All MIBs › UNITRENDS-SNMP
Organization: Unitrends
Last Updated: 2016-07-28
Category: Power and Environmental Monitoring
Description: Monitors Unitrends backup appliance job status, alerts, and storage health via SNMP.
Start monitoring vendor-neutral, standards-based MIB, any SNMPv3-capable network device (SNMP engine identity/boot/clock status) with a free 30-day trial of IPNetwork Monitor. Import MIBs, browse SNMP OIDs, create custom SNMP monitors, configure alerts, and monitor any SNMP-enabled network device from a single console.
What Is UNITRENDS-SNMP?
UNITRENDS-SNMP is the Unitrends proprietary MIB (enterprise OID 21865) for Unitrends Rapid Recovery backup appliances, providing GET and TRAP access to system health information. Its objects report asset ID, hostname, kernel/BIOS/firmware version, total/used/free memory, CPU usage, baseboard identification, network configuration (DHCP mode, IP/MAC/subnet/gateway), manufacture date, software release, and a voltage-probe table monitoring individual voltage rails. As a hardware/software-status MIB it lets an administrator monitor a backup appliance's CPU/memory load and voltage rails as early-warning indicators before a scheduled backup job is affected by a hardware problem. It is deployed on Unitrends Rapid Recovery backup appliances. Engineers can download the UNITRENDS-SNMP file directly to load it into their MIB browser.
IPNetwork Monitor allows you to monitor SNMP objects defined in UNITRENDS-SNMP. Use the built-in SNMP Monitoring Browser to explore available variables, view their current values and descriptions, and select the objects you want to monitor. You can then create SNMP monitors, configure thresholds, and receive alerts when monitored values change.
Supported Devices
- Unitrends Rapid Recovery backup appliances
Monitoring Examples
An administrator monitors mgtInfoCpuUsed and mgtInfoMemoryFree on a Unitrends appliance to confirm it has enough headroom before a large scheduled backup job begins.
What Can Be Monitored
- CPU/memory usage
- voltage rail readings
- system identification
This MIB depends on
Related MIBs
Imported Objects
From SNMPv2-SMI
| Counter32 | |
| Integer32 | |
| MODULE-IDENTITY | |
| NOTIFICATION-TYPE | |
| OBJECT-TYPE | |
| enterprises |
From SNMPv2-TC
| DisplayString | |
| TEXTUAL-CONVENTION |
OIDs
| OID symbolic | OID numeric | Type | Access | Description |
|---|---|---|---|---|
| unitrends | 1.3.6.1.4.1.21865 | |||
| rr | 1.3.6.1.4.1.21865.1 | |||
| trapMembers | 1.3.6.1.4.1.21865.1.1 | |||
| STR trapType | 1.3.6.1.4.1.21865.1.1.1 | DisplayString | read-only | The type/category of the event. |
| STR trapAffectedObj | 1.3.6.1.4.1.21865.1.1.2 | DisplayString | read-only | The affected object of the event. |
| STR trapDescription | 1.3.6.1.4.1.21865.1.1.3 | DisplayString | read-only | Descriptive information about the event. |
| UNI trapSeverity | 1.3.6.1.4.1.21865.1.1.4 | UnitrendsSeverity | read-only | Severity of the event |
| INT trapStatus | 1.3.6.1.4.1.21865.1.1.5 | INTEGER | read-only | The status of the event. |
| STR trapLicenseId | 1.3.6.1.4.1.21865.1.1.6 | DisplayString | read-only | The License Identity of the system for this event. |
| STR trapDpuId | 1.3.6.1.4.1.21865.1.1.7 | DisplayString | read-only | The DPU Identity of the system for this event. |
| STR trapReleaseVersion | 1.3.6.1.4.1.21865.1.1.8 | DisplayString | read-only | The Release Version of the system for this event. |
| trapGroups | 1.3.6.1.4.1.21865.1.2 | |||
| trap100 | 1.3.6.1.4.1.21865.1.2.100 | |||
| trapPrefix | 1.3.6.1.4.1.21865.1.2.100.0 | |||
