated energy for phase in watt-hours |
| G32 pduPhaseBalance | 1.3.6.1.4.1.21239.5.2.3.2.1.17 | Gauge32 | read-only | Phase balance as percent |
| G32 pduPhaseCurrentCrestFactor | 1.3.6.1.4.1.21239.5.2.3.2.1.19 | Gauge32 | read-only | Current crest factor for phase, in hundredths |
| pduBreakerTable | 1.3.6.1.4.1.21239.5.2.3.3 | not-accessible | PDU breaker information | |
| pduBreakerEntry | 1.3.6.1.4.1.21239.5.2.3.3.1 | not-accessible | Entry in the pduBreakerTable table: each entry contains an index and other sensor details | |
| I32 pduBreakerIndex | 1.3.6.1.4.1.21239.5.2.3.3.1.1 | Integer32 | not-accessible | Table entry index value |
| STR pduBreakerName | 1.3.6.1.4.1.21239.5.2.3.3.1.2 | SnmpAdminString | read-only | PDU breaker name (factory-assigned) |
| STR pduBreakerLabel | 1.3.6.1.4.1.21239.5.2.3.3.1.3 | SnmpAdminString | read-write | PDU breaker label (user-defined) |
| G32 pduBreakerCurrent | 1.3.6.1.4.1.21239.5.2.3.3.1.4 | Gauge32 | read-only | PDU breaker current reading in hundredths of an amp |
| G32 pduBreakerVoltage | 1.3.6.1.4.1.21239.5.2.3.3.1.8 | Gauge32 | read-only | PDU breaker voltage in tenths of a volt. This object may not exist on all platforms, due to hardware differences. |
| G32 pduBreakerRealPower | 1.3.6.1.4.1.21239.5.2.3.3.1.12 | Gauge32 | read-only | Real power for breaker in watts. This object may not exist on all platforms, due to hardware differences. |
| G32 pduBreakerApparentPower | 1.3.6.1.4.1.21239.5.2.3.3.1.13 | Gauge32 | read-only | Apparent power for breaker in volt-amps. This object may not exist on all platforms, due to hardware differences. |
| G32 pduBreakerPowerFactor | 1.3.6.1.4.1.21239.5.2.3.3.1.14 | Gauge32 | read-only | Power factor for breaker. This object may not exist on all platforms, due to hardware differences. |
| G32 pduBreakerEnergy | 1.3.6.1.4.1.21239.5.2.3.3.1.15 | Gauge32 | read-only | Accumulated energy for breaker in watt-hours. This object may not exist on all platforms, due to hardware differences. |
| pduLineTable | 1.3.6.1.4.1.21239.5.2.3.4 | not-accessible | PDU line current information | |
| pduLineEntry | 1.3.6.1.4.1.21239.5.2.3.4.1 | not-accessible | Entry in the pduLineTable table: each entry contains an index and other sensor details | |
| I32 pduLineIndex | 1.3.6.1.4.1.21239.5.2.3.4.1.1 | Integer32 | not-accessible | Table entry index value |
| STR pduLineName | 1.3.6.1.4.1.21239.5.2.3.4.1.2 | SnmpAdminString | read-only | PDU line name (factory-assigned) |
| STR pduLineLabel | 1.3.6.1.4.1.21239.5.2.3.4.1.3 | SnmpAdminString | read-write | PDU line label (user-defined) |
| G32 pduLineCurrent | 1.3.6.1.4.1.21239.5.2.3.4.1.4 | Gauge32 | read-only | PDU line current reading in hundredths of an amp |
| pduOutletSwitchTable | 1.3.6.1.4.1.21239.5.2.3.5 | not-accessible | Data, config and control for outlets with switching | |
| pduOutletSwitchEntry | 1.3.6.1.4.1.21239.5.2.3.5.1 | not-accessible | Entry in the pduOutletSwitchTable table: each entry contains an index and other sensor details | |
| I32 pduOutletSwitchIndex | 1.3.6.1.4.1.21239.5.2.3.5.1.1 | Integer32 | not-accessible | Table entry index value |
| STR pduOutletSwitchName | 1.3.6.1.4.1.21239.5.2.3.5.1.2 | SnmpAdminString | read-only | PDU outlet name (factory-assigned) |
| STR pduOutletSwitchLabel | 1.3.6.1.4.1.21239.5.2.3.5.1.3 | SnmpAdminString | read-write | PDU outlet label (user-defined) |
| INT pduOutletSwitchState | 1.3.6.1.4.1.21239.5.2.3.5.1.4 | INTEGER | read-only | Switch state of the outlet: 1 = Outlet is on 2 = Outlet is off 3 = Outlet is on, but will turn off after a delay 4 = Outlet is off, but will turn on after a delay 5 = Starting reboot cycle, outlet is on, but will go to the rebootOff(6) state after a delay 6 = Rebooting, outlet is off, but it will turn on after a delay 7 = Cannot get outlet state |
| T/F pduOutletSwitchRelayFailure | 1.3.6.1.4.1.21239.5.2.3.5.1.5 | TruthValue | read-only | Tells if the outlet relay has failed. In normal operation, the value will be false(2). |
| INT pduOutletSwitchControl | 1.3.6.1.4.1.21239.5.2.3.5.1.6 | INTEGER | read-write | Used for manual control of the outlet. If the outlet is in manual mode, this field can be set to one of the following values: 1 = Cancel pending operation 2 = Turn outlet on 3 = After delay (pduOutletSwitchOnDelay), turn outlet on 4 = Turn outlet off 5 = After delay (pduOutletSwitchOffDelay), turn outlet off 6 = Reboot: turn off, delay (pduOutletSwitchRebootHoldDelay), turn outlet back on 7 = After delay (pduOutletSwitchRebootDelay), reboot outlet When not in manual mode, setting this field will give an inconsistentValue error. Returns none(8) for all get requests. |
| I32 pduOutletSwitchTimeToAction | 1.3.6.1.4.1.21239.5.2.3.5.1.7 | Integer32 | read-only | Seconds until an outlet state change. The value of pduOutletSwitchState tells what state the outlet will be set, after the delay. |
| I32 pduOutletSwitchOnDelay | 1.3.6.1.4.1.21239.5.2.3.5.1.8 | Integer32 | read-write | Seconds to wait before powering on the outlet, during onAfterDelay(3) operation. Changing this value has no effect on pending actions. |
| I32 pduOutletSwitchOffDelay | 1.3.6.1.4.1.21239.5.2.3.5.1.9 | Integer32 | read-write | Seconds to wait before powering off the outlet, during offAfterDelay(5) operation. Changing this value has no effect on pending actions. |
| I32 pduOutletSwitchRebootDelay | 1.3.6.1.4.1.21239.5.2.3.5.1.10 | Integer32 | read-write | Seconds to wait before powering off the outlet, during rebootAfterDelay(7) operation. Changing this value has no effect on pending actions. See pduOutletSwitchControl for more info. |
| I32 pduOutletSwitchRebootHoldDelay | 1.3.6.1.4.1.21239.5.2.3.5.1.11 | Integer32 | read-write | Seconds to hold the outlet off, before powering on the outlet, during rebootAfterDelay(7) operation. Changing this value has no effect on pending actions. See pduOutletSwitchControl for more info. |
| INT pduOutletSwitchPoaAction | 1.3.6.1.4.1.21239.5.2.3.5.1.12 | INTEGER | read-write | The outlet is set to this state during power-up. The action can be have one the following values: 1 = Outlet will be turned on 2 = Outlet will stay off 3 = Outlet will be set to last known state |
| I32 pduOutletSwitchPoaDelay | 1.3.6.1.4.1.21239.5.2.3.5.1.13 | Integer32 | read-write | Seconds to wait before setting the outlet to the pduOutletSwitchPoaAction state. The delay starts at power-up. |
| pduOutletMeterTable | 1.3.6.1.4.1.21239.5.2.3.6 | not-accessible | Metering data for outlets that support this feature | |
| pduOutletMeterEntry | 1.3.6.1.4.1.21239.5.2.3.6.1 | not-accessible | Entry in the pduOutletMeterTable table: each entry contains an index and other sensor details | |
| I32 pduOutletMeterIndex | 1.3.6.1.4.1.21239.5.2.3.6.1.1 | Integer32 | not-accessible | Table entry index value |
| STR pduOutletMeterName | 1.3.6.1.4.1.21239.5.2.3.6.1.2 | SnmpAdminString | read-only | PDU outlet name (factory-assigned) |
| STR pduOutletMeterLabel | 1.3.6.1.4.1.21239.5.2.3.6.1.3 | SnmpAdminString | read-write | PDU outlet label (user-defined) |
| G32 pduOutletMeterVoltage | 1.3.6.1.4.1.21239.5.2.3.6.1.4 | Gauge32 | read-only | PDU outlet voltage in tenths of a volt |
| G32 pduOutletMeterCurrent | 1.3.6.1.4.1.21239.5.2.3.6.1.8 | Gauge32 | read-only | PDU outlet current reading in hundredths of an amp |
| G32 pduOutletMeterRealPower | 1.3.6.1.4.1.21239.5.2.3.6.1.12 | Gauge32 | read-only | Real power for outlet in watts |
| G32 pduOutletMeterApparentPower | 1.3.6.1.4.1.21239.5.2.3.6.1.13 | Gauge32 | read-only | Apparent power for outlet in volt-amps |
| G32 pduOutletMeterPowerFactor | 1.3.6.1.4.1.21239.5.2.3.6.1.14 | Gauge32 | read-only | Power factor for outlet |
| G32 pduOutletMeterEnergy | 1.3.6.1.4.1.21239.5.2.3.6.1.15 | Gauge32 | read-only | Accumulated energy for outlet in watt-hours |
| INT pduOutletMeterReset | 1.3.6.1.4.1.21239.5.2.3.6.1.16 | INTEGER | read-write | Used to reset energy. If read, the value is none(8). It can be set to resetEnergy(1), which sets outlet energy to 0 |
| G32 pduOutletCurrentCrestFactor | 1.3.6.1.4.1.21239.5.2.3.6.1.19 | Gauge32 | read-only | Current crest factor for outlet, in hundredths |
| tempSensorTable | 1.3.6.1.4.1.21239.5.2.4 | not-accessible | Remote Temperature (RT) sensor | |
| tempSensorEntry | 1.3.6.1.4.1.21239.5.2.4.1 | not-accessible | Entry in the tempSensorTable table: each entry contains an index and other sensor details | |
| I32 tempSensorIndex | 1.3.6.1.4.1.21239.5.2.4.1.1 | Integer32 | not-accessible | Table entry index value |
| STR tempSensorSerial | 1.3.6.1.4.1.21239.5.2.4.1.2 | DisplayString | read-only | Serial number |
| STR tempSensorLabel | 1.3.6.1.4.1.21239.5.2.4.1.3 | SnmpAdminString | read-write | User-defined label |
| G32 tempSensorAvail | 1.3.6.1.4.1.21239.5.2.4.1.4 | Gauge32 | read-only | Device availability: 0 = Unavailable 1 = Available 2 = Partially Unavailable |
| I32 tempSensorTemp | 1.3.6.1.4.1.21239.5.2.4.1.5 | Integer32 | read-only | Temperature in tenths of a degree. Units are given by temperatureUnits field in deviceInfo. |
| airFlowSensorTable | 1.3.6.1.4.1.21239.5.2.5 | not-accessible | Remote Airflow, Humidity, Temperature and Dewpoint (AFHT3) Sensor | |
