| OID symbolic | OID numeric | Type | Access | Description |
| sleAlarmMgr | 1.3.6.1.4.1.6296.101.15 | | | This MIB contains all needed informations about
Alarm Manager. |
| NTF sleAlarmTrapAlarm | 1.3.6.1.4.1.6296.101.15.3.3.2 | | | Notify Alarm Raise/Clear TRAPS to NMS for each entry in the Table |
| NTF sleAlarmTrapEvent | 1.3.6.1.4.1.6296.101.15.3.3.3 | | | Notify Event Occur TRAPS to NMS for each entry in the Table |
| sleAMAcoBase | 1.3.6.1.4.1.6296.101.15.5 | | | |
| NTF sleAMAcoChanged | 1.3.6.1.4.1.6296.101.15.5.3.1 | | | Notification for Alarm ACO configuration change |
| sleAMAcoControl | 1.3.6.1.4.1.6296.101.15.5.2 | | | |
| SLE sleAMAcoControlReqResult | 1.3.6.1.4.1.6296.101.15.5.2.5 | SleControlRequestResultType | read-only | Result of the last command. |
| INT sleAMAcoControlRequest | 1.3.6.1.4.1.6296.101.15.5.2.1 | INTEGER | read-write | The configuration commands, and user can configure
functions via setting this entry as proper value. |
| AMA sleAMAcoControlSet | 1.3.6.1.4.1.6296.101.15.5.2.6 | AMAlarmAco | read-write | ACO control
acoOff(1) : buzzer operation enable.
acoOn(2) : buzzer operation disable.
acoOpr(3) : current buzzer cut. |
| G32 sleAMAcoControlTimer | 1.3.6.1.4.1.6296.101.15.5.2.3 | Gauge32 | read-write | the wait-time until setRequest
end. In case of short-time command, this value is 0 |
| TIK sleAMAcoControlTimeStamp | 1.3.6.1.4.1.6296.101.15.5.2.4 | TimeTicks | read-only | the time stamp of the last command. (don.t care) |
| SLE sleAMAcogControlStatus | 1.3.6.1.4.1.6296.101.15.5.2.2 | SleControlStatusType | read-only | status of user command. User have to check this
value as .busy. or .idle. before do setRequest. |
| AMA sleAMAcoInfo | 1.3.6.1.4.1.6296.101.15.5.1.1 | AMAlarmAco | read-only | ACO control configuration
acoOff(1) : buzzer operation enable.
acoOn(2) : buzzer operation disable.
acoOpr(3) : current buzzer cut. |
| sleAMAcoInfoEntry | 1.3.6.1.4.1.6296.101.15.5.1 | | | |
| sleAMAcoNotification | 1.3.6.1.4.1.6296.101.15.5.3 | | | |
| OCT sleAMAlarmTrapNeId | 1.3.6.1.4.1.6296.101.15.1 | OCTET STRING | read-only | use for NE idendification when alarm(or event) trap
system MAC address |
| AMA sleAMConfigAlarmClassId | 1.3.6.1.4.1.6296.101.15.2.1.1.1 | AMAlarmClassId | read-only | Class ID starts from 1 to 65535 for the system.
And these IDs are defined by alarm-client |
| AMA sleAMConfigAlarmClearGuardTime | 1.3.6.1.4.1.6296.101.15.2.1.1.7 | AMAlarmGuardTime | read-only | Alarm clear Soaking time. When any alarm is cleared, this attribute
specifies how much time the alarm should be soaked before notifying
to Alarm manager
range:1 ~ 30, (if '0', no soaking time) |
| AMT sleAMConfigAlarmEnableState | 1.3.6.1.4.1.6296.101.15.2.1.1.5 | AMTrapState | read-only | Alarm Trap State. Based on the trap state,
the alarm will be notified to NMS. If the TRAP STATE is enabled
then the alarm will be notified else wont be notified.
enable (1)
disabe (0) |
| AMA sleAMConfigAlarmId | 1.3.6.1.4.1.6296.101.15.2.1.1.2 | AMAlarmId | read-only | Alarm ID
Alarm ID starts from 1 to 65535 for the system.
And these IDs are defined by alarm-client |
| INT sleAMConfigAlarmLed | 1.3.6.1.4.1.6296.101.15.2.1.1.8 | INTEGER | read-write | Alarm led configuration.
