All MIBs › TELDAT-TRAP-SL-MIB
Organization: Teldat, S.A.
Last Updated: 2014-01-20
Category: Remote Access and Serial WAN, Teldat Router Management, Teldat Trap Notifications
Description: Defines Teldat router SL (serial line) interface event trap notifications.
Start monitoring vendor-neutral, standards-based MIB, any SNMPv3-capable network device (SNMP engine identity/boot/clock status) with a free 30-day trial of IPNetwork Monitor. Import MIBs, browse SNMP OIDs, create custom SNMP monitors, configure alerts, and monitor any SNMP-enabled network device from a single console.
What Is TELDAT-TRAP-SL-MIB?
TELDAT-TRAP-SL-MIB is a Teldat enterprise MIB module that defines SNMP trap notifications generated by the Serial Line (SL) event subsystem on Teldat routers. It exposes no polled runtime tables of its own; instead it defines a family of notification (trap) objects carrying diagnostic variables such as interface identifiers, protocol/opcode fields, and frame length parameters tied to serial-line events. Its primary monitoring value is fault and status detection: it lets a management station learn asynchronously when a serial interface changes state, negotiates a protocol, or reports a length mismatch, which is useful for spotting flapping or misconfigured WAN links. It builds on the standard SNMPv2 notification framework (SNMPv2-TC/SNMPv2-CONF) used across Teldat's TRAP-family MIBs. It is typically deployed alongside core Teldat router MIBs in an NMS trap receiver configured to alert on serial-line faults in branch or WAN-edge routers. Engineers can download the TELDAT-TRAP-SL-MIB file directly to load it into their MIB browser.
IPNetwork Monitor allows you to monitor SNMP objects defined in TELDAT-TRAP-SL-MIB. Use the built-in SNMP Monitoring Browser to explore available variables, view their current values and descriptions, and select the objects you want to monitor. You can then create SNMP monitors, configure thresholds, and receive alerts when monitored values change.
Supported Devices
- Teldat router (serial/WAN interface modules)
Monitoring Examples
The module defines notification objects such as sl1-interface, sl4-actual-length, sl4-claimed-length, sl5-opcode, and sl6-protocol, each carried inside a distinct SL trap (sl1 through sl8) rather than being polled from a table. An administrator's trap receiver would log an sl4 trap showing a mismatch between sl4-actual-length and sl4-claimed-length to flag a corrupted or misframed serial link, or an sl6 trap reporting an unexpected sl6-protocol value on a given sl6-interface to catch a serial-line configuration error. There is no GET-able status table here; all monitoring is event-driven through slNotifications.
What Can Be Monitored
- serial line interface identity per event
- frame length actual vs claimed
- serial line protocol/opcode on state change
- occurrence of SL subsystem fault events
This MIB depends on
Related MIBs
Imported Objects
From SNMPv2-SMI
| Integer32 | |
| IpAddress | |
| MODULE-IDENTITY | |
| NOTIFICATION-TYPE | |
| OBJECT-IDENTITY | |
| OBJECT-TYPE |
From SNMPv2-TC
| DisplayString |
From TELDAT-MIB
| telEventTraps | OBJECT-IDENTITY |
OIDs
| OID symbolic | OID numeric | Type | Access | Description |
|---|---|---|---|---|
| slTrapsMIB | 1.3.6.1.4.1.2007.1.4.83 | This Module Information Base file is defined for managing received SNMP notifications generated by the SL event subsystem. | ||
| slEventsGroup | 1.3.6.1.4.1.2007.1.4.83.1 | |||
| slEventObjects1 | 1.3.6.1.4.1.2007.1.4.83.1.1 | Event SL.1 A packet buffer was not available when the interface self-test needed one. | ||
| STR sl1_interface | 1.3.6.1.4.1.2007.1.4.83.1.1.1 | DisplayString | accessible-for-notify | Parameter 'interface' in event SL.1 |
| slEventObjects2 | 1.3.6.1.4.1.2007.1.4.83.1.2 | Event SL.2 During the self-test, the interface card detected that certain signals from modem necessary to indicate that it is present and ready to operate were not detectable. | ||
| STR sl2_interface | 1.3.6.1.4.1.2007.1.4.83.1.2.1 | DisplayString | accessible-for-notify | Parameter 'interface' in event SL.2 |