| NTF trapGroupClients | 1.3.6.1.4.1.21865.1.2.100.0.1 | The client state has changed. | ||
| NTF trapGroup3Ware | 1.3.6.1.4.1.21865.1.2.100.0.2 | The 3Ware state has changed. | ||
| NTF trapGroupPCI | 1.3.6.1.4.1.21865.1.2.100.0.3 | The PCI state has changed. | ||
| NTF trapGroupProcess | 1.3.6.1.4.1.21865.1.2.100.0.5 | The Process state has changed. | ||
| NTF trapGroupDisk | 1.3.6.1.4.1.21865.1.2.100.0.6 | The Disk state has changed. | ||
| NTF trapGroupCEP | 1.3.6.1.4.1.21865.1.2.100.0.7 | The CEP state has changed. | ||
| NTF trapGroupDPU | 1.3.6.1.4.1.21865.1.2.100.0.8 | The DPU state has changed. | ||
| NTF trapGroupRAID | 1.3.6.1.4.1.21865.1.2.100.0.9 | The RAID state has changed. | ||
| NTF trapGroupBackup | 1.3.6.1.4.1.21865.1.2.100.0.10 | The Backup state has changed. | ||
| NTF trapGroupArchive | 1.3.6.1.4.1.21865.1.2.100.0.11 | The Archive state has changed. | ||
| NTF trapGroupVersion | 1.3.6.1.4.1.21865.1.2.100.0.12 | The Version state has changed. | ||
| NTF trapGroupNetwork | 1.3.6.1.4.1.21865.1.2.100.0.14 | The Network state has changed. | ||
| NTF trapGroupDiskHealth | 1.3.6.1.4.1.21865.1.2.100.0.15 | The Disk Health state has changed. | ||
| NTF trapGroupIPMI | 1.3.6.1.4.1.21865.1.2.100.0.16 | The IPMI state has changed. | ||
| NTF trapGroupInstall | 1.3.6.1.4.1.21865.1.2.100.0.17 | The Install state has changed. | ||
| NTF trapGroupTest | 1.3.6.1.4.1.21865.1.2.100.0.99 | A Test trap was issued. | ||
| bpGroup | 1.3.6.1.4.1.21865.1.3 | |||
| unitrendsSnmpModule | 1.3.6.1.4.1.21865.1.3.1 | This SNMP MIB module supports the Unitrends Rapid Recovery backup appliances for monitoring various components, providing SNMP access to GET and TRAP information, and support events through the NOTIFICATION-TYPE construct. Version: 1.4 07/28/2016 Unitrends copyright information 2013-2016 | ||
| bpBackupGroup | 1.3.6.1.4.1.21865.1.3.10 | |||
| INT backupProbeInstances | 1.3.6.1.4.1.21865.1.3.10.1 | INTEGER | read-only | This attribute denotes the number of Backup entries available on the system |
| backupProbeTable | 1.3.6.1.4.1.21865.1.3.10.2 | not-accessible | This object defines the Backup Probe Table. | |
| backupProbeTableEntry | 1.3.6.1.4.1.21865.1.3.10.2.1 | not-accessible | This defines the Backup Probe Table Entry matching the Backups Report. | |
| ONE backupIndex | 1.3.6.1.4.1.21865.1.3.10.2.1.1 | OneBasedIndex | read-only | This is an index (one based) for the backup in the list. |
| INT backupId | 1.3.6.1.4.1.21865.1.3.10.2.1.2 | INTEGER | read-only | This is the unique backup ID number of the backup. |
| STR backupClient | 1.3.6.1.4.1.21865.1.3.10.2.1.3 | DisplayString | read-only | The Client Name for the backup. |
| STR backupStatusString | 1.3.6.1.4.1.21865.1.3.10.2.1.4 | DisplayString | read-only | The Status String for the backup. |
| INT backupStatusValue | 1.3.6.1.4.1.21865.1.3.10.2.1.5 | INTEGER | read-only | The Status Value for the backup. |
| STR backupTime | 1.3.6.1.4.1.21865.1.3.10.2.1.6 | DisplayString | read-only | The Date/Time for the backup. |
| STR backupType | 1.3.6.1.4.1.21865.1.3.10.2.1.7 | DisplayString | read-only | The Backup Type for the backup. |
| STR backupSize | 1.3.6.1.4.1.21865.1.3.10.2.1.8 | DisplayString | read-only | The Size in MB of the backup. |
| INT backupNumFiles | 1.3.6.1.4.1.21865.1.3.10.2.1.9 | INTEGER | read-only | The Number of Files in the backup. |
| INT backupIsLast | 1.3.6.1.4.1.21865.1.3.10.2.1.10 | INTEGER | read-only | Set to 1 if this is the last backup of this type. |
| bpCapacityGroup | 1.3.6.1.4.1.21865.1.3.20 | |||