Determinde led operate or not, when alarms occur.
off(0): led not operate
on(1) : led operate |
| OCT sleAMConfigAlarmName | 1.3.6.1.4.1.6296.101.15.2.1.1.3 | OCTET STRING | read-write | Alarm Name string |
| AMA sleAMConfigAlarmRaiseGuardTime | 1.3.6.1.4.1.6296.101.15.2.1.1.6 | AMAlarmGuardTime | read-only | Alarm raise Soaking time.
When any alarm is raised, this attribute
specifies how much time the alarm should be soaked before notifying
to Alarm manager
range:1 ~ 30, (if '0', no soaking time) |
| AMA sleAMConfigAlarmSeverity | 1.3.6.1.4.1.6296.101.15.2.1.1.4 | AMAlarmSeverity | read-only | Alarm severity: The default severity is pre-defined by each Alarm manager clients
critical(1),
major(2),
minor(3),
warning(4),
intermediate(5), |
| sleAMConfigBase | 1.3.6.1.4.1.6296.101.15.2 | | | |
| NTF sleAMConfigClearGuardTimeChanged | 1.3.6.1.4.1.6296.101.15.2.3.4 | | | Notification for Clear Soak time change |
| sleAMConfigControl | 1.3.6.1.4.1.6296.101.15.2.2 | | | |
| AMA sleAMConfigControlAlarmClassId | 1.3.6.1.4.1.6296.101.15.2.2.6 | AMAlarmClassId | read-write | Alarm Manager Class ID |
| AMA sleAMConfigControlAlarmId | 1.3.6.1.4.1.6296.101.15.2.2.7 | AMAlarmId | read-write | Alarm Manager Alarm Index |
| AMA sleAMConfigControlClearGuardTime | 1.3.6.1.4.1.6296.101.15.2.2.11 | AMAlarmGuardTime | read-write | Alarm clear Soaking time. When any alarm is cleared, this attribute
specifies how much time the alarm should be soaked before notifying
to Alarm manager
range:1 ~ 30, (if '0', no soaking time) |
| AMT sleAMConfigControlEnableState | 1.3.6.1.4.1.6296.101.15.2.2.9 | AMTrapState | read-write | Alarm Trap State. Based on the trap state,
the alarm will be notified to NMS. If the TRAP STATE is enabled
then the alarm will be notified else wont be notified.
enable (1)
disabe (0) |
| I32 sleAMConfigControlLed | 1.3.6.1.4.1.6296.101.15.2.2.12 | Integer32 | read-write | Alarm led configuration.
Determinde led operate or not, when alarms occur.
off(0): led not operate
on(1) : led operate |
| AMA sleAMConfigControlRaiseGuardTime | 1.3.6.1.4.1.6296.101.15.2.2.10 | AMAlarmGuardTime | read-write | Alarm Raise Soaking time. When any alarm is raised, this attribute
specifies how much time the alarm should be soaked before notifying
to Alarm manager
range:1 ~ 30, (if '0', no soaking time) |
| SLE sleAMConfigControlReqResult | 1.3.6.1.4.1.6296.101.15.2.2.5 | SleControlRequestResultType | read-only | Result of the last command. |
| INT sleAMConfigControlRequest | 1.3.6.1.4.1.6296.101.15.2.2.1 | INTEGER | read-write | The configuration commands, and user can configure
functions via setting this entry as proper value. |
| AMA sleAMConfigControlSeverity | 1.3.6.1.4.1.6296.101.15.2.2.8 | AMAlarmSeverity | read-write | Alarm Class Severity
critical(1),
major(2),
minor(3),
warning(4),
ignore(5),
default(6) |
| SLE sleAMConfigControlStatus | 1.3.6.1.4.1.6296.101.15.2.2.2 | SleControlStatusType | read-only | status of user command. User have to check this
value as .busy. or .idle. before do setRequest. |
| G32 sleAMConfigControlTimer | 1.3.6.1.4.1.6296.101.15.2.2.3 | Gauge32 | read-write | the wait-time until setRequest
end. In case of short-time command, this value is 0 |
| TIK sleAMConfigControlTimeStamp | 1.3.6.1.4.1.6296.101.15.2.2.4 | TimeTicks | read-only | the time stamp of the last command. (don.t care) |
| NTF sleAMConfigEnableStateChanged | 1.3.6.1.4.1.6296.101.15.2.3.2 | | | Notification for Class Trap State change |
| sleAMConfigEntry | 1.3.6.1.4.1.6296.101.15.2.1.1 | | not-accessible | |
| NTF sleAMConfigLedChanged | 1.3.6.1.4.1.6296.101.15.2.3.5 | | | Notification for Alarm led configuration change |
| sleAMConfigNotification | 1.3.6.1.4.1.6296.101.15.2.3 | | | |
| NTF sleAMConfigRaiseGuardTimeChanged | 1.3.6.1.4.1.6296.101.15.2.3.3 | | | Notification for Raise Soak time change |
| NTF sleAMConfigSeverityChanged | 1.3.6.1.4.1.6296.101.15.2.3.1 | | | Notification for Alarm severity change |
| I32 sleAMConfigSpecificId | 1.3.6.1.4.1.6296.101.15.2.1.1.9 | Integer32 | read-write | Alarm Configuration specific ID(4bytes)
classId and alarmID are combinded with a specificID
* 1st,2nd Bytes - ClassId
* 3rd,4th bytes - alarmID |
| sleAMConfigTable | 1.3.6.1.4.1.6296.101.15.2.1 | | not-accessible | This table is the class Master Alarm table.