| slEventObjects3 | 1.3.6.1.4.1.2007.1.4.83.1.3 | Event SL.3 During self-test, an Echo Acknowledgement was not received from the other end of the line within the timeout period. The network fails self-test. | ||
| STR sl3_interface | 1.3.6.1.4.1.2007.1.4.83.1.3.1 | DisplayString | accessible-for-notify | Parameter 'interface' in event SL.3 |
| slEventObjects4 | 1.3.6.1.4.1.2007.1.4.83.1.4 | Event SL.4 A bad length field or truncated packet was detected in a DECnet packet on the serial line. | ||
| I32 sl4_actual_length | 1.3.6.1.4.1.2007.1.4.83.1.4.1 | Integer32 | accessible-for-notify | Parameter 'actual-length' in event SL.4 |
| I32 sl4_claimed_length | 1.3.6.1.4.1.2007.1.4.83.1.4.2 | Integer32 | accessible-for-notify | Parameter 'claimed-length' in event SL.4 |
| STR sl4_interface | 1.3.6.1.4.1.2007.1.4.83.1.4.3 | DisplayString | accessible-for-notify | Parameter 'interface' in event SL.4 |
| slEventObjects5 | 1.3.6.1.4.1.2007.1.4.83.1.5 | Event SL.5 A network control packet was received with a packet type which did not match any known opcode. | ||
| I32 sl5_opcode | 1.3.6.1.4.1.2007.1.4.83.1.5.1 | Integer32 | accessible-for-notify | Parameter 'opcode' in event SL.5 |
| STR sl5_interface | 1.3.6.1.4.1.2007.1.4.83.1.5.2 | DisplayString | accessible-for-notify | Parameter 'interface' in event SL.5 |
| slEventObjects6 | 1.3.6.1.4.1.2007.1.4.83.1.6 | Event SL.6 A serial line packet was received with a higher level protocol which did not match any known protocol. | ||
| I32 sl6_protocol | 1.3.6.1.4.1.2007.1.4.83.1.6.1 | Integer32 | accessible-for-notify | Parameter 'protocol' in event SL.6 |
| STR sl6_interface | 1.3.6.1.4.1.2007.1.4.83.1.6.2 | DisplayString | accessible-for-notify | Parameter 'interface' in event SL.6 |
| slEventObjects7 | 1.3.6.1.4.1.2007.1.4.83.1.7 | Event SL.7 Self-test is being started on the serial line. | ||
| STR sl7_interface | 1.3.6.1.4.1.2007.1.4.83.1.7.1 | DisplayString | accessible-for-notify | Parameter 'interface' in event SL.7 |
| slEventObjects8 | 1.3.6.1.4.1.2007.1.4.83.1.8 | Event SL.8 An echo request is being sent on the serial line. | ||
| STR sl8_interface | 1.3.6.1.4.1.2007.1.4.83.1.8.1 | DisplayString | accessible-for-notify | Parameter 'interface' in event SL.8 |
| slEventObjects9 | 1.3.6.1.4.1.2007.1.4.83.1.9 | Event SL.9 A test packet has been received on the serial line. | ||
| STR sl9_interface | 1.3.6.1.4.1.2007.1.4.83.1.9.1 | DisplayString | accessible-for-notify | Parameter 'interface' in event SL.9 |
| slEventObjects10 | 1.3.6.1.4.1.2007.1.4.83.1.10 | Event SL.10 An echo acknowledgement packet has been received on the serial line. | ||
| STR sl10_interface | 1.3.6.1.4.1.2007.1.4.83.1.10.1 | DisplayString | accessible-for-notify | Parameter 'interface' in event SL.10 |
| slEventObjects11 | 1.3.6.1.4.1.2007.1.4.83.1.11 | Event SL.11 An echo acknowledgement packet has been received on the serial line. | ||
| STR sl11_interface | 1.3.6.1.4.1.2007.1.4.83.1.11.1 | DisplayString | accessible-for-notify | Parameter 'interface' in event SL.11 |
| slEventObjects12 | 1.3.6.1.4.1.2007.1.4.83.1.12 | Event SL.12 A test packet used for network maintenence is being sent on the serial line. | ||
| STR sl12_interface | 1.3.6.1.4.1.2007.1.4.83.1.12.1 | DisplayString | accessible-for-notify | Parameter 'interface' in event SL.12 |
| slEventObjects13 | 1.3.6.1.4.1.2007.1.4.83.1.13 | Event SL.13 A Bridged packet is received on this serial line interface even though the Spanning Tree Bridging is not enabled on this interface or STB is disabled in the box. | ||
| STR sl13_interface | 1.3.6.1.4.1.2007.1.4.83.1.13.1 | DisplayString | accessible-for-notify | Parameter 'interface' in event SL.13 |
| slEventObjects14 | 1.3.6.1.4.1.2007.1.4.83.1.14 | Event SL.14 Dual Serial Line Interface board firmware download has completed with the status shown. | ||
| I32 sl14_slot_num | 1.3.6.1.4.1.2007.1.4.83.1.14.1 | Integer32 | accessible-for-notify | Parameter 'slot-num' in event SL.14 |
| STR sl14_ld_code | 1.3.6.1.4.1.2007.1.4.83.1.14.2 | DisplayString | accessible-for-notify | Parameter 'ld-code' in event SL.14 |
