TIMETRA-SAS-SYSTEM-MIB :: tmnxPtpTimeUsePtp

MIB Reference — IPNetwork Monitor · Updated October 06, 2026

All MIBs › TIMETRA-SAS-SYSTEM-MIB › tmnxPtpTimeUsePtp

tmnxPtpTimeUsePtp

Module: TIMETRA-SAS-SYSTEM-MIB

OID (symbolic): TIMETRA-SAS-SYSTEM-MIB::tmnxPtpTimeUsePtp

OID (numeric): 1.3.6.1.4.1.6527.6.2.2.2.5.21.1

Node type: OBJECT-TYPE

Type: TmnxPtpTime

Access: read-write

Description: If this object is configured with 'system', ptp derived time (in UTC timescale) is used for all the system applications that need time, including the timestamps needed for OAM tools. If configured with 'oam', the system will use the PTP derived time (in UTC timescale) for only the timestamps needed by OAM. By default NTP derived time is used for all system applications. If NTP is not configured, then the system RTC is used for obtaining timestmaps in UTC timescale for all system applications

What is tmnxPtpTimeUsePtp?

Controls which time source is used for system timestamps: 'system' uses PTP-derived UTC time for all applications including OAM, 'oam' uses PTP time only for OAM timestamps, and the default (no PTP) falls back to NTP-derived time, or the system RTC if NTP isn't configured. Admins set this to 'system' or 'oam' on deployments needing PTP's higher timestamp precision for OAM tools, rather than relying on NTP's typically looser accuracy.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.6527.6.2.2.2.5.21.1
snmpwalk -v2c -c public <target> TIMETRA-SAS-SYSTEM-MIB::tmnxPtpTimeUsePtp

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.6527.6.2.2.2.5.21.1.1
snmpget -v2c -c public <target> TIMETRA-SAS-SYSTEM-MIB::tmnxPtpTimeUsePtp.1

Set instance 1 (SNMPv2c):

snmpset -v2c -c private <target> 1.3.6.1.4.1.6527.6.2.2.2.5.21.1.1 s <value>

Start monitoring Nokia/Alcatel-Lucent 7210 SAS Service Access Switch (dual-uplink redundancy/keepalive status) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the TIMETRA-SAS-SYSTEM-MIB::tmnxPtpTimeUsePtp OID value, configure state conditions and alerts, and monitor any Nokia/Alcatel-Lucent 7210 SAS Service Access Switch (dual-uplink redundancy/keepalive status) from a single console.

OID Breakdown

Upper-level ancestors (11 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.6527timetraALCATEL-IND1-TIMETRA-GLOBAL-MIB
1.3.6.1.4.1.6527.6tmnxBasedProductsTIMETRA-GLOBAL-MIB
1.3.6.1.4.1.6527.6.2timetraServiceAccessSwitchesTIMETRA-SAS-GLOBAL-MIB
1.3.6.1.4.1.6527.6.2.2timetraSASMIBTIMETRA-SAS-GLOBAL-MIB
1.3.6.1.4.1.6527.6.2.2.2timetraSASObjsTIMETRA-SAS-GLOBAL-MIB
Numeric OIDNameModule
1.3.6.1.4.1.6527.6.2.2.2.5tmnxSASSysObjsTIMETRA-SAS-SYSTEM-MIB
1.3.6.1.4.1.6527.6.2.2.2.5.21sysClockInfoTIMETRA-SAS-SYSTEM-MIB
1.3.6.1.4.1.6527.6.2.2.2.5.21.1tmnxPtpTimeUsePtpTIMETRA-SAS-SYSTEM-MIB