| OID symbolic | OID numeric | Type | Access | Description |
| telProdNpConfigControl | 1.3.6.1.4.1.2007.4.1.1.1 | | | |
| INT telProdNpConfigControlBugsClear | 1.3.6.1.4.1.2007.4.1.1.1.1 | INTEGER | not-accessible | In writing 1 resets all bugs stored in the system, in reading
always 0. |
| INT telProdNpConfigControlReload | 1.3.6.1.4.1.2007.4.1.1.1.2 | INTEGER | read-write | Reset of the device. |
| INT telProdNpConfigControlRestart | 1.3.6.1.4.1.2007.4.1.1.1.3 | INTEGER | read-write | Restart of the device. |
| INT telProdNpConfigControlSaveConfig | 1.3.6.1.4.1.2007.4.1.1.1.4 | INTEGER | read-write | It saves the configuration parameters of the device. |
| INT telProdNpConfigControlOKSet | 1.3.6.1.4.1.2007.4.1.1.1.5 | INTEGER | read-write | Number of processed and returned set by the SNMP agent. If a set to 1
(the only allowed value for set) is realized, the counter is reset to 0. |
| INT telProdNpConfChkSum | 1.3.6.1.4.1.2007.4.1.1.1.6 | INTEGER | read-write | It establishes a backup of the SRAM to check the integrity of the
data contained in it. |
| INT telProdNpConfActDev | 1.3.6.1.4.1.2007.4.1.1.1.7 | INTEGER | read-write | Active Device. Device used to read and write configuration files. |
| INT telProdNpConfConfSavedDev | 1.3.6.1.4.1.2007.4.1.1.1.8 | INTEGER | read-only | Device where the last configuration has been saved. |
| telProdNpConfDataGlobal | 1.3.6.1.4.1.2007.4.1.1.2 | | | |
| STR telProdNpConfDataDescription | 1.3.6.1.4.1.2007.4.1.1.2.1 | DisplayString | read-only | A description of the device which includes hardware type, networking
software and operating system. |
| OID telProdNpConfDataObjectID | 1.3.6.1.4.1.2007.4.1.1.2.2 | OBJECT IDENTIFIER | read-only | Object Identifier assigned to the device |
| STR telProdNpConfDataName | 1.3.6.1.4.1.2007.4.1.1.2.3 | DisplayString | read-write | Name assigned to the device (generally the one of TCP/IP). |
| STR telProdNpConfDataContact | 1.3.6.1.4.1.2007.4.1.1.2.4 | DisplayString | read-write | Contact person; along with other data, as the telephone number. |
| STR telProdNpConfDataLocation | 1.3.6.1.4.1.2007.4.1.1.2.5 | DisplayString | read-write | Location; where the device is located physically. |
| INT telProdNpConfDataServices | 1.3.6.1.4.1.2007.4.1.1.2.6 | INTEGER | read-only | A coded number which indicates the layers for which this node
performs services. |
| TIK telProdNpConfDataUptime | 1.3.6.1.4.1.2007.4.1.1.2.7 | TimeTicks | read-only | Time in hundredths of a second from the last reboot of the device. |
| telProdNpConfDataBuffersRxTable | 1.3.6.1.4.1.2007.4.1.1.2.8 | | not-accessible | BuffersRx list. The value of the interface determines the entry number. |
| telProdNpConfDataBuffersRxEntry | 1.3.6.1.4.1.2007.4.1.1.2.8.1 | | not-accessible | Each entry consists of the router interface number of the device and
the size of the reception buffer. |
| INT telProdNpConfDataBuffersRxIndex | 1.3.6.1.4.1.2007.4.1.1.2.8.1.1 | INTEGER | read-only | Interface number of the router part of the device. It is the table
index, and its value is between 1 until Router-Node, this last one
excluded. |
| INT telProdNpConfDataBuffersRxValue | 1.3.6.1.4.1.2007.4.1.1.2.8.1.2 | INTEGER | read-write | Size of the reception buffer. If the assigned value is less than 5
the default value will be 5, and if it is more than 255
the default value will be 255. |
| INT telProdNpConfDataInactTime | 1.3.6.1.4.1.2007.4.1.1.2.9 | INTEGER | read-write | Maximum time (in minutes) of inactivity of the telnet, after which
session disconnection will take place. |
| telProdNpConfInterfaceAsignation | 1.3.6.1.4.1.2007.4.1.1.6 | | | |
| telProdNpInterfAsigListInitial | 1.3.6.1.4.1.2007.4.1.1.6.1 | | | |
| telProdNpInterfAsigListInitialTable | 1.3.6.1.4.1.2007.4.1.1.6.1.1 | | not-accessible | Interfaces list. It is the existing configuration after the last reset
of the router.