| airFlowSensorEntry | 1.3.6.1.4.1.21239.5.2.5.1 | not-accessible | Entry in the airFlowSensorTable table: each entry contains an index and other sensor details | |
| I32 airFlowSensorIndex | 1.3.6.1.4.1.21239.5.2.5.1.1 | Integer32 | not-accessible | Table entry index value |
| STR airFlowSensorSerial | 1.3.6.1.4.1.21239.5.2.5.1.2 | DisplayString | read-only | Serial number |
| STR airFlowSensorLabel | 1.3.6.1.4.1.21239.5.2.5.1.3 | SnmpAdminString | read-write | User-defined label |
| G32 airFlowSensorAvail | 1.3.6.1.4.1.21239.5.2.5.1.4 | Gauge32 | read-only | Device availability: 0 = Unavailable 1 = Available 2 = Partially Unavailable |
| I32 airFlowSensorTemp | 1.3.6.1.4.1.21239.5.2.5.1.5 | Integer32 | read-only | Temperature reading in tenths of a degree. Units are given by temperatureUnits field in deviceInfo. |
| I32 airFlowSensorFlow | 1.3.6.1.4.1.21239.5.2.5.1.6 | Integer32 | read-only | Airflow reading. Still air will be less than 20, while rushing air will be around 100. |
| I32 airFlowSensorHumidity | 1.3.6.1.4.1.21239.5.2.5.1.7 | Integer32 | read-only | Humidity reading |
| I32 airFlowSensorDewPoint | 1.3.6.1.4.1.21239.5.2.5.1.8 | Integer32 | read-only | Dewpoint reading in tenths of a degree. Units are given by temperatureUnits field in deviceInfo. |
| t3hdSensorTable | 1.3.6.1.4.1.21239.5.2.8 | not-accessible | Remote Temperature x 3, Humidity and Dewpoint Sensor | |
| t3hdSensorEntry | 1.3.6.1.4.1.21239.5.2.8.1 | not-accessible | Entry in the t3hdSensorTable table: each entry contains an index and other sensor details | |
| I32 t3hdSensorIndex | 1.3.6.1.4.1.21239.5.2.8.1.1 | Integer32 | not-accessible | Table entry index value |
| STR t3hdSensorSerial | 1.3.6.1.4.1.21239.5.2.8.1.2 | DisplayString | read-only | Serial number |
| STR t3hdSensorLabel | 1.3.6.1.4.1.21239.5.2.8.1.3 | SnmpAdminString | read-write | User-defined label |
| G32 t3hdSensorAvail | 1.3.6.1.4.1.21239.5.2.8.1.4 | Gauge32 | read-only | Device availability: 0 = Unavailable 1 = Available 2 = Partially Unavailable |
| STR t3hdSensorIntLabel | 1.3.6.1.4.1.21239.5.2.8.1.5 | SnmpAdminString | read-write | Internal label (user-defined) |
| I32 t3hdSensorIntTemp | 1.3.6.1.4.1.21239.5.2.8.1.6 | Integer32 | read-only | Internal temperature in tenths of a degree. Units are given by temperatureUnits field in deviceInfo. |
| I32 t3hdSensorIntHumidity | 1.3.6.1.4.1.21239.5.2.8.1.7 | Integer32 | read-only | Internal humidity |
| I32 t3hdSensorIntDewPoint | 1.3.6.1.4.1.21239.5.2.8.1.8 | Integer32 | read-only | Internal dewpoint in tenths of a degree. Units are given by temperatureUnits field in deviceInfo. |
| G32 t3hdSensorExtAAvail | 1.3.6.1.4.1.21239.5.2.8.1.9 | Gauge32 | read-only | External A status: 0 = Unavailable 1 = Available |
| STR t3hdSensorExtALabel | 1.3.6.1.4.1.21239.5.2.8.1.10 | SnmpAdminString | read-write | External A label (user-defined) |
| I32 t3hdSensorExtATemp | 1.3.6.1.4.1.21239.5.2.8.1.11 | Integer32 | read-only | External A temperature in tenths of a degree. Units are given by temperatureUnits field in deviceInfo. |
| G32 t3hdSensorExtBAvail | 1.3.6.1.4.1.21239.5.2.8.1.12 | Gauge32 | read-only | External B status: 0 = Unavailable 1 = Available |
| STR t3hdSensorExtBLabel | 1.3.6.1.4.1.21239.5.2.8.1.13 | SnmpAdminString | read-write | External B label (user-defined) |
| I32 t3hdSensorExtBTemp | 1.3.6.1.4.1.21239.5.2.8.1.14 | Integer32 | read-only | External B temperature in tenths of a degree. Units are given by temperatureUnits field in deviceInfo. |
| thdSensorTable | 1.3.6.1.4.1.21239.5.2.9 | not-accessible | Remote Temperature, Humidity, and Dewpoint (THD) Sensor | |
| thdSensorEntry | 1.3.6.1.4.1.21239.5.2.9.1 | not-accessible | Entry in the thdSensorTable table: each entry contains an index and other sensor details | |
| I32 thdSensorIndex | 1.3.6.1.4.1.21239.5.2.9.1.1 | Integer32 | not-accessible | Table entry index value |
| STR thdSensorSerial | 1.3.6.1.4.1.21239.5.2.9.1.2 | DisplayString | read-only | Serial number |
| STR thdSensorLabel | 1.3.6.1.4.1.21239.5.2.9.1.3 | SnmpAdminString | read-write | User-defined label |
| G32 thdSensorAvail | 1.3.6.1.4.1.21239.5.2.9.1.4 | Gauge32 | read-only | Device availability: 0 = Unavailable 1 = Available 2 = Partially Unavailable |
| I32 thdSensorTemp | 1.3.6.1.4.1.21239.5.2.9.1.5 | Integer32 | read-only | Temperature value in tenths of a degree. Units are given by temperatureUnits field in deviceInfo. |
| I32 thdSensorHumidity | 1.3.6.1.4.1.21239.5.2.9.1.6 | Integer32 | read-only | Humidity value |
| I32 thdSensorDewPoint | 1.3.6.1.4.1.21239.5.2.9.1.7 | Integer32 | read-only | Dewpoint value in tenths of a degree. Units are given by temperatureUnits field in deviceInfo. |
| a2dSensorTable | 1.3.6.1.4.1.21239.5.2.11 | not-accessible | Analog measurement (A2D) sensor (voltage, current, or dry-contact) | |
| a2dSensorEntry | 1.3.6.1.4.1.21239.5.2.11.1 | not-accessible | Entry in the a2dSensorTable table: each entry contains an index and other sensor details | |
| I32 a2dSensorIndex | 1.3.6.1.4.1.21239.5.2.11.1.1 | Integer32 | not-accessible | Table entry index value |
| STR a2dSensorSerial | 1.3.6.1.4.1.21239.5.2.11.1.2 | DisplayString | read-only | Serial number |
| STR a2dSensorLabel | 1.3.6.1.4.1.21239.5.2.11.1.3 | SnmpAdminString | read-write | User-defined label |
| G32 a2dSensorAvail | 1.3.6.1.4.1.21239.5.2.11.1.4 | Gauge32 | read-only | Device availability: 0 = Unavailable 1 = Available 2 = Partially Unavailable |
| I32 a2dSensorValue | 1.3.6.1.4.1.21239.5.2.11.1.5 | Integer32 | read-only | Analog measurement value, within either a user-defined or preset range, depending on a2dSensorMode. |
| STR a2dSensorDisplayValue | 1.3.6.1.4.1.21239.5.2.11.1.6 | SnmpAdminString | read-only | For current/voltage modes, the analog value is given as a string. In binary modes, the value is either a2dSensorLowLabel or a2dSensorHighLabel, based on a2dSensorValue. |
| INT a2dSensorMode | 1.3.6.1.4.1.21239.5.2.11.1.7 | INTEGER | read-write | Binary modes have two states represented by the values 0 (low) or 1 (high). These correspond to a2dSensorLowLabel and a2dSensorHighLabel. Current and voltage modes provide a scaled value from a2dSensorMin to a2dSensorMax. Analog modes: 1 = Door (binary) 2 = Power failure (binary) 3 = Flood (binary) 4 = Water-sensing cable leak (binary) 5 = Water-sensing cable fault (binary) 6 = Smoke alarm (binary) 7 = Isolated voltage negative ground (voltage) 8 = Isolated voltage positive ground (voltage) 9 = Custom voltage (voltage) 10 = Custom binary (binary) 11 = Custom current (current) |
| STR a2dSensorUnits | 1.3.6.1.4.1.21239.5.2.11.1.8 | SnmpAdminString | read-write | The units for the analog value. If a2dSensorMode is customVoltage(9) or customCurrent(11), then this field has a user-defined value. Otherwise, the value is fixed, based on mode. |
| I32 a2dSensorMin | 1.3.6.1.4.1.21239.5.2.11.1.9 | Integer32 | read-write | Minimum analog value, given as an integer. The analog measurement is scaled to the range a2dSensorMin to a2dSensorMax. If a2dSensorMode is customVoltage(9) or customCurrent(11), then this field has a user- defined value. Otherwise, the value is fixed, based on mode. |
| I32 a2dSensorMax | 1.3.6.1.4.1.21239.5.2.11.1.10 | Integer32 | read-write | Maximum analog value, given as an integer. The analog measurement is scaled to the range a2dSensorMin to a2dSensorMax. If a2dSensorMode is customVoltage(9) or customCurrent(11), then this field has a user- defined value. Otherwise, the value is fixed, based on mode. |
| STR a2dSensorLowLabel | 1.3.6.1.4.1.21239.5.2.11.1.11 | SnmpAdminString | read-write | Label for 0 (low) binary value. This field is only applicable if a2dSensorMode is one of the binary modes. If a2dSensorMode is customBinary(10), then this field is user-defined. Otherwise, it has a pre-defined value based on the mode. |
| STR a2dSensorHighLabel | 1.3.6.1.4.1.21239.5.2.11.1.12 | SnmpAdminString | read-write | Label for 1 (high) binary value. The field is only applicable if a2dSensorMode is one of the binary modes. If a2dSensorMode is customBinary(10), then this field is user-defined. Otherwise, it has a pre-defined value based on the mode. |
| STR a2dSensorAnalogLabel | 1.3.6.1.4.1.21239.5.2.11.1.13 | SnmpAdminString | read-write | Label for the analog measurement |
| humiditySensorTable | 1.3.6.1.4.1.21239.5.2.12 | not-accessible | Remote humidity sensor | |
| humiditySensorEntry | 1.3.6.1.4.1.21239.5.2.12.1 | not-accessible | Entry in the humiditySensorTable table: each entry contains an index and other sensor details | |
| I32 humiditySensorIndex | 1.3.6.1.4.1.21239.5.2.12.1.1 | Integer32 | not-accessible | Table entry index value |
| STR humiditySensorSerial | 1.3.6.1.4.1.21239.5.2.12.1.2 | DisplayString | read-only | Serial number |
| STR humiditySensorLabel | 1.3.6.1.4.1.21239.5.2.12.1.3 | SnmpAdminString | read-write | User-defined label |
| G32 humiditySensorAvail | 1.3.6.1.4.1.21239.5.2.12.1.4 | Gauge32 | read-only | Device availability: 0 = Unavailable 1 = Available 2 = Partially Unavailable |