| slEventObjects15 | 1.3.6.1.4.1.2007.1.4.83.1.15 | Event SL.15 Dual Serial Line Board Power-On Diagnostics status completed with the code shown. See Power-On Diagnostics manual for encoding. | ||
| I32 sl15_slot_num | 1.3.6.1.4.1.2007.1.4.83.1.15.1 | Integer32 | accessible-for-notify | Parameter 'slot-num' in event SL.15 |
| I32 sl15_pud_stat | 1.3.6.1.4.1.2007.1.4.83.1.15.2 | Integer32 | accessible-for-notify | Parameter 'pud-stat' in event SL.15 |
| slEventObjects16 | 1.3.6.1.4.1.2007.1.4.83.1.16 | Event SL.16 Protocol type like Ethertype, DSAPytype or SNAPtype packet filtered. This is due to the user supplied protocol filtering information. (STB). | ||
| STR sl16_protocol_type | 1.3.6.1.4.1.2007.1.4.83.1.16.1 | DisplayString | accessible-for-notify | Parameter 'protocol-type' in event SL.16 |
| I32 sl16_protocol | 1.3.6.1.4.1.2007.1.4.83.1.16.2 | Integer32 | accessible-for-notify | Parameter 'protocol' in event SL.16 |
| STR sl16_interface | 1.3.6.1.4.1.2007.1.4.83.1.16.3 | DisplayString | accessible-for-notify | Parameter 'interface' in event SL.16 |
| slEventObjects17 | 1.3.6.1.4.1.2007.1.4.83.1.17 | Event SL.17 Packet dropped as the protocol type is enabled but packet arrived as bridged. (STB). | ||
| I32 sl17_protocol_type | 1.3.6.1.4.1.2007.1.4.83.1.17.1 | Integer32 | accessible-for-notify | Parameter 'protocol-type' in event SL.17 |
| STR sl17_src_addr | 1.3.6.1.4.1.2007.1.4.83.1.17.2 | DisplayString | accessible-for-notify | Parameter 'src-addr' in event SL.17 |
| STR sl17_interface | 1.3.6.1.4.1.2007.1.4.83.1.17.3 | DisplayString | accessible-for-notify | Parameter 'interface' in event SL.17 |
| slEventObjects18 | 1.3.6.1.4.1.2007.1.4.83.1.18 | Event SL.18 Packet dropped as the protocol filtering applies (STB). | ||
| I32 sl18_protocol_type | 1.3.6.1.4.1.2007.1.4.83.1.18.1 | Integer32 | accessible-for-notify | Parameter 'protocol-type' in event SL.18 |
| STR sl18_interface | 1.3.6.1.4.1.2007.1.4.83.1.18.2 | DisplayString | accessible-for-notify | Parameter 'interface' in event SL.18 |
| slEventObjects19 | 1.3.6.1.4.1.2007.1.4.83.1.19 | Event SL.19 The cable and the level converter on the interface are not compatible with each other. The self-test will fail. | ||
| STR sl19_cable_type | 1.3.6.1.4.1.2007.1.4.83.1.19.1 | DisplayString | accessible-for-notify | Parameter 'cable-type' in event SL.19 |
| STR sl19_level_converter_type | 1.3.6.1.4.1.2007.1.4.83.1.19.2 | DisplayString | accessible-for-notify | Parameter 'level-converter-type' in event SL.19 |
| STR sl19_interface | 1.3.6.1.4.1.2007.1.4.83.1.19.3 | DisplayString | accessible-for-notify | Parameter 'interface' in event SL.19 |
| slEventObjects20 | 1.3.6.1.4.1.2007.1.4.83.1.20 | Event SL.20 There is an incompatibility between the mode of the cable (DCE or DTE) and the type of clocking used. The interface will not be brought up. | ||
| STR sl20_cable_type | 1.3.6.1.4.1.2007.1.4.83.1.20.1 | DisplayString | accessible-for-notify | Parameter 'cable-type' in event SL.20 |
| STR sl20_internal_external | 1.3.6.1.4.1.2007.1.4.83.1.20.2 | DisplayString | accessible-for-notify | Parameter 'internal-external' in event SL.20 |
| STR sl20_interface | 1.3.6.1.4.1.2007.1.4.83.1.20.3 | DisplayString | accessible-for-notify | Parameter 'interface' in event SL.20 |
| slEventObjects21 | 1.3.6.1.4.1.2007.1.4.83.1.21 | Event SL.21 The interface failed self test because at least one of the modem signals was off. | ||
| STR sl21_cts | 1.3.6.1.4.1.2007.1.4.83.1.21.1 | DisplayString | accessible-for-notify | Parameter 'cts' in event SL.21 |
| STR sl21_dsr | 1.3.6.1.4.1.2007.1.4.83.1.21.2 | DisplayString | accessible-for-notify | Parameter 'dsr' in event SL.21 |
| STR sl21_dcd | 1.3.6.1.4.1.2007.1.4.83.1.21.3 | DisplayString | accessible-for-notify | Parameter 'dcd' in event SL.21 |
| STR sl21_interface | 1.3.6.1.4.1.2007.1.4.83.1.21.4 | DisplayString | accessible-for-notify | Parameter 'interface' in event SL.21 |
| slEventObjects22 | 1.3.6.1.4.1.2007.1.4.83.1.22 | Event SL.22 A modem status change has occurred. The present state is described. | ||
| STR sl22_cts | 1.3.6.1.4.1.2007.1.4.83.1.22.1 | DisplayString | accessible-for-notify | Parameter 'cts' in event SL.22 |
