All MIBs › TELDAT-TRAP-SCAD-MIB
Organization: Teldat, S.A.
Last Updated: 2014-01-20
Category: SCADA and Industrial Protocols, Teldat Router Management, Teldat Trap Notifications
Description: Defines Teldat router SCAD (SCADA) event trap notifications.
Start monitoring vendor-neutral, standards-based MIB, any SNMPv3-capable network device (SNMP engine identity/boot/clock status) with a free 30-day trial of IPNetwork Monitor. Import MIBs, browse SNMP OIDs, create custom SNMP monitors, configure alerts, and monitor any SNMP-enabled network device from a single console.
What Is TELDAT-TRAP-SCAD-MIB?
TELDAT-TRAP-SCAD-MIB is a Teldat-specific notification-only MIB defining SNMP traps generated by the router's SCADA (industrial control protocol) event subsystem, referred to as SCAD, used when the router serves as a gateway or relay for SCADA serial/IP traffic. It contains no polled data tables, only numbered trap definitions (scad1 through scad4 in the sample set) carrying varbinds like interface, byte counts, serial address, bad address, state, and a free-text comment/cause field. Its monitoring value is fault/event-oriented: these traps notify an operator of SCADA link or protocol anomalies, such as bad addressing or state changes, which is important in industrial environments where SCADA connectivity failures can affect physical process control. It depends on the underlying SCADA gateway/relay functionality and the specific serial or IP interfaces carrying that traffic. It is deployed on Teldat routers used as SCADA protocol gateways in industrial, utility, or remote telemetry network deployments, where engineers typically start with a TELDAT-TRAP-SCAD-MIB download to load the trap definitions into their SNMP management platform.
IPNetwork Monitor allows you to monitor SNMP objects defined in TELDAT-TRAP-SCAD-MIB. Use the built-in SNMP Monitoring Browser to explore available variables, view their current values and descriptions, and select the objects you want to monitor. You can then create SNMP monitors, configure thresholds, and receive alerts when monitored values change.
Supported Devices
- Teldat router used as a SCADA protocol gateway
Monitoring Examples
As a trap-only MIB with no data tables, monitoring means capturing events at an SNMP trap receiver: scad2-serrial-address together with scad2-state and scad2-bytes-number reports the serial device address, its current state, and traffic volume, useful for detecting a SCADA endpoint that has gone silent or is in an unexpected state. scad3-bad-addr and scad3-interface would flag a specific interface receiving traffic from or destined to an invalid SCADA address, indicating a misconfiguration or corrupted frame. scad4-cause and scad4-state provide a cause code and resulting state for a given SCADA event, useful for root-causing an outage on the industrial link. scadEventsGroup defines the overall set of SCADA-related trap events the device can emit.
This MIB depends on
Related MIBs
Imported Objects
From SNMPv2-SMI
| Integer32 | |
| IpAddress | |
| MODULE-IDENTITY | |
| NOTIFICATION-TYPE | |
| OBJECT-IDENTITY | |
| OBJECT-TYPE |
From SNMPv2-TC
| DisplayString |
From TELDAT-MIB
| telEventTraps | OBJECT-IDENTITY |
OIDs
| OID symbolic | OID numeric | Type | Access | Description |
|---|---|---|---|---|
| I32 scad1_bytes_number | 1.3.6.1.4.1.2007.1.4.178.1.1.1 | Integer32 | accessible-for-notify | Parameter 'bytes-number' in event SCAD.1 |