| I32 humiditySensorValue | 1.3.6.1.4.1.21239.5.2.12.1.5 | Integer32 | read-only | Humidity value |
| sn2dSensorTable | 1.3.6.1.4.1.21239.5.2.13 | not-accessible | 2 Door Switch Sensor (SN-2D) | |
| sn2dSensorEntry | 1.3.6.1.4.1.21239.5.2.13.1 | not-accessible | Entry in the sn2dSensorTable table: each entry contains an index and other sensor details | |
| I32 sn2dSensorIndex | 1.3.6.1.4.1.21239.5.2.13.1.1 | Integer32 | not-accessible | Table entry index value |
| STR sn2dSensorSerial | 1.3.6.1.4.1.21239.5.2.13.1.2 | DisplayString | read-only | Serial number |
| STR sn2dSensorLabel | 1.3.6.1.4.1.21239.5.2.13.1.3 | SnmpAdminString | read-write | User-defined label |
| G32 sn2dSensorAvail | 1.3.6.1.4.1.21239.5.2.13.1.4 | Gauge32 | read-only | Device availability: 0 = Unavailable 1 = Available 2 = Partially Unavailable |
| STR sn2dSensorDoor1Label | 1.3.6.1.4.1.21239.5.2.13.1.5 | SnmpAdminString | read-write | Door switch 1 label |
| INT sn2dSensorDoor1State | 1.3.6.1.4.1.21239.5.2.13.1.6 | INTEGER | read-only | Door switch 1 state: 1 = open 2 = closed |
| STR sn2dSensorDoor1DisplayState | 1.3.6.1.4.1.21239.5.2.13.1.7 | SnmpAdminString | read-only | Door switch 1 state given as a string |
| STR sn2dSensorDoor2Label | 1.3.6.1.4.1.21239.5.2.13.1.8 | SnmpAdminString | read-write | Door switch 2 label |
| INT sn2dSensorDoor2State | 1.3.6.1.4.1.21239.5.2.13.1.9 | INTEGER | read-only | Door switch 2 state: 1 = open 2 = closed |
| STR sn2dSensorDoor2DisplayState | 1.3.6.1.4.1.21239.5.2.13.1.10 | SnmpAdminString | read-only | Door switch 2 state given as a string |
| cooling | 1.3.6.1.4.1.21239.5.2.30 | |||
| vrc | 1.3.6.1.4.1.21239.5.2.30.1 | |||
| vrcMainTable | 1.3.6.1.4.1.21239.5.2.30.1.1 | not-accessible | Table that contains general VRC information | |
| vrcMainEntry | 1.3.6.1.4.1.21239.5.2.30.1.1.1 | not-accessible | Entry in the vrcMainTable: each entry represents a VRC device | |
| I32 vrcMainIndex | 1.3.6.1.4.1.21239.5.2.30.1.1.1.1 | Integer32 | not-accessible | Unique id for each entry in the table |
| STR vrcMainSerial | 1.3.6.1.4.1.21239.5.2.30.1.1.1.2 | DisplayString | read-only | Serial number |
| STR vrcMainName | 1.3.6.1.4.1.21239.5.2.30.1.1.1.3 | SnmpAdminString | read-only | VRC name (factory-assigned) |
| STR vrcMainLabel | 1.3.6.1.4.1.21239.5.2.30.1.1.1.4 | SnmpAdminString | read-write | VRC label (user-defined) |
| G32 vrcMainAvail | 1.3.6.1.4.1.21239.5.2.30.1.1.1.5 | Gauge32 | read-only | Device availability: 0 = Unavailable 1 = Available 2 = Partially Unavailable |
| vrcMainPtTable | 1.3.6.1.4.1.21239.5.2.30.1.2 | not-accessible | Table that contains general VRC status | |
| vrcMainPtEntry | 1.3.6.1.4.1.21239.5.2.30.1.2.1 | not-accessible | Entry in the vrcMainPtTable: each entry contains status data for a VRC device | |
| I32 vrcMainPtIndex | 1.3.6.1.4.1.21239.5.2.30.1.2.1.1 | Integer32 | not-accessible | Unique id for each entry in the table |
| INT vrcMainPtRunState | 1.3.6.1.4.1.21239.5.2.30.1.2.1.2 | INTEGER | read-only | VRC run state: 1 = on 2 = off |
| I32 vrcMainPtEevOpened | 1.3.6.1.4.1.21239.5.2.30.1.2.1.3 | Integer32 | read-only | Eev opened value (percent) |
| I32 vrcMainPtAlarmNumbers | 1.3.6.1.4.1.21239.5.2.30.1.2.1.4 | Integer32 | read-only | Alarm numbers value |
| I32 vrcMainPtHistoryAlarmNumbers | 1.3.6.1.4.1.21239.5.2.30.1.2.1.5 | Integer32 | read-only | History alarm numbers value |
| I32 vrcMainPtHpAbnRecordCnt | 1.3.6.1.4.1.21239.5.2.30.1.2.1.6 | Integer32 | read-only | Hp Abnormal record count |
| INT vrcMainPtMonitorBaudrate | 1.3.6.1.4.1.21239.5.2.30.1.2.1.7 | INTEGER | read-only | Monitor baud rate: 1 = error 2 = 1200 3 = 2400 4 = 4800 5 = 9600 6 = 19200 |
| I32 vrcMainPtMonitorAddress | 1.3.6.1.4.1.21239.5.2.30.1.2.1.8 | Integer32 | read-only | Monitor address |
| T/F vrcMainPtLp | 1.3.6.1.4.1.21239.5.2.30.1.2.1.9 | TruthValue | read-only | Lp status |
| T/F vrcMainPtFilterMaintRemind | 1.3.6.1.4.1.21239.5.2.30.1.2.1.10 | TruthValue | read-only | Filter maintenance reminder status |
| T/F vrcMainPtCoolingFlag | 1.3.6.1.4.1.21239.5.2.30.1.2.1.11 | TruthValue | read-only | Cooling flag |
| T/F vrcMainPtFirstOnFlag | 1.3.6.1.4.1.21239.5.2.30.1.2.1.12 | TruthValue | read-only | First on flag |
| T/F vrcMainPtNewAlarmFlag | 1.3.6.1.4.1.21239.5.2.30.1.2.1.13 | TruthValue | read-only | New alarm flag |
| T/F vrcMainPtComAlarmOutState | 1.3.6.1.4.1.21239.5.2.30.1.2.1.14 | TruthValue | read-only | Common alarm output state |
| T/F vrcMainPtHighWaterInput | 1.3.6.1.4.1.21239.5.2.30.1.2.1.15 | TruthValue | read-only | High water input |
| T/F vrcMainPtHighWaterAlarm | 1.3.6.1.4.1.21239.5.2.30.1.2.1.16 | TruthValue | read-only | High water alarm status |
| T/F vrcMainPtWaterUnderFloorAlarm | 1.3.6.1.4.1.21239.5.2.30.1.2.1.17 | TruthValue | read-only | Water under floor alarm status |
| T/F vrcMainPtSwShutDownStatus | 1.3.6.1.4.1.21239.5.2.30.1.2.1.18 | TruthValue | read-only | Software shutdown status |
| T/F vrcMainPtRemoteShutdown | 1.3.6.1.4.1.21239.5.2.30.1.2.1.19 | TruthValue | read-only | Remote shutdown status |
| T/F vrcMainPtRemoteShutDownFlag | 1.3.6.1.4.1.21239.5.2.30.1.2.1.20 | TruthValue | read-only | Remote shutdown flag |
| T/F vrcMainPtRemoteShutDownAlarm | 1.3.6.1.4.1.21239.5.2.30.1.2.1.21 | TruthValue | read-only | Remote shutdown alarm status |
| T/F vrcMainPtHmiShutDownFlag | 1.3.6.1.4.1.21239.5.2.30.1.2.1.22 | TruthValue | read-only | Hmi shutdown flag |
| T/F vrcMainPtLpAlarm | 1.3.6.1.4.1.21239.5.2.30.1.2.1.23 | TruthValue | read-only | Low pressure alarm status |
| T/F vrcMainPtHpAlarm | 1.3.6.1.4.1.21239.5.2.30.1.2.1.24 | TruthValue | read-only | High pressure alarm status |
| T/F vrcMainPtLpFreqAlarm | 1.3.6.1.4.1.21239.5.2.30.1.2.1.25 | TruthValue | read-only | Low pressure frequently alarm status |
| T/F vrcMainPtHpFreqAlarm | 1.3.6.1.4.1.21239.5.2.30.1.2.1.26 | TruthValue | read-only | High pressure frequently alarm status |
| T/F vrcMainPtLpSensorFailAlarm | 1.3.6.1.4.1.21239.5.2.30.1.2.1.27 | TruthValue | read-only | Low pressure sensor failure alarm status |
| T/F vrcMainPtHpSensorFailAlarm | 1.3.6.1.4.1.21239.5.2.30.1.2.1.28 | TruthValue | read-only | High pressure sensor failure alarm status |
| T/F vrcMainPtEevCommFailAlarm | 1.3.6.1.4.1.21239.5.2.30.1.2.1.29 | TruthValue | read-only | Eev communication failure alarm status |
| vrcMainCfgTable | 1.3.6.1.4.1.21239.5.2.30.1.3 | not-accessible | Table that contains general VRC configuration | |
| vrcMainCfgEntry | 1.3.6.1.4.1.21239.5.2.30.1.3.1 | not-accessible | Entry in the vrcMainCfgTable: each entry contains general config fields for a VRC device | |
| I32 vrcMainCfgIndex | 1.3.6.1.4.1.21239.5.2.30.1.3.1.1 | Integer32 | not-accessible | Unique id for each entry in the table |
| INT vrcMainCfgModelSelect | 1.3.6.1.4.1.21239.5.2.30.1.3.1.2 | INTEGER | read-write | Model Selection: 1 = TMM-Local 220V 50/60HZ 2 = TMM-Global 208/230V 50/60HZ 3 = TMM-Global 120V 50/60HZ 4 = SC 220V 50/60HZ 5 = 0U 220V 50/60HZ 6 = SS 208/230V 50/60HZ 7 = SS 120V 50/60HZ |
| I32 vrcMainCfgSystemTimeYear | 1.3.6.1.4.1.21239.5.2.30.1.3.1.3 | Integer32 | read-write | System time - year |
| I32 vrcMainCfgSystemTimeMonth | 1.3.6.1.4.1.21239.5.2.30.1.3.1.4 | Integer32 | read-write | System time - month |
| I32 vrcMainCfgSystemTimeDay | 1.3.6.1.4.1.21239.5.2.30.1.3.1.5 | Integer32 | read-write | System time - day |
| I32 vrcMainCfgSystemTimeHour | 1.3.6.1.4.1.21239.5.2.30.1.3.1.6 | Integer32 | read-write | System time - hour |
| I32 vrcMainCfgSystemTimeMin | 1.3.6.1.4.1.21239.5.2.30.1.3.1.7 | Integer32 | read-write | System time - minutes |
| I32 vrcMainCfgSystemTimeSec | 1.3.6.1.4.1.21239.5.2.30.1.3.1.8 | Integer32 | read-write | System time - seconds |
| I32 vrcMainCfgEevShtSettingMin | 1.3.6.1.4.1.21239.5.2.30.1.3.1.9 | Integer32 | read-write | Min Eev sht in tenths of a degree. Units are given by temperatureUnits field in deviceInfo. The settable range is determined by the current temperature units. Celsius: 50 to 200 Fahrenheit: 90 to 359 |
| I32 vrcMainCfgEevShtSettingMax | 1.3.6.1.4.1.21239.5.2.30.1.3.1.10 | Integer32 | read-write | Max Eev sht in tenths of a degree. Units are given by temperatureUnits field in deviceInfo. The settable range is determined by the current temperature units. Celsius: 50 to 200 Fahrenheit: 90 to 359 |
| I32 vrcMainCfgEevValveCloseSht | 1.3.6.1.4.1.21239.5.2.30.1.3.1.11 | Integer32 | read-write | Eev valve close sht in tenths of a degree. Units are given by temperatureUnits field in deviceInfo. The settable range is determined by the current temperature units. Celsius: 0 to 100 Fahrenheit: 0 to 179 |
| I32 vrcMainCfgEevMopPressSetting | 1.3.6.1.4.1.21239.5.2.30.1.3.1.12 | Integer32 | read-write | Eev mop pressure setting in tenths of a bar. |
| I32 vrcMainCfgLpdt | 1.3.6.1.4.1.21239.5.2.30.1.3.1.13 | Integer32 | read-write | Low pressure dt in seconds |
| I32 vrcMainCfgDeadBand | 1.3.6.1.4.1.21239.5.2.30.1.3.1.14 | Integer32 | read-write | Dead band in tenths of a degree. Units are given by temperatureUnits field in deviceInfo. The settable range is determined by the current temperature units. Celsius: 0 to 20 Fahrenheit: 0 to 35 |