It gets populated when system init is done.
And it contains all the class alarms supported for the device |
| AMA sleAMCurrentAlarmClassId | 1.3.6.1.4.1.6296.101.15.3.1.1.3 | AMAlarmClassId | read-only | Class ID starts from 1 to 65535 for the system.
And these IDs are defined by alarm-client |
| NTF sleAMCurrentAlarmCleared | 1.3.6.1.4.1.6296.101.15.3.3.1 | | | Notification for current alarm clear |
| AMA sleAMCurrentAlarmId | 1.3.6.1.4.1.6296.101.15.3.1.1.4 | AMAlarmId | read-only | Alarm ID
Alarm ID starts from 1 to 65535 for the system.
And these IDs are defined by alarm-client |
| AMA sleAMCurrentAlarmReason | 1.3.6.1.4.1.6296.101.15.3.1.1.7 | AMAlarmReason | read-only | reasion string |
| AMA sleAMCurrentAlarmSeverity | 1.3.6.1.4.1.6296.101.15.3.1.1.6 | AMAlarmSeverity | read-only | Current Alarm Severity:
critical(1),
major(2),
minor(3),
warning(4) |
| AMA sleAMCurrentAlarmSource | 1.3.6.1.4.1.6296.101.15.3.1.1.2 | AMAlarmSrc | read-only | alarm location infomation
|type|length|value|type|length|value|....
type (1-byte) : alarm location type
length(1-byte) : alarm location value length
value (length-bytes) : alarm location value |
| ALA sleAMCurrentAlarmStatus | 1.3.6.1.4.1.6296.101.15.3.1.1.5 | AlarmStatus | read-only | Current Alarm State:
raised (1),
masked(2) |
| sleAMCurrentBase | 1.3.6.1.4.1.6296.101.15.3 | | | |
| sleAMCurrentControl | 1.3.6.1.4.1.6296.101.15.3.2 | | | |
| SLE sleAMCurrentControlReqResult | 1.3.6.1.4.1.6296.101.15.3.2.5 | SleControlRequestResultType | read-only | Result of the last command. |
| INT sleAMCurrentControlRequest | 1.3.6.1.4.1.6296.101.15.3.2.1 | INTEGER | read-write | The configuration commands, and user can configure
functions via setting this entry as proper value.
1: all current alarm clear
2: current alarm clear by SeqId
3: current alarm clear by Source(location) |
| U32 sleAMCurrentControlSeqId | 1.3.6.1.4.1.6296.101.15.3.2.6 | Unsigned32 | read-write | current alarmControl Sequence ID.(0, all mcurrent alarm cleared)
Valid only if the sleAMHistoryControlRequest value is set to 2(alarmHistoryClearBySeqId). |
| AMA sleAMCurrentControlSource | 1.3.6.1.4.1.6296.101.15.3.2.7 | AMAlarmSrc | read-write | current alarm clear location infomation
|type|length|value|type|length|value|....
