All MIBs › SHE-PHYSICAL-MIB
Organization: Nokia Siemens Networks
Last Updated: 2009-06-17
Description: Nokia Siemens Networks SHE DSLAM physical entity management for cards, slots, and ports, including admin/oper state, user labels, and card plug/unplug notifications
Start monitoring vendor-neutral, standards-based MIB, any SNMPv3-capable network device (SNMP engine identity/boot/clock status) with a free 30-day trial of IPNetwork Monitor. Import MIBs, browse SNMP OIDs, create custom SNMP monitors, configure alerts, and monitor any SNMP-enabled network device from a single console.
What Is SHE-PHYSICAL-MIB?
SHE-PHYSICAL-MIB is a Nokia Siemens Networks (originally Siemens) MIB for the SHE DSLAM broadband access platform, modeling the physical equipment inventory of the chassis. It exposes data about logical and physical entities such as slots, cards, and ports, including their administrative and operational state, user-assigned labels, and hardware presence. Its central monitoring purpose is hardware status: it lets an operator track whether a card or port is administratively enabled and operationally up, and it generates notifications when a card is plugged in or removed, making it a primary tool for detecting hardware insertion/removal events and equipment faults in the chassis. It likely complements or parallels the standard IETF ENTITY-MIB physical entity model, adapting it to SHE-specific slot/card semantics. It is typically deployed on Nokia Siemens Networks SHE DSLAM platforms in broadband access networks where remote visibility into card and slot status is required for maintenance and fault management. Engineers can download the SHE-PHYSICAL-MIB file directly to load it into their MIB browser.
IPNetwork Monitor allows you to monitor SNMP objects defined in SHE-PHYSICAL-MIB. Use the built-in SNMP Monitoring Browser to explore available variables, view their current values and descriptions, and select the objects you want to monitor. You can then create SNMP monitors, configure thresholds, and receive alerts when monitored values change.
Supported Devices
- Nokia Siemens Networks SHE DSLAM chassis
Monitoring Examples
No object/table names were supplied for this module, so a concrete example cannot be grounded in real identifiers; in general terms, an operator would poll a slot/card table for administrative and operational state per slot and rely on card plug/unplug traps to detect when a line card has been physically removed, inserted, or has failed, which is the core use case described in the module.
What Can Be Monitored
- slot/card administrative state
- slot/card operational state
- user-assigned equipment labels
- card plug/unplug events
This MIB depends on
Related MIBs
Imported Objects
From AN-SHE-MIB
| she | OBJECT-IDENTITY |
From ENTITY-MIB
| PhysicalIndex | |
| entPhysicalIndex | OBJECT-TYPE |
From IF-MIB
| InterfaceIndex | |
| ifAdminStatus | OBJECT-TYPE |
| ifIndex | OBJECT-TYPE |
| ifOperStatus | OBJECT-TYPE |
From SHE-ALARMING-MIB
| SheAlarmSevProfileIndex | |
| sheAlarmReportingSource | OBJECT-TYPE |
| sheAlarmReportingSourceType | OBJECT-TYPE |
| sheAlarmSeverity | OBJECT-TYPE |
| sheAlarmTimeAndDate | OBJECT-TYPE |
From SHE-TC-MIB
| SheAdminStateType | |
| SheControlStatusType | |
| ShePermissionType |
From SNMP-FRAMEWORK-MIB
| SnmpAdminString |
From SNMPv2-CONF
| MODULE-COMPLIANCE | |
| NOTIFICATION-GROUP | |
| OBJECT-GROUP |
From SNMPv2-SMI
| Integer32 | |
| MODULE-IDENTITY | |
| NOTIFICATION-TYPE | |
| OBJECT-TYPE | |
| Unsigned32 |
From SNMPv2-TC
| DisplayString | |
| TEXTUAL-CONVENTION | |
| TruthValue |
OIDs
| OID symbolic | OID numeric | Type | Access | Description |
|---|---|---|---|---|
| shePhysical | 1.3.6.1.4.1.231.7.1.2.2.1.1 | The MIB module for representing multiple logical entities for the SHE Equipment management. | ||
| shePhysContainerObjects | 1.3.6.1.4.1.231.7.1.2.2.1.1.1 | |||
| shePhysContainerTable | 1.3.6.1.4.1.231.7.1.2.2.1.1.1.1 | not-accessible | The container/slot table. | |
| shePhysContainerEntry | 1.3.6.1.4.1.231.7.1.2.2.1.1.1.1.1 | not-accessible | Entry of the container table. The entries represent the slots of a SHE shelf | |
| OCT shePhysContainerAccCardTypes | 1.3.6.1.4.1.231.7.1.2.2.1.1.1.1.1.1 | OCTET STRING | read-only | This attribute identifies the types of plug-in units to be accepted by this slot. The strings are separated by newline characters. That means CR LF. Valid strings are: emptyCardType Central cards (support depend on NE release and used shelf): CXUGE:4E:E CXUCGE:4E:E CXUB1GE:4E:E CXUB2GE:4:E CXUC2GE:4:E CXUB3GE:4:E CXUB21GE:4:E CXUG1B:2O:4E:E (>=3.7M) DSL IU card's (support depend on used NE release): IUSHDSL:48S:E IUSHDSL:48B:E IUADSL:48P:E IUADSL:72A:E IUADSL:72B:E (obsolete) IUADSL:72P:IFX IUADSL:72I:IFX IUADSL:72AI:WC IUADSL:72AJ:WC IUVDSL:24D:IFX IUVDSL:24D2:IFX IUADSL:72A:CG IUADSL:72B:CG IUVDSL:24P:E IUVDSL:48P:E IUVDSL:48I:E (obsolete) IUADSL:72A:CGH IUADSL:72B:CGH IUADSL:72J:CGH IUSHDSL:48E:E IUSHDSL:48E:8Q:E (>=R2.8 