TIMETRA-SAS-SYSTEM-MIB :: sysOperGrpNumMembers

MIB Reference — IPNetwork Monitor · Updated October 06, 2026

All MIBs › TIMETRA-SAS-SYSTEM-MIB › sysOperGrpNumMembers

sysOperGrpNumMembers

Module: TIMETRA-SAS-SYSTEM-MIB

OID (symbolic): TIMETRA-SAS-SYSTEM-MIB::sysOperGrpNumMembers

OID (numeric): 1.3.6.1.4.1.6527.6.2.2.2.5.24.2.1.10

Node type: OBJECT-TYPE

Type: Gauge32

Access: read-only

Description: The value of sysOperGrpNumMembers indicates the number of members as part of this operational-group.

What is sysOperGrpNumMembers?

The number of member objects currently part of this operational group. Admins check this to confirm the expected number of tracked members (e.g. links or ports) are actually associated with the group.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.6527.6.2.2.2.5.24.2.1.10
snmpwalk -v2c -c public <target> TIMETRA-SAS-SYSTEM-MIB::sysOperGrpNumMembers

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.6527.6.2.2.2.5.24.2.1.10.1
snmpget -v2c -c public <target> TIMETRA-SAS-SYSTEM-MIB::sysOperGrpNumMembers.1

Start monitoring Nokia/Alcatel-Lucent 7210 SAS Service Access Switch (dual-uplink redundancy/keepalive status) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the TIMETRA-SAS-SYSTEM-MIB::sysOperGrpNumMembers OID value, configure state conditions and alerts, and monitor any Nokia/Alcatel-Lucent 7210 SAS Service Access Switch (dual-uplink redundancy/keepalive status) from a single console.

How to Use in IPNetwork Monitor

Select a Nokia/Alcatel-Lucent 7210 SAS Service Access Switch (dual-uplink redundancy/keepalive status) as the target host to create a monitor — the SNMP service should be up and running on it. Click New Monitor, then check SNMP Custom on the Favorites tab, click Next, and confirm the host. On the next page, click Select... to open the built-in SNMP MIB Browser and type sysOperGrpNumMembers into the Find box to locate it in the OID tree, selecting the specific row/instance you want to monitor since this is a table column, then select it and click OK. The value of sysOperGrpNumMembers indicates the number of members as part of this operational-group. On the monitor's Main parameters page you can set the target's SNMP port (default 161), credentials, polling interval, and other settings — see the SNMP Monitor help for details. On the State conditions and Alerting tabs, configure when the monitor should change state and trigger an alert; since this is a Gauge32-type OID, Value bounds is the most useful condition here — trigger an alert if the counter increases sharply between polls relative to its normal baseline, since an unexpected spike often reflects a real change in traffic or activity. Click Finish to create the monitor; you can adjust any parameter later.

OID Breakdown

Upper-level ancestors (11 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.6527timetraALCATEL-IND1-TIMETRA-GLOBAL-MIB
1.3.6.1.4.1.6527.6tmnxBasedProductsTIMETRA-GLOBAL-MIB
1.3.6.1.4.1.6527.6.2timetraServiceAccessSwitchesTIMETRA-SAS-GLOBAL-MIB
1.3.6.1.4.1.6527.6.2.2timetraSASMIBTIMETRA-SAS-GLOBAL-MIB
1.3.6.1.4.1.6527.6.2.2.2timetraSASObjsTIMETRA-SAS-GLOBAL-MIB
Numeric OIDNameModule
1.3.6.1.4.1.6527.6.2.2.2.5tmnxSASSysObjsTIMETRA-SAS-SYSTEM-MIB
1.3.6.1.4.1.6527.6.2.2.2.5.24sysOperGrpObjsTIMETRA-SAS-SYSTEM-MIB
1.3.6.1.4.1.6527.6.2.2.2.5.24.2sysOperGrpTableTIMETRA-SAS-SYSTEM-MIB
1.3.6.1.4.1.6527.6.2.2.2.5.24.2.1sysOperGrpEntryTIMETRA-SAS-SYSTEM-MIB
1.3.6.1.4.1.6527.6.2.2.2.5.24.2.1.10sysOperGrpNumMembersTIMETRA-SAS-SYSTEM-MIB