| STR scad1_interface | 1.3.6.1.4.1.2007.1.4.178.1.1.2 | DisplayString | accessible-for-notify | Parameter 'interface' in event SCAD.1 |
| I32 scad10_bytes | 1.3.6.1.4.1.2007.1.4.178.1.10.1 | Integer32 | accessible-for-notify | Parameter 'bytes' in event SCAD.10 |
| STR scad10_interface | 1.3.6.1.4.1.2007.1.4.178.1.10.2 | DisplayString | accessible-for-notify | Parameter 'interface' in event SCAD.10 |
| I32 scad11_bytes | 1.3.6.1.4.1.2007.1.4.178.1.11.2 | Integer32 | accessible-for-notify | Parameter 'bytes' in event SCAD.11 |
| STR scad11_interface | 1.3.6.1.4.1.2007.1.4.178.1.11.3 | DisplayString | accessible-for-notify | Parameter 'interface' in event SCAD.11 |
| I32 scad11_message_type | 1.3.6.1.4.1.2007.1.4.178.1.11.1 | Integer32 | accessible-for-notify | Parameter 'message-type' in event SCAD.11 |
| I32 scad11_state | 1.3.6.1.4.1.2007.1.4.178.1.11.4 | Integer32 | accessible-for-notify | Parameter 'state' in event SCAD.11 |
| I32 scad12_bytes | 1.3.6.1.4.1.2007.1.4.178.1.12.2 | Integer32 | accessible-for-notify | Parameter 'bytes' in event SCAD.12 |
| IP scad12_foreign_host | 1.3.6.1.4.1.2007.1.4.178.1.12.3 | IpAddress | accessible-for-notify | Parameter 'foreign-host' in event SCAD.12 |
| STR scad12_message_type | 1.3.6.1.4.1.2007.1.4.178.1.12.1 | DisplayString | accessible-for-notify | Parameter 'message-type' in event SCAD.12 |
| I32 scad12_remote_port | 1.3.6.1.4.1.2007.1.4.178.1.12.4 | Integer32 | accessible-for-notify | Parameter 'remote-port' in event SCAD.12 |
| IP scad13_foreign_host | 1.3.6.1.4.1.2007.1.4.178.1.13.1 | IpAddress | accessible-for-notify | Parameter 'foreign-host' in event SCAD.13 |
| I32 scad13_remote_port | 1.3.6.1.4.1.2007.1.4.178.1.13.2 | Integer32 | accessible-for-notify | Parameter 'remote-port' in event SCAD.13 |
| IP scad14_foreign_host | 1.3.6.1.4.1.2007.1.4.178.1.14.1 | IpAddress | accessible-for-notify | Parameter 'foreign-host' in event SCAD.14 |
| I32 scad14_remote_port | 1.3.6.1.4.1.2007.1.4.178.1.14.2 | Integer32 | accessible-for-notify | Parameter 'remote-port' in event SCAD.14 |
| IP scad15_remote_ip | 1.3.6.1.4.1.2007.1.4.178.1.15.1 | IpAddress | accessible-for-notify | Parameter 'remote-ip' in event SCAD.15 |
| I32 scad15_remote_port | 1.3.6.1.4.1.2007.1.4.178.1.15.2 | Integer32 | accessible-for-notify | Parameter 'remote-port' in event SCAD.15 |
| I32 scad16_address | 1.3.6.1.4.1.2007.1.4.178.1.16.1 | Integer32 | accessible-for-notify | Parameter 'address' in event SCAD.16 |
| I32 scad16_bytes | 1.3.6.1.4.1.2007.1.4.178.1.16.2 | Integer32 | accessible-for-notify | Parameter 'bytes' in event SCAD.16 |
| STR scad16_interface | 1.3.6.1.4.1.2007.1.4.178.1.16.3 | DisplayString | accessible-for-notify | Parameter 'interface' in event SCAD.16 |
| I32 scad16_state | 1.3.6.1.4.1.2007.1.4.178.1.16.4 | Integer32 | accessible-for-notify | Parameter 'state' in event SCAD.16 |
| STR scad17_interface | 1.3.6.1.4.1.2007.1.4.178.1.17.2 | DisplayString | accessible-for-notify | Parameter 'interface' in event SCAD.17 |
| STR scad17_message_type | 1.3.6.1.4.1.2007.1.4.178.1.17.1 | DisplayString | accessible-for-notify | Parameter 'message-type' in event SCAD.17 |
| I32 scad17_state | 1.3.6.1.4.1.2007.1.4.178.1.17.3 | Integer32 | accessible-for-notify | Parameter 'state' in event SCAD.17 |