The table index is the interface number. |
| telProdNpInterfAsigListInitialEntry | 1.3.6.1.4.1.2007.4.1.1.6.1.1.1 | | not-accessible | Each entry consists of the index (interface number), the interface
type, the connector and a description of the same one. |
| INT telNpInterfAListInitialIndex | 1.3.6.1.4.1.2007.4.1.1.6.1.1.1.1 | INTEGER | read-only | Interface number. It is the table index. |
| INT telNpInterfAListInitialType | 1.3.6.1.4.1.2007.4.1.1.6.1.1.1.2 | INTEGER | read-only | Number associated to the interface type. |
| INT telNpInterfAListInitialConn | 1.3.6.1.4.1.2007.4.1.1.6.1.1.1.3 | INTEGER | read-only | Number associated to the interface connector. |
| STR telNpInterfAListInitialDescription | 1.3.6.1.4.1.2007.4.1.1.6.1.1.1.4 | DisplayString | read-only | Hardware description of the interface. |
| telProdNpInterfAsig | 1.3.6.1.4.1.2007.4.1.1.6.2 | | | |
| telProdNpInterfAsigTable | 1.3.6.1.4.1.2007.4.1.1.6.2.1 | | not-accessible | Connectors list. The table index is the value of the line index:
LAN, WAN, ISDN, INTERNAL, ROUTER-> NODE, NODE->ROUTER
or CON-270. |
| telProdNpInterfAsigEntry | 1.3.6.1.4.1.2007.4.1.1.6.2.1.1 | | not-accessible | Each entry contains the index, the connector number and the
interface value. |
| INT telNpInterfAsigIndex | 1.3.6.1.4.1.2007.4.1.1.6.2.1.1.1 | INTEGER | read-only | Number associated to the hardware which indexes the table.
The only possible values are: lan1(1), line1(2), line2(3),line3(4),
line4(5), line5(6), line6(7), line7(8), line8(9), lan2(16), isdn1(20),
isdn2(21), internal(30), router-node(31), node-router(32), int-270(33). |
| INT telNpInterfAsigConector | 1.3.6.1.4.1.2007.4.1.1.6.2.1.1.2 | INTEGER | read-only | Number associated to the connector. |
| INT telNpInterfAsigValue | 1.3.6.1.4.1.2007.4.1.1.6.2.1.1.3 | INTEGER | read-write | This variable allows associating a certain protocol type to the
connector.
In reading, this variable shows if the last allocation attempt were
in success (2, ok), in error (3) or if still any attempt has not been
carried out to assign a protocol to a connector (4, indefinite).
In writing, it is only permitted to do a set to some of the values
allowed like possible protocols associated to the connectors.
To LAN lines, the protocol type is determined by the device hardware
(Ethernet or TokenRing), reason why they do not admit Set operations
that try to modify this protocol.
Possible values for WAN lines are:
fr (61),
ppp (59),
pppas (55),
sdlc (63),
x25 (61444),
x28 (11),
atppp-dial (31).
ISDN lines can have two B channels, and its possible values are:
B1 channel:
chb1-dial-fr (40),
chb1-dial-ppp (41),
chb1-dial-x25 (61442)
B2 channel:
chb2-dial-fr (240),
chb2-dial-ppp (241),
chb2-dial-x25 (261442)
An interface MultiLink PPP can also be assigned to ISDN lines, independently
of the type of B channel, since these interfaces are not associated to any
specific connector, nor physical line.
ch-mppp (75)
When doing the allocation, the dial-fr and dial-ppp will always go first
and the MPPP after.
The INTERNAL interface can take the value xst (61445), associated to index
30.
There can be another INTERNAL interface with the value int-270 (61446),
associated to the index 33.
This is the only way to assign the values, and any interrelation different
from the associations above indicated cannot be done.
