TIMETRA-SAS-SYSTEM-MIB :: tmnxChassisPowerSupplyAssignedDCType

MIB Reference — IPNetwork Monitor · Updated October 06, 2026

All MIBs › TIMETRA-SAS-SYSTEM-MIB › tmnxChassisPowerSupplyAssignedDCType

tmnxChassisPowerSupplyAssignedDCType

Module: TIMETRA-SAS-SYSTEM-MIB

OID (symbolic): TIMETRA-SAS-SYSTEM-MIB::tmnxChassisPowerSupplyAssignedDCType

OID (numeric): 1.3.6.1.4.1.6527.6.2.2.2.6.6.1.1

Node type: OBJECT-TYPE

Type: INTEGER

Access: read-only

Description: tmnxChassisPowerSupplyAssignedDCType when set to `m48-dc`, the power supply is -48V DC, when set to P24-dc it is +24V DC. tmnxChassisPowerSupplyAssignedDCType is set to m48-dc or p24-dc if tmnxChassisPowerSupplyAssignedType is of type `dc`, If tmnxChassisPowerSupplyAssignedType is not `dc` tmnxChassisPowerSupplyAssignedDCType will be set to not-applicable.

What is tmnxChassisPowerSupplyAssignedDCType?

The DC voltage type assigned to this power supply: m48-dc(1) for -48V DC, p24-dc(2) for +24V DC, not-applicable(0) if the supply isn't DC-type, or unknown(3). Admins check this to confirm a DC power supply is provisioned with the correct voltage type expected by the site's power plant, since mismatches can prevent the supply from being recognized correctly.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.6527.6.2.2.2.6.6.1.1
snmpwalk -v2c -c public <target> TIMETRA-SAS-SYSTEM-MIB::tmnxChassisPowerSupplyAssignedDCType

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.6527.6.2.2.2.6.6.1.1.1
snmpget -v2c -c public <target> TIMETRA-SAS-SYSTEM-MIB::tmnxChassisPowerSupplyAssignedDCType.1

Start monitoring Nokia/Alcatel-Lucent 7210 SAS Service Access Switch (dual-uplink redundancy/keepalive status) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the TIMETRA-SAS-SYSTEM-MIB::tmnxChassisPowerSupplyAssignedDCType OID value, configure state conditions and alerts, and monitor any Nokia/Alcatel-Lucent 7210 SAS Service Access Switch (dual-uplink redundancy/keepalive status) from a single console.

OID Breakdown

Upper-level ancestors (11 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.6527timetraALCATEL-IND1-TIMETRA-GLOBAL-MIB
1.3.6.1.4.1.6527.6tmnxBasedProductsTIMETRA-GLOBAL-MIB
1.3.6.1.4.1.6527.6.2timetraServiceAccessSwitchesTIMETRA-SAS-GLOBAL-MIB
1.3.6.1.4.1.6527.6.2.2timetraSASMIBTIMETRA-SAS-GLOBAL-MIB
1.3.6.1.4.1.6527.6.2.2.2timetraSASObjsTIMETRA-SAS-GLOBAL-MIB
Numeric OIDNameModule
1.3.6.1.4.1.6527.6.2.2.2.6tmnxSASChassisObjsTIMETRA-SAS-SYSTEM-MIB
1.3.6.1.4.1.6527.6.2.2.2.6.6tmnxChassisPowerSupplyExtnTableTIMETRA-SAS-SYSTEM-MIB
1.3.6.1.4.1.6527.6.2.2.2.6.6.1tmnxChassisPowerSupplyExtnEntryTIMETRA-SAS-SYSTEM-MIB
1.3.6.1.4.1.6527.6.2.2.2.6.6.1.1tmnxChassisPowerSupplyAssignedDCTypeTIMETRA-SAS-SYSTEM-MIB