maintenance) IUVDSL:48I2:E (>=R2.8) IUVDSL:48P2:E (>=R2.8) IUSHDSL:48E:ME:E (>=R3.7M) IUADSL:72B:M:CG (>=R3.7M) IUADSL:72B:ME:CG (>=R3.7M) IUADSL:72J:ME:CG (>=R3.7M) IUVDSL:48I3:M:E (>=R3.7M) IUVDSL:48I3:ME:E (>=R3.7M) IUVDSL:48J3:ME:E (>=R3.7M) Subtending card (with R3.7M also used as UNI card): IU1GE:10O:SYN:E VoIP-Cards (only supported if NE support VoIP at all): VPLU-S72-POTS:E IU:32I4:E IU:32I2:E VPLU:72P:E VPLU:72P1:E (>=R2.8M) VPLU:72P2:E (>=R2.8M) Powermodules (support depend on NE release and used shelf): PM1:E PM2:E PM3:A PM:UPL:E PM:UPL:R:E PM:UPL:A PM1:R:E PM1:R:A PM:R:A Powermodules for new shelftypes 2. generation -> 2G (>= R2.8 maintenance): PM:UPL:2G:E PM:UPL:2G:A PM1:R:2G:E PM:R:2G:E PM:R:2G:A PM:ONU:2G:E Boards for hiX5622 R1.0: (obsolete because release was canceled) CXUMGE:4:E SBXDSL:16P:E SBXDSL:16:E Board for hiX5608 (MiniIPD): HIX5608:E |
| SHE shePhysContainerSlotStatus | 1.3.6.1.4.1.231.7.1.2.2.1.1.1.1.1.4 | ShePhysSlotStatusType | read-only | Indicates whether a slot is empty or used. |
| STR shePhysContainerConfiguredCardType | 1.3.6.1.4.1.231.7.1.2.2.1.1.1.1.1.5 | DisplayString | read-only | This attribute identifies the card type configured for this slot. Valid strings for card types are according to content of shePhysContainerAccCardTypes. |
| STR shePhysContainerPluggedCardType | 1.3.6.1.4.1.231.7.1.2.2.1.1.1.1.1.6 | DisplayString | read-only | This attribute identifies the card type plugged for this slot. Valid strings for card types are according to content of shePhysContainerAccCardTypes. |
| shePhysCardObjects | 1.3.6.1.4.1.231.7.1.2.2.1.1.2 | |||
| shePhysCardTable | 1.3.6.1.4.1.231.7.1.2.2.1.1.2.1 | not-accessible | Table containing the plug-in unit entries. | |
| shePhysCardEntry | 1.3.6.1.4.1.231.7.1.2.2.1.1.2.1.1 | not-accessible | Entry of shePhysCardTable. Each entry is used to represent a card independently whether it is present or not (feature offline configuration). Cards can be created either by auto-configuration (plug-in) or by user command. Notifications : shePhysStateChangeOper. shePhysStateChangeAdmin. shePhysCardCreated. shePhysCardDeleted. Alarm traps when a fault has been detected or cleared. | |
| SHE shePhysCardAdminState | 1.3.6.1.4.1.231.7.1.2.2.1.1.2.1.1.1 | ShePhysCardAdminStateType | read-only | This attribute shows the administrative state of the plugin unit. In the transition from lock to unlock the plug-in unit is diagnosed. Default is notEquipped except for controller cards. The AdminState of controller cards is always unlocked. Planned is very similar to the locked state. Planned is used for configuration of cards without having a card equipped. A correct card being plugged leads to an auto-configuration of the card: the AdminState changes automatically from planned to unlocked. |
| SHE shePhysCardAvailState | 1.3.6.1.4.1.231.7.1.2.2.1.1.2.1.1.2 | ShePhysAvailabilityStateType | read-only | The availability state of a card. |
| SHE shePhysCardOperState | 1.3.6.1.4.1.231.7.1.2.2.1.1.2.1.1.3 | ShePhysCardOperStateType | read-only | The operational state of a card. |
| SHE shePhysCardProtCapability | 1.3.6.1.4.1.231.7.1.2.2.1.1.2.1.1.4 | ShePhysProtectionCapabilityType | read-only | The protection modes the card can work: -bit0=1: Card can work as standalone card. -bit1=1: Card can work as standby card. |
| SHE shePhysCardProtMode | 1.3.6.1.4.1.231.7.1.2.2.1.1.2.1.1.5 | ShePhysProtectionModeType | read-only | The redundancy mode the card is running. -standaloneCard: The card works as standalone board. No redundancy is supported. -protectionCard: The card works in redundancy mode. |
| SHE shePhysCardProtDefaultRole | 1.3.6.1.4.1.231.7.1.2.2.1.1.2.1.1.6 | ShePhysDefaultRoleType | read-only | Defines the default role of the card (e.g. after power on) if more than one card which belong to the same protection group are become availible at the same time. Note, this attribute is only valid if shePhysCardProtCapability = protectionCard. -working: The card becomes the active card by default. -protecting: The card becomes the standby card by default. |
| SHE shePhysCardProtDynamicRole | 1.3.6.1.4.1.231.7.1.2.2.1.1.2.1.1.7 | ShePhysDynamicRoleType | read-only | The dynamic role of card. Note, this attribute is only valid if shePhysCardProtMode = protectionCard. -active: The card is the active card. -standby: The card is the standby card. -notDefined: If there is no card plugged, it is not possible to say which card will become the active or standby card. |
| INT shePhysCardProtGroupId | 1.3.6.1.4.1.231.7.1.2.2.1.1.2.1.1.8 | INTEGER | read-only | The ID of protection group this card belongs to. Cards with the same Id can protect each other. Note, this attribute is only valid if shePhysCardProtCapability = protectionCard. |
