tmnxOesDbSyncFailure

Module: TIMETRA-OES-MIB

OID (symbolic): TIMETRA-OES-MIB::tmnxOesDbSyncFailure

OID (numeric): 1.3.6.1.4.1.6527.3.1.3.98.0.3

Node type: NOTIFICATION-TYPE

Description: The active Equipment Controller is unable to synchronize its database with the inactive Equipment Controller.

[CAUSE] The tmnxOesDbSyncFailure notification may be raised under the following conditions: 1) An incorrectly seated Equipment Controller; 2) The software versions on the active and inactive Equipment Controllers are not compatible; 3) A hardware problem with one or both controllers.

[EFFECT] The OES does not have redundancy protection between the two Equipment Controller cards.

[RECOVERY] Proceed as follows to clear the Database Synchronization Failed alarm: 1) Remove the Equipment Controller with the condition and examine the connector on the back of the card for damage, including bent or broken pins; 2) Examine the connector on the backplane for damage. If there is damage to the backplane of the shelf, contact your service representative; 3) Re-insert the Equipment Controller into its original slot and allow the card to initialize; 4) Repeat Step 2) through Step 4) for the second Equipment Controller; 5) Replace the Equipment Controller with the alarm condition with a new unit. If the condition is not cleared, replace the second Equipment Controller with a new unit. Follow the return and repair process to return the faulty card to an authorized repair center for replacement.

Examples

Send this trap to an SNMP manager — replace <manager> with the IP or hostname of your monitoring server (SNMPv2c):

snmptrap -v2c -c public <manager> '' TIMETRA-OES-MIB::tmnxOesDbSyncFailure
snmptrap -v2c -c public <manager> '' 1.3.6.1.4.1.6527.3.1.3.98.0.3

Listen for incoming traps on the manager host (-f keeps it in the foreground, -Lo prints to stdout — useful for testing):

snmptrapd -f -Lo -c /dev/null authCommunity log public

Example snmptrapd log entry:

zoo11-linux.zoo [UDP: [192.168.30.111]:59350->[192.168.30.10]:162]:
  DISMAN-EVENT-MIB::sysUpTimeInstance = Timeticks: (213714902) 24 days, 17:39:09.02
  SNMPv2-MIB::snmpTrapOID.0 = OID: TIMETRA-OES-MIB::tmnxOesDbSyncFailure

Start monitoring Nokia 7750 SR chassis with Optical Extension Shelf (OES control-link/firmware status) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the TIMETRA-OES-MIB::tmnxOesDbSyncFailure OID value, configure state conditions and alerts, and monitor any Nokia 7750 SR chassis with Optical Extension Shelf (OES control-link/firmware status) from a single console.

OID Breakdown

Upper-level ancestors (10 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.6527timetraALCATEL-IND1-TIMETRA-GLOBAL-MIB
1.3.6.1.4.1.6527.3timetraProductsALCATEL-IND1-TIMETRA-GLOBAL-MIB
1.3.6.1.4.1.6527.3.1tmnxSRMIBALCATEL-IND1-TIMETRA-GLOBAL-MIB
1.3.6.1.4.1.6527.3.1.3tmnxSRNotifyPrefixALCATEL-IND1-TIMETRA-GLOBAL-MIB
Numeric OIDNameModule
1.3.6.1.4.1.6527.3.1.3.98tmnxOesMIBNotifyPrefixTIMETRA-OES-MIB
1.3.6.1.4.1.6527.3.1.3.98.0tmnxOesNotificationsTIMETRA-OES-MIB
1.3.6.1.4.1.6527.3.1.3.98.0.3tmnxOesDbSyncFailureTIMETRA-OES-MIB