| STR sl22_dsr | 1.3.6.1.4.1.2007.1.4.83.1.22.2 | DisplayString | accessible-for-notify | Parameter 'dsr' in event SL.22 |
| STR sl22_dcd | 1.3.6.1.4.1.2007.1.4.83.1.22.3 | DisplayString | accessible-for-notify | Parameter 'dcd' in event SL.22 |
| STR sl22_interface | 1.3.6.1.4.1.2007.1.4.83.1.22.4 | DisplayString | accessible-for-notify | Parameter 'interface' in event SL.22 |
| slEventObjects23 | 1.3.6.1.4.1.2007.1.4.83.1.23 | Event SL.23 The interface was brought down because one of the modem signals was off. | ||
| STR sl23_cts | 1.3.6.1.4.1.2007.1.4.83.1.23.1 | DisplayString | accessible-for-notify | Parameter 'cts' in event SL.23 |
| STR sl23_dsr | 1.3.6.1.4.1.2007.1.4.83.1.23.2 | DisplayString | accessible-for-notify | Parameter 'dsr' in event SL.23 |
| STR sl23_dcd | 1.3.6.1.4.1.2007.1.4.83.1.23.3 | DisplayString | accessible-for-notify | Parameter 'dcd' in event SL.23 |
| STR sl23_interface | 1.3.6.1.4.1.2007.1.4.83.1.23.4 | DisplayString | accessible-for-notify | Parameter 'interface' in event SL.23 |
| slEventObjects24 | 1.3.6.1.4.1.2007.1.4.83.1.24 | Event SL.24 The user-configured frame size for this interface is larger than the maximum that is allowed for the particular serial line device. The size is reduced to the largest allowable one. | ||
| I32 sl24_configured_size | 1.3.6.1.4.1.2007.1.4.83.1.24.1 | Integer32 | accessible-for-notify | Parameter 'configured-size' in event SL.24 |
| I32 sl24_maximum_size | 1.3.6.1.4.1.2007.1.4.83.1.24.2 | Integer32 | accessible-for-notify | Parameter 'maximum-size' in event SL.24 |
| STR sl24_interface | 1.3.6.1.4.1.2007.1.4.83.1.24.3 | DisplayString | accessible-for-notify | Parameter 'interface' in event SL.24 |
| slEventObjects25 | 1.3.6.1.4.1.2007.1.4.83.1.25 | Event SL.25 A bad length field or truncated packet was detected in a SRT bridge packet. | ||
| I32 sl25_actual_length | 1.3.6.1.4.1.2007.1.4.83.1.25.1 | Integer32 | accessible-for-notify | Parameter 'actual-length' in event SL.25 |
| I32 sl25_claimed_length | 1.3.6.1.4.1.2007.1.4.83.1.25.2 | Integer32 | accessible-for-notify | Parameter 'claimed-length' in event SL.25 |
| STR sl25_interface | 1.3.6.1.4.1.2007.1.4.83.1.25.3 | DisplayString | accessible-for-notify | Parameter 'interface' in event SL.25 |
| slEventObjects26 | 1.3.6.1.4.1.2007.1.4.83.1.26 | Event SL.26 An Incoming Serial Line packet is shorter than a minimally required Serial Line header. Such packet can not be processed and hence freed. | ||
| I32 sl26_actual_length | 1.3.6.1.4.1.2007.1.4.83.1.26.1 | Integer32 | accessible-for-notify | Parameter 'actual-length' in event SL.26 |
| STR sl26_interface | 1.3.6.1.4.1.2007.1.4.83.1.26.2 | DisplayString | accessible-for-notify | Parameter 'interface' in event SL.26 |
| slEventObjects27 | 1.3.6.1.4.1.2007.1.4.83.1.27 | Event SL.27 There is no level converter on this port of the Quad Serial Line card. The self-test will fail, and future self-tests will be cancelled. | ||
| STR sl27_interface | 1.3.6.1.4.1.2007.1.4.83.1.27.1 | DisplayString | accessible-for-notify | Parameter 'interface' in event SL.27 |
| slEventObjects28 | 1.3.6.1.4.1.2007.1.4.83.1.28 | Event SL.28 There is a level converter of an unknown type on this port of the Quad Serial Line card. The self-test will fail, and future self-tests will be cancelled. | ||
| I32 sl28_converter_type | 1.3.6.1.4.1.2007.1.4.83.1.28.1 | Integer32 | accessible-for-notify | Parameter 'converter-type' in event SL.28 |
| STR sl28_interface | 1.3.6.1.4.1.2007.1.4.83.1.28.2 | DisplayString | accessible-for-notify | Parameter 'interface' in event SL.28 |
| slEventObjects29 | 1.3.6.1.4.1.2007.1.4.83.1.29 | Event SL.29 The user-configured frame size for this interface is smaller than the minimum that is required for the particular serial line device. The size is increased to the minimum allowable one. | ||
| I32 sl29_configured_size | 1.3.6.1.4.1.2007.1.4.83.1.29.1 | Integer32 | accessible-for-notify | Parameter 'configured-size' in event SL.29 |
| I32 sl29_minimum_size | 1.3.6.1.4.1.2007.1.4.83.1.29.2 | Integer32 | accessible-for-notify | Parameter 'minimum-size' in event SL.29 |