| SHE shePhysCardProtState | 1.3.6.1.4.1.231.7.1.2.2.1.1.2.1.1.9 | ShePhysProtState | read-only | The current state of the protection: -unknown If the dynamic role of the cards which belong to a protection group is not set yet, there is no information about the protection state available. -active_noRedundancy: The card is the active card but is not protected by a standby card. -active_protected: The card is the active card is is protected by a standby card. -active_degraded: The card is the active card but not all functionality is protected by the standby card. -standby_notPresent: The card is the standby card but it is not available. -standby_booting: The card is the standby card but is still booting. -standby_protecting: The card is the standby card and protects the active card. -standby_degraded: The card is the standby card but can not take over all functionality of the current active board. Note, this attribute is only valid if shePhysCardProtCapability = protectionCard. |
| SHE shePhysCardAlarmSeverityIndex | 1.3.6.1.4.1.231.7.1.2.2.1.1.2.1.1.10 | SheAlarmSevProfileIndex | read-only | It is a pointer to the instance of the alarm severity profile that contains the severity assignments for alarms reported by this managed entity. Default is 1. |
| SHE shePhysCardUpgradeState | 1.3.6.1.4.1.231.7.1.2.2.1.1.2.1.1.11 | ShePhysUpgradeStateType | read-only | Informs about the state of the SW upgrade task during loading and the result at the end of loading the current plug-in unit. NOTE: The parameter is set to obsolete state with R3.7M. Also former releases does not report a valid information on this parameter. Valid informations about SW upgrade could only be retrieved via sheSystemSwMaintenanceTaskTable. |
| OCT shePhysCardSwRunningLoad | 1.3.6.1.4.1.231.7.1.2.2.1.1.2.1.1.12 | OCTET STRING | read-only | Informs about the currently running load. |
| OCT shePhysCardSwStoredLoad | 1.3.6.1.4.1.231.7.1.2.2.1.1.2.1.1.13 | OCTET STRING | read-only | Informs about the currently stored load. |
| INT shePhysCardTemperatureCurrent | 1.3.6.1.4.1.231.7.1.2.2.1.1.2.1.1.14 | INTEGER | read-only | Current temperature of a card - 255 means unknown value. |
| shePhysCardControl | 1.3.6.1.4.1.231.7.1.2.2.1.1.2.2 | |||
| SHE shePhysCardControlRequest | 1.3.6.1.4.1.231.7.1.2.2.1.1.2.2.1 | ShePhysCardControlRequestType | read-write | The card commands : changeAdminState: changes the shePhysCardAdminState of a card. AdminState of controller cards cannot be changed. changeAlarmSeverityProfile: changes the shePhysCardAlarmSeverityIndex of a card. This is the pointer to a alarm severity profile. createCard: creates plugin units. Acceptable in state NotEquipped and when object does not exist. The AdminState after creation, possible values are Planned or Locked, is specified as command parameter. The command is not accepted for CXUs. These HW objects are automatically created. The acceptable CardTypes are specified in the slot attribute shePhysContainerAccCardTypes. The content of this attribute changes after the creation to values allowed for the convert command. deleteCard: deletes a card. Acceptable only in state Planned/Locked. The command is not accepted for CXUs. CXUs are automatically deleted when board redundancy is disabled. The AdminState changes to NotEquipped. convertCard: converts the type of card. Acceptable only within the same card group, e.g. ADSL to ADSL according to content of types listed in shePhysContainerAccCardTypes. convertCard allowed in state Planned/Locked. Notifications: shePhysCardControlResult when a command has finished. reset commands: resetSystem: reset of system (all cards) and activates loads after SW download. The main card will perform a restart. resetSystemWithDefaultConf : restart with default configuration is performed. resetCard: after SW download to activate the new load of a specific card. resetCardAllOfType: after SW download of cards of the same type to activate the new load. Notifications : shePhysCardReset at beginning of reset. shePhysCardResetEnd at end of reset. shePhysCardControlResult for reset of CXU in case of a failure occured after the reset has been accepted. changeAlarmSeverityProfile: the alarm severity profile is changed for a specific card. THIS REQUEST WILL NOT LONGER BE SUPPORTED BY NE R2.5: setTemperatureThreshold: configure the temperature threshold which is used. When temperature reaches the threshold, alarm is turned on. |
| SHE shePhysCardControlStatus | 1.3.6.1.4.1.231.7.1.2.2.1.1.2.2.2 | SheControlStatusType | read-only | The status of a user command. |
| STR shePhysCardControlPhysicalName | 1.3.6.1.4.1.231.7.1.2.2.1.1.2.2.3 | SnmpAdminString | read-write | A valid string for a card. Identifies the type of card which should be created. Default is \0. |
| PHY shePhysCardControlContainedInIndex | 1.3.6.1.4.1.231.7.1.2.2.1.1.2.2.4 | PhysicalIndex | read-write | The entPhysicalIndex of the slot which contains the card. |
| U32 shePhysCardControlTimer | 1.3.6.1.4.1.231.7.1.2.2.1.1.2.2.5 | Unsigned32 | read-only | The maximum wait time for the manager for a long running user command. |
| SHE shePhysCardControlReqResult | 1.3.6.1.4.1.231.7.1.2.2.1.1.2.2.6 | ShePhysCardControlRequestResultType | read-only | The result of the last user command. |