| T/F vrcMainCfgOnOffSwitch | 1.3.6.1.4.1.21239.5.2.30.1.3.1.15 | TruthValue | read-write | On-off switch |
| T/F vrcMainCfgVacuumState | 1.3.6.1.4.1.21239.5.2.30.1.3.1.16 | TruthValue | read-write | Vacuum state |
| INT vrcMainCfgControlMode | 1.3.6.1.4.1.21239.5.2.30.1.3.1.17 | INTEGER | read-write | Control mode: 1 = supply 2 = return |
| T/F vrcMainCfgManualRunEnable | 1.3.6.1.4.1.21239.5.2.30.1.3.1.18 | TruthValue | read-write | Manual run enable |
| T/F vrcMainCfgRemShutdownInput | 1.3.6.1.4.1.21239.5.2.30.1.3.1.19 | TruthValue | read-write | Remote shutdown input |
| T/F vrcMainCfgMonitorShutDownFlag | 1.3.6.1.4.1.21239.5.2.30.1.3.1.20 | TruthValue | read-write | Monitor shutdown flag |
| I32 vrcMainCfgFirstOnPassword | 1.3.6.1.4.1.21239.5.2.30.1.3.1.21 | Integer32 | read-write | First on password value |
| T/F vrcMainCfgFilterMaintSetting | 1.3.6.1.4.1.21239.5.2.30.1.3.1.22 | TruthValue | read-write | Filter maintenance setting |
| I32 vrcMainCfgFilterMaintRemindTime | 1.3.6.1.4.1.21239.5.2.30.1.3.1.23 | Integer32 | read-write | Time between filter maintenance reminders in days |
| INT vrcMainCfgFilterMaintRemindCtrl | 1.3.6.1.4.1.21239.5.2.30.1.3.1.24 | INTEGER | read-write | Filter maintenance reminder: 1 = close 2 = suspend 3 = open |
| T/F vrcMainCfgCommonAlarmOutputDir | 1.3.6.1.4.1.21239.5.2.30.1.3.1.25 | TruthValue | read-write | Common alarm output direction |
| I32 vrcMainCfgHpAbnAlarmSetting | 1.3.6.1.4.1.21239.5.2.30.1.3.1.26 | Integer32 | read-write | Abnormal high pressure alarm value in tenths of a bar |
| INT vrcMainCfgLpAlarmCtrl | 1.3.6.1.4.1.21239.5.2.30.1.3.1.27 | INTEGER | read-write | Low pressure alarm control: 2 = suspend 3 = open |
| INT vrcMainCfgHpAlarmCtrl | 1.3.6.1.4.1.21239.5.2.30.1.3.1.28 | INTEGER | read-write | High pressure alarm control: 2 = suspend 3 = open |
| INT vrcMainCfgLpFreqAlarmCtrl | 1.3.6.1.4.1.21239.5.2.30.1.3.1.29 | INTEGER | read-write | Low pressure frequently alarm control: 2 = suspend 3 = open |
| INT vrcMainCfgHpFreqAlarmCtrl | 1.3.6.1.4.1.21239.5.2.30.1.3.1.30 | INTEGER | read-write | High pressure frequently alarm control: 2 = suspend 3 = open |
| INT vrcMainCfgLpSensorFailAlarmCtrl | 1.3.6.1.4.1.21239.5.2.30.1.3.1.31 | INTEGER | read-write | Low pressure sensor failure alarm control: 2 = suspend 3 = open |
| INT vrcMainCfgHpSensorFailAlarmCtrl | 1.3.6.1.4.1.21239.5.2.30.1.3.1.32 | INTEGER | read-write | High pressure sensor failure alarm control: 2 = suspend 3 = open |
| INT vrcMainCfgHighWaterAlarmCtrl | 1.3.6.1.4.1.21239.5.2.30.1.3.1.33 | INTEGER | read-write | High water alarm control: 1 = close 2 = suspend 3 = open |
| INT vrcMainCfgRemShutdownAlarmCtrl | 1.3.6.1.4.1.21239.5.2.30.1.3.1.34 | INTEGER | read-write | Remote shutdown alarm control: 2 = suspend 3 = open |
| INT vrcMainCfgEevCommFailAlarmCtrl | 1.3.6.1.4.1.21239.5.2.30.1.3.1.35 | INTEGER | read-write | Eev communication failure alarm: 2 = suspend 3 = open |
| vrcOutFanPtTable | 1.3.6.1.4.1.21239.5.2.30.1.4 | not-accessible | Table that contains VRC out-fan status | |
| vrcOutFanPtEntry | 1.3.6.1.4.1.21239.5.2.30.1.4.1 | not-accessible | Entry in the vrcOutFanPtTable: each entry represents data for a VRC out-fan | |
| I32 vrcOutFanPtIndex | 1.3.6.1.4.1.21239.5.2.30.1.4.1.1 | Integer32 | not-accessible | Unique id for each entry in the table |
| STR vrcOutFanPtName | 1.3.6.1.4.1.21239.5.2.30.1.4.1.2 | SnmpAdminString | read-only | Out-fan name (factory-assigned) |
| I32 vrcOutFanPtSpeed | 1.3.6.1.4.1.21239.5.2.30.1.4.1.3 | Integer32 | read-only | Fan speed (percent) |
| vrcOutFanCfgTable | 1.3.6.1.4.1.21239.5.2.30.1.5 | not-accessible | Table used for VRC out-fan configuration | |
| vrcOutFanCfgEntry | 1.3.6.1.4.1.21239.5.2.30.1.5.1 | not-accessible | Entry in the vrcOutFanCfgTable: each entry contains config fields for a VRC out-fan | |
| I32 vrcOutFanCfgIndex | 1.3.6.1.4.1.21239.5.2.30.1.5.1.1 | Integer32 | not-accessible | Unique id for each entry in the table |
| I32 vrcOutFanCfgStartPress | 1.3.6.1.4.1.21239.5.2.30.1.5.1.2 | Integer32 | read-write | Out-fan start pressure in tenths of a bar |
| I32 vrcOutFanCfgPressSetting | 1.3.6.1.4.1.21239.5.2.30.1.5.1.3 | Integer32 | read-write | Out-fan pressure setting in tenths of a bar |
| I32 vrcOutFanCfgMinPowerVoltage | 1.3.6.1.4.1.21239.5.2.30.1.5.1.4 | Integer32 | read-write | Min out-fan voltage (percent) |
| I32 vrcOutFanCfgMaxPowerVoltage | 1.3.6.1.4.1.21239.5.2.30.1.5.1.5 | Integer32 | read-write | Max out-fan voltage (percent) |
| I32 vrcOutFanCfgSpeed | 1.3.6.1.4.1.21239.5.2.30.1.5.1.6 | Integer32 | read-write | Out-fan speed (percent) |
| vrcInFanPtTable | 1.3.6.1.4.1.21239.5.2.30.1.6 | not-accessible | Table that contains VRC in-fan status | |
| vrcInFanPtEntry | 1.3.6.1.4.1.21239.5.2.30.1.6.1 | not-accessible | Entry in the vrcInFanPtTable: each entry represents data for a VRC in- fan | |
| I32 vrcInFanPtIndex | 1.3.6.1.4.1.21239.5.2.30.1.6.1.1 | Integer32 | not-accessible | Unique id for each entry in the table |
| STR vrcInFanPtName | 1.3.6.1.4.1.21239.5.2.30.1.6.1.2 | SnmpAdminString | read-only | In-fan name (factory-assigned) |
| I32 vrcInFanPtRunTimeHours | 1.3.6.1.4.1.21239.5.2.30.1.6.1.3 | Integer32 | read-only | In-fan run time in hours |
| I32 vrcInFanPtStartStopCount | 1.3.6.1.4.1.21239.5.2.30.1.6.1.4 | Integer32 | read-only | In-fan start/stop count |
| vrcInFanCfgTable | 1.3.6.1.4.1.21239.5.2.30.1.7 | not-accessible | Table used for VRC in-fan configuration | |
| vrcInFanCfgEntry | 1.3.6.1.4.1.21239.5.2.30.1.7.1 | not-accessible | Entry in the vrcInFanCfgTable: each entry contains config fields for a VRC in-fan | |
| I32 vrcInFanCfgIndex | 1.3.6.1.4.1.21239.5.2.30.1.7.1.1 | Integer32 | not-accessible | Unique id for each entry in the table |
| T/F vrcInFanCfgOutputStatus | 1.3.6.1.4.1.21239.5.2.30.1.7.1.2 | TruthValue | read-write | In-fan output status |
| I32 vrcInFanCfgLowSpeedStep | 1.3.6.1.4.1.21239.5.2.30.1.7.1.3 | Integer32 | read-write | In-fan low speed step in tenths of a percent per second |
| I32 vrcInFanCfgHighSpeedStep | 1.3.6.1.4.1.21239.5.2.30.1.7.1.4 | Integer32 | read-write | In-fan high speed step in tenths of a percent per second |
| I32 vrcInFanCfgMinSpeed | 1.3.6.1.4.1.21239.5.2.30.1.7.1.5 | Integer32 | read-write | Min in-fan speed (percent) |
| I32 vrcInFanCfgStandardSpeed | 1.3.6.1.4.1.21239.5.2.30.1.7.1.6 | Integer32 | read-write | Standard in-fan speed (percent) |
| I32 vrcInFanCfgMinCfc | 1.3.6.1.4.1.21239.5.2.30.1.7.1.7 | Integer32 | read-write | Min in-fan cfc (percent) |
| I32 vrcInFanCfgStandardCfc | 1.3.6.1.4.1.21239.5.2.30.1.7.1.8 | Integer32 | read-write | Standard in-fan cfc (percent) |
| I32 vrcInFanCfgStartDelay | 1.3.6.1.4.1.21239.5.2.30.1.7.1.9 | Integer32 | read-write | In-fan start delay in seconds |
| I32 vrcInFanCfgStopDelay | 1.3.6.1.4.1.21239.5.2.30.1.7.1.10 | Integer32 | read-write | In-fan stop delay in seconds |
| I32 vrcInFanCfgReduceSpeedDelay | 1.3.6.1.4.1.21239.5.2.30.1.7.1.11 | Integer32 | read-write | In-fan reduce speed delay in seconds |
| I32 vrcInFanCfgJumpBand1 | 1.3.6.1.4.1.21239.5.2.30.1.7.1.12 | Integer32 | read-write | In-fan jump band 1 in tenths of a percent |
| I32 vrcInFanCfgJumpBand2 | 1.3.6.1.4.1.21239.5.2.30.1.7.1.13 | Integer32 | read-write | In-fan jump band 2 in tenths of a percent |
| I32 vrcInFanCfgJumpBand3 | 1.3.6.1.4.1.21239.5.2.30.1.7.1.14 | Integer32 | read-write | In-fan jump band 3 in tenths of a percent |
| I32 vrcInFanCfgJumpBand4 | 1.3.6.1.4.1.21239.5.2.30.1.7.1.15 | Integer32 | read-write | In-fan jump band 4 in tenths of a percent |
| I32 vrcInFanCfgJumpBand5 | 1.3.6.1.4.1.21239.5.2.30.1.7.1.16 | Integer32 | read-write | In-fan jump band 5 in tenths of a percent |
| I32 vrcInFanCfgJumpFreq1 | 1.3.6.1.4.1.21239.5.2.30.1.7.1.17 | Integer32 | read-write | In-fan jump frequency 1 in tenths of a percent |
| I32 vrcInFanCfgJumpFreq2 | 1.3.6.1.4.1.21239.5.2.30.1.7.1.18 | Integer32 | read-write | In-fan jump frequency 2 in tenths of a percent |
| I32 vrcInFanCfgJumpFreq3 | 1.3.6.1.4.1.21239.5.2.30.1.7.1.19 | Integer32 | read-write | In-fan jump frequency 3 in tenths of a percent |
| I32 vrcInFanCfgJumpFreq4 | 1.3.6.1.4.1.21239.5.2.30.1.7.1.20 | Integer32 | read-write | In-fan jump frequency 4 in tenths of a percent |
| I32 vrcInFanCfgJumpFreq5 | 1.3.6.1.4.1.21239.5.2.30.1.7.1.21 | Integer32 | read-write | In-fan jump frequency 5 in tenths of a percent |
| I32 vrcInFanCfgTempP | 1.3.6.1.4.1.21239.5.2.30.1.7.1.22 | Integer32 | read-write | In-fan temperature P in tenths of a degree. Units are given by temperatureUnits field in deviceInfo. |
| I32 vrcInFanCfgTempI | 1.3.6.1.4.1.21239.5.2.30.1.7.1.23 | Integer32 | read-write | In-fan temperature I in seconds |
| I32 vrcInFanCfgTempD | 1.3.6.1.4.1.21239.5.2.30.1.7.1.24 | Integer32 | read-write | In-fan temperature D in seconds |
| vrcCompPtTable | 1.3.6.1.4.1.21239.5.2.30.1.8 | not-accessible | Table that contains VRC compressor status | |
| vrcCompPtEntry | 1.3.6.1.4.1.21239.5.2.30.1.8.1 | not-accessible | Entry in the vrcCompPtTable: each entry represents data for a VRC compressor | |
| I32 vrcCompPtIndex | 1.3.6.1.4.1.21239.5.2.30.1.8.1.1 | Integer32 | not-accessible | Unique id for each entry in the table |
