All MIBs › TIMETRA-SAS-SYSTEM-MIB › tmnxHwLowTempThreshold
tmnxHwLowTempThreshold
Module: TIMETRA-SAS-SYSTEM-MIB
OID (symbolic): TIMETRA-SAS-SYSTEM-MIB::tmnxHwLowTempThreshold
OID (numeric): 1.3.6.1.4.1.6527.6.2.2.2.6.4.1.1
Node type: OBJECT-TYPE
Type: Integer32
Access: read-only
Description: The low temperature threshold for this hardware component in degrees celsius. When the value of tmnxHwTemperature lowers below tmnxHwLowTempThreshold, a 'temperature too low' event will be generated.
What is tmnxHwLowTempThreshold?
The low-temperature threshold, in degrees Celsius, for this hardware component; a 'temperature too low' event is generated once the component's measured temperature drops below this value. Admins use this read-only value to know at what point cold-weather conditions will trigger an alarm on this specific piece of hardware.
Examples
Walk all instances (SNMPv2c):
snmpwalk -v2c -c public <target> 1.3.6.1.4.1.6527.6.2.2.2.6.4.1.1 snmpwalk -v2c -c public <target> TIMETRA-SAS-SYSTEM-MIB::tmnxHwLowTempThreshold
Get a specific instance (index 1):
snmpget -v2c -c public <target> 1.3.6.1.4.1.6527.6.2.2.2.6.4.1.1.1 snmpget -v2c -c public <target> TIMETRA-SAS-SYSTEM-MIB::tmnxHwLowTempThreshold.1
Start monitoring Nokia/Alcatel-Lucent 7210 SAS Service Access Switch (dual-uplink redundancy/keepalive status) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the TIMETRA-SAS-SYSTEM-MIB::tmnxHwLowTempThreshold OID value, configure state conditions and alerts, and monitor any Nokia/Alcatel-Lucent 7210 SAS Service Access Switch (dual-uplink redundancy/keepalive status) from a single console.
OID Breakdown
Upper-level ancestors (11 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.4 | private | AirPair-MIB |
| 1.3.6.1.4.1 | enterprises | AirPair-MIB |
| 1.3.6.1.4.1.6527 | timetra | ALCATEL-IND1-TIMETRA-GLOBAL-MIB |
| 1.3.6.1.4.1.6527.6 | tmnxBasedProducts | TIMETRA-GLOBAL-MIB |
| 1.3.6.1.4.1.6527.6.2 | timetraServiceAccessSwitches | TIMETRA-SAS-GLOBAL-MIB |
| 1.3.6.1.4.1.6527.6.2.2 | timetraSASMIB | TIMETRA-SAS-GLOBAL-MIB |
| 1.3.6.1.4.1.6527.6.2.2.2 | timetraSASObjs | TIMETRA-SAS-GLOBAL-MIB |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.6527.6.2.2.2.6 | tmnxSASChassisObjs | TIMETRA-SAS-SYSTEM-MIB |
| 1.3.6.1.4.1.6527.6.2.2.2.6.4 | tmnxHwExtnTable | TIMETRA-SAS-SYSTEM-MIB |
| 1.3.6.1.4.1.6527.6.2.2.2.6.4.1 | tmnxHwExtnEntry | TIMETRA-SAS-SYSTEM-MIB |
| 1.3.6.1.4.1.6527.6.2.2.2.6.4.1.1 | tmnxHwLowTempThreshold | TIMETRA-SAS-SYSTEM-MIB |