All MIBs › SL-ALARM-MIB
Organization: Smartoptics
Last Updated: 2000-08-28
Description: MIB for monitoring SONET/SDH and optical alarms (LOS, LOF, AIS, RFI, signal degrade) on Smartoptics SiteLight network elements
Start monitoring vendor-neutral, standards-based MIB, any SNMPv3-capable network device (SNMP engine identity/boot/clock status) with a free 30-day trial of IPNetwork Monitor. Import MIBs, browse SNMP OIDs, create custom SNMP monitors, configure alerts, and monitor any SNMP-enabled network device from a single console.
What Is SL-ALARM-MIB?
SL-ALARM-MIB is a vendor-specific SNMP module from Smartoptics for its SiteLight optical transport network elements, dedicated entirely to alarm management for SONET/SDH and optical transmission faults. It defines a per-interface alarm configuration table along with alarm type, severity, and service-affecting classification for conditions such as Loss of Signal (LOS), Loss of Frame (LOF), Alarm Indication Signal (AIS), Remote Failure Indication (RFI), and signal degrade. Its monitoring purpose is entirely fault/hardware status oriented: it lets an administrator see which optical alarms are currently active on which interface, their severity and whether they are service-affecting, when they occurred, and whether an operator has acknowledged them, which is essential for triaging optical link failures quickly. It builds on standard SONET/SDH alarm concepts (LOS/LOF/AIS/RFI) defined by telecom transmission standards, giving it a conceptual dependency on those industry conventions even though it is implemented as a Smartoptics enterprise MIB. It would be deployed in optical transport/DWDM network operations centers monitoring SiteLight network elements for line-level faults, and NOC engineers can perform an SL-ALARM-MIB download to load these alarm objects into their MIB browser.
IPNetwork Monitor allows you to monitor SNMP objects defined in SL-ALARM-MIB. Use the built-in SNMP Monitoring Browser to explore available variables, view their current values and descriptions, and select the objects you want to monitor. You can then create SNMP monitors, configure thresholds, and receive alerts when monitored values change.
Supported Devices
- Smartoptics SiteLight optical network element
- SONET/SDH transport equipment
Monitoring Examples
The slAlarmConfigTable (slAlarmConfigEntry, indexed by slAlarmIfIndex) exposes slAlarmType, slAlarmSeverity, and slAlarmServiceAffect per interface, letting an operator poll for any interface currently reporting a service-affecting LOS or LOF alarm. slAlarmActive, slAlarmTimeStamp, and slAlarmAcknowledged let a NOC operator see whether a raised alarm is still active, when it first occurred, and whether anyone (tracked via slAlarmAckUser) has acknowledged it, while the slAlarmTraps notification would push new alarm events to a management station in real time rather than requiring constant polling.
What Can Be Monitored
- active optical alarms (LOS/LOF/AIS/RFI/signal degrade)
- alarm severity
- service-affecting status
- alarm acknowledgment state
- alarm timestamp
- per-interface alarm configuration
Imported Objects
From IF-MIB
| InterfaceIndex |
From PerfHist-TC-MIB
| PerfCurrentCount | |
| PerfIntervalCount | |
| PerfTotalCount |
From SL-MAIN-MIB
| slMain | MODULE-IDENTITY |
| slmTrapLogId | OBJECT-TYPE |
From SNMPv2-CONF
| MODULE-COMPLIANCE | |
| NOTIFICATION-GROUP | |
| OBJECT-GROUP |
From SNMPv2-SMI
| MODULE-IDENTITY | |
| NOTIFICATION-TYPE | |
| OBJECT-TYPE |
From SNMPv2-TC
| DisplayString | |
| TEXTUAL-CONVENTION | |
| TimeStamp | |
| TruthValue |
How to Use in IPNetwork Monitor
Example using slAlarmSeverity OID:
OIDs
RFC description
Synchronoss Labs (or similar vendor) MIB for alarm and event management; vendor-private.
Start monitoring Smartoptics SiteLight optical network element, SONET/SDH transport equipment (per-interface alarm status) with a free 30-day trial of IPNetwork Monitor. Import MIBs, browse SNMP OIDs, create custom SNMP monitors, configure alerts, and monitor any SNMP-enabled network device from a single console.