| STR scad18_interface | 1.3.6.1.4.1.2007.1.4.178.1.18.2 | DisplayString | accessible-for-notify | Parameter 'interface' in event SCAD.18 |
| STR scad18_site | 1.3.6.1.4.1.2007.1.4.178.1.18.1 | DisplayString | accessible-for-notify | Parameter 'site' in event SCAD.18 |
| I32 scad18_state | 1.3.6.1.4.1.2007.1.4.178.1.18.3 | Integer32 | accessible-for-notify | Parameter 'state' in event SCAD.18 |
| STR scad19_interface | 1.3.6.1.4.1.2007.1.4.178.1.19.1 | DisplayString | accessible-for-notify | Parameter 'interface' in event SCAD.19 |
| I32 scad19_state | 1.3.6.1.4.1.2007.1.4.178.1.19.2 | Integer32 | accessible-for-notify | Parameter 'state' in event SCAD.19 |
| I32 scad2_bytes_number | 1.3.6.1.4.1.2007.1.4.178.1.2.3 | Integer32 | accessible-for-notify | Parameter 'bytes-number' in event SCAD.2 |
| STR scad2_coment | 1.3.6.1.4.1.2007.1.4.178.1.2.1 | DisplayString | accessible-for-notify | Parameter 'coment' in event SCAD.2 |
| STR scad2_interface | 1.3.6.1.4.1.2007.1.4.178.1.2.4 | DisplayString | accessible-for-notify | Parameter 'interface' in event SCAD.2 |
| I32 scad2_serrial_address | 1.3.6.1.4.1.2007.1.4.178.1.2.2 | Integer32 | accessible-for-notify | Parameter 'serrial-address' in event SCAD.2 |
| I32 scad2_state | 1.3.6.1.4.1.2007.1.4.178.1.2.5 | Integer32 | accessible-for-notify | Parameter 'state' in event SCAD.2 |
| STR scad20_interface | 1.3.6.1.4.1.2007.1.4.178.1.20.1 | DisplayString | accessible-for-notify | Parameter 'interface' in event SCAD.20 |
| I32 scad20_state | 1.3.6.1.4.1.2007.1.4.178.1.20.2 | Integer32 | accessible-for-notify | Parameter 'state' in event SCAD.20 |
| I32 scad21_cause | 1.3.6.1.4.1.2007.1.4.178.1.21.3 | Integer32 | accessible-for-notify | Parameter 'cause' in event SCAD.21 |
| STR scad21_interface | 1.3.6.1.4.1.2007.1.4.178.1.21.4 | DisplayString | accessible-for-notify | Parameter 'interface' in event SCAD.21 |
| IP scad21_ip_host_address | 1.3.6.1.4.1.2007.1.4.178.1.21.2 | IpAddress | accessible-for-notify | Parameter 'ip-host-address' in event SCAD.21 |
| I32 scad21_na | 1.3.6.1.4.1.2007.1.4.178.1.21.1 | Integer32 | accessible-for-notify | Parameter 'na' in event SCAD.21 |
| STR scad22_event | 1.3.6.1.4.1.2007.1.4.178.1.22.1 | DisplayString | accessible-for-notify | Parameter 'event' in event SCAD.22 |
| IP scad22_ip | 1.3.6.1.4.1.2007.1.4.178.1.22.2 | IpAddress | accessible-for-notify | Parameter 'ip' in event SCAD.22 |
| I32 scad22_port | 1.3.6.1.4.1.2007.1.4.178.1.22.3 | Integer32 | accessible-for-notify | Parameter 'port' in event SCAD.22 |
| STR scad23_interface | 1.3.6.1.4.1.2007.1.4.178.1.23.2 | DisplayString | accessible-for-notify | Parameter 'interface' in event SCAD.23 |
| STR scad23_message_type | 1.3.6.1.4.1.2007.1.4.178.1.23.1 | DisplayString | accessible-for-notify | Parameter 'message-type' in event SCAD.23 |
| I32 scad23_state | 1.3.6.1.4.1.2007.1.4.178.1.23.3 | Integer32 | accessible-for-notify | Parameter 'state' in event SCAD.23 |
| STR scad24_interface | 1.3.6.1.4.1.2007.1.4.178.1.24.2 | DisplayString | accessible-for-notify | Parameter 'interface' in event SCAD.24 |
| STR scad24_message_type | 1.3.6.1.4.1.2007.1.4.178.1.24.1 | DisplayString | accessible-for-notify | Parameter 'message-type' in event SCAD.24 |
| I32 scad24_state | 1.3.6.1.4.1.2007.1.4.178.1.24.3 | Integer32 | accessible-for-notify | Parameter 'state' in event SCAD.24 |
| I32 scad25_port | 1.3.6.1.4.1.2007.1.4.178.1.25.1 | Integer32 | accessible-for-notify | Parameter 'port' in event SCAD.25 |