| STR sl29_interface | 1.3.6.1.4.1.2007.1.4.83.1.29.3 | DisplayString | accessible-for-notify | Parameter 'interface' in event SL.29 |
| slEventObjects30 | 1.3.6.1.4.1.2007.1.4.83.1.30 | Event SL.30 The maintenance routine is attempting to send a maintenance frame for Proteon Serial data-link, but the buffer for sending this has not been freed since the previous maintenance. If this happens 3 times in a row, maintenance will fail at the other end of the serial line. | ||
| STR sl30_interface | 1.3.6.1.4.1.2007.1.4.83.1.30.1 | DisplayString | accessible-for-notify | Parameter 'interface' in event SL.30 |
| slEventObjects31 | 1.3.6.1.4.1.2007.1.4.83.1.31 | Event SL.31 A buffer could not be allocated when needed to read the statistics counters from the Dual Serial interface. The counters should be successfully updated at the next maintenance, 4 seconds later. | ||
| STR sl31_interface | 1.3.6.1.4.1.2007.1.4.83.1.31.1 | DisplayString | accessible-for-notify | Parameter 'interface' in event SL.31 |
| slEventObjects32 | 1.3.6.1.4.1.2007.1.4.83.1.32 | Event SL.32 The allocation of a packet buffer for a DNX 300 serial line failed. This may be due to a shortage of either buffer memory or heap memory. (See the output of ELS messages GW.061, GW.063, and GW.064). The interface will still try and come up, but with a reduced number of receive packet buffers. | ||
| I32 sl32_buffer_number | 1.3.6.1.4.1.2007.1.4.83.1.32.1 | Integer32 | accessible-for-notify | Parameter 'buffer-number' in event SL.32 |
| STR sl32_interface | 1.3.6.1.4.1.2007.1.4.83.1.32.2 | DisplayString | accessible-for-notify | Parameter 'interface' in event SL.32 |
| slEventObjects33 | 1.3.6.1.4.1.2007.1.4.83.1.33 | Event SL.33 A packet buffer was allocated for the DNX 300 serial line, but that buffer crossed a 64 Kbyte memory boundary in the buffer memory. Since all of the receive buffers for a DNX 300 serial line must be in the same 64 Kbyte buffer memory packet, that buffer will be ignored, and no further buffers will be allocated for the device. The interface will still try and come up, but with a reduced number of receive packet buffers. | ||
| I32 sl33_buffer_number | 1.3.6.1.4.1.2007.1.4.83.1.33.1 | Integer32 | accessible-for-notify | Parameter 'buffer-number' in event SL.33 |
| STR sl33_interface | 1.3.6.1.4.1.2007.1.4.83.1.33.2 | DisplayString | accessible-for-notify | Parameter 'interface' in event SL.33 |
| slEventObjects34 | 1.3.6.1.4.1.2007.1.4.83.1.34 | Event SL.34 The system does not detect an adapter cable in the network interface port. Self-test will fail. | ||
| STR sl34_interface | 1.3.6.1.4.1.2007.1.4.83.1.34.1 | DisplayString | accessible-for-notify | Parameter 'interface' in event SL.34 |
| slEventObjects35 | 1.3.6.1.4.1.2007.1.4.83.1.35 | Event SL.35 A protocol that cannot be bridged by Proteon Serial Line's PSEUDO- ETHERNET bridging method has been configured over an interface using PSL PSEUDO-ETH. | ||
| STR sl35_protocol_name | 1.3.6.1.4.1.2007.1.4.83.1.35.1 | DisplayString | accessible-for-notify | Parameter 'protocol-name' in event SL.35 |
| I32 sl35_protocol_number | 1.3.6.1.4.1.2007.1.4.83.1.35.2 | Integer32 | accessible-for-notify | Parameter 'protocol-number' in event SL.35 |
| STR sl35_interface | 1.3.6.1.4.1.2007.1.4.83.1.35.3 | DisplayString | accessible-for-notify | Parameter 'interface' in event SL.35 |
| slEventObjects36 | 1.3.6.1.4.1.2007.1.4.83.1.36 | Event SL.36 The interface is on mode loopback or echo and the timeout as expired. | ||
| STR sl36_interface | 1.3.6.1.4.1.2007.1.4.83.1.36.1 | DisplayString | accessible-for-notify | Parameter 'interface' in event SL.36 |
| slNotifications | 1.3.6.1.4.1.2007.1.4.83.2 | |||
| slNotificationsPrefix | 1.3.6.1.4.1.2007.1.4.83.2.0 | |||
| NTF slNotification1 | 1.3.6.1.4.1.2007.1.4.83.2.0.1 | Notification of Event SL.1 Message: 'no buffer available for selftest interface $1' Parameters list: $1: sl1-interface A packet buffer was not available when the interface self-test needed one. | ||