| INT capacityProbeInstances | 1.3.6.1.4.1.21865.1.3.20.1 | INTEGER | read-only | This attribute denotes the number of Capacity entries available on the system |
| capacityProbeTable | 1.3.6.1.4.1.21865.1.3.20.2 | not-accessible | This object defines the Capacity Probe Table. | |
| capacityProbeTableEntry | 1.3.6.1.4.1.21865.1.3.20.2.1 | not-accessible | This object defines the Capacity Probe Table Entry. | |
| ONE capacityIndex | 1.3.6.1.4.1.21865.1.3.20.2.1.1 | OneBasedIndex | read-only | This attribute defines the index (one based) of the capacity. |
| INT capacityDeviceId | 1.3.6.1.4.1.21865.1.3.20.2.1.2 | INTEGER | read-only | This attribute defines the unique Device ID of the device. |
| STR capacityDeviceName | 1.3.6.1.4.1.21865.1.3.20.2.1.3 | DisplayString | read-only | The Device Name for the device whose capacity is reported. |
| STR capacityDeviceFilename | 1.3.6.1.4.1.21865.1.3.20.2.1.4 | DisplayString | read-only | The Device Filename for the device whose capacity is reported. |
| STR capacitySize | 1.3.6.1.4.1.21865.1.3.20.2.1.5 | DisplayString | read-only | The Capacity or total logical Size of this device. |
| STR capacityUsed | 1.3.6.1.4.1.21865.1.3.20.2.1.6 | DisplayString | read-only | The amount of space Used on this device. |
| STR capacityFree | 1.3.6.1.4.1.21865.1.3.20.2.1.7 | DisplayString | read-only | The amount of Free space on this device. |
| bpReplicationGroup | 1.3.6.1.4.1.21865.1.3.30 | |||
| INT replicationProbeInstances | 1.3.6.1.4.1.21865.1.3.30.1 | INTEGER | read-only | This attribute denotes the number of Replication entries available on the system |
| replicationProbeTable | 1.3.6.1.4.1.21865.1.3.30.2 | not-accessible | This object defines the Replication Probe Table. | |
| replicationProbeTableEntry | 1.3.6.1.4.1.21865.1.3.30.2.1 | not-accessible | This object defines the Replication Probe Table Entry. | |
| ONE replicationIndex | 1.3.6.1.4.1.21865.1.3.30.2.1.1 | OneBasedIndex | read-only | This attribute defines the index (one based) of the replication. |
| INT replicationBackupNo | 1.3.6.1.4.1.21865.1.3.30.2.1.2 | INTEGER | read-only | This attribute defines the backup number of the replication job. |
| STR replicationClient | 1.3.6.1.4.1.21865.1.3.30.2.1.3 | DisplayString | read-only | The Client Name for the replication job. |
| STR replicationDestination | 1.3.6.1.4.1.21865.1.3.30.2.1.4 | DisplayString | read-only | The Destination Name for the replication job. |
| STR replicationTime | 1.3.6.1.4.1.21865.1.3.30.2.1.5 | DisplayString | read-only | The Date-Time for the replication job. |
| INT replicationSize | 1.3.6.1.4.1.21865.1.3.30.2.1.6 | INTEGER | read-only | This attribute defines the Size of the replication job. |
| STR replicationStatusString | 1.3.6.1.4.1.21865.1.3.30.2.1.7 | DisplayString | read-only | The Status String for the replication job. |
| INT replicationStatus | 1.3.6.1.4.1.21865.1.3.30.2.1.8 | INTEGER | read-only | This attribute defines the status of the replication job. |
| bpArchiveGroup | 1.3.6.1.4.1.21865.1.3.40 | |||
| INT archiveProbeInstances | 1.3.6.1.4.1.21865.1.3.40.1 | INTEGER | read-only | This attribute denotes the number of Archive entries available on the system |
| archiveProbeTable | 1.3.6.1.4.1.21865.1.3.40.2 | not-accessible | This object defines the Archive Probe Table. | |
| archiveProbeTableEntry | 1.3.6.1.4.1.21865.1.3.40.2.1 | not-accessible | This object defines the Archive Probe Table Entry. | |
| ONE archiveIndex | 1.3.6.1.4.1.21865.1.3.40.2.1.1 | OneBasedIndex | read-only | This attribute defines the index (one based) of the archive. |