When a atppp-dial (null, value 31) is assigned to one of the WAN lines
by first time, two interfaces (one after the other) are added: one for the
ATI of the B channel type: X.25(value 18), and another for the particular
DIAL (PPP).
The allocation of the DIAL interfaces (X25-DIAL, FR-DIAL, PPP-DIAL) is
complex.
In general, the allocation is done starting for the connector 1 and after
with the connector 2.
In general, chb1 will be assigned first and chb2 after.
If it is tried to generate a chb2 in a connector which doesn't have chb1,
it returns error.
In case a same connector has FR-dial and/or PPP-dial in a B channel
and X25-dial in the other B channel, FR-dial and / or PPP-dial will be
assigned to chb1.
I. If the device has an only basic access (ISDN) and can carry two B
channels, then these will be chb1 and chb2. They are always present and
are modified individually.
II. If the device has two basic access and can carry two B channels, there
are three possibilities: that they are associate one to each basic access,
that two B channels are associate to one of the accesses and the other one
is empty, and the inverse thing to the previous thing.
A. CHB1 ALLOCATION:
*If a chb1-x25 is assigned to a connector, two things can occur:
- There is chb1 for that connector:
If it is chb1-x25 nothing is done.
If it is chb1-rdsi-base, it is changed to chb1-x25 and chb1-rdsi-base
is eliminated. The PPP-DIAL or FR-DIAL which it has associate are
eliminated if there is no another RDSI-BASE in that connector, otherwise
they stay associated to that RDSI-BASE.
- There isn't chb1 for that connector:
In this case, the other connector has two B channels, chb1 and chb2.
Therefore chb2 of the other connector is modified.
If it is ch2-x25, it is associated to it to the chb1 of the initial connector.
If it is chb2-rdsi-base, it is changed to chb1-x25 of the initial connector
and chb2-rdsi-base is eliminated from its connector. The PPP-DIAL or
FR-DIAL which it has associate, are eliminated if there is no another RDSI-BASE
in its connector, otherwise they stay associated to that RDSI-BASE.
*If a chb1-rdsi-base is assigned to a connector, two things can occur:
- There is chb1 for that connector:
If it is chb1-x25, it is changed to chb1-rdsi-base.
If it is chb1-rdsi-base, PPP-DIAL or FR-DIAL is added to that chb1-rdsi-base.
- There isn't chb1 for that connector:
In this case, the other connector has two B channels, chb1 and chb2.
Therefore chb2 of the other connector is modified. If it is chb2-x25,
it is changed to chb1-rdsi-base. of the initial connector.
If it is chb2-rdsi-base, it is changed to chb1-rdsi-base of the initial connector
and chb2-rdsi-base is eliminated from its connector. The PPP-DIAL or
FR-DIAL which it has associate, are eliminated if there is no another RDSI-BASE
in its connector, otherwise they stay associated to that RDSI-BASE.
B. CHB2 ALLOCATION:
*If a chb2-x25 is assigned to a connector (this is always done after having
associated the chb1 to that connector), two things can occur:
- There is chb2 for that connector:
If it is chb2-x25 nothing is done.
If it is chb2-rdsi-base, it is changed to chb2-x25 and chb2-rdsi-base
is eliminated. The PPP-DIAL or FR-DIAL which it has associate are
eliminated if there is no another RDSI-BASE in that connector, otherwise
they stay associated to that RDSI-BASE.
- There isn't chb2 for that connector:
In this case, the other connector has a B channel (chb1), therefore chb1
of the other connector is modified.
If it is ch1-x25, it is associated to it to the chb2 of the initial connector.
If it is chb1-rdsi-base, it is changed to chb2-x25 of the initial connector
and chb1-rdsi-base is eliminated from its connector. The PPP-DIAL or
FR-DIAL which it has associate, are eliminated if there is no another RDSI-BASE
in its connector, otherwise they stay associated to that RDSI-BASE.
*If a chb2-rdsi-base is assigned to a connector (this is always done
after having associated the chb1 to that connector), two things can occur:
- There is chb1 for that connector:
If it is chb2-x25, it is changed to chb2-rdsi-base.
If it is chb2-rdsi-base, PPP-DIAL or FR-DIAL is added to that chb2-rdsi-base.