| NTF slNotification2 | 1.3.6.1.4.1.2007.1.4.83.2.0.2 | Notification of Event SL.2 Message: 'modem error with no DCD/DTS detected during selftest interface $1' Parameters list: $1: sl2-interface During the self-test, the interface card detected that certain signals from modem necessary to indicate that it is present and ready to operate were not detectable. | ||
| NTF slNotification3 | 1.3.6.1.4.1.2007.1.4.83.2.0.3 | Notification of Event SL.3 Message: 'no echo acknowledgement received, timeout selftest interface $1' Parameters list: $1: sl3-interface During self-test, an Echo Acknowledgement was not received from the other end of the line within the timeout period. The network fails self-test. | ||
| NTF slNotification4 | 1.3.6.1.4.1.2007.1.4.83.2.0.4 | Notification of Event SL.4 Message: 'bad length in DECNet packet actual $1 claimed $2 interface $3' Parameters list: $1: sl4-actual-length $2: sl4-claimed-length $3: sl4-interface A bad length field or truncated packet was detected in a DECnet packet on the serial line. | ||
| NTF slNotification5 | 1.3.6.1.4.1.2007.1.4.83.2.0.5 | Notification of Event SL.5 Message: 'bad received packet header opcode $1 interface $2' Parameters list: $1: sl5-opcode $2: sl5-interface A network control packet was received with a packet type which did not match any known opcode. | ||
| NTF slNotification6 | 1.3.6.1.4.1.2007.1.4.83.2.0.6 | Notification of Event SL.6 Message: 'bad received packet header protocol $1 interface $2' Parameters list: $1: sl6-protocol $2: sl6-interface A serial line packet was received with a higher level protocol which did not match any known protocol. | ||
| NTF slNotification7 | 1.3.6.1.4.1.2007.1.4.83.2.0.7 | Notification of Event SL.7 Message: 'start selftest interface $1' Parameters list: $1: sl7-interface Self-test is being started on the serial line. | ||
| NTF slNotification8 | 1.3.6.1.4.1.2007.1.4.83.2.0.8 | Notification of Event SL.8 Message: 'send echo packet interface $1' Parameters list: $1: sl8-interface An echo request is being sent on the serial line. | ||
| NTF slNotification9 | 1.3.6.1.4.1.2007.1.4.83.2.0.9 | Notification of Event SL.9 Message: 'receive test packet interface $1' Parameters list: $1: sl9-interface A test packet has been received on the serial line. | ||
| NTF slNotification10 | 1.3.6.1.4.1.2007.1.4.83.2.0.10 | Notification of Event SL.10 Message: 'receive echo acknowledgement packet interface $1' Parameters list: $1: sl10-interface An echo acknowledgement packet has been received on the serial line. | ||
| NTF slNotification11 | 1.3.6.1.4.1.2007.1.4.83.2.0.11 | Notification of Event SL.11 Message: 'receive echo request packet interface $1' Parameters list: $1: sl11-interface An echo acknowledgement packet has been received on the serial line. | ||
| NTF slNotification12 | 1.3.6.1.4.1.2007.1.4.83.2.0.12 | Notification of Event SL.12 Message: 'sending maintenance test packet interface $1' Parameters list: $1: sl12-interface A test packet used for network maintenence is being sent on the serial line. | ||
| NTF slNotification13 | 1.3.6.1.4.1.2007.1.4.83.2.0.13 | Notification of Event SL.13 Message: 'Dropping the received Spanning Tree Bridged packet but bridging is disabled on interface $1' Parameters list: $1: sl13-interface A Bridged packet is received on this serial line interface even though the Spanning Tree Bridging is not enabled on this interface or STB is disabled in the box. | ||
| NTF slNotification14 | 1.3.6.1.4.1.2007.1.4.83.2.0.14 | Notification of Event SL.14 Message: 'Dual Serial Line board in slot $1 firmware download $2' Parameters list: $1: sl14-slot-num $2: sl14-ld-code Dual Serial Line Interface board firmware download has completed with the status shown. | ||
| NTF slNotification15 | 1.3.6.1.4.1.2007.1.4.83.2.0.15 | Notification of Event SL.15 Message: 'Dual Serial Line board slot $1 Power-On Diagnostics status $2' Parameters list: $1: sl15-slot-num $2: sl15-pud-stat Dual Serial Line Board Power-On Diagnostics status completed with the code shown. See Power-On Diagnostics manual for encoding. | ||