| STR scad26_event | 1.3.6.1.4.1.2007.1.4.178.1.26.1 | DisplayString | accessible-for-notify | Parameter 'event' in event SCAD.26 |
| IP scad26_ip | 1.3.6.1.4.1.2007.1.4.178.1.26.2 | IpAddress | accessible-for-notify | Parameter 'ip' in event SCAD.26 |
| I32 scad26_port | 1.3.6.1.4.1.2007.1.4.178.1.26.3 | Integer32 | accessible-for-notify | Parameter 'port' in event SCAD.26 |
| STR scad27_hex_data | 1.3.6.1.4.1.2007.1.4.178.1.27.4 | DisplayString | accessible-for-notify | Parameter 'hex-data' in event SCAD.27 |
| STR scad27_interface | 1.3.6.1.4.1.2007.1.4.178.1.27.1 | DisplayString | accessible-for-notify | Parameter 'interface' in event SCAD.27 |
| I32 scad27_lenght | 1.3.6.1.4.1.2007.1.4.178.1.27.3 | Integer32 | accessible-for-notify | Parameter 'lenght' in event SCAD.27 |
| I32 scad27_serial_address | 1.3.6.1.4.1.2007.1.4.178.1.27.2 | Integer32 | accessible-for-notify | Parameter 'serial-address' in event SCAD.27 |
| STR scad28_hex_data | 1.3.6.1.4.1.2007.1.4.178.1.28.4 | DisplayString | accessible-for-notify | Parameter 'hex-data' in event SCAD.28 |
| STR scad28_interface | 1.3.6.1.4.1.2007.1.4.178.1.28.1 | DisplayString | accessible-for-notify | Parameter 'interface' in event SCAD.28 |
| I32 scad28_lenght | 1.3.6.1.4.1.2007.1.4.178.1.28.3 | Integer32 | accessible-for-notify | Parameter 'lenght' in event SCAD.28 |
| I32 scad28_serial_address | 1.3.6.1.4.1.2007.1.4.178.1.28.2 | Integer32 | accessible-for-notify | Parameter 'serial-address' in event SCAD.28 |
| STR scad29_interface | 1.3.6.1.4.1.2007.1.4.178.1.29.2 | DisplayString | accessible-for-notify | Parameter 'interface' in event SCAD.29 |
| STR scad29_state | 1.3.6.1.4.1.2007.1.4.178.1.29.1 | DisplayString | accessible-for-notify | Parameter 'state' in event SCAD.29 |
| I32 scad3_bad_addr | 1.3.6.1.4.1.2007.1.4.178.1.3.1 | Integer32 | accessible-for-notify | Parameter 'bad-addr' in event SCAD.3 |
| STR scad3_interface | 1.3.6.1.4.1.2007.1.4.178.1.3.2 | DisplayString | accessible-for-notify | Parameter 'interface' in event SCAD.3 |
| STR scad4_cause | 1.3.6.1.4.1.2007.1.4.178.1.4.1 | DisplayString | accessible-for-notify | Parameter 'cause' in event SCAD.4 |
| STR scad4_interface | 1.3.6.1.4.1.2007.1.4.178.1.4.2 | DisplayString | accessible-for-notify | Parameter 'interface' in event SCAD.4 |
| I32 scad4_state | 1.3.6.1.4.1.2007.1.4.178.1.4.3 | Integer32 | accessible-for-notify | Parameter 'state' in event SCAD.4 |
| STR scad5_interface | 1.3.6.1.4.1.2007.1.4.178.1.5.1 | DisplayString | accessible-for-notify | Parameter 'interface' in event SCAD.5 |
| I32 scad5_state | 1.3.6.1.4.1.2007.1.4.178.1.5.2 | Integer32 | accessible-for-notify | Parameter 'state' in event SCAD.5 |
| STR scad6_error_type | 1.3.6.1.4.1.2007.1.4.178.1.6.1 | DisplayString | accessible-for-notify | Parameter 'error-type' in event SCAD.6 |
| STR scad6_interface | 1.3.6.1.4.1.2007.1.4.178.1.6.2 | DisplayString | accessible-for-notify | Parameter 'interface' in event SCAD.6 |
| I32 scad6_state | 1.3.6.1.4.1.2007.1.4.178.1.6.3 | Integer32 | accessible-for-notify | Parameter 'state' in event SCAD.6 |
| STR scad7_interface | 1.3.6.1.4.1.2007.1.4.178.1.7.2 | DisplayString | accessible-for-notify | Parameter 'interface' in event SCAD.7 |
| I32 scad7_serial_address | 1.3.6.1.4.1.2007.1.4.178.1.7.1 | Integer32 | accessible-for-notify | Parameter 'serial-address' in event SCAD.7 |