type (1-byte) : alarm location type
length(1-byte) : alarm location value length
value (length-bytes) : alarm location value |
| SLE sleAMCurrentControlStatus | 1.3.6.1.4.1.6296.101.15.3.2.2 | SleControlStatusType | read-only | status of user command. User have to check this
value as .busy. or .idle. before do setRequest. |
| G32 sleAMCurrentControlTimer | 1.3.6.1.4.1.6296.101.15.3.2.3 | Gauge32 | read-write | the wait-time until setRequest
end. In case of short-time command, this value is 0 |
| TIK sleAMCurrentControlTimeStamp | 1.3.6.1.4.1.6296.101.15.3.2.4 | TimeTicks | read-only | the time stamp of the last command. (don.t care) |
| sleAMCurrentEntry | 1.3.6.1.4.1.6296.101.15.3.1.1 | | not-accessible | |
| sleAMCurrentNotification | 1.3.6.1.4.1.6296.101.15.3.3 | | | |
| U32 sleAMCurrentSeqId | 1.3.6.1.4.1.6296.101.15.3.1.1.1 | Unsigned32 | read-only | alarm sequence id
key of current alarm table
it generated by alarm-manager automatically |
| INT sleAMCurrentSpecificId | 1.3.6.1.4.1.6296.101.15.3.1.1.9 | INTEGER | read-write | Current Alarm specific ID(4bytes)
classId and alarmID are combinded with a specificID
* 1st,2nd Bytes - ClassId
* 3rd,4th bytes - alarmID |
| sleAMCurrentTable | 1.3.6.1.4.1.6296.101.15.3.1 | | not-accessible | This table contains the current active
alarms for the Alarm Class. Each Row in this table
gets populated when any Alarm is raised |
| TIK sleAMCurrentTimeAndDate | 1.3.6.1.4.1.6296.101.15.3.1.1.8 | TimeTicks | read-only | Current Alarm Time and Date |
| AMA sleAMHistoryAlarmClassId | 1.3.6.1.4.1.6296.101.15.4.1.1.3 | AMAlarmClassId | read-only | Class ID starts from 1 to 65535 for the system.
And these IDs are defined by alarm-client |
| NTF sleAMHistoryAlarmCleared | 1.3.6.1.4.1.6296.101.15.4.3.1 | | | Notification for History Class cleared |
| AMA sleAMHistoryAlarmId | 1.3.6.1.4.1.6296.101.15.4.1.1.4 | AMAlarmId | read-only | History Alarm ID
Alarm ID starts from 1 to 65535 for the system.
And these IDs are defined by alarm-client |
| AMA sleAMHistoryAlarmReason | 1.3.6.1.4.1.6296.101.15.4.1.1.7 | AMAlarmReason | read-write | History alarm Reason string |
| AMA sleAMHistoryAlarmSeverity | 1.3.6.1.4.1.6296.101.15.4.1.1.6 | AMAlarmSeverity | read-only | History alarm Severity
critical(1),
major(2),
minor(3),
warning(4) |
| AMA sleAMHistoryAlarmSource | 1.3.6.1.4.1.6296.101.15.4.1.1.2 | AMAlarmSrc | read-only | |type|length|value|type|length|value|....
type (1-byte) : alarm location type
length(1-byte) : alarm location value length
value (length-bytes) : alarm location value |
| ALA sleAMHistoryAlarmStatus | 1.3.6.1.4.1.6296.101.15.4.1.1.5 | AlarmStatus | read-only | History Alarm State:
cleared (0),
raised (1),
masked(2) |
| TIK sleAMHistoryAlarmTimeDate | 1.3.6.1.4.1.6296.101.15.4.1.1.8 | TimeTicks | read-only | History Alarm Time and Date |
| sleAMHistoryBase | 1.3.6.1.4.1.6296.101.15.4 | | | |
| sleAMHistoryControl | 1.3.6.1.4.1.6296.101.15.4.2 | | | |
| SLE sleAMHistoryControlReqResult | 1.3.6.1.4.1.6296.101.15.4.2.5 | SleControlRequestResultType | read-only | Result of the last command. |
| INT sleAMHistoryControlRequest | 1.3.6.1.4.1.6296.101.15.4.2.1 | INTEGER | read-write | The configuration commands, and user can configure
functions via setting this entry as proper value.
clearAlarmHistory : clears the alarms from the History Table
1: all alarm history clear
2: alarm history clear by SeqId
3: alarm history clear by Source(location) |
| SLE sleAMHistoryControlStatus | 1.3.6.1.4.1.6296.101.15.4.2.2 | SleControlStatusType | read-only | status of user command. User have to check this
value as .busy. or .idle. before do setRequest. |
| G32 sleAMHistoryControlTimer | 1.3.6.1.4.1.6296.101.15.4.2.3 | Gauge32 | read-write | the wait-time until setRequest
end. In case of short-time command, this value is 0 |
| TIK sleAMHistoryControlTimeStamp | 1.3.6.1.4.1.6296.101.15.4.2.4 | TimeTicks | read-only | the time stamp of the last command. (don.t care) |
| U32 sleAMHistoryControSeqId | 1.3.6.1.4.1.6296.101.15.4.2.6 | Unsigned32 | read-write | Alarm History Control Sequence ID.