| STR vrcCompPtName | 1.3.6.1.4.1.21239.5.2.30.1.8.1.2 | SnmpAdminString | read-only | Compressor name (factory-assigned) |
| I32 vrcCompPtCapacity | 1.3.6.1.4.1.21239.5.2.30.1.8.1.3 | Integer32 | read-only | Compressor capacity value (percent) |
| I32 vrcCompPtRunTimeHours | 1.3.6.1.4.1.21239.5.2.30.1.8.1.4 | Integer32 | read-only | Compressor run time in hours |
| I32 vrcCompPtStartStopCount | 1.3.6.1.4.1.21239.5.2.30.1.8.1.5 | Integer32 | read-only | Compressor start/stop count |
| T/F vrcCompPtDriverFaultU00 | 1.3.6.1.4.1.21239.5.2.30.1.8.1.6 | TruthValue | read-only | Compressor driver fault alarm U00 state |
| T/F vrcCompPtDriverFaultU01 | 1.3.6.1.4.1.21239.5.2.30.1.8.1.7 | TruthValue | read-only | Compressor driver fault alarm U01 state |
| T/F vrcCompPtDriverFaultU02 | 1.3.6.1.4.1.21239.5.2.30.1.8.1.8 | TruthValue | read-only | Compressor driver fault alarm U02 state |
| T/F vrcCompPtDriverFaultU03 | 1.3.6.1.4.1.21239.5.2.30.1.8.1.9 | TruthValue | read-only | Compressor driver fault alarm U03 state |
| T/F vrcCompPtDriverFaultU04 | 1.3.6.1.4.1.21239.5.2.30.1.8.1.10 | TruthValue | read-only | Compressor driver fault alarm U04 state |
| T/F vrcCompPtDriverFaultU05 | 1.3.6.1.4.1.21239.5.2.30.1.8.1.11 | TruthValue | read-only | Compressor driver fault alarm U05 state |
| T/F vrcCompPtDriverFaultU06 | 1.3.6.1.4.1.21239.5.2.30.1.8.1.12 | TruthValue | read-only | Compressor driver fault alarm U06 state |
| T/F vrcCompPtDriverFaultU07 | 1.3.6.1.4.1.21239.5.2.30.1.8.1.13 | TruthValue | read-only | Compressor driver fault alarm U07 state |
| T/F vrcCompPtDriverFaultU08 | 1.3.6.1.4.1.21239.5.2.30.1.8.1.14 | TruthValue | read-only | Compressor driver fault alarm U08 state |
| T/F vrcCompPtDriverFaultU09 | 1.3.6.1.4.1.21239.5.2.30.1.8.1.15 | TruthValue | read-only | Compressor driver fault alarm U09 state |
| T/F vrcCompPtDriverFaultU10 | 1.3.6.1.4.1.21239.5.2.30.1.8.1.16 | TruthValue | read-only | Compressor driver fault alarm U10 state |
| T/F vrcCompPtDriverFaultU11 | 1.3.6.1.4.1.21239.5.2.30.1.8.1.17 | TruthValue | read-only | Compressor driver fault alarm U11 state |
| T/F vrcCompPtDriverFaultU12 | 1.3.6.1.4.1.21239.5.2.30.1.8.1.18 | TruthValue | read-only | Compressor driver fault alarm U12 state |
| T/F vrcCompPtDriverFaultU13 | 1.3.6.1.4.1.21239.5.2.30.1.8.1.19 | TruthValue | read-only | Compressor driver fault alarm U13 state |
| T/F vrcCompPtDriverFaultU14 | 1.3.6.1.4.1.21239.5.2.30.1.8.1.20 | TruthValue | read-only | Compressor driver fault alarm U14 state |
| T/F vrcCompPtDriverFaultU15 | 1.3.6.1.4.1.21239.5.2.30.1.8.1.21 | TruthValue | read-only | Compressor driver fault alarm U15 state |
| T/F vrcCompPtDriverCommFailAlarm | 1.3.6.1.4.1.21239.5.2.30.1.8.1.22 | TruthValue | read-only | Compressor driver communication failure alarm state |
| T/F vrcCompPtFaultLockAlarm | 1.3.6.1.4.1.21239.5.2.30.1.8.1.23 | TruthValue | read-only | Compressor fault lock alarm state |
| vrcCompCfgTable | 1.3.6.1.4.1.21239.5.2.30.1.9 | not-accessible | Table used for VRC compressor configuration | |
| vrcCompCfgEntry | 1.3.6.1.4.1.21239.5.2.30.1.9.1 | not-accessible | Entry in the vrcCompCfgTable: each entry contains config fields for a VRC compressor | |
| I32 vrcCompCfgIndex | 1.3.6.1.4.1.21239.5.2.30.1.9.1.1 | Integer32 | not-accessible | Unique id for each entry in the table |
| T/F vrcCompCfgOutputStatus | 1.3.6.1.4.1.21239.5.2.30.1.9.1.2 | TruthValue | read-write | Compressor output status |
| I32 vrcCompCfgOutputDeadBand | 1.3.6.1.4.1.21239.5.2.30.1.9.1.3 | Integer32 | read-write | Compressor output dead band in tenths of a percent |
| I32 vrcCompCfgCapacityOutputValue | 1.3.6.1.4.1.21239.5.2.30.1.9.1.4 | Integer32 | read-write | Compressor capacity output (percent) |
| I32 vrcCompCfgMinCapacity | 1.3.6.1.4.1.21239.5.2.30.1.9.1.5 | Integer32 | read-write | Compressor min capacity (percent) |
| I32 vrcCompCfgStartCapacity | 1.3.6.1.4.1.21239.5.2.30.1.9.1.6 | Integer32 | read-write | Compressor start capacity (percent) |
| I32 vrcCompCfgStandardCapacity | 1.3.6.1.4.1.21239.5.2.30.1.9.1.7 | Integer32 | read-write | Compressor standard capacity (percent) |
| I32 vrcCompCfgStartCfc | 1.3.6.1.4.1.21239.5.2.30.1.9.1.8 | Integer32 | read-write | Compressor start cfc (percent) |
| I32 vrcCompCfgStopCfc | 1.3.6.1.4.1.21239.5.2.30.1.9.1.9 | Integer32 | read-write | Compressor stop cfc (percent) |
| I32 vrcCompCfgMinRunTime | 1.3.6.1.4.1.21239.5.2.30.1.9.1.10 | Integer32 | read-write | Compressor min run time in minutes |
| I32 vrcCompCfgMinStopTime | 1.3.6.1.4.1.21239.5.2.30.1.9.1.11 | Integer32 | read-write | Compressor min stop time in minutes |
| I32 vrcCompCfgJumpBand1 | 1.3.6.1.4.1.21239.5.2.30.1.9.1.12 | Integer32 | read-write | Compressor jump band 1 in tenths of a percent |
| I32 vrcCompCfgJumpBand2 | 1.3.6.1.4.1.21239.5.2.30.1.9.1.13 | Integer32 | read-write | Compressor jump band 2 in tenths of a percent |
| I32 vrcCompCfgJumpBand3 | 1.3.6.1.4.1.21239.5.2.30.1.9.1.14 | Integer32 | read-write | Compressor jump band 3 in tenths of a percent |
| I32 vrcCompCfgJumpBand4 | 1.3.6.1.4.1.21239.5.2.30.1.9.1.15 | Integer32 | read-write | Compressor jump band 4 in tenths of a percent |
| I32 vrcCompCfgJumpBand5 | 1.3.6.1.4.1.21239.5.2.30.1.9.1.16 | Integer32 | read-write | Compressor jump band 5 in tenths of a percent |
| I32 vrcCompCfgJumpFreq1 | 1.3.6.1.4.1.21239.5.2.30.1.9.1.17 | Integer32 | read-write | Compressor jump frequency 1 in tenths of a percent |
| I32 vrcCompCfgJumpFreq2 | 1.3.6.1.4.1.21239.5.2.30.1.9.1.18 | Integer32 | read-write | Compressor jump frequency 2 in tenths of a percent |
| I32 vrcCompCfgJumpFreq3 | 1.3.6.1.4.1.21239.5.2.30.1.9.1.19 | Integer32 | read-write | Compressor jump frequency 3 in tenths of a percent |
| I32 vrcCompCfgJumpFreq4 | 1.3.6.1.4.1.21239.5.2.30.1.9.1.20 | Integer32 | read-write | Compressor jump frequency 4 in tenths of a percent |
| I32 vrcCompCfgJumpFreq5 | 1.3.6.1.4.1.21239.5.2.30.1.9.1.21 | Integer32 | read-write | Compressor jump frequency 5 in tenths of a percent |
| I32 vrcCompCfgTempP | 1.3.6.1.4.1.21239.5.2.30.1.9.1.22 | Integer32 | read-write | Compressor temperature P in tenths of a degree. Units are given by temperatureUnits field in deviceInfo. The settable range is determined by the current temperature units. Celsius: 10 to 150 Fahrenheit: 18 to 269 |
| I32 vrcCompCfgTempI | 1.3.6.1.4.1.21239.5.2.30.1.9.1.23 | Integer32 | read-write | Compressor temperature I in seconds |
| I32 vrcCompCfgTempD | 1.3.6.1.4.1.21239.5.2.30.1.9.1.24 | Integer32 | read-write | Compressor temperature D in seconds |
| INT vrcCompCfgDriverFaultAlmCtrl | 1.3.6.1.4.1.21239.5.2.30.1.9.1.25 | INTEGER | read-write | Compressor driver fault alarm control: 2 = suspend 3 = open |
| INT vrcCompCfgDriverCommFailAlmCtrl | 1.3.6.1.4.1.21239.5.2.30.1.9.1.26 | INTEGER | read-write | Compressor driver communication failure alarm control: 2 = suspend 3 = open |
| INT vrcCompCfgFaultLockAlmCtrl | 1.3.6.1.4.1.21239.5.2.30.1.9.1.27 | INTEGER | read-write | Compressor fault lock alarm control: 2 = suspend 3 = open |
| vrcReturnPtTable | 1.3.6.1.4.1.21239.5.2.30.1.10 | not-accessible | Table that contains VRC return status | |
| vrcReturnPtEntry | 1.3.6.1.4.1.21239.5.2.30.1.10.1 | not-accessible | Entry in the vrcReturnPtTable: each entry represents return data for a VRC | |
| I32 vrcReturnPtIndex | 1.3.6.1.4.1.21239.5.2.30.1.10.1.1 | Integer32 | not-accessible | Unique id for each entry in the table |
| STR vrcReturnPtName | 1.3.6.1.4.1.21239.5.2.30.1.10.1.2 | SnmpAdminString | read-only | Return name (factory-assigned) |
| I32 vrcReturnPtTemp | 1.3.6.1.4.1.21239.5.2.30.1.10.1.3 | Integer32 | read-only | Return temperature value in tenths of a degree. Units are given by temperatureUnits field in deviceInfo. The range is determined by the current temperature units. Celsius: -400 to 1000 Fahrenheit: -400 to 2120 |
| T/F vrcReturnPtHighTempAlarm | 1.3.6.1.4.1.21239.5.2.30.1.10.1.4 | TruthValue | read-only | Return high temperature alarm state |
| T/F vrcReturnPtTempSensorFailAlarm | 1.3.6.1.4.1.21239.5.2.30.1.10.1.5 | TruthValue | read-only | Return temperature sensor failure alarm state |
| vrcReturnCfgTable | 1.3.6.1.4.1.21239.5.2.30.1.11 | not-accessible | Table used for VRC return configuration | |
| vrcReturnCfgEntry | 1.3.6.1.4.1.21239.5.2.30.1.11.1 | not-accessible | Entry in the vrcReturnCfgTable: each entry contains config fields for VRC return | |
| I32 vrcReturnCfgIndex | 1.3.6.1.4.1.21239.5.2.30.1.11.1.1 | Integer32 | not-accessible | Unique id for each entry in the table |
| I32 vrcReturnCfgOilCycle | 1.3.6.1.4.1.21239.5.2.30.1.11.1.2 | Integer32 | read-write | Return oil cycle in tenths of an hour |
| I32 vrcReturnCfgOilRunCapacity | 1.3.6.1.4.1.21239.5.2.30.1.11.1.3 | Integer32 | read-write | Return Oil run capacity (percent) |
| I32 vrcReturnCfgOilRunTime | 1.3.6.1.4.1.21239.5.2.30.1.11.1.4 | Integer32 | read-write | Return oil run time in minutes |
| I32 vrcReturnCfgTempCalValue | 1.3.6.1.4.1.21239.5.2.30.1.11.1.5 | Integer32 | read-write | Return temperature calibration value in tenths of a degree. Units are given by temperatureUnits field in deviceInfo. The settable range is determined by the current temperature units. Celsius: -100 to 100 Fahrenheit: -179 to 179 |