| INT archiveDeviceId | 1.3.6.1.4.1.21865.1.3.40.2.1.2 | INTEGER | read-only | This attribute defines the unique Device ID of the archive. |
| STR archiveClient | 1.3.6.1.4.1.21865.1.3.40.2.1.3 | DisplayString | read-only | The Client Name for the archive. |
| INT archiveSuccess | 1.3.6.1.4.1.21865.1.3.40.2.1.4 | INTEGER | read-only | This attribute is =1 if the archive job was successful. |
| INT archiveSize | 1.3.6.1.4.1.21865.1.3.40.2.1.5 | INTEGER | read-only | This attribute defines the Size in MB of the archive job. |
| STR archiveBackupTime | 1.3.6.1.4.1.21865.1.3.40.2.1.6 | DisplayString | read-only | The Date-Time of the archive. |
| INT archiveBackupType | 1.3.6.1.4.1.21865.1.3.40.2.1.7 | INTEGER | read-only | This attribute defines the Backup Type of the archive. |
| INT archiveBackupNo | 1.3.6.1.4.1.21865.1.3.40.2.1.8 | INTEGER | read-only | This defines the Backup Number for the archive. |
| STR archiveOSType | 1.3.6.1.4.1.21865.1.3.40.2.1.9 | DisplayString | read-only | The Client OS Type of the archive. |
| STR archiveErrorMsg | 1.3.6.1.4.1.21865.1.3.40.2.1.10 | DisplayString | read-only | The Error Message for the archive job, if any. |
| INT archiveElapsedSec | 1.3.6.1.4.1.21865.1.3.40.2.1.11 | INTEGER | read-only | The Elapsed time in seconds for the archive job. |
| INT archiveCompressed | 1.3.6.1.4.1.21865.1.3.40.2.1.12 | INTEGER | read-only | Set to 1 if the archive is compressed. |
| INT archiveEncrypted | 1.3.6.1.4.1.21865.1.3.40.2.1.13 | INTEGER | read-only | Set to 1 if the archive is encrypted. |
| ipmiGroup | 1.3.6.1.4.1.21865.1.4 | |||
| coolingGroup | 1.3.6.1.4.1.21865.1.4.10 | |||
| INT coolingDeviceInstances | 1.3.6.1.4.1.21865.1.4.10.1 | INTEGER | read-only | This attribute denotes the number of fan sensors available on the system |
| coolingDeviceTable | 1.3.6.1.4.1.21865.1.4.10.2 | not-accessible | This object defines the Cooling Device Table. | |
| coolingDeviceTableEntry | 1.3.6.1.4.1.21865.1.4.10.2.1 | not-accessible | This object defines the Cooling Device Table Entry | |
| ONE coolingDeviceIndex | 1.3.6.1.4.1.21865.1.4.10.2.1.1 | OneBasedIndex | read-only | This attribute defines the index (one based) of the cooling device. |
| INT coolingDeviceId | 1.3.6.1.4.1.21865.1.4.10.2.1.2 | INTEGER | read-only | This attribute defines an unique ID for the cooling device |
| STR coolingDeviceDescription | 1.3.6.1.4.1.21865.1.4.10.2.1.3 | DisplayString | read-only | This attribute textually describes the cooling device. |
| STR coolingDeviceStatusString | 1.3.6.1.4.1.21865.1.4.10.2.1.4 | DisplayString | read-only | Current status of the sensor will be one of the following strings: OK, Error, Degraded or Unknown. |
| UNI coolingDeviceStatus | 1.3.6.1.4.1.21865.1.4.10.2.1.5 | UnitrendsStatus | read-only | Current health status of the sensor. |
| STR coolingDeviceReading | 1.3.6.1.4.1.21865.1.4.10.2.1.6 | DisplayString | read-only | This attribute contains the current fan sensor reading, measured in the units specified by the Fan Units attribute. |
| STR coolingDeviceUpperCriticalThreshold | 1.3.6.1.4.1.21865.1.4.10.2.1.7 | DisplayString | read-only | This attribute contains the major error threshold level for the fan. The threshold is given in the units specified by the Fan Units attribute. This attribute may not apply to all fan types. |
| STR coolingDeviceLowerCriticalThreshold | 1.3.6.1.4.1.21865.1.4.10.2.1.8 | DisplayString | read-only | This attribute contains the lower critical threshold level for the fan. The threshold is given in the units specified by the Fan Units attribute. This attribute may not apply to all fan types. |