| STR scad8_interface | 1.3.6.1.4.1.2007.1.4.178.1.8.4 | DisplayString | accessible-for-notify | Parameter 'interface' in event SCAD.8 |
| I32 scad8_port | 1.3.6.1.4.1.2007.1.4.178.1.8.3 | Integer32 | accessible-for-notify | Parameter 'port' in event SCAD.8 |
| IP scad8_rtu_ip_address | 1.3.6.1.4.1.2007.1.4.178.1.8.2 | IpAddress | accessible-for-notify | Parameter 'rtu-ip-address' in event SCAD.8 |
| I32 scad8_serial_address | 1.3.6.1.4.1.2007.1.4.178.1.8.1 | Integer32 | accessible-for-notify | Parameter 'serial-address' in event SCAD.8 |
| STR scad9_interface | 1.3.6.1.4.1.2007.1.4.178.1.9.1 | DisplayString | accessible-for-notify | Parameter 'interface' in event SCAD.9 |
| scadEventObjects1 | 1.3.6.1.4.1.2007.1.4.178.1.1 | Event SCAD.1 Data has been received from Serial Terminal. | ||
| scadEventObjects10 | 1.3.6.1.4.1.2007.1.4.178.1.10 | Event SCAD.10 Trying to send message to Remote end. | ||
| scadEventObjects11 | 1.3.6.1.4.1.2007.1.4.178.1.11 | Event SCAD.11 A message from Remote end has been received. | ||
| scadEventObjects12 | 1.3.6.1.4.1.2007.1.4.178.1.12 | Event SCAD.12 A TCP Packet has been received. | ||
| scadEventObjects13 | 1.3.6.1.4.1.2007.1.4.178.1.13 | Event SCAD.13 The TCP session has been closed. | ||
| scadEventObjects14 | 1.3.6.1.4.1.2007.1.4.178.1.14 | Event SCAD.14 The TCP session has been closed by the Remote end. | ||
| scadEventObjects15 | 1.3.6.1.4.1.2007.1.4.178.1.15 | Event SCAD.15 The TCP session has been opened by the Remote end. | ||
| scadEventObjects16 | 1.3.6.1.4.1.2007.1.4.178.1.16 | Event SCAD.16 A Message has been transmitted to Serial Terminal. | ||
| scadEventObjects17 | 1.3.6.1.4.1.2007.1.4.178.1.17 | Event SCAD.17 A change ON/OFF has been detected in Serial Control Signal Input. | ||
| scadEventObjects18 | 1.3.6.1.4.1.2007.1.4.178.1.18 | Event SCAD.18 Timeout has occur waiting data. | ||
| scadEventObjects19 | 1.3.6.1.4.1.2007.1.4.178.1.19 | Event SCAD.19 A packet was lost, due TCP Tx overrun error. | ||
| scadEventObjects2 | 1.3.6.1.4.1.2007.1.4.178.1.2 | Event SCAD.2 One OK Message has been received from Serial Terminal. | ||
| scadEventObjects20 | 1.3.6.1.4.1.2007.1.4.178.1.20 | Event SCAD.20 A packet was lost, due TCP is closed. | ||
| scadEventObjects21 | 1.3.6.1.4.1.2007.1.4.178.1.21 | Event SCAD.21 The transfer has been wrong against specified NA and IP addr. | ||
| scadEventObjects22 | 1.3.6.1.4.1.2007.1.4.178.1.22 | Event SCAD.22 TCP generic event was occurred. | ||
| scadEventObjects23 | 1.3.6.1.4.1.2007.1.4.178.1.23 | Event SCAD.23 A change ON/OFF has been make in Serial Control Signal Output. | ||
| scadEventObjects24 | 1.3.6.1.4.1.2007.1.4.178.1.24 | Event SCAD.24 Data error from Serial Terminal has been received. | ||
| scadEventObjects25 | 1.3.6.1.4.1.2007.1.4.178.1.25 | Event SCAD.25 TCP Listen has been closed, due max session number has been reached. | ||
| scadEventObjects26 | 1.3.6.1.4.1.2007.1.4.178.1.26 | Event SCAD.26 An input TCP session has been rejet. | ||
| scadEventObjects27 | 1.3.6.1.4.1.2007.1.4.178.1.27 | Event SCAD.27 Detailed Data send to serial interface. | ||
| scadEventObjects28 | 1.3.6.1.4.1.2007.1.4.178.1.28 | Event SCAD.28 Detailed Data received from serial interface. | ||
| scadEventObjects29 | 1.3.6.1.4.1.2007.1.4.178.1.29 | Event SCAD.29 Configured NSLA track has triggered. | ||