| I32 vrcReturnCfgTempSetting | 1.3.6.1.4.1.21239.5.2.30.1.11.1.6 | Integer32 | read-write | Return temperature setting in tenths of a degree. Units are given by temperatureUnits field in deviceInfo. The settable range is determined by the current temperature units. Celsius: 250 to 350 Fahrenheit: 770 to 949 |
| I32 vrcReturnCfgHighTempAlarmValue | 1.3.6.1.4.1.21239.5.2.30.1.11.1.7 | Integer32 | read-write | Return high temperature alarm value in tenths of a degree. Units are given by temperatureUnits field in deviceInfo. The settable range is determined by the current temperature units. Celsius: 300 to 450 Fahrenheit: 860 to 1129 |
| INT vrcReturnCfgHighTempAlarmCtrl | 1.3.6.1.4.1.21239.5.2.30.1.11.1.8 | INTEGER | read-write | Return high temperature alarm control: 1 = close 2 = suspend 3 = open |
| INT vrcReturnCfgTempSensFailAlmCtrl | 1.3.6.1.4.1.21239.5.2.30.1.11.1.9 | INTEGER | read-write | Return temperature sensor failure alarm control: 1 = close 2 = suspend 3 = open |
| vrcSupplyPtTable | 1.3.6.1.4.1.21239.5.2.30.1.12 | not-accessible | Table that contains VRC supply status | |
| vrcSupplyPtEntry | 1.3.6.1.4.1.21239.5.2.30.1.12.1 | not-accessible | Entry in the vrcSupplyPtTable: each entry represents supply data for a VRC | |
| I32 vrcSupplyPtIndex | 1.3.6.1.4.1.21239.5.2.30.1.12.1.1 | Integer32 | not-accessible | Unique id for each entry in the table |
| STR vrcSupplyPtName | 1.3.6.1.4.1.21239.5.2.30.1.12.1.2 | SnmpAdminString | read-only | Supply name (factory-assigned) |
| I32 vrcSupplyPtTemp | 1.3.6.1.4.1.21239.5.2.30.1.12.1.3 | Integer32 | read-only | Supply temperature value in tenths of a degree. Units are given by temperatureUnits field in deviceInfo. The range is determined by the current temperature units. Celsius: -400 to 1000 Fahrenheit: -400 to 2120 |
| T/F vrcSupplyPtLowTempAlarm | 1.3.6.1.4.1.21239.5.2.30.1.12.1.4 | TruthValue | read-only | Supply low temperature alarm state |
| T/F vrcSupplyPtHighTempAlarm | 1.3.6.1.4.1.21239.5.2.30.1.12.1.5 | TruthValue | read-only | Supply high temperature alarm state |
| T/F vrcSupplyPtTempSensorFailAlarm | 1.3.6.1.4.1.21239.5.2.30.1.12.1.6 | TruthValue | read-only | Supply temperature sensor failure alarm state |
| vrcSupplyCfgTable | 1.3.6.1.4.1.21239.5.2.30.1.13 | not-accessible | Table used for VRC supply configuration | |
| vrcSupplyCfgEntry | 1.3.6.1.4.1.21239.5.2.30.1.13.1 | not-accessible | Entry in the vrcSupplyCfgTable: each entry contains config fields for a VRC supply | |
| I32 vrcSupplyCfgIndex | 1.3.6.1.4.1.21239.5.2.30.1.13.1.1 | Integer32 | not-accessible | Unique id for each entry in the table |
| I32 vrcSupplyCfgTempCalValue | 1.3.6.1.4.1.21239.5.2.30.1.13.1.2 | Integer32 | read-write | Supply temperature calibration value in tenths of a degree. Units are given by temperatureUnits field in deviceInfo. The settable range is determined by the current temperature units. Celsius: -100 to 100 Fahrenheit: -179 to 179 |
| I32 vrcSupplyCfgTempSetting | 1.3.6.1.4.1.21239.5.2.30.1.13.1.3 | Integer32 | read-write | Supply temperature setting in tenths of a degree. Units are given by temperatureUnits field in deviceInfo. The settable range is determined by the current temperature units. Celsius: 130 to 280 Fahrenheit: 554 to 823 |
| I32 vrcSupplyCfgLowTempAlarmValue | 1.3.6.1.4.1.21239.5.2.30.1.13.1.4 | Integer32 | read-write | Supply low temperature alarm value in tenths of a degree. Units are given by temperatureUnits field in deviceInfo. The settable range is determined by the current temperature units. Celsius: 50 to 200 Fahrenheit: 410 to 679 |
| I32 vrcSupplyCfgHighTempAlarmValue | 1.3.6.1.4.1.21239.5.2.30.1.13.1.5 | Integer32 | read-write | Supply high temperature alarm value in tenths of a degree. Units are given by temperatureUnits field in deviceInfo. The settable range is determined by the current temperature units. Celsius: 200 to 350 Fahrenheit: 680 to 949 |
| INT vrcSupplyCfgLowTempAlmCtrl | 1.3.6.1.4.1.21239.5.2.30.1.13.1.6 | INTEGER | read-write | Supply low temperature alarm control: 1 = close 2 = suspend 3 = open |
| INT vrcSupplyCfgHighTempAlmCtrl | 1.3.6.1.4.1.21239.5.2.30.1.13.1.7 | INTEGER | read-write | Supply high temperature alarm control: 1 = close 2 = suspend 3 = open |
| INT vrcSupplyCfgTempSensFailAlmCtrl | 1.3.6.1.4.1.21239.5.2.30.1.13.1.8 | INTEGER | read-write | Supply temperature sensor failure alarm control: 1 = close 2 = suspend 3 = open |
| vrcPowerPtTable | 1.3.6.1.4.1.21239.5.2.30.1.14 | not-accessible | Table that contains VRC power status | |
| vrcPowerPtEntry | 1.3.6.1.4.1.21239.5.2.30.1.14.1 | not-accessible | Entry in the vrcPowerPtTable: each entry represents power data for a VRC | |
| I32 vrcPowerPtIndex | 1.3.6.1.4.1.21239.5.2.30.1.14.1.1 | Integer32 | not-accessible | Unique id for each entry in the table |
| STR vrcPowerPtName | 1.3.6.1.4.1.21239.5.2.30.1.14.1.2 | SnmpAdminString | read-only | Power name (factory-assigned) |
| I32 vrcPowerPtVoltage | 1.3.6.1.4.1.21239.5.2.30.1.14.1.3 | Integer32 | read-only | Power voltage measurement in tenths of a volt |
| I32 vrcPowerPtFrequency | 1.3.6.1.4.1.21239.5.2.30.1.14.1.4 | Integer32 | read-only | Power frequency measurement in tenths of hertz |
| T/F vrcPowerPtLowVoltageAlarm | 1.3.6.1.4.1.21239.5.2.30.1.14.1.5 | TruthValue | read-only | Power low voltage alarm state |
| T/F vrcPowerPtHighVoltageAlarm | 1.3.6.1.4.1.21239.5.2.30.1.14.1.6 | TruthValue | read-only | Power high voltage alarm state |
| T/F vrcPowerPtLossOfPhasePowerAlarm | 1.3.6.1.4.1.21239.5.2.30.1.14.1.7 | TruthValue | read-only | Phase power loss alarm state |
| T/F vrcPowerPtLossOfPowerAlarm | 1.3.6.1.4.1.21239.5.2.30.1.14.1.8 | TruthValue | read-only | Power loss alarm state |
| T/F vrcPowerPtFrequencyErrorAlarm | 1.3.6.1.4.1.21239.5.2.30.1.14.1.9 | TruthValue | read-only | Power frequency error alarm state |
| vrcPowerCfgTable | 1.3.6.1.4.1.21239.5.2.30.1.15 | not-accessible | Table used for VRC power configuration | |
| vrcPowerCfgEntry | 1.3.6.1.4.1.21239.5.2.30.1.15.1 | not-accessible | Entry in the vrcPowerCfgTable: each entry contains config fields for VRC power | |
| I32 vrcPowerCfgIndex | 1.3.6.1.4.1.21239.5.2.30.1.15.1.1 | Integer32 | not-accessible | Unique id for each entry in the table |
| I32 vrcPowerCfgLowVoltageSetting | 1.3.6.1.4.1.21239.5.2.30.1.15.1.2 | Integer32 | read-write | Power low voltage setting in volts |
| I32 vrcPowerCfgHighVoltageSetting | 1.3.6.1.4.1.21239.5.2.30.1.15.1.3 | Integer32 | read-write | Power high voltage setting in volts |
| INT vrcPowerCfgLowVoltageAlarmCtrl | 1.3.6.1.4.1.21239.5.2.30.1.15.1.4 | INTEGER | read-write | Power low voltage alarm control: 1 = close 2 = suspend 3 = open |
| INT vrcPowerCfgHighVoltageAlarmCtrl | 1.3.6.1.4.1.21239.5.2.30.1.15.1.5 | INTEGER | read-write | Power high voltage alarm control: 1 = close 2 = suspend 3 = open |
| INT vrcPowerCfgLossOfPowerAlarmCtrl | 1.3.6.1.4.1.21239.5.2.30.1.15.1.6 | INTEGER | read-write | Power loss alarm control: 1 = close 2 = suspend 3 = open |
| INT vrcPowerCfgFreqErrorAlarmCtrl | 1.3.6.1.4.1.21239.5.2.30.1.15.1.7 | INTEGER | read-write | Power frequency error alarm control: 1 = close 2 = suspend 3 = open |
| vrcOutdoorPtTable | 1.3.6.1.4.1.21239.5.2.30.1.16 | not-accessible | Table that contains VRC outdoor status | |
| vrcOutdoorPtEntry | 1.3.6.1.4.1.21239.5.2.30.1.16.1 | not-accessible | Entry in the vrcOutdoorPtTable: each entry represents data for a VRC outdoor | |
| I32 vrcOutdoorPtIndex | 1.3.6.1.4.1.21239.5.2.30.1.16.1.1 | Integer32 | not-accessible | Unique id for each entry in the table |
| STR vrcOutdoorPtName | 1.3.6.1.4.1.21239.5.2.30.1.16.1.2 | SnmpAdminString | read-only | Outdoor name (factory-assigned) |
| I32 vrcOutdoorPtTemp | 1.3.6.1.4.1.21239.5.2.30.1.16.1.3 | Integer32 | read-only | Outdoor temperature value in tenths of a degree. Units are given by temperatureUnits field in deviceInfo. The range is determined by the current temperature units. Celsius: -400 to 1000 Fahrenheit: -400 to 2120 |
| vrcDischPtTable | 1.3.6.1.4.1.21239.5.2.30.1.18 | not-accessible | Table that contains VRC discharge status | |
| vrcDischPtEntry | 1.3.6.1.4.1.21239.5.2.30.1.18.1 | not-accessible | Entry in the vrcDischPtTable: each entry represents discharge data for a VRC | |
| I32 vrcDischPtIndex | 1.3.6.1.4.1.21239.5.2.30.1.18.1.1 | Integer32 | not-accessible | Unique id for each entry in the table |
| STR vrcDischPtName | 1.3.6.1.4.1.21239.5.2.30.1.18.1.2 | SnmpAdminString | read-only | Discharge name (factory-assigned) |
| I32 vrcDischPtTemp | 1.3.6.1.4.1.21239.5.2.30.1.18.1.3 | Integer32 | read-write | Discharge temperature value in tenths of a degree. Units are given by temperatureUnits field in deviceInfo. The range is determined by the current temperature units. Celsius: -400 to 1560 Fahrenheit: -400 to 3128 |
| I32 vrcDischPtPressure | 1.3.6.1.4.1.21239.5.2.30.1.18.1.4 | Integer32 | read-write | Discharge air pressure value in tenths of a bar |