| tempGroup | 1.3.6.1.4.1.21865.1.4.20 | |||
| INT temperatureProbeInstances | 1.3.6.1.4.1.21865.1.4.20.1 | INTEGER | read-only | This attribute denotes the number of temperature sensors available on the system |
| temperatureProbeTable | 1.3.6.1.4.1.21865.1.4.20.2 | not-accessible | This object defines the Temperature Probe Table. | |
| temperatureProbeTableEntry | 1.3.6.1.4.1.21865.1.4.20.2.1 | not-accessible | This object defines the Temperature Probe Table Entry. | |
| ONE temperatureIndex | 1.3.6.1.4.1.21865.1.4.20.2.1.1 | OneBasedIndex | read-only | This attribute defines the index (one based) of the temperature probe. |
| INT temperatureDeviceId | 1.3.6.1.4.1.21865.1.4.20.2.1.2 | INTEGER | read-only | This attribute defines a unique ID for the temperature probe. |
| STR temperatureDescription | 1.3.6.1.4.1.21865.1.4.20.2.1.3 | DisplayString | read-only | This attribute textually describes the temperature probe. |
| STR temperatureStatusString | 1.3.6.1.4.1.21865.1.4.20.2.1.4 | DisplayString | read-only | Current status of the sensor will be one of the following strings: OK, Error, Degraded or Unknown. |
| UNI temperatureStatus | 1.3.6.1.4.1.21865.1.4.20.2.1.5 | UnitrendsStatus | read-only | Current health status of the sensor. |
| STR temperatureReading | 1.3.6.1.4.1.21865.1.4.20.2.1.6 | DisplayString | read-only | The present temperature reading of this temperature probe in 1/10th degrees C. 0x8000000 denotes 'unknown'. |
| STR temperatureUpperCriticalThreshold | 1.3.6.1.4.1.21865.1.4.20.2.1.7 | DisplayString | read-only | The upper critical threshold for the temperature probe, in /10th degrees C. 0x80000000 denotes 'unknown'. |
| STR temperatureLowerCriticalThreshold | 1.3.6.1.4.1.21865.1.4.20.2.1.8 | DisplayString | read-only | The lower critical threshold for the temperature probe, in 1/10 degrees C. 0x80000000 denotes 'unknown'. |
| voltageGroup | 1.3.6.1.4.1.21865.1.4.30 | |||
| INT voltageProbeInstances | 1.3.6.1.4.1.21865.1.4.30.1 | INTEGER | read-only | This attribute denotes the number of voltage sensors available on the system |
| voltageProbeTable | 1.3.6.1.4.1.21865.1.4.30.2 | not-accessible | This object defines the Voltage Probe Table. | |
| voltageProbeTableEntry | 1.3.6.1.4.1.21865.1.4.30.2.1 | not-accessible | This object defines the Voltage Probe Table Entry. | |
| ONE voltageIndex | 1.3.6.1.4.1.21865.1.4.30.2.1.1 | OneBasedIndex | read-only | This attribute defines the index (one based) of the voltage probe. |
| INT voltageDeviceId | 1.3.6.1.4.1.21865.1.4.30.2.1.2 | INTEGER | read-only | This attribute defines an unique ID for the voltage probe |
| STR voltageDescription | 1.3.6.1.4.1.21865.1.4.30.2.1.3 | DisplayString | read-only | This attribute textually describes the voltage probe. |
| STR voltageStatusString | 1.3.6.1.4.1.21865.1.4.30.2.1.4 | DisplayString | read-only | Current status of the sensor will be one of the following strings: OK, Error, Degraded or Unknown. |
| UNI voltageStatus | 1.3.6.1.4.1.21865.1.4.30.2.1.5 | UnitrendsStatus | read-only | Current health status of the sensor. |
| STR voltageReading | 1.3.6.1.4.1.21865.1.4.30.2.1.6 | DisplayString | read-only | The current reading of the voltage probe. |
| STR voltageUpperCriticalThreshold | 1.3.6.1.4.1.21865.1.4.30.2.1.7 | DisplayString | read-only | The upper critical threshold for the voltage probe, in millivolts. |
| STR voltageLowerCriticalThreshold | 1.3.6.1.4.1.21865.1.4.30.2.1.8 | DisplayString | read-only | The lower non-critical threshold for the voltage probe, in millivolts. |