Specify cleared history alarm ID
(0, all alarm history cleared) |
| AMA sleAMHistoryControSource | 1.3.6.1.4.1.6296.101.15.4.2.7 | AMAlarmSrc | read-write | alarm history clear location infomation
Valid only if the sleAMHistoryControlRequest value is set to 3(alarmHistoryClearBySource).
|type|length|value|type|length|value|....
type (1-byte) : alarm location type
length(1-byte) : alarm location value length
value (length-bytes) : alarm location value |
| sleAMHistoryEntry | 1.3.6.1.4.1.6296.101.15.4.1.1 | | not-accessible | |
| sleAMHistoryNotification | 1.3.6.1.4.1.6296.101.15.4.3 | | | |
| U32 sleAMHistorySeqId | 1.3.6.1.4.1.6296.101.15.4.1.1.1 | Unsigned32 | read-only | Alarm History Sequence ID. This sequence Id is
maintained based on the TRAP sent. |
| I32 sleAMHistorySpecificId | 1.3.6.1.4.1.6296.101.15.4.1.1.9 | Integer32 | read-write | Alarm History specific ID(4bytes)
classId and alarmID are combinded with a specificID
* 1st,2nd Bytes - ClassId
* 3rd,4th bytes - alarmID |
| sleAMHistoryTable | 1.3.6.1.4.1.6296.101.15.4.1 | | not-accessible | This Table is used to for keeping the Alarm History |
| sleAMLedBase | 1.3.6.1.4.1.6296.101.15.6 | | | |
| NTF sleAMLedChanged | 1.3.6.1.4.1.6296.101.15.6.3.1 | | | Notification for LED configuration change |
| sleAMLedControl | 1.3.6.1.4.1.6296.101.15.6.2 | | | |
| SLE sleAMLedControlReqResult | 1.3.6.1.4.1.6296.101.15.6.2.5 | SleControlRequestResultType | read-only | Result of the last command. |
| INT sleAMLedControlRequest | 1.3.6.1.4.1.6296.101.15.6.2.1 | INTEGER | read-write | The configuration commands, and user can configure
functions via setting this entry as proper value. |
| AMA sleAMLedControlSet | 1.3.6.1.4.1.6296.101.15.6.2.7 | AMAlarmLed | read-write | LED control configuration
ledOff(1) : LED operation disable.
ledOn(2) : LED operation enable.
ledOpr(3) : current LED off. |
| INT sleAMLedControlSeverity | 1.3.6.1.4.1.6296.101.15.6.2.6 | INTEGER | read-write | LED Alarm Severity
critical(1),
major(2),
minor(3), |
| SLE sleAMLedControlStatus | 1.3.6.1.4.1.6296.101.15.6.2.2 | SleControlStatusType | read-only | status of user command. User have to check this
value as .busy. or .idle. before do setRequest. |
| G32 sleAMLedControlTimer | 1.3.6.1.4.1.6296.101.15.6.2.3 | Gauge32 | read-write | the wait-time until setRequest
end. In case of short-time command, this value is 0 |
| TIK sleAMLedControlTimeStamp | 1.3.6.1.4.1.6296.101.15.6.2.4 | TimeTicks | read-only | the time stamp of the last command. (don.t care) |
| I32 sleAMLedCount | 1.3.6.1.4.1.6296.101.15.6.1.1.3 | Integer32 | read-write | alarm count of the associated led |
| sleAMLedEntry | 1.3.6.1.4.1.6296.101.15.6.1.1 | | not-accessible | |
| sleAMLedNotification | 1.3.6.1.4.1.6296.101.15.6.3 | | | |
| AMA sleAMLedSet | 1.3.6.1.4.1.6296.101.15.6.1.1.2 | AMAlarmLed | read-write | ACO control configuration
acoOff(1) : buzzer operation enable.
acoOn(2) : buzzer operation disable.
acoOpr(3) : current buzzer cut. |
| INT sleAMLedSeverity | 1.3.6.1.4.1.6296.101.15.6.1.1.1 | INTEGER | read-write | LED Alarm Severity
critical(1),
major(2),
minor(3), |
| sleAMLedTable | 1.3.6.1.4.1.6296.101.15.6.1 | | not-accessible | This table contains the LED status and configuration. |