| T/F vrcDischPtHighTempAlarm | 1.3.6.1.4.1.21239.5.2.30.1.18.1.5 | TruthValue | read-only | Discharge high temperature alarm state |
| T/F vrcDischPtHighTempFreqAlarm | 1.3.6.1.4.1.21239.5.2.30.1.18.1.6 | TruthValue | read-only | Discharge high temperature frequently alarm state |
| T/F vrcDischPtTempSensorFailAlarm | 1.3.6.1.4.1.21239.5.2.30.1.18.1.7 | TruthValue | read-only | Discharge temperature sensor failure alarm state |
| vrcDischCfgTable | 1.3.6.1.4.1.21239.5.2.30.1.19 | not-accessible | Table used for VRC discharge configuration | |
| vrcDischCfgEntry | 1.3.6.1.4.1.21239.5.2.30.1.19.1 | not-accessible | Entry in the vrcDischCfgTable: each entry contains config fields for VRC discharge | |
| I32 vrcDischCfgIndex | 1.3.6.1.4.1.21239.5.2.30.1.19.1.1 | Integer32 | not-accessible | Unique id for each entry in the table |
| I32 vrcDischCfgTempCalValue | 1.3.6.1.4.1.21239.5.2.30.1.19.1.2 | Integer32 | read-write | Discharge temperature calibration value in tenths of a degree. Units are given by temperatureUnits field in deviceInfo. The settable range is determined by the current temperature units. Celsius: -100 to 100 Fahrenheit: -179 to 179 |
| I32 vrcDischCfgPressCalValue | 1.3.6.1.4.1.21239.5.2.30.1.19.1.3 | Integer32 | read-write | Discharge pressure calibration value in tenths of a bar |
| INT vrcDischCfgHighTempAlmCtrl | 1.3.6.1.4.1.21239.5.2.30.1.19.1.4 | INTEGER | read-write | Discharge high temperature alarm control: 2 = suspend 3 = open |
| INT vrcDischCfgHighTempFreqAlmCtrl | 1.3.6.1.4.1.21239.5.2.30.1.19.1.5 | INTEGER | read-write | Discharge high temperature frequenctly alarm control: 2 = suspend 3 = open |
| INT vrcDischCfgTempSensFailAlmCtrl | 1.3.6.1.4.1.21239.5.2.30.1.19.1.6 | INTEGER | read-write | Discharge temperature sensor failure alarm control: 2 = suspend 3 = open |
| vrcSuctPtTable | 1.3.6.1.4.1.21239.5.2.30.1.20 | not-accessible | Table that contains VRC suction status | |
| vrcSuctPtEntry | 1.3.6.1.4.1.21239.5.2.30.1.20.1 | not-accessible | Entry in the vrcSuctPtTable: each entry represents suction data for a VRC | |
| I32 vrcSuctPtIndex | 1.3.6.1.4.1.21239.5.2.30.1.20.1.1 | Integer32 | not-accessible | Unique id for each entry in the table |
| STR vrcSuctPtName | 1.3.6.1.4.1.21239.5.2.30.1.20.1.2 | SnmpAdminString | read-only | Suction name (factory-assigned) |
| I32 vrcSuctPtTemp | 1.3.6.1.4.1.21239.5.2.30.1.20.1.3 | Integer32 | read-only | Suction temperature in tenths of a degree. Units are given by temperatureUnits field in deviceInfo. The range is determined by the current temperature units. Celsius: -400 to 1000 Fahrenheit: -400 to 2120 |
| I32 vrcSuctPtPressure | 1.3.6.1.4.1.21239.5.2.30.1.20.1.4 | Integer32 | read-only | Suction air pressure in tenths of a bar |
| I32 vrcSuctPtSuperHeatTemp | 1.3.6.1.4.1.21239.5.2.30.1.20.1.5 | Integer32 | read-only | Suction super heat temperature in tenths of a degree. Units are given by temperatureUnits field in deviceInfo. The range is determined by the current temperature units. Celsius: -400 to 1000 Fahrenheit: -400 to 2120 |
| T/F vrcSuctPtTempSensorFailAlarm | 1.3.6.1.4.1.21239.5.2.30.1.20.1.6 | TruthValue | read-only | Suction temperature sensor failure alarm state |
| vrcSuctCfgTable | 1.3.6.1.4.1.21239.5.2.30.1.21 | not-accessible | Table used for VRC suction configuration | |
| vrcSuctCfgEntry | 1.3.6.1.4.1.21239.5.2.30.1.21.1 | not-accessible | Entry in the vrcSuctCfgTable: each entry contains config fields for VRC suction | |
| I32 vrcSuctCfgIndex | 1.3.6.1.4.1.21239.5.2.30.1.21.1.1 | Integer32 | not-accessible | Unique id for each entry in the table |
| I32 vrcSuctCfgPressCalValue | 1.3.6.1.4.1.21239.5.2.30.1.21.1.2 | Integer32 | read-write | Suction pressure calibration value in tenths of a bar |
| INT vrcSuctCfgTempSensFailAlmCtrl | 1.3.6.1.4.1.21239.5.2.30.1.21.1.3 | INTEGER | read-write | Suction temperature sensor failure alarm control: 2 = suspend 3 = open |
| trap | 1.3.6.1.4.1.21239.5.2.32767 | |||
| trapPrefix | 1.3.6.1.4.1.21239.5.2.32767.0 | |||
| NTF internalTestNOTIFY | 1.3.6.1.4.1.21239.5.2.32767.0.10101 | Test SNMP Trap | ||
| NTF pduMainAvailNOTIFY | 1.3.6.1.4.1.21239.5.2.32767.0.10305 | PDU availability trap | ||
| NTF pduTotalRealPowerNOTIFY | 1.3.6.1.4.1.21239.5.2.32767.0.10309 | PDU total real power trap | ||
| NTF pduTotalApparentPowerNOTIFY | 1.3.6.1.4.1.21239.5.2.32767.0.10310 | PDU total apparent power trap | ||
| NTF pduTotalPowerFactorNOTIFY | 1.3.6.1.4.1.21239.5.2.32767.0.10311 | PDU total power factor trap | ||
| NTF pduTotalEnergyNOTIFY | 1.3.6.1.4.1.21239.5.2.32767.0.10312 | PDU total energy trap | ||
| NTF pduPhaseVoltageNOTIFY | 1.3.6.1.4.1.21239.5.2.32767.0.10324 | PDU phase voltage trap | ||
| NTF pduPhaseCurrentNOTIFY | 1.3.6.1.4.1.21239.5.2.32767.0.10328 | PDU phase current trap | ||
| NTF pduPhaseRealPowerNOTIFY | 1.3.6.1.4.1.21239.5.2.32767.0.10332 | PDU phase real power trap | ||
| NTF pduPhaseApparentPowerNOTIFY | 1.3.6.1.4.1.21239.5.2.32767.0.10333 | PDU phase apparent power trap | ||
| NTF pduPhasePowerFactorNOTIFY | 1.3.6.1.4.1.21239.5.2.32767.0.10334 | PDU phase power factor trap | ||
| NTF pduPhaseEnergyNOTIFY | 1.3.6.1.4.1.21239.5.2.32767.0.10335 | PDU phase energy trap | ||
| NTF pduPhaseBalanceNOTIFY | 1.3.6.1.4.1.21239.5.2.32767.0.10337 | PDU phase balance trap | ||
| NTF pduPhaseCurrentCrestFactorNOTIFY | 1.3.6.1.4.1.21239.5.2.32767.0.10339 | PDU phase current crest factor trap | ||
| NTF pduBreakerCurrentNOTIFY | 1.3.6.1.4.1.21239.5.2.32767.0.10354 | PDU breaker current trap | ||
| NTF pduBreakerVoltageNOTIFY | 1.3.6.1.4.1.21239.5.2.32767.0.10358 | PDU breaker voltage trap | ||
| NTF pduBreakerRealPowerNOTIFY | 1.3.6.1.4.1.21239.5.2.32767.0.10362 | PDU breaker real power trap | ||
| NTF pduBreakerApparentPowerNOTIFY | 1.3.6.1.4.1.21239.5.2.32767.0.10363 | PDU breaker apparent power trap | ||
| NTF pduBreakerPowerFactorNOTIFY | 1.3.6.1.4.1.21239.5.2.32767.0.10364 | PDU breaker power factor trap | ||
| NTF pduBreakerEnergyNOTIFY | 1.3.6.1.4.1.21239.5.2.32767.0.10365 | PDU breaker energy trap | ||
| NTF pduLineCurrentNOTIFY | 1.3.6.1.4.1.21239.5.2.32767.0.10374 | PDU line current trap | ||
| NTF pduOutletMeterVoltageNOTIFY | 1.3.6.1.4.1.21239.5.2.32767.0.10385 | PDU outlet voltage trap | ||
| NTF pduOutletMeterCurrentNOTIFY | 1.3.6.1.4.1.21239.5.2.32767.0.10389 | PDU outlet current trap | ||
| NTF pduOutletMeterRealPowerNOTIFY | 1.3.6.1.4.1.21239.5.2.32767.0.10393 | PDU outlet real power trap | ||
| NTF pduOutletMeterApparentPowerNOTIFY | 1.3.6.1.4.1.21239.5.2.32767.0.10394 | PDU outlet apparent power trap | ||
| NTF pduOutletMeterPowerFactorNOTIFY | 1.3.6.1.4.1.21239.5.2.32767.0.10395 | PDU outlet power factor trap | ||
| NTF pduOutletMeterEnergyNOTIFY | 1.3.6.1.4.1.21239.5.2.32767.0.10396 | PDU outlet energy trap | ||
| NTF pduOutletCurrentCrestFactorNOTIFY | 1.3.6.1.4.1.21239.5.2.32767.0.10400 | PDU outlet current crest factor trap | ||
| NTF tempSensorAvailNOTIFY | 1.3.6.1.4.1.21239.5.2.32767.0.10404 | RT availability trap | ||
| NTF tempSensorTempNOTIFY | 1.3.6.1.4.1.21239.5.2.32767.0.10405 | RT temperature trap | ||
| NTF airFlowSensorAvailNOTIFY | 1.3.6.1.4.1.21239.5.2.32767.0.10504 | AFHT3 availability trap | ||
| NTF airFlowSensorTempNOTIFY | 1.3.6.1.4.1.21239.5.2.32767.0.10505 | AFHT3 temperature trap | ||
| NTF airFlowSensorFlowNOTIFY | 1.3.6.1.4.1.21239.5.2.32767.0.10506 | AFHT3 airflow trap | ||
| NTF airFlowSensorHumidityNOTIFY | 1.3.6.1.4.1.21239.5.2.32767.0.10507 | AFHT3 humidity trap | ||
| NTF airFlowSensorDewPointNOTIFY | 1.3.6.1.4.1.21239.5.2.32767.0.10508 | AFHT3 dewpoint trap | ||
| NTF t3hdSensorAvailNOTIFY | 1.3.6.1.4.1.21239.5.2.32767.0.10804 | T3HD availability trap | ||
| NTF t3hdSensorIntTempNOTIFY | 1.3.6.1.4.1.21239.5.2.32767.0.10806 | T3HD Internal temperature trap | ||
| NTF t3hdSensorIntHumidityNOTIFY | 1.3.6.1.4.1.21239.5.2.32767.0.10807 | T3HD Internal humidity trap | ||
| NTF t3hdSensorIntDewPointNOTIFY | 1.3.6.1.4.1.21239.5.2.32767.0.10808 | T3HD Internal dewpoint trap | ||
| NTF t3hdSensorExtATempNOTIFY | 1.3.6.1.4.1.21239.5.2.32767.0.10811 | T3HD External A temperature trap | ||
| NTF t3hdSensorExtBTempNOTIFY | 1.3.6.1.4.1.21239.5.2.32767.0.10814 | T3HD External B temperature trap | ||
| NTF thdSensorAvailNOTIFY | 1.3.6.1.4.1.21239.5.2.32767.0.10904 | THD availability trap | ||
| NTF thdSensorTempNOTIFY | 1.3.6.1.4.1.21239.5.2.32767.0.10905 | THD temperature trap | ||
| NTF thdSensorHumidityNOTIFY | 1.3.6.1.4.1.21239.5.2.32767.0.10906 | THD humidity trap | ||
| NTF thdSensorDewPointNOTIFY | 1.3.6.1.4.1.21239.5.2.32767.0.10907 | THD dewpoint trap | ||
| NTF a2dSensorAvailNOTIFY | 1.3.6.1.4.1.21239.5.2.32767.0.11104 | A2D availability trap | ||
| NTF a2dSensorValueNOTIFY | 1.3.6.1.4.1.21239.5.2.32767.0.11105 | A2D measurement trap | ||
| NTF humiditySensorAvailNOTIFY | 1.3.6.1.4.1.21239.5.2.32767.0.11204 | Remote humidity availability trap | ||
| NTF humiditySensorValueNOTIFY | 1.3.6.1.4.1.21239.5.2.32767.0.11205 | Remote humidity value trap | ||
| NTF sn2dSensorAvailNOTIFY | 1.3.6.1.4.1.21239.5.2.32767.0.11304 | SN-2D availability trap | ||
| NTF sn2dSensorDoor1StateNOTIFY | 1.3.6.1.4.1.21239.5.2.32767.0.11306 | SN-2D Door switch 1 state trap | ||