| NTF slNotification16 | 1.3.6.1.4.1.2007.1.4.83.2.0.16 | Notification of Event SL.16 Message: '$1 type pakcet filtered for protocol = $2 interface $3' Parameters list: $1: sl16-protocol-type $2: sl16-protocol $3: sl16-interface Protocol type like Ethertype, DSAPytype or SNAPtype packet filtered. This is due to the user supplied protocol filtering information. (STB). | ||
| NTF slNotification17 | 1.3.6.1.4.1.2007.1.4.83.2.0.17 | Notification of Event SL.17 Message: 'Dropped, protocol = $1 enabled but packet arrived as bridged from address $2, interface $3' Parameters list: $1: sl17-protocol-type $2: sl17-src-addr $3: sl17-interface Packet dropped as the protocol type is enabled but packet arrived as bridged. (STB). | ||
| NTF slNotification18 | 1.3.6.1.4.1.2007.1.4.83.2.0.18 | Notification of Event SL.18 Message: 'Dropped, dsap = $1, Protocol filtreing applies, interface $2' Parameters list: $1: sl18-protocol-type $2: sl18-interface Packet dropped as the protocol filtering applies (STB). | ||
| NTF slNotification19 | 1.3.6.1.4.1.2007.1.4.83.2.0.19 | Notification of Event SL.19 Message: 'Cable of type $1 is not compatible with level converter of type $2, interface $3' Parameters list: $1: sl19-cable-type $2: sl19-level-converter-type $3: sl19-interface The cable and the level converter on the interface are not compatible with each other. The self-test will fail. | ||
| NTF slNotification20 | 1.3.6.1.4.1.2007.1.4.83.2.0.20 | Notification of Event SL.20 Message: '$1 cable cannot be used with $2 clocking enabled, interface $3' Parameters list: $1: sl20-cable-type $2: sl20-internal-external $3: sl20-interface There is an incompatibility between the mode of the cable (DCE or DTE) and the type of clocking used. The interface will not be brought up. | ||
| NTF slNotification21 | 1.3.6.1.4.1.2007.1.4.83.2.0.21 | Notification of Event SL.21 Message: 'Self test failed because of modem status, CTS = $1, DSR = $2, DCD = $3, ifc $4' Parameters list: $1: sl21-cts $2: sl21-dsr $3: sl21-dcd $4: sl21-interface The interface failed self test because at least one of the modem signals was off. | ||
| NTF slNotification22 | 1.3.6.1.4.1.2007.1.4.83.2.0.22 | Notification of Event SL.22 Message: 'Modem status change CTS = $1, DSR = $2, DCD = $3, on interface $4' Parameters list: $1: sl22-cts $2: sl22-dsr $3: sl22-dcd $4: sl22-interface A modem status change has occurred. The present state is described. | ||
| NTF slNotification23 | 1.3.6.1.4.1.2007.1.4.83.2.0.23 | Notification of Event SL.23 Message: 'Interface down because of modem status, CTS = $1, DSR = $2, DCD = $3, ifc $4' Parameters list: $1: sl23-cts $2: sl23-dsr $3: sl23-dcd $4: sl23-interface The interface was brought down because one of the modem signals was off. | ||
| NTF slNotification24 | 1.3.6.1.4.1.2007.1.4.83.2.0.24 | Notification of Event SL.24 Message: 'Configured frame size of $1 bytes too large, reducing to $2 bytes, interface $3' Parameters list: $1: sl24-configured-size $2: sl24-maximum-size $3: sl24-interface The user-configured frame size for this interface is larger than the maximum that is allowed for the particular serial line device. The size is reduced to the largest allowable one. | ||
| NTF slNotification25 | 1.3.6.1.4.1.2007.1.4.83.2.0.25 | Notification of Event SL.25 Message: 'bad length in SRT packet actual $1 claimed $2 interface $3' Parameters list: $1: sl25-actual-length $2: sl25-claimed-length $3: sl25-interface A bad length field or truncated packet was detected in a SRT bridge packet. | ||
| NTF slNotification26 | 1.3.6.1.4.1.2007.1.4.83.2.0.26 | Notification of Event SL.26 Message: 'Packet received is shorter than Serial line header, actual $1 interface $2' Parameters list: $1: sl26-actual-length $2: sl26-interface An Incoming Serial Line packet is shorter than a minimally required Serial Line header. Such packet can not be processed and hence freed. | ||
| NTF slNotification27 | 1.3.6.1.4.1.2007.1.4.83.2.0.27 | Notification of Event SL.27 Message: 'No level converter, disabling interface $1' Parameters list: $1: sl27-interface There is no level converter on this port of the Quad Serial Line card. The self-test will fail, and future self-tests will be cancelled. | ||