| eventlogGroup | 1.3.6.1.4.1.21865.1.4.40 | |||
| INT eventlogProbeInstances | 1.3.6.1.4.1.21865.1.4.40.1 | INTEGER | read-only | This attribute denotes the number of event log entries available on the system |
| eventlogProbeTable | 1.3.6.1.4.1.21865.1.4.40.2 | not-accessible | This object defines the Voltage Probe Table. | |
| eventlogProbeTableEntry | 1.3.6.1.4.1.21865.1.4.40.2.1 | not-accessible | This object defines the Temperature Probe Table Entry. | |
| STR eventlogEntryDescription | 1.3.6.1.4.1.21865.1.4.40.2.1.2 | DisplayString | read-only | This object contains the IPMI System Event Log entry description. |
| diskGroup | 1.3.6.1.4.1.21865.1.5 | |||
| physdiskGroup | 1.3.6.1.4.1.21865.1.5.10 | |||
| INT physdiskProbeInstances | 1.3.6.1.4.1.21865.1.5.10.1 | INTEGER | read-only | This attribute denotes the number of PhysDisk entries available on the system |
| physdiskProbeTable | 1.3.6.1.4.1.21865.1.5.10.2 | not-accessible | This object defines the PhysDisk Probe Table. | |
| physdiskProbeTableEntry | 1.3.6.1.4.1.21865.1.5.10.2.1 | not-accessible | This object defines the PhysDisk Probe Table Entry. | |
| ONE physdiskIndex | 1.3.6.1.4.1.21865.1.5.10.2.1.1 | OneBasedIndex | read-only | This attribute defines the index (one based) of the physdisk. |
| INT physdiskDeviceId | 1.3.6.1.4.1.21865.1.5.10.2.1.2 | INTEGER | read-only | The unique Device ID of the physical disk. |
| STR physdiskDescription | 1.3.6.1.4.1.21865.1.5.10.2.1.3 | DisplayString | read-only | The Description for the physical disk. |
| STR physdiskStatusString | 1.3.6.1.4.1.21865.1.5.10.2.1.4 | DisplayString | read-only | The StatusString for the physical disk. |
| INT physdiskStatus | 1.3.6.1.4.1.21865.1.5.10.2.1.5 | INTEGER | read-only | The Status of the physical disk. |
| STR physdiskModel | 1.3.6.1.4.1.21865.1.5.10.2.1.6 | DisplayString | read-only | The Model of the physical disk. |
| STR physdiskSerialNum | 1.3.6.1.4.1.21865.1.5.10.2.1.7 | DisplayString | read-only | The Serial Number of the physical disk. |
| STR physdiskFirmware | 1.3.6.1.4.1.21865.1.5.10.2.1.8 | DisplayString | read-only | The Firmware version of the physical disk. |
| STR physdiskCapacity | 1.3.6.1.4.1.21865.1.5.10.2.1.9 | DisplayString | read-only | The Capacity of the physical disk. |
| INT physdiskPowerOnHours | 1.3.6.1.4.1.21865.1.5.10.2.1.10 | INTEGER | read-only | The Power-On-Hours of the physical disk. |
| INT physdiskPendingSectors | 1.3.6.1.4.1.21865.1.5.10.2.1.11 | INTEGER | read-only | The PendingSectors of the physical disk. |
| INT physdiskReallocSectors | 1.3.6.1.4.1.21865.1.5.10.2.1.12 | INTEGER | read-only | The Reallocated Sectors of the physical disk. |
| INT physdiskSeekError | 1.3.6.1.4.1.21865.1.5.10.2.1.13 | INTEGER | read-only | The Seek Error Rate of the physical disk. |
| volumeGroup | 1.3.6.1.4.1.21865.1.5.20 | |||
| INT volumeProbeInstances | 1.3.6.1.4.1.21865.1.5.20.1 | INTEGER | read-only | This attribute denotes the number of Volume entries available on the system |
| volumeProbeTable | 1.3.6.1.4.1.21865.1.5.20.2 | not-accessible | This object defines the Volume Probe Table. | |
| volumeProbeTableEntry | 1.3.6.1.4.1.21865.1.5.20.2.1 | not-accessible | This object defines the Volume Probe Table Entry. | |
| ONE volumeIndex | 1.3.6.1.4.1.21865.1.5.20.2.1.1 | OneBasedIndex | read-only | This attribute defines the index (one based) of the volume. |
| INT volumeDeviceId | 1.3.6.1.4.1.21865.1.5.20.2.1.2 | INTEGER | read-only | This attribute defines the unique Device ID of the volume. |