| NTF sn2dSensorDoor2StateNOTIFY | 1.3.6.1.4.1.21239.5.2.32767.0.11309 | SN-2D Door switch 2 state trap | ||
| NTF vrcMainAvailNOTIFY | 1.3.6.1.4.1.21239.5.2.32767.0.13001 | VRC availability trap | ||
| NTF vrcOutFanPtSpeedNOTIFY | 1.3.6.1.4.1.21239.5.2.32767.0.13002 | VRC out-fan speed trap | ||
| NTF vrcCompPtCapacityNOTIFY | 1.3.6.1.4.1.21239.5.2.32767.0.13003 | VRC compressor capacity trap | ||
| NTF vrcReturnPtTempNOTIFY | 1.3.6.1.4.1.21239.5.2.32767.0.13004 | VRC return temperature trap | ||
| NTF vrcSupplyPtTempNOTIFY | 1.3.6.1.4.1.21239.5.2.32767.0.13005 | VRC supply temperature trap | ||
| NTF vrcPowerPtVoltageNOTIFY | 1.3.6.1.4.1.21239.5.2.32767.0.13006 | VRC power voltage trap | ||
| NTF vrcPowerPtFrequencyNOTIFY | 1.3.6.1.4.1.21239.5.2.32767.0.13007 | VRC power frequency trap | ||
| NTF vrcOutdoorPtTempNOTIFY | 1.3.6.1.4.1.21239.5.2.32767.0.13008 | VRC outdoor temperature trap | ||
| NTF vrcDischPtTempNOTIFY | 1.3.6.1.4.1.21239.5.2.32767.0.13009 | VRC discharge temperature trap | ||
| NTF vrcDischPtPressureNOTIFY | 1.3.6.1.4.1.21239.5.2.32767.0.13010 | VRC discharge pressure trap | ||
| NTF vrcSuctPtTempNOTIFY | 1.3.6.1.4.1.21239.5.2.32767.0.13011 | VRC suction temperature trap | ||
| NTF vrcSuctPtPressureNOTIFY | 1.3.6.1.4.1.21239.5.2.32767.0.13012 | VRC suction pressure trap | ||
| NTF pduMainAvailCLEAR | 1.3.6.1.4.1.21239.5.2.32767.0.20305 | PDU availability clear trap | ||
| NTF pduTotalRealPowerCLEAR | 1.3.6.1.4.1.21239.5.2.32767.0.20309 | PDU total real power clear trap | ||
| NTF pduTotalApparentPowerCLEAR | 1.3.6.1.4.1.21239.5.2.32767.0.20310 | PDU total apparent power clear trap | ||
| NTF pduTotalPowerFactorCLEAR | 1.3.6.1.4.1.21239.5.2.32767.0.20311 | PDU total power factor clear trap | ||
| NTF pduTotalEnergyCLEAR | 1.3.6.1.4.1.21239.5.2.32767.0.20312 | PDU total energy clear trap | ||
| NTF pduPhaseVoltageCLEAR | 1.3.6.1.4.1.21239.5.2.32767.0.20324 | PDU phase voltage clear trap | ||
| NTF pduPhaseCurrentCLEAR | 1.3.6.1.4.1.21239.5.2.32767.0.20328 | PDU phase current clear trap | ||
| NTF pduPhaseRealPowerCLEAR | 1.3.6.1.4.1.21239.5.2.32767.0.20332 | PDU phase real power clear trap | ||
| NTF pduPhaseApparentPowerCLEAR | 1.3.6.1.4.1.21239.5.2.32767.0.20333 | PDU phase apparent power clear trap | ||
| NTF pduPhasePowerFactorCLEAR | 1.3.6.1.4.1.21239.5.2.32767.0.20334 | PDU phase power factor clear trap | ||
| NTF pduPhaseEnergyCLEAR | 1.3.6.1.4.1.21239.5.2.32767.0.20335 | PDU phase energy clear trap | ||
| NTF pduPhaseBalanceCLEAR | 1.3.6.1.4.1.21239.5.2.32767.0.20337 | PDU phase balance clear trap | ||
| NTF pduPhaseCurrentCrestFactorCLEAR | 1.3.6.1.4.1.21239.5.2.32767.0.20339 | PDU phase current crest factor clear trap | ||
| NTF pduBreakerCurrentCLEAR | 1.3.6.1.4.1.21239.5.2.32767.0.20354 | PDU breaker current clear trap | ||
| NTF pduBreakerVoltageCLEAR | 1.3.6.1.4.1.21239.5.2.32767.0.20358 | PDU breaker voltage clear trap | ||
| NTF pduBreakerRealPowerCLEAR | 1.3.6.1.4.1.21239.5.2.32767.0.20362 | PDU breaker real power clear trap | ||
| NTF pduBreakerApparentPowerCLEAR | 1.3.6.1.4.1.21239.5.2.32767.0.20363 | PDU breaker apparent power clear trap | ||
| NTF pduBreakerPowerFactorCLEAR | 1.3.6.1.4.1.21239.5.2.32767.0.20364 | PDU breaker power factor clear trap | ||
| NTF pduBreakerEnergyCLEAR | 1.3.6.1.4.1.21239.5.2.32767.0.20365 | PDU breaker energy clear trap | ||
| NTF pduLineCurrentCLEAR | 1.3.6.1.4.1.21239.5.2.32767.0.20374 | PDU line current clear trap | ||
| NTF pduOutletMeterVoltageCLEAR | 1.3.6.1.4.1.21239.5.2.32767.0.20385 | PDU outlet voltage clear trap | ||
| NTF pduOutletMeterCurrentCLEAR | 1.3.6.1.4.1.21239.5.2.32767.0.20389 | PDU outlet current clear trap | ||
| NTF pduOutletMeterRealPowerCLEAR | 1.3.6.1.4.1.21239.5.2.32767.0.20393 | PDU outlet real power clear trap | ||
| NTF pduOutletMeterApparentPowerCLEAR | 1.3.6.1.4.1.21239.5.2.32767.0.20394 | PDU outlet apparent power clear trap | ||
| NTF pduOutletMeterPowerFactorCLEAR | 1.3.6.1.4.1.21239.5.2.32767.0.20395 | PDU outlet power factor clear trap | ||
| NTF pduOutletMeterEnergyCLEAR | 1.3.6.1.4.1.21239.5.2.32767.0.20396 | PDU outlet energy clear trap | ||
| NTF pduOutletCurrentCrestFactorCLEAR | 1.3.6.1.4.1.21239.5.2.32767.0.20400 | PDU outlet current crest factor clear trap | ||
| NTF tempSensorAvailCLEAR | 1.3.6.1.4.1.21239.5.2.32767.0.20404 | RT availability clear trap | ||
| NTF tempSensorTempCLEAR | 1.3.6.1.4.1.21239.5.2.32767.0.20405 | RT temperature clear trap | ||
| NTF airFlowSensorAvailCLEAR | 1.3.6.1.4.1.21239.5.2.32767.0.20504 | AFHT3 availability clear trap | ||
| NTF airFlowSensorTempCLEAR | 1.3.6.1.4.1.21239.5.2.32767.0.20505 | AFHT3 temperature clear trap | ||
| NTF airFlowSensorFlowCLEAR | 1.3.6.1.4.1.21239.5.2.32767.0.20506 | AFHT3 airflow clear trap | ||
| NTF airFlowSensorHumidityCLEAR | 1.3.6.1.4.1.21239.5.2.32767.0.20507 | AFHT3 humidity clear trap | ||
| NTF airFlowSensorDewPointCLEAR | 1.3.6.1.4.1.21239.5.2.32767.0.20508 | AFHT3 dewpoint clear trap | ||
| NTF t3hdSensorAvailCLEAR | 1.3.6.1.4.1.21239.5.2.32767.0.20804 | T3HD availability clear trap | ||
| NTF t3hdSensorIntTempCLEAR | 1.3.6.1.4.1.21239.5.2.32767.0.20806 | T3HD Internal temperature clear trap | ||
| NTF t3hdSensorIntHumidityCLEAR | 1.3.6.1.4.1.21239.5.2.32767.0.20807 | T3HD Internal humidity clear trap | ||
| NTF t3hdSensorIntDewPointCLEAR | 1.3.6.1.4.1.21239.5.2.32767.0.20808 | T3HD Internal dewpoint clear trap | ||
| NTF t3hdSensorExtATempCLEAR | 1.3.6.1.4.1.21239.5.2.32767.0.20811 | T3HD External A temperature clear trap | ||
| NTF t3hdSensorExtBTempCLEAR | 1.3.6.1.4.1.21239.5.2.32767.0.20814 | T3HD External B temperature clear trap | ||
| NTF thdSensorAvailCLEAR | 1.3.6.1.4.1.21239.5.2.32767.0.20904 | THD availability clear trap | ||
| NTF thdSensorTempCLEAR | 1.3.6.1.4.1.21239.5.2.32767.0.20905 | THD temperature clear trap | ||
| NTF thdSensorHumidityCLEAR | 1.3.6.1.4.1.21239.5.2.32767.0.20906 | THD humidity clear trap | ||
| NTF thdSensorDewPointCLEAR | 1.3.6.1.4.1.21239.5.2.32767.0.20907 | THD dewpoint clear trap | ||
| NTF a2dSensorAvailCLEAR | 1.3.6.1.4.1.21239.5.2.32767.0.21104 | A2D availability clear trap | ||
| NTF a2dSensorValueCLEAR | 1.3.6.1.4.1.21239.5.2.32767.0.21105 | A2D measurement clear trap | ||
| NTF humiditySensorAvailCLEAR | 1.3.6.1.4.1.21239.5.2.32767.0.21204 | Remote humidity availability clear trap | ||
| NTF humiditySensorValueCLEAR | 1.3.6.1.4.1.21239.5.2.32767.0.21205 | Remote humidity value clear trap | ||
| NTF sn2dSensorAvailCLEAR | 1.3.6.1.4.1.21239.5.2.32767.0.21304 | SN-2D availability clear trap | ||
| NTF sn2dSensorDoor1StateCLEAR | 1.3.6.1.4.1.21239.5.2.32767.0.21306 | SN-2D Door switch 1 state clear trap | ||
| NTF sn2dSensorDoor2StateCLEAR | 1.3.6.1.4.1.21239.5.2.32767.0.21309 | SN-2D Door switch 2 state clear trap | ||
| NTF vrcMainAvailCLEAR | 1.3.6.1.4.1.21239.5.2.32767.0.23001 | VRC availability clear trap | ||
| NTF vrcOutFanPtSpeedCLEAR | 1.3.6.1.4.1.21239.5.2.32767.0.23002 | VRC out-fan speed clear trap | ||
| NTF vrcCompPtCapacityCLEAR | 1.3.6.1.4.1.21239.5.2.32767.0.23003 | VRC compressor capacity clear trap | ||
| NTF vrcReturnPtTempCLEAR | 1.3.6.1.4.1.21239.5.2.32767.0.23004 | VRC return temperature clear trap | ||
| NTF vrcSupplyPtTempCLEAR | 1.3.6.1.4.1.21239.5.2.32767.0.23005 | VRC supply temperature clear trap | ||
| NTF vrcPowerPtVoltageCLEAR | 1.3.6.1.4.1.21239.5.2.32767.0.23006 | VRC power voltage clear trap | ||
| NTF vrcPowerPtFrequencyCLEAR | 1.3.6.1.4.1.21239.5.2.32767.0.23007 | VRC power frequency clear trap | ||
| NTF vrcOutdoorPtTempCLEAR | 1.3.6.1.4.1.21239.5.2.32767.0.23008 | VRC outdoor temperature clear trap | ||
| NTF vrcDischPtTempCLEAR | 1.3.6.1.4.1.21239.5.2.32767.0.23009 | VRC discharge temperature clear trap | ||
| NTF vrcDischPtPressureCLEAR | 1.3.6.1.4.1.21239.5.2.32767.0.23010 | VRC discharge pressure clear trap | ||
| NTF vrcSuctPtTempCLEAR | 1.3.6.1.4.1.21239.5.2.32767.0.23011 | VRC suction temperature clear trap | ||
| NTF vrcSuctPtPressureCLEAR | 1.3.6.1.4.1.21239.5.2.32767.0.23012 | VRC suction pressure clear trap | ||
| trapObj | 1.3.6.1.4.1.21239.5.2.32767.1 | |||
| INT trapSeverity | 1.3.6.1.4.1.21239.5.2.32767.1.1 | INTEGER | accessible-for-notify | Indicates the severity of the trap: 0 = None 1 = Warning 2 = Alarm |
| INT trapThreshType | 1.3.6.1.4.1.21239.5.2.32767.1.2 | INTEGER | accessible-for-notify | Only sent for threshold alarms. Identifies the threshold type: 1 = Low 2 = High |
| common | 1.3.6.1.4.1.21239.42 | |||
| identity | 1.3.6.1.4.1.21239.42.1 | |||
| r05 | 1.3.6.1.4.1.21239.42.1.15 | Value given for sysObjectID on R-Series units | ||
| i03 | 1.3.6.1.4.1.21239.42.1.53 | Value given for sysObjectID on IMD3 units |
RFC description
Monitors Vertiv V5 power and cooling infrastructure including UPS, PDU, and thermal management.
Start monitoring Vertiv UPS units, Vertiv PDUs, Vertiv precision cooling/thermal management systems (identity/firmware/temperature status) with a free 30-day trial of IPNetwork Monitor. Import MIBs, browse SNMP OIDs, create custom SNMP monitors, configure alerts, and monitor any SNMP-enabled network device from a single console.