| NTF slNotification28 | 1.3.6.1.4.1.2007.1.4.83.2.0.28 | Notification of Event SL.28 Message: 'Unknown level converter type $1, disabling interface $2' Parameters list: $1: sl28-converter-type $2: sl28-interface There is a level converter of an unknown type on this port of the Quad Serial Line card. The self-test will fail, and future self-tests will be cancelled. | ||
| NTF slNotification29 | 1.3.6.1.4.1.2007.1.4.83.2.0.29 | Notification of Event SL.29 Message: 'Configured frame size of $1 bytes too small, increasing to $2 bytes, interface $3' Parameters list: $1: sl29-configured-size $2: sl29-minimum-size $3: sl29-interface The user-configured frame size for this interface is smaller than the minimum that is required for the particular serial line device. The size is increased to the minimum allowable one. | ||
| NTF slNotification30 | 1.3.6.1.4.1.2007.1.4.83.2.0.30 | Notification of Event SL.30 Message: 'Maintenance buffer busy, interface $1' Parameters list: $1: sl30-interface The maintenance routine is attempting to send a maintenance frame for Proteon Serial data-link, but the buffer for sending this has not been freed since the previous maintenance. If this happens 3 times in a row, maintenance will fail at the other end of the serial line. | ||
| NTF slNotification31 | 1.3.6.1.4.1.2007.1.4.83.2.0.31 | Notification of Event SL.31 Message: 'No packet for reading counters, interface $1' Parameters list: $1: sl31-interface A buffer could not be allocated when needed to read the statistics counters from the Dual Serial interface. The counters should be successfully updated at the next maintenance, 4 seconds later. | ||
| NTF slNotification32 | 1.3.6.1.4.1.2007.1.4.83.2.0.32 | Notification of Event SL.32 Message: 'Packet buffer allocation number $1 failed, interface $2' Parameters list: $1: sl32-buffer-number $2: sl32-interface The allocation of a packet buffer for a DNX 300 serial line failed. This may be due to a shortage of either buffer memory or heap memory. (See the output of ELS messages GW.061, GW.063, and GW.064). The interface will still try and come up, but with a reduced number of receive packet buffers. | ||
| NTF slNotification33 | 1.3.6.1.4.1.2007.1.4.83.2.0.33 | Notification of Event SL.33 Message: 'Packet buffer number $1 crossed 64 Kbyte page boundary, dropped, ifc $2' Parameters list: $1: sl33-buffer-number $2: sl33-interface A packet buffer was allocated for the DNX 300 serial line, but that buffer crossed a 64 Kbyte memory boundary in the buffer memory. Since all of the receive buffers for a DNX 300 serial line must be in the same 64 Kbyte buffer memory packet, that buffer will be ignored, and no further buffers will be allocated for the device. The interface will still try and come up, but with a reduced number of receive packet buffers. | ||
| NTF slNotification34 | 1.3.6.1.4.1.2007.1.4.83.2.0.34 | Notification of Event SL.34 Message: 'No cable installed or installed cable broken or non-compatible, interface $1' Parameters list: $1: sl34-interface The system does not detect an adapter cable in the network interface port. Self-test will fail. | ||
| NTF slNotification35 | 1.3.6.1.4.1.2007.1.4.83.2.0.35 | Notification of Event SL.35 Message: 'Protocol $1 ($2) can not be bridged over Proteon Serial Line using the pseudo-ethernet bridging method. Interface $3' Parameters list: $1: sl35-protocol-name $2: sl35-protocol-number $3: sl35-interface A protocol that cannot be bridged by Proteon Serial Line's PSEUDO- ETHERNET bridging method has been configured over an interface using PSL PSEUDO-ETH. | ||
| NTF slNotification36 | 1.3.6.1.4.1.2007.1.4.83.2.0.36 | Notification of Event SL.36 Message: 'warning: test on ifc $1' Parameters list: $1: sl36-interface The interface is on mode loopback or echo and the timeout as expired. |
RFC description
Manages SNMP notifications and events generated by Teldat SL subsystem interfaces.
Start monitoring Teldat router, serial/WAN interface modules (serial-line state/negotiation event traps) with a free 30-day trial of IPNetwork Monitor. Import MIBs, browse SNMP OIDs, create custom SNMP monitors, configure alerts, and monitor any SNMP-enabled network device from a single console.