| scadEventObjects3 | 1.3.6.1.4.1.2007.1.4.178.1.3 | Event SCAD.3 A Message with bad address has been received from Serial Terminal. | ||
| scadEventObjects4 | 1.3.6.1.4.1.2007.1.4.178.1.4 | Event SCAD.4 One Bad Message has been received from Serial Terminal. | ||
| scadEventObjects5 | 1.3.6.1.4.1.2007.1.4.178.1.5 | Event SCAD.5 A message with LRC/CRC error has been received from Serial Terminal. | ||
| scadEventObjects6 | 1.3.6.1.4.1.2007.1.4.178.1.6 | Event SCAD.6 A message with error has been received from Remote. | ||
| scadEventObjects7 | 1.3.6.1.4.1.2007.1.4.178.1.7 | Event SCAD.7 Addres received from Serial Terminal is not included in configuration registers list. | ||
| scadEventObjects8 | 1.3.6.1.4.1.2007.1.4.178.1.8 | Event SCAD.8 It's trying the connection against remote IP and P port. | ||
| scadEventObjects9 | 1.3.6.1.4.1.2007.1.4.178.1.9 | Event SCAD.9 The Transfer has been completed successfully. | ||
| scadEventsGroup | 1.3.6.1.4.1.2007.1.4.178.1 | |||
| NTF scadNotification1 | 1.3.6.1.4.1.2007.1.4.178.2.0.1 | Notification of Event SCAD.1 Message: 'Rx Data from Serial Terminal $1 bytes, interface $2' Parameters list: $1: scad1-bytes-number $2: scad1-interface Data has been received from Serial Terminal. | ||
| NTF scadNotification10 | 1.3.6.1.4.1.2007.1.4.178.2.0.10 | Notification of Event SCAD.10 Message: 'Trying to send a message to Remote with $1 bytes. Interface $2' Parameters list: $1: scad10-bytes $2: scad10-interface Trying to send message to Remote end. | ||
| NTF scadNotification11 | 1.3.6.1.4.1.2007.1.4.178.2.0.11 | Notification of Event SCAD.11 Message: 'A message from Remote of $1 type has been received, $2 bytes. Interface $3 state $4' Parameters list: $1: scad11-message-type $2: scad11-bytes $3: scad11-interface $4: scad11-state A message from Remote end has been received. | ||
| NTF scadNotification12 | 1.3.6.1.4.1.2007.1.4.178.2.0.12 | Notification of Event SCAD.12 Message: 'A TCP packet $1 has been received, $2 bytes. rem. IP: $3, Port: $4' Parameters list: $1: scad12-message-type $2: scad12-bytes $3: scad12-foreign-host $4: scad12-remote-port A TCP Packet has been received. | ||
| NTF scadNotification13 | 1.3.6.1.4.1.2007.1.4.178.2.0.13 | Notification of Event SCAD.13 Message: 'The TCP session has been closed. rem. IP: $1, Port: $2' Parameters list: $1: scad13-foreign-host $2: scad13-remote-port The TCP session has been closed. | ||
| NTF scadNotification14 | 1.3.6.1.4.1.2007.1.4.178.2.0.14 | Notification of Event SCAD.14 Message: 'The TCP session has been closed by the Remote end. rem. IP: $1, Port: $2' Parameters list: $1: scad14-foreign-host $2: scad14-remote-port The TCP session has been closed by the Remote end. | ||
| NTF scadNotification15 | 1.3.6.1.4.1.2007.1.4.178.2.0.15 | Notification of Event SCAD.15 Message: 'The TCP session has been opened by the Remote end. Remote IP:$1 , Port: $2' Parameters list: $1: scad15-remote-ip $2: scad15-remote-port The TCP session has been opened by the Remote end. | ||
| NTF scadNotification16 | 1.3.6.1.4.1.2007.1.4.178.2.0.16 | Notification of Event SCAD.16 Message: 'Tx Message to Serial Terminal,address: $1, $2 bytes interface $3 state $4' Parameters list: $1: scad16-address $2: scad16-bytes $3: scad16-interface $4: scad16-state A Message has been transmitted to Serial Terminal. | ||