| U32 shePhysCardControlTimeStamp | 1.3.6.1.4.1.231.7.1.2.2.1.1.2.2.7 | Unsigned32 | read-only | The time stamp of the last command (end of command). |
| SHE shePhysCardControlAdminStateChange | 1.3.6.1.4.1.231.7.1.2.2.1.1.2.2.8 | ShePhysAdminStateChangeType | read-write | Selects the desired adminstrative state. |
| SHE shePhysCardControlAdminStateCreate | 1.3.6.1.4.1.231.7.1.2.2.1.1.2.2.9 | ShePhysAdminStateCreateType | read-write | Selects the desired adminstrative state in user command createCard. |
| INT shePhysCardControlTemperatureThreshold | 1.3.6.1.4.1.231.7.1.2.2.1.1.2.2.10 | INTEGER | read-write | The temperature threshold for all cards. THIS ELEMENT WILL NOT LONGER BE SUPPORTED BY NE up R2.5. |
| PHY shePhysCardControlEntPhysicalIndex | 1.3.6.1.4.1.231.7.1.2.2.1.1.2.2.13 | PhysicalIndex | read-write | The entPhysicalIndex of the plugin unit which should get the reset. |
| SHE shePhysCardControlAlarmSeverityIndex | 1.3.6.1.4.1.231.7.1.2.2.1.1.2.2.14 | SheAlarmSevProfileIndex | read-write | The new AlarmSeverityIndex of the alarm severity profile assigned to the card. |
| sheTemperatureObjects | 1.3.6.1.4.1.231.7.1.2.2.1.1.2.3 | |||
| INT shePhysCardTemperaturePowerDownOn | 1.3.6.1.4.1.231.7.1.2.2.1.1.2.3.1 | INTEGER | read-only | Temperature threshold for generation of shePhysCardTemperaturePowerDown alarm for line cards. IU will start now with action to reduce power consumption. |
| INT shePhysCardTemperaturePowerDownOff | 1.3.6.1.4.1.231.7.1.2.2.1.1.2.3.2 | INTEGER | read-only | Temperature threshold for clearing of shePhysCardOverTemperatureReset alarm for the line cards. |
| INT shePhysCardOverTemperatureResetOn | 1.3.6.1.4.1.231.7.1.2.2.1.1.2.3.3 | INTEGER | read-only | Temperature threshold for the generation of the shePhysCardOverTemperatureReset alarm for line cards. CXU has forced IU tp reset state, to prevend from further damages. |
| INT shePhysCardOverTemperatureResetOff | 1.3.6.1.4.1.231.7.1.2.2.1.1.2.3.4 | INTEGER | read-only | Temperature threshold for the clearing the shePhysCardOverTemperatureReset alarm for line cards. |
| I32 shePhysCardTemperatureThreshold | 1.3.6.1.4.1.231.7.1.2.2.1.1.2.3.5 | Integer32 | read-only | THIS ELEMENT WILL NOT LONGER BE SUPPORTED BY NE up R2.5. Temperature threshold for all cards of shePhysCardOverTemperatureThreshold. |
| INT shePhysCardTemperatureWarningOn | 1.3.6.1.4.1.231.7.1.2.2.1.1.2.3.6 | INTEGER | read-only | Temperature threshold for generation of shePhysCardTemperatureWarning alarm for line cards. The NE will not start any actions in that case. It is only warning for changed temperature conditions. |
| INT shePhysCardTemperatureWarningOff | 1.3.6.1.4.1.231.7.1.2.2.1.1.2.3.7 | INTEGER | read-only | Temperature threshold for clearing of shePhysCardTemperatureWarning alarm for line cards. The NE will not start any actions in that case. It is only warning for changed temperature conditions. |
| sheTemperatureControlObjects | 1.3.6.1.4.1.231.7.1.2.2.1.1.2.3.10 | |||
| SHE shePhysCardTemperatureControlRequest | 1.3.6.1.4.1.231.7.1.2.2.1.1.2.3.10.1 | ShePhysControlRequestType | read-write | The card commands : changeTemperatureWarningThreshold: changes the shePhysCardTemperatureWarningThreshold's. |
| SHE shePhysCardTemperatureControlStatus | 1.3.6.1.4.1.231.7.1.2.2.1.1.2.3.10.2 | SheControlStatusType | read-only | The status of a user command. |
| U32 shePhysCardTemperatureControlTimer | 1.3.6.1.4.1.231.7.1.2.2.1.1.2.3.10.3 | Unsigned32 | read-only | The maximum wait time for the manager for a long running user command. |
| SHE shePhysCardTemperatureControlReqResult | 1.3.6.1.4.1.231.7.1.2.2.1.1.2.3.10.4 | ShePhysCardControlRequestResultType | read-only | The result of the last user command. |
| U32 shePhysCardTemperatureControlTimeStamp | 1.3.6.1.4.1.231.7.1.2.2.1.1.2.3.10.5 | Unsigned32 | read-only | The time stamp of the last command (end of command). |
| INT shePhysCardTemperatureControlWarningOn | 1.3.6.1.4.1.231.7.1.2.2.1.1.2.3.10.6 | INTEGER | read-write | Temperature threshold for generation of shePhysCardTemperatureWarning alarm for line cards. The NE will not start any actions in that case. It is only warning for changed temperature conditions. |
| INT shePhysCardTemperatureControlWarningOff | 1.3.6.1.4.1.231.7.1.2.2.1.1.2.3.10.7 | INTEGER | read-write | Temperature threshold for clearing of shePhysCardTemperatureWarning alarm for line cards. The NE will not start any actions in that case. It is only warning for changed temperature conditions. |
| shePhysPortObjects | 1.3.6.1.4.1.231.7.1.2.2.1.1.3 | |||
| shePhysPortTable | 1.3.6.1.4.1.231.7.1.2.2.1.1.3.1 | not-accessible | The port table extension of the IfTable. Provides the mapping information concerning port and card the port is contained and the alarm severity profile. | |
| shePhysPortEntry | 1.3.6.1.4.1.231.7.1.2.2.1.1.3.1.1 | not-accessible | Entry of the port table. Represents a physical interface (a port). | |