- There isn't chb2 for that connector:
In this case, the other connector has a B channel (chb1), therefore
the chb1 of the other connector is modified.
If it is chb1-x25, it is changed to chb2-rdsi-base. of the initial connector.
If it is chb1-rdsi-base, it is changed to chb2-rdsi-base of the initial connector
and chb1-rdsi-base is eliminated from its connector. The PPP-DIAL or
FR-DIAL which it has associate, are eliminated if there is no another RDSI-BASE
in its connector, otherwise they stay associated to that RDSI-BASE.
III. If the device has two basic accesses and can carry 4 B channels, they
will be chb1 and chb2 for the RDSI1, and chb1 and chb2 for the RDSI2.
They are always present and are modified individually.
When a FR-DIAL or PPP-DIAL is assigned to one of the ISDN lines
by first time, two interfaces are added: one for the ISDN and another
for the particular DIAL (FR or PPP).
A X25-DIAL by each ISDN basic access can only be assigned. There can
be several FR-DIAL and PPP-DIAL in a same ISDN basic access.
X25-dial cannot coexist with FR-dial nor PPP-dial in a same ISDN basic
access. For that reason, when assigning a X25-dial to an ISDN connector,
the ISDN-base is eliminated, and if there is no another RDSI-base associated
to that connector, possible PPP-dial and FR-dial are also eliminated; the
same happens if there is a X25-dial in a basic access and it is tried to
add a FR-dial or a PPP-dial: then the X25-DIAL is eliminated.
The maximum number of interfaces that the device can have is 40.
In addition, there can be 6 DIAL in total between the two basic accesses, for
each ISDN basic access. |
| telProdNpInterfAsigListModify | 1.3.6.1.4.1.2007.4.1.1.6.3 | | | |
| telProdNpInterfAsigListModifyTable | 1.3.6.1.4.1.2007.4.1.1.6.3.1 | | not-accessible | List of the modified interfaces. It is the actual interfaces configuration,
considering the modifications done in the router.
The table index is the interface number. |
| telProdNpInterfAsigListModifyEntry | 1.3.6.1.4.1.2007.4.1.1.6.3.1.1 | | not-accessible | Each entry contains the information of the index (the interface
number), the variable to delete an interface (whenever it is permitted),
the interface type, the connector, and a description of the interface type
and connector. |
| INT telNpInterfAListModifyIndex | 1.3.6.1.4.1.2007.4.1.1.6.3.1.1.1 | INTEGER | read-only | Interface type. It is the index table. |
| INT telNpInterfAListModifyDelInterf | 1.3.6.1.4.1.2007.4.1.1.6.3.1.1.2 | INTEGER | read-write | This variable allows deleting an interface.
The operation is done if it is permitted to delete this interface.
A set to 1 must be done to delete the interface (it returns 1(valid)
if it is done with success and error in opposite case).
Get returns 2(last-set-ok) if the last set was done with success,
3(last-set-non-ok) if it resulted in error and 4 in another case. |
| INT telNpInterfAListModifyType | 1.3.6.1.4.1.2007.4.1.1.6.3.1.1.3 | INTEGER | read-only | Number associated to the interface type. |
| INT telNpInterfAListModifyConn | 1.3.6.1.4.1.2007.4.1.1.6.3.1.1.4 | INTEGER | read-only | Number associated to the interface connector. |
| STR telNpInterfAListModifyTypeDescription | 1.3.6.1.4.1.2007.4.1.1.6.3.1.1.5 | DisplayString | read-only | Description of the interface type. |
| STR telNpInterfAListModifyConnDescription | 1.3.6.1.4.1.2007.4.1.1.6.3.1.1.6 | DisplayString | read-only | Description of the connector type. |
| INT telNpInterfAListModifyAdminStat | 1.3.6.1.4.1.2007.4.1.1.6.3.1.1.7 | INTEGER | read-write | Administrative or wished status of the interface. |
| INT telNpInterfAListModifyOperStat | 1.3.6.1.4.1.2007.4.1.1.6.3.1.1.8 | INTEGER | read-only | Operative state of the interface. |
| INT telNpInterfADelAll | 1.3.6.1.4.1.2007.4.1.1.6.4 | INTEGER | read-write | This variable deletes all interfaces configuration that has been
modified until the moment. |