| NTF scadNotification17 | 1.3.6.1.4.1.2007.1.4.178.2.0.17 | Notification of Event SCAD.17 Message: 'Serial Control Signal Imput change to $1, interface $2 state $3' Parameters list: $1: scad17-message-type $2: scad17-interface $3: scad17-state A change ON/OFF has been detected in Serial Control Signal Input. | ||
| NTF scadNotification18 | 1.3.6.1.4.1.2007.1.4.178.2.0.18 | Notification of Event SCAD.18 Message: 'Timeout waiting data from $1, interface $2 state $3' Parameters list: $1: scad18-site $2: scad18-interface $3: scad18-state Timeout has occur waiting data. | ||
| NTF scadNotification19 | 1.3.6.1.4.1.2007.1.4.178.2.0.19 | Notification of Event SCAD.19 Message: 'Packet lost due TCP Tx overrun error. Interface $1 state $2' Parameters list: $1: scad19-interface $2: scad19-state A packet was lost, due TCP Tx overrun error. | ||
| NTF scadNotification2 | 1.3.6.1.4.1.2007.1.4.178.2.0.2 | Notification of Event SCAD.2 Message: 'Rx Message$1 from Serial Terminal address $2, $3 bytes, interface $4 state $5' Parameters list: $1: scad2-coment $2: scad2-serrial-address $3: scad2-bytes-number $4: scad2-interface $5: scad2-state One OK Message has been received from Serial Terminal. | ||
| NTF scadNotification20 | 1.3.6.1.4.1.2007.1.4.178.2.0.20 | Notification of Event SCAD.20 Message: 'Packet lost due TCP session is closes. Interface $1 state $2' Parameters list: $1: scad20-interface $2: scad20-state A packet was lost, due TCP is closed. | ||
| NTF scadNotification21 | 1.3.6.1.4.1.2007.1.4.178.2.0.21 | Notification of Event SCAD.21 Message: 'The transfer has been wrong, against address $1, IP $2, Cause $3, interface $4' Parameters list: $1: scad21-na $2: scad21-ip-host-address $3: scad21-cause $4: scad21-interface The transfer has been wrong against specified NA and IP addr. | ||
| NTF scadNotification22 | 1.3.6.1.4.1.2007.1.4.178.2.0.22 | Notification of Event SCAD.22 Message: 'The TCP event: $1 . Rem. IP: $2, rem. Port: $3' Parameters list: $1: scad22-event $2: scad22-ip $3: scad22-port TCP generic event was occurred. | ||
| NTF scadNotification23 | 1.3.6.1.4.1.2007.1.4.178.2.0.23 | Notification of Event SCAD.23 Message: 'Serial Control Output change to $1, interface $2 state $3' Parameters list: $1: scad23-message-type $2: scad23-interface $3: scad23-state A change ON/OFF has been make in Serial Control Signal Output. | ||
| NTF scadNotification24 | 1.3.6.1.4.1.2007.1.4.178.2.0.24 | Notification of Event SCAD.24 Message: 'Data ERROR from Serial Terminal has been received type: $1. Interface $2 state $3' Parameters list: $1: scad24-message-type $2: scad24-interface $3: scad24-state Data error from Serial Terminal has been received. | ||
| NTF scadNotification25 | 1.3.6.1.4.1.2007.1.4.178.2.0.25 | Notification of Event SCAD.25 Message: 'Max sessions number has been reached, port $1' Parameters list: $1: scad25-port TCP Listen has been closed, due max session number has been reached. | ||
| NTF scadNotification26 | 1.3.6.1.4.1.2007.1.4.178.2.0.26 | Notification of Event SCAD.26 Message: 'TCP inout session rejet: $1 . Rem. IP: $2, rem. Port: $3' Parameters list: $1: scad26-event $2: scad26-ip $3: scad26-port An input TCP session has been rejet. | ||
| NTF scadNotification27 | 1.3.6.1.4.1.2007.1.4.178.2.0.27 | Notification of Event SCAD.27 Message: 'Data transmitted to serial interface $1 (addr:$2,$3 bytes):$4' Parameters list: $1: scad27-interface $2: scad27-serial-address $3: scad27-lenght $4: scad27-hex-data Detailed Data send to serial interface. | ||
