All MIBs › TIMETRA-OES-MIB › tmnxOesDbInvalid
tmnxOesDbInvalid
Module: TIMETRA-OES-MIB
OID (symbolic): TIMETRA-OES-MIB::tmnxOesDbInvalid
OID (numeric): 1.3.6.1.4.1.6527.3.1.3.98.0.5
Node type: NOTIFICATION-TYPE
Description: [CAUSE] The tmnxOesDbInvalid notification may be raised under the following conditions: 1) During initial installation, if the OES is not properly commissioned; 2) The serial number in the database does not match that of the OES either because the controller was replaced or the alarm card was replaced; 3) A downgrade of OES software has occurred; 4) Equipment Controller is removed/reseated during a system process, causing file corruption; 5) The database audit failed indicating some type of corruption of the database.
[EFFECT] The OES is not in a normal operating mode. It does not have the correct configuration and the state of its cards is unpredictable. As a result, the OES will not boot normally and not all commands are allowed.
[RECOVERY] A database corruption on the OES requires that the OES be re-commissioned. The correct database is held in the host system so it will be restored to the shelf once the existing database is cleared and the host re-establishes communication with the OES.
Examples
Send this trap to an SNMP manager — replace <manager> with the IP or hostname of your monitoring server (SNMPv2c):
snmptrap -v2c -c public <manager> '' TIMETRA-OES-MIB::tmnxOesDbInvalid snmptrap -v2c -c public <manager> '' 1.3.6.1.4.1.6527.3.1.3.98.0.5
Listen for incoming traps on the manager host (-f keeps it in the foreground, -Lo prints to stdout — useful for testing):
snmptrapd -f -Lo -c /dev/null authCommunity log public
Example snmptrapd log entry:
zoo11-linux.zoo [UDP: [192.168.30.111]:49891->[192.168.30.10]:162]: DISMAN-EVENT-MIB::sysUpTimeInstance = Timeticks: (352194787) 40 days, 18:19:07.87 SNMPv2-MIB::snmpTrapOID.0 = OID: TIMETRA-OES-MIB::tmnxOesDbInvalid
Start monitoring Nokia 7750 SR chassis with Optical Extension Shelf (OES control-link/firmware status) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the TIMETRA-OES-MIB::tmnxOesDbInvalid OID value, configure state conditions and alerts, and monitor any Nokia 7750 SR chassis with Optical Extension Shelf (OES control-link/firmware status) from a single console.
OID Breakdown
Upper-level ancestors (10 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.4 | private | AirPair-MIB |
| 1.3.6.1.4.1 | enterprises | AirPair-MIB |
| 1.3.6.1.4.1.6527 | timetra | ALCATEL-IND1-TIMETRA-GLOBAL-MIB |
| 1.3.6.1.4.1.6527.3 | timetraProducts | ALCATEL-IND1-TIMETRA-GLOBAL-MIB |
| 1.3.6.1.4.1.6527.3.1 | tmnxSRMIB | ALCATEL-IND1-TIMETRA-GLOBAL-MIB |
| 1.3.6.1.4.1.6527.3.1.3 | tmnxSRNotifyPrefix | ALCATEL-IND1-TIMETRA-GLOBAL-MIB |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.6527.3.1.3.98 | tmnxOesMIBNotifyPrefix | TIMETRA-OES-MIB |
| 1.3.6.1.4.1.6527.3.1.3.98.0 | tmnxOesNotifications | TIMETRA-OES-MIB |
| 1.3.6.1.4.1.6527.3.1.3.98.0.5 | tmnxOesDbInvalid | TIMETRA-OES-MIB |