| PHY shePhysPortEntPhysicalIndex | 1.3.6.1.4.1.231.7.1.2.2.1.1.3.1.1.1 | PhysicalIndex | read-only | The entPhysical index of the card this port is contained in. |
| INT shePhysPortId | 1.3.6.1.4.1.231.7.1.2.2.1.1.3.1.1.2 | INTEGER | read-only | The port number/port ID related to the card this port is contained in. |
| SHE shePhysPortAlarmSeverityIndex | 1.3.6.1.4.1.231.7.1.2.2.1.1.3.1.1.3 | SheAlarmSevProfileIndex | read-only | A pointer to the instance of the alarm severity profile that contains the severity assignments for alarms reported by this managed entity. Default is 1. |
| OCT shePhysPortUserLabel | 1.3.6.1.4.1.231.7.1.2.2.1.1.3.1.1.4 | OCTET STRING | read-only | Port specific ASCII identification. This string is only used by the ACI to identifying a physical UserPort. The data is stored in NE but has no further meaning for the NE himself. |
| U32 shePhysPortAdminStateLastChangeTime | 1.3.6.1.4.1.231.7.1.2.2.1.1.3.1.1.5 | Unsigned32 | read-only | The timestamp when this port last times changes adminstate. New parameter with SHE R2.8 maintenance. |
| U32 shePhysPortOperStateUpLastChangeTime | 1.3.6.1.4.1.231.7.1.2.2.1.1.3.1.1.6 | Unsigned32 | read-only | The timestamp when this port last times reaches operstate UP. New parameter with SHE R2.8 maintenance. |
| U32 shePhysPortOperStateDownLastChangeTime | 1.3.6.1.4.1.231.7.1.2.2.1.1.3.1.1.7 | Unsigned32 | read-only | The timestamp when this port last times reaches operstate DOWN. New parameter with SHE R2.8 maintenance. |
| shePhysPortControl | 1.3.6.1.4.1.231.7.1.2.2.1.1.3.2 | |||
| SHE shePhysPortControlRequest | 1.3.6.1.4.1.231.7.1.2.2.1.1.3.2.1 | ShePhysPortControlRequestType | read-write | The port commands : changeAdminState: the AdminState of the current port shall be changed. changeAlarmSeverityProfile: the alarm severity profile of the port is changed. resetStatisticCounters: reset all statistic counters in if- and ifx-table for this port. changeUserLabel: change the value of the UserLabel for this port. changeOperStateTrapEnablePermission: change the permission to send operstate trap for this port. Notifications : shePhysPortControlResult at the command ending in case of long running command. |
| SHE shePhysPortControlStatus | 1.3.6.1.4.1.231.7.1.2.2.1.1.3.2.2 | SheControlStatusType | read-only | The status of a user command. |
| NUM shePhysPortControlIfIndex | 1.3.6.1.4.1.231.7.1.2.2.1.1.3.2.3 | InterfaceIndex | read-write | The IfIndex of the port that shall be configured. |
| SHE shePhysPortControlAlarmSeverityIndex | 1.3.6.1.4.1.231.7.1.2.2.1.1.3.2.4 | SheAlarmSevProfileIndex | read-write | The new AlarmSeverityIndex of the alarm severity profile assigned to the port. |
| SHE shePhysPortControlAdminState | 1.3.6.1.4.1.231.7.1.2.2.1.1.3.2.5 | SheAdminStateType | read-write | The desired AdminState of the port that shall be configured. |
| U32 shePhysPortControlTimeStamp | 1.3.6.1.4.1.231.7.1.2.2.1.1.3.2.6 | Unsigned32 | read-only | The time stamp of the last command (end of command). |
| U32 shePhysPortControlTimer | 1.3.6.1.4.1.231.7.1.2.2.1.1.3.2.7 | Unsigned32 | read-only | The maximum wait time for the manager for command ending in case of long running user commands. The manager reads this value from the PPE SHE. The end of request indicates the trap ShePhysRiResult . |
| SHE shePhysPortControlReqResult | 1.3.6.1.4.1.231.7.1.2.2.1.1.3.2.8 | ShePhysPortControlRequestResultType | read-only | The result of the last user command. |
| OCT shePhysPortControlUserLabel | 1.3.6.1.4.1.231.7.1.2.2.1.1.3.2.9 | OCTET STRING | read-write | Port specific ASCII identification. This string is only used by the ACI to identifying a physical UserPort. The data is stored in NE but has no further meaning for the NE himself. |
| SHE shePhysPortControlOperStateTrapEnable | 1.3.6.1.4.1.231.7.1.2.2.1.1.3.2.10 | ShePermissionType | read-write | Enable/disable OperStateTrap's. Current status could be read from ifx-table. |
| shePhysPortNEInfo | 1.3.6.1.4.1.231.7.1.2.2.1.1.3.3 | |||
| U32 shePhysPortAdslCount | 1.3.6.1.4.1.231.7.1.2.2.1.1.3.3.1 | Unsigned32 | read-only | This attribute returns the current number of available physical port's of type ADSL (ifType 94) of the NE. The attribute could be used by the management system for licensing. |
| U32 shePhysPortShdslCount | 1.3.6.1.4.1.231.7.1.2.2.1.1.3.3.2 | Unsigned32 | read-only | This attribute returns the current number of available physical port's of type SHDSL (ifType 96) of the NE. The attribute could be used by the management system for licensing. |
| U32 shePhysPortVdslCount | 1.3.6.1.4.1.231.7.1.2.2.1.1.3.3.3 | Unsigned32 | read-only | This attribute returns the current number of available physical port's of type VDSL (ifType 97) of the NE. The attribute could be used by the management system for licensing. |
| U32 shePhysPortAdsl2Count | 1.3.6.1.4.1.231.7.1.2.2.1.1.3.3.4 | Unsigned32 | read-only | This attribute returns the current number of available physical port's of type ADSL2 (ifType 230) of the NE. The attribute could be used by the management system for licensing. |
