All MIBs › TIMETRA-OES-MIB › tmnxOesCtlCommsDownReason
tmnxOesCtlCommsDownReason
Module: TIMETRA-OES-MIB
OID (symbolic): TIMETRA-OES-MIB::tmnxOesCtlCommsDownReason
OID (numeric): 1.3.6.1.4.1.6527.3.1.2.98.2.7
Node type: OBJECT-TYPE
Type: INTEGER
Access: read-only
Description: The value of tmnxOesCtlCommsDownReason indicates the reason for the last time a loss of communication with the OES was detected.
Values: unknownReason (0) - control communication failure for unknown reason adminReboot (1) - OES is rebooted via tmnxOesReboot noResponse (2) - no response was received for SNMP packet configFailed (3) - a SNMP SET, GET or GETNEXT during a configuration action did not complete correctly invalidSystem (4) - the OES sysObjectID does not contain the object identifier for a supported system invalidSoftware (5) - the OES software version is below the minimum supported version oesUnreachable (6) - OES is unreachable adminEcSwitchOver (7) - OES EC activity switch via tmnxOesChassisActivitySwitch ctlCommsUnprov (8) - missing or incomplete OES control communications provisioning clearActiveEcCard (9) - OES active EC clear via tmnxOesCardReboot
What is tmnxOesCtlCommsDownReason?
Reports the reason for the last detected loss of OES control communication, such as adminReboot(1), noResponse(2), configFailed(3), invalidSystem(4), invalidSoftware(5), oesUnreachable(6), adminEcSwitchOver(7), ctlCommsUnprov(8), or clearActiveEcCard(9). An admin reads this after a comms outage to quickly identify whether it was an intentional action (like a reboot) or an actual fault condition.
Examples
Walk all instances (SNMPv2c):
snmpwalk -v2c -c public <target> 1.3.6.1.4.1.6527.3.1.2.98.2.7 snmpwalk -v2c -c public <target> TIMETRA-OES-MIB::tmnxOesCtlCommsDownReason
Get a specific instance (index 1):
snmpget -v2c -c public <target> 1.3.6.1.4.1.6527.3.1.2.98.2.7.1 snmpget -v2c -c public <target> TIMETRA-OES-MIB::tmnxOesCtlCommsDownReason.1
Start monitoring Nokia 7750 SR chassis with Optical Extension Shelf (OES control-link/firmware status) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the TIMETRA-OES-MIB::tmnxOesCtlCommsDownReason OID value, configure state conditions and alerts, and monitor any Nokia 7750 SR chassis with Optical Extension Shelf (OES control-link/firmware status) from a single console.
OID Breakdown
Upper-level ancestors (10 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.4 | private | AirPair-MIB |
| 1.3.6.1.4.1 | enterprises | AirPair-MIB |
| 1.3.6.1.4.1.6527 | timetra | ALCATEL-IND1-TIMETRA-GLOBAL-MIB |
| 1.3.6.1.4.1.6527.3 | timetraProducts | ALCATEL-IND1-TIMETRA-GLOBAL-MIB |
| 1.3.6.1.4.1.6527.3.1 | tmnxSRMIB | ALCATEL-IND1-TIMETRA-GLOBAL-MIB |
| 1.3.6.1.4.1.6527.3.1.2 | tmnxSRObjs | ALCATEL-IND1-TIMETRA-GLOBAL-MIB |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.6527.3.1.2.98 | tmnxOesObjs | TIMETRA-OES-MIB |
| 1.3.6.1.4.1.6527.3.1.2.98.2 | tmnxOesStatObjs | TIMETRA-OES-MIB |
| 1.3.6.1.4.1.6527.3.1.2.98.2.7 | tmnxOesCtlCommsDownReason | TIMETRA-OES-MIB |