| STR volumeDescription | 1.3.6.1.4.1.21865.1.5.20.2.1.3 | DisplayString | read-only | The Description for the volume. |
| STR volumeStatusString | 1.3.6.1.4.1.21865.1.5.20.2.1.4 | DisplayString | read-only | The Status String for the volume. |
| INT volumeStatus | 1.3.6.1.4.1.21865.1.5.20.2.1.5 | INTEGER | read-only | This attribute defines the Status of the volume. |
| mgtGroup | 1.3.6.1.4.1.21865.1.6 | |||
| STR mgtInfoAssetId | 1.3.6.1.4.1.21865.1.6.1 | DisplayString | read-only | This attribute defines the Unitrends Asset ID of the system. |
| STR mgtInfoHostname | 1.3.6.1.4.1.21865.1.6.2 | DisplayString | read-only | This attribute defines the Hostname of the system. |
| STR mgtInfoKernelVersion | 1.3.6.1.4.1.21865.1.6.3 | DisplayString | read-only | This attribute defines the Linux Kernel version of the system. |
| STR mgtInfoMemoryTotal | 1.3.6.1.4.1.21865.1.6.4 | DisplayString | read-only | This attribute defines Total Memory (MB) on the system. |
| STR mgtInfoMemoryUsed | 1.3.6.1.4.1.21865.1.6.5 | DisplayString | read-only | This attribute defines Memory Used (MB) on the system. |
| STR mgtInfoMemoryFree | 1.3.6.1.4.1.21865.1.6.6 | DisplayString | read-only | This attribute defines Memory Free (MB) on the system. |
| STR mgtInfoCpuUsed | 1.3.6.1.4.1.21865.1.6.7 | DisplayString | read-only | This attribute defines the percentage of CPU used. |
| STR mgtInfoBaseboard | 1.3.6.1.4.1.21865.1.6.8 | DisplayString | read-only | This attribute defines the system baseboard model. |
| STR mgtInfoBiosVersion | 1.3.6.1.4.1.21865.1.6.9 | DisplayString | read-only | This attribute defines the BIOS version on the system. |
| STR mgtInfoFwVersion | 1.3.6.1.4.1.21865.1.6.10 | DisplayString | read-only | This attribute defines the Firmware version on the system. |
| STR mgtInfoDhcpMode | 1.3.6.1.4.1.21865.1.6.11 | DisplayString | read-only | This attribute defines the DHCP Mode of the IPMI LAN interface. |
| STR mgtInfoIpAddress | 1.3.6.1.4.1.21865.1.6.12 | DisplayString | read-only | This attribute defines the IP Address of the IPMI LAN interface. |
| STR mgtInfoMacAddress | 1.3.6.1.4.1.21865.1.6.13 | DisplayString | read-only | This attribute defines the MAC Address of the IPMI LAN interface. |
| STR mgtInfoSubnetMask | 1.3.6.1.4.1.21865.1.6.14 | DisplayString | read-only | This attribute defines the Subnet Mask of the IPMI LAN interface. |
| STR mgtInfoGatewayIP | 1.3.6.1.4.1.21865.1.6.15 | DisplayString | read-only | This attribute defines the Gateway IP Address of the IPMI LAN interface. |
| STR mgtInfoGatewayMac | 1.3.6.1.4.1.21865.1.6.16 | DisplayString | read-only | This attribute defines the Gateway MAC Address of the IPMI LAN interface. |
| STR mgtInfoLanPort | 1.3.6.1.4.1.21865.1.6.17 | DisplayString | read-only | This attribute defines the IPMI LAN interface port used. |
| STR mgtInfoManufDate | 1.3.6.1.4.1.21865.1.6.18 | DisplayString | read-only | This attribute defines the IPMI Manufacturing Date of the baseboard. |
| STR mgtInfoRelease | 1.3.6.1.4.1.21865.1.6.19 | DisplayString | read-only | This attribute defines the Unitrends release version. |
RFC description
Monitors Unitrends Rapid Recovery backup appliances, including backup status, hardware health, and event notifications.
Start monitoring Unitrends Rapid Recovery backup appliances (CPU/memory/voltage-rail health status) with a free 30-day trial of IPNetwork Monitor. Import MIBs, browse SNMP OIDs, create custom SNMP monitors, configure alerts, and monitor any SNMP-enabled network device from a single console.