| NTF scadNotification28 | 1.3.6.1.4.1.2007.1.4.178.2.0.28 | Notification of Event SCAD.28 Message: 'Data received from serial interface $1 (addr:$2,$3 bytes):$4' Parameters list: $1: scad28-interface $2: scad28-serial-address $3: scad28-lenght $4: scad28-hex-data Detailed Data received from serial interface. | ||
| NTF scadNotification29 | 1.3.6.1.4.1.2007.1.4.178.2.0.29 | Notification of Event SCAD.29 Message: 'Track nsla triggered(state:$1) ifc $2' Parameters list: $1: scad29-state $2: scad29-interface Configured NSLA track has triggered. | ||
| NTF scadNotification3 | 1.3.6.1.4.1.2007.1.4.178.2.0.3 | Notification of Event SCAD.3 Message: 'Rx Address error from Serial Terminal $1 bytes, interface $2' Parameters list: $1: scad3-bad-addr $2: scad3-interface A Message with bad address has been received from Serial Terminal. | ||
| NTF scadNotification4 | 1.3.6.1.4.1.2007.1.4.178.2.0.4 | Notification of Event SCAD.4 Message: 'Rx Bad Message from Serial Terminal ($1), interface $2 state $3' Parameters list: $1: scad4-cause $2: scad4-interface $3: scad4-state One Bad Message has been received from Serial Terminal. | ||
| NTF scadNotification5 | 1.3.6.1.4.1.2007.1.4.178.2.0.5 | Notification of Event SCAD.5 Message: 'A block with LRC/CRC error has been received from Serial Terminal, interface $1 state $2' Parameters list: $1: scad5-interface $2: scad5-state A message with LRC/CRC error has been received from Serial Terminal. | ||
| NTF scadNotification6 | 1.3.6.1.4.1.2007.1.4.178.2.0.6 | Notification of Event SCAD.6 Message: 'A block with $1 error has been received from Serial Terminal, interface $2 state $3' Parameters list: $1: scad6-error-type $2: scad6-interface $3: scad6-state A message with error has been received from Remote. | ||
| NTF scadNotification7 | 1.3.6.1.4.1.2007.1.4.178.2.0.7 | Notification of Event SCAD.7 Message: 'Address $1 received from Serial Terminal is not included in configuration regiters. Interface $2' Parameters list: $1: scad7-serial-address $2: scad7-interface Addres received from Serial Terminal is not included in configuration registers list. | ||
| NTF scadNotification8 | 1.3.6.1.4.1.2007.1.4.178.2.0.8 | Notification of Event SCAD.8 Message: 'Address $1 is trying the connection against IP $2 Host, Port $3, Interface $4' Parameters list: $1: scad8-serial-address $2: scad8-rtu-ip-address $3: scad8-port $4: scad8-interface It's trying the connection against remote IP and P port. | ||
| NTF scadNotification9 | 1.3.6.1.4.1.2007.1.4.178.2.0.9 | Notification of Event SCAD.9 Message: 'The Transfer has been completed successfully. Interface $1' Parameters list: $1: scad9-interface The Transfer has been completed successfully. | ||
| scadNotifications | 1.3.6.1.4.1.2007.1.4.178.2 | |||
| scadNotificationsPrefix | 1.3.6.1.4.1.2007.1.4.178.2.0 | |||
| scadTrapsMIB | 1.3.6.1.4.1.2007.1.4.178 | This Module Information Base file is defined for managing received SNMP notifications generated by the SCAD event subsystem. |
RFC description
Manages SNMP notifications and events from the SCAD subsystem on Teldat equipment.
Start monitoring Teldat router used as a SCADA protocol gateway (serial/IP telemetry event traps) with a free 30-day trial of IPNetwork Monitor. Import MIBs, browse SNMP OIDs, create custom SNMP monitors, configure alerts, and monitor any SNMP-enabled network device from a single console.