All MIBs › TIMETRA-OES-MIB › tmnxOesDbSyncFailure
tmnxOesDbSyncFailure
Module: TIMETRA-OES-MIB
OID (symbolic): TIMETRA-OES-MIB::tmnxOesDbSyncFailure
OID (numeric): 1.3.6.1.4.1.6527.3.1.3.98.0.3
Node type: NOTIFICATION-TYPE
Description: The active Equipment Controller is unable to synchronize its database with the inactive Equipment Controller.
[CAUSE] The tmnxOesDbSyncFailure notification may be raised under the following conditions: 1) An incorrectly seated Equipment Controller; 2) The software versions on the active and inactive Equipment Controllers are not compatible; 3) A hardware problem with one or both controllers.
[EFFECT] The OES does not have redundancy protection between the two Equipment Controller cards.
[RECOVERY] Proceed as follows to clear the Database Synchronization Failed alarm: 1) Remove the Equipment Controller with the condition and examine the connector on the back of the card for damage, including bent or broken pins; 2) Examine the connector on the backplane for damage. If there is damage to the backplane of the shelf, contact your service representative; 3) Re-insert the Equipment Controller into its original slot and allow the card to initialize; 4) Repeat Step 2) through Step 4) for the second Equipment Controller; 5) Replace the Equipment Controller with the alarm condition with a new unit. If the condition is not cleared, replace the second Equipment Controller with a new unit. Follow the return and repair process to return the faulty card to an authorized repair center for replacement.
Examples
Send this trap to an SNMP manager — replace <manager> with the IP or hostname of your monitoring server (SNMPv2c):
snmptrap -v2c -c public <manager> '' TIMETRA-OES-MIB::tmnxOesDbSyncFailure snmptrap -v2c -c public <manager> '' 1.3.6.1.4.1.6527.3.1.3.98.0.3
Listen for incoming traps on the manager host (-f keeps it in the foreground, -Lo prints to stdout — useful for testing):
snmptrapd -f -Lo -c /dev/null authCommunity log public
Example snmptrapd log entry:
zoo11-linux.zoo [UDP: [192.168.30.111]:59350->[192.168.30.10]:162]: DISMAN-EVENT-MIB::sysUpTimeInstance = Timeticks: (213714902) 24 days, 17:39:09.02 SNMPv2-MIB::snmpTrapOID.0 = OID: TIMETRA-OES-MIB::tmnxOesDbSyncFailure
Start monitoring Nokia 7750 SR chassis with Optical Extension Shelf (OES control-link/firmware status) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the TIMETRA-OES-MIB::tmnxOesDbSyncFailure OID value, configure state conditions and alerts, and monitor any Nokia 7750 SR chassis with Optical Extension Shelf (OES control-link/firmware status) from a single console.
OID Breakdown
Upper-level ancestors (10 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.4 | private | AirPair-MIB |
| 1.3.6.1.4.1 | enterprises | AirPair-MIB |
| 1.3.6.1.4.1.6527 | timetra | ALCATEL-IND1-TIMETRA-GLOBAL-MIB |
| 1.3.6.1.4.1.6527.3 | timetraProducts | ALCATEL-IND1-TIMETRA-GLOBAL-MIB |
| 1.3.6.1.4.1.6527.3.1 | tmnxSRMIB | ALCATEL-IND1-TIMETRA-GLOBAL-MIB |
| 1.3.6.1.4.1.6527.3.1.3 | tmnxSRNotifyPrefix | ALCATEL-IND1-TIMETRA-GLOBAL-MIB |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.6527.3.1.3.98 | tmnxOesMIBNotifyPrefix | TIMETRA-OES-MIB |
| 1.3.6.1.4.1.6527.3.1.3.98.0 | tmnxOesNotifications | TIMETRA-OES-MIB |
| 1.3.6.1.4.1.6527.3.1.3.98.0.3 | tmnxOesDbSyncFailure | TIMETRA-OES-MIB |