| U32 shePhysPortVoipCount | 1.3.6.1.4.1.231.7.1.2.2.1.1.3.3.5 | Unsigned32 | read-only | This attribute returns the current number of available physical port's of type VOIP (ifType 104) of the NE. The attribute could be used by the management system for licensing. |
| U32 shePhysPortIsdnCount | 1.3.6.1.4.1.231.7.1.2.2.1.1.3.3.6 | Unsigned32 | read-only | This attribute returns the current number of available physical port's of type ISDN (ifType 63) of the NE. The attribute could be used by the management system for licensing. |
| shePhysRedundancyObjects | 1.3.6.1.4.1.231.7.1.2.2.1.1.4 | |||
| shePhysBoardRedundancyControl | 1.3.6.1.4.1.231.7.1.2.2.1.1.4.1 | |||
| SHE shePhysBrdControlRequest | 1.3.6.1.4.1.231.7.1.2.2.1.1.4.1.1 | ShePhysBrdControlRequestType | read-write | The user commands for board redundancy and switch over. enableBoardRedundancy, disableBoardRedundancy: to enable/disable board redundancy. boardSwitchOver: applicable when board redundancy is enabled and the standby board is in the state ShePhysCardProtState = standby_protecting (There is no traffic interruption in case of swithover.) boardSwitchOverForced: applicable when board redundancy is enabled, ShePhysCardProtState = standby_protecting or standby_degraded. modifyRedundancyFeature: applicable only for CXU-board modifyRedundancyInterlinksFeature: applicable only for CXU-board |
| SHE shePhysBrdControlStatus | 1.3.6.1.4.1.231.7.1.2.2.1.1.4.1.2 | SheControlStatusType | read-only | The status of the control request. |
| SHE shePhysBrdControlReqResult | 1.3.6.1.4.1.231.7.1.2.2.1.1.4.1.3 | ShePhysBrdControlRequestResultType | read-only | The result of the last user command. |
| U32 shePhysBrdControlTimeStamp | 1.3.6.1.4.1.231.7.1.2.2.1.1.4.1.4 | Unsigned32 | read-only | The time stamp of the last command (end of command). |
| U32 shePhysBrdControlTimer | 1.3.6.1.4.1.231.7.1.2.2.1.1.4.1.5 | Unsigned32 | read-only | The maximum wait time for the manager for a line redundancy user command. |
| PHY shePhysBrdControlEntPhysicalIndex | 1.3.6.1.4.1.231.7.1.2.2.1.1.4.1.6 | PhysicalIndex | read-write | The entPhysicalIndex of the card to be switched over or modified. |
| SHE shePhysBrdControlRedundancyFeature | 1.3.6.1.4.1.231.7.1.2.2.1.1.4.1.7 | ShePhysRedundancyFeatureType | read-write | Only applicable for CXU-board. |
| NUM shePhysBrdControlRedundancyInterlink | 1.3.6.1.4.1.231.7.1.2.2.1.1.4.1.8 | ShePhysRedundancyInterlinkType | read-write | Configure a medium type for connecting interlink ports on board redundancy. |
| shePhysRedundancyBase | 1.3.6.1.4.1.231.7.1.2.2.1.1.4.2 | |||
| SHE shePhysRedundancyFeature | 1.3.6.1.4.1.231.7.1.2.2.1.1.4.2.1 | ShePhysRedundancyFeatureType | read-only | Configure special features they are importend for redundancy handling. |
| NUM shePhysRedundancyInterlink | 1.3.6.1.4.1.231.7.1.2.2.1.1.4.2.2 | ShePhysRedundancyInterlinkType | read-only | Configure a medium type for connecting interlink ports on board redundancy. |
| shePhysicalNotifications | 1.3.6.1.4.1.231.7.1.2.2.1.1.5 | |||
| shePhysRackEvents | 1.3.6.1.4.1.231.7.1.2.2.1.1.5.1 | |||
| NTF shePhysRackControlResult | 1.3.6.1.4.1.231.7.1.2.2.1.1.5.1.1 | Notification of rack command ending and result. | ||
| shePhysRackAlarms | 1.3.6.1.4.1.231.7.1.2.2.1.1.5.2 | |||
| NTF shePhysDCAlarm0 | 1.3.6.1.4.1.231.7.1.2.2.1.1.5.2.1 | Break down of power supply fan group 0 . | ||
| NTF shePhysDCAlarm1 | 1.3.6.1.4.1.231.7.1.2.2.1.1.5.2.2 | Break down of power supply fan group 1 . | ||
| NTF shePhysFanAlarm0 | 1.3.6.1.4.1.231.7.1.2.2.1.1.5.2.3 | Depending on used shelftype the alarm stand for: M400, M600, M1200, MDUS: -> Alarm for Fan 0. G100 G200 G400, G600, M1100, G1100: -> Fan control defective. | ||
| NTF shePhysFanAlarm1 | 1.3.6.1.4.1.231.7.1.2.2.1.1.5.2.4 | Depending on used shelftype the alarm stand for: M400, M600, M1200, MDUS: -> Alarm for Fan 1. G100 G200 G400, G600, M1100, G1100: -> Fan defective (Sum alarm). | ||
| NTF shePhysFanAlarm2 | 1.3.6.1.4.1.231.7.1.2.2.1.1.5.2.5 | Depending on used shelftype the alarm stand for: M400, M600, M1200: -> Alarm for Fan 2. G100 G200 G400, G600, M1100, G1100: -> Filter pad must be cleaned. MDUS: -> not used. | ||
| NTF shePhysFanAlarm3 | 1.3.6.1.4.1.231.7.1.2.2.1.1.5.2.6 | Depending on used shelftype the alarm stand for: M400, M600, M1200: -> Alarm for Fan 3. G100 G200 G400, G600, M1100, G1100, MDUS: -> not used | ||
| NTF shePhysFanAlarm4 | 1.3.6.1.4.1.231.7.1.2.2.1.1.5.2.7 | Depending on used shelftype the alarm stand for: M400, M600, M1200: -> Alarm for Fan 4 (if equiped). G100 G200 G400, G600, M1100, G1100, MDUS: -> not used | ||
| NTF shePhysFanAlarm5 | 1.3.6.1.4.1.231.7.1.2.2.1.1.5.2.8 | Depending on used shelftype the alarm stand for: M400, M600, M1200: -> Alarm for Fan 4 (if equiped). G100 G200 G400, G600, M1100, G1100, MDUS: -> not used | ||
| shePhysShelfEvents | 1.3.6.1.4.1.231.7.1.2.2.1.1.5.3 | |||
| NTF shePhysShelfControlResult | 1.3.6.1.4.1.231.7.1.2.2.1.1.5.3.1 | Notification of chassis command ending and result. | ||
| NTF shePhysShelfControlExternalAlarmsConfigurationChanged | 1.3.6.1.4.1.231.7.1.2.2.1.1.5.3.2 | External alarm configuration changed. | ||
| NTF shePhysShelfControlRelativeHumidityAlarmThresholdChanged | 1.3.6.1.4.1.231.7.1.2.2.1.1.5.3.3 | Alarm threshold configuration changed. | ||
| NTF shePhysShelfBatteryBackupModified | 1.3.6.1.4.1.231.7.1.2.2.1.1.5.3.4 | Could only occur in shelf SHE hiX5622 R1.0 -> MDUS:E, if battery backupMode was modified. | ||
| NTF shePhysShelfControlExternalAlarmsOutputStatusChanged | 1.3.6.1.4.1.231.7.1.2.2.1.1.5.3.5 | External alarm output status configuration changed. | ||
| shePhysShelfAlarms | 1.3.6.1.4.1.231.7.1.2.2.1.1.5.4 | |||
| NTF shePhysShelfMupState1 | 1.3.6.1.4.1.231.7.1.2.2.1.1.5.4.1 | Break down of redundancy power supply 1 ( Power Supply or battery ). Note: This alarm will never occur in case of used shelftype G400R/G600:R:E with plugged PM_R module. | ||
| NTF shePhysShelfMupState2 | 1.3.6.1.4.1.231.7.1.2.2.1.1.5.4.2 | Break down of redundancy power supply 2 ( Power Supply or battery ). Note: This alarm will never occur in case of used shelftype G400R/G600:R:E with plugged PM_R module. | ||
| NTF shePhysShelfExternalAlarm01 | 1.3.6.1.4.1.231.7.1.2.2.1.1.5.4.3 | External Alarm 01. Default usage in hix5622 R1.0 system (shelftyp MDUS:E): AC Failure -> Powering Alarm - Loss of external power. | ||
| NTF shePhysShelfExternalAlarm02 | 1.3.6.1.4.1.231.7.1.2.2.1.1.5.4.4 | External Alarm 2. Default usage in hix5622 R1.0 system (shelftyp MDUS:E): DC Failure (internal fault) -> Equipment Alarm - A functional failure on an internal interface. | ||
| NTF shePhysShelfExternalAlarm03 | 1.3.6.1.4.1.231.7.1.2.2.1.1.5.4.5 | External Alarm 3. Default usage in hix5622 system R1.0 (shelftyp MDUS:E): Deep battery discharge -> Battery Low - battery is provisioned and present but voltage is too low. | ||
| NTF shePhysShelfExternalAlarm04 | 1.3.6.1.4.1.231.7.1.2.2.1.1.5.4.6 | External Alarm 4. Default usage in hix5622 R1.0 system (shelftyp MDUS:E): Battery missing -> Battery is provisioned but missing. | ||
| NTF shePhysShelfExternalAlarm05 | 1.3.6.1.4.1.231.7.1.2.2.1.1.5.4.7 | External Alarm 5. Default usage in hix5622 R1.0 system (shelftyp MDUS:E): Battery replace (end of life) -> Battery Failure - Battery is provisioned and present but cannot recharge. | ||
| NTF shePhysShelfExternalAlarm06 | 1.3.6.1.4.1.231.7.1.2.2.1.1.5.4.8 | External Alarm 6. Default usage in hix5622 R1.0 system (shelftyp MDUS:E): Door Contact -> Physical Intrusion alarm. | ||
| NTF shePhysShelfExternalAlarm07 | 1.3.6.1.4.1.231.7.1.2.2.1.1.5.4.9 | External Alarm 7. | ||
| NTF shePhysShelfExternalAlarm08 | 1.3.6.1.4.1.231.7.1.2.2.1.1.5.4.10 | External Alarm 8. | ||
| NTF shePhysShelfRelativeHumidityAlarm | 1.3.6.1.4.1.231.7.1.2.2.1.1.5.4.11 | The configured threshold for relative humidity was reached. | ||
| NTF shePhysShelfHeatExchangerIn | 1.3.6.1.4.1.231.7.1.2.2.1.1.5.4.12 | Break down of 1 or more fan of the heat exchanger inner circle. Note: This alarm could only occur in case of used shelftype G400R/G600:R:E with plugged PM_R module. | ||
| NTF shePhysShelfHeatExchangerOut | 1.3.6.1.4.1.231.7.1.2.2.1.1.5.4.13 | Break down of 1 or more fan of the heat exchanger outer circle. Note: This alarm could only occur in case of used shelftype G400R/G600:R:E with plugged PM_R module. | ||
| NTF shePhysShelfExtAlarmCollectorNotConnected | 1.3.6.1.4.1.231.7.1.2.2.1.1.5.4.14 | External Alarm Collector is not connected. The detection of external Alarms is not possible. Only valid if powermodule PM:ONU:2G:E is used. | ||
| shePhysCardEvents | 1.3.6.1.4.1.231.7.1.2.2.1.1.5.5 | |||
| NTF shePhysCardControlResult | 1.3.6.1.4.1.231.7.1.2.2.1.1.5.5.1 | Notification sent end of a long running card command. | ||
| NTF shePhysCardAdminStateChanged | 1.3.6.1.4.1.231.7.1.2.2.1.1.5.5.2 | The cards adminState changed. | ||
| NTF shePhysCardStateChanged | 1.3.6.1.4.1.231.7.1.2.2.1.1.5.5.3 | The cards operational/availabilty state changed. | ||
| NTF shePhysCardReset | 1.3.6.1.4.1.231.7.1.2.2.1.1.5.5.4 | Card is performing a reset. | ||
| NTF shePhysCardResetEnd | 1.3.6.1.4.1.231.7.1.2.2.1.1.5.5.5 | End of card reset. | ||
| NTF shePhysCardCreated | 1.3.6.1.4.1.231.7.1.2.2.1.1.5.5.6 | Card created. | ||
| NTF shePhysCardDeleted | 1.3.6.1.4.1.231.7.1.2.2.1.1.5.5.7 | Card deleted. | ||
| NTF shePhysCardDeletionStarted | 1.3.6.1.4.1.231.7.1.2.2.1.1.5.5.8 | The card deletion procedure in the NE was started. | ||
| NTF shePhysContainerCardTypeConverted | 1.3.6.1.4.1.231.7.1.2.2.1.1.5.5.9 | Card type converted. | ||
| NTF shePhysCardConvertionStarted | 1.3.6.1.4.1.231.7.1.2.2.1.1.5.5.10 | The card convertion procedure in the NE was started. | ||
| NTF shePhysCardPlugged | 1.3.6.1.4.1.231.7.1.2.2.1.1.5.5.11 | A card was plugged. This notification contains a list of two entPhysicalIndices. First is the entPhysicalIndex of the slot, were these module was plugged and the second, the entPhysicalIndex of the card itself. | ||
| NTF shePhysCardUnplugged | 1.3.6.1.4.1.231.7.1.2.2.1.1.5.5.12 | A card was unplugged. This notification contains a list of two entPhysicalIndices. First is the entPhysicalIndex of the slot, were these module was plugged before and the second, the entPhysicalIndex of the card itself. | ||
| NTF shePhysCardChangedTemperatureThreshold | 1.3.6.1.4.1.231.7.1.2.2.1.1.5.5.13 | The temperature threshold has been configured. THIS ELEMENT WILL NOT LONGER BE SUPPORTED BY NE up R2.5. | ||
| NTF shePhysCardTemperatureWarningThresholdsChanged | 1.3.6.1.4.1.231.7.1.2.2.1.1.5.5.14 | Configuration event. | ||
| shePhysCardAlarms | 1.3.6.1.4.1.231.7.1.2.2.1.1.5.6 | |||
| NTF shePhysCardTypeMismatch | 1.3.6.1.4.1.231.7.1.2.2.1.1.5.6.1 | Wrong card is plugged. | ||
| NTF shePhysCardFailure | 1.3.6.1.4.1.231.7.1.2.2.1.1.5.6.2 | Card out of service. | ||
| NTF shePhysCardProblem | 1.3.6.1.4.1.231.7.1.2.2.1.1.5.6.3 | Card partly out of service. | ||
| NTF shePhysCardNotInstalled | 1.3.6.1.4.1.231.7.1.2.2.1.1.5.6.4 | Card not plugged. | ||
| NTF shePhysCardTemperaturePowerDown | 1.3.6.1.4.1.231.7.1.2.2.1.1.5.6.5 | Temperature alarm. The IU has detect high temperature and start's first action to reduce power consumption. | ||
| NTF shePhysCardOverTemperatureReset | 1.3.6.1.4.1.231.7.1.2.2.1.1.5.6.6 | CXU has forced IU-Card to reset because of over temperature. | ||
| NTF shePhysCardOverTemperatureThreshold | 1.3.6.1.4.1.231.7.1.2.2.1.1.5.6.7 | Card temperature Threshold alarm. THIS ELEMENT WILL NOT LONGER BE SUPPORTED BY NE up R2.5. | ||
| NTF shePhysCardTemperatureWarning | 1.3.6.1.4.1.231.7.1.2.2.1.1.5.6.8 | Temperature warning alarm. The CXU has detected a higher temperature then the configured value. | ||
| NTF shePhysCardSWVersionProblem | 1.3.6.1.4.1.231.7.1.2.2.1.1.5.6.9 | Card out of service due to wrong SW version. Please upgrade! | ||
| shePhysPortEvents | 1.3.6.1.4.1.231.7.1.2.2.1.1.5.7 | |||
| NTF shePhysPortAdminStateChanged | 1.3.6.1.4.1.231.7.1.2.2.1.1.5.7.1 | The ports adminState changed. Could be send as a collection trap. That means, this notification could contain more then one indexed ifAdminState. During system startup normaly a large number of notifications are needed. In such a case, it is possible to send only one notification per card which contain the ifAdminStates of all port's. | ||
| NTF shePhysPortOperStateChanged | 1.3.6.1.4.1.231.7.1.2.2.1.1.5.7.2 | The ports operational state changed. Could be send as a collection trap. That means, this notification could contain more then one indexed ifOperState. During system startup normaly a large number of notifications are needed. In such a case, it is possible to send only one notification per card which contain the ifOperStates of all port's. | ||
| NTF shePhysPortControlResult | 1.3.6.1.4.1.231.7.1.2.2.1.1.5.7.3 | Notification of port command ending and result. | ||
| NTF shePhysPortCreated | 1.3.6.1.4.1.231.7.1.2.2.1.1.5.7.4 | Notification about port creation. Could be send as a collection trap. That means, this notification could contain more then one ifIndex. In case of a card creation sequence, normaly a large number of PortCreated-notifications are needed. In such a case, it is possible to send only one notification which contain the ifIndeces of all created port's for the entPhysicalIndex of this new card. | ||
| NTF shePhysPortDeleted | 1.3.6.1.4.1.231.7.1.2.2.1.1.5.7.5 | Notification about the succesfull delete of a port. Could be send as a collection trap. That means, this notification could contain more then one ifIndex. In case of a card deletion sequence, normaly a large number of PortDeleted-notifications are needed. In such a case, it is possible to send only one notification which contain the ifIndeces of all deleted port's for the entPhysicalIndex of this card. | ||
| shePhysPortAlarms | 1.3.6.1.4.1.231.7.1.2.2.1.1.5.8 | |||
| NTF shePhysPortOperStateDown | 1.3.6.1.4.1.231.7.1.2.2.1.1.5.8.1 | This is a operstate-down alarm trap. This trap could not be send as collection trap (different from OperStateChanged - Event trap)!! This trap could be blocked by setting in alarmseverity-profile. | ||
| shePhysRedundancyEvents | 1.3.6.1.4.1.231.7.1.2.2.1.1.5.9 | |||
| NTF shePhysBrdControlResult | 1.3.6.1.4.1.231.7.1.2.2.1.1.5.9.1 | Notification of board redundancy command ending and result. | ||
| NTF shePhysRedundancyStateChanged | 1.3.6.1.4.1.231.7.1.2.2.1.1.5.9.2 | Notification of change of redundancy ralated attributes of a card. | ||
| NTF shePhysRedundancyFeatureModified | 1.3.6.1.4.1.231.7.1.2.2.1.1.5.9.3 | Modification response trap. | ||
| NTF shePhysRedundancyInterlinkModified | 1.3.6.1.4.1.231.7.1.2.2.1.1.5.9.4 | The medium type for interlink has been changed. | ||
| shePhysRedundancyAlarms | 1.3.6.1.4.1.231.7.1.2.2.1.1.5.10 | |||
| NTF shePhysRedundancyNoRedundancy | 1.3.6.1.4.1.231.7.1.2.2.1.1.5.10.1 | Redundancy is not available for a card. | ||
| shePhysRackObjects | 1.3.6.1.4.1.231.7.1.2.2.1.1.6 | |||
| shePhysRackTable | 1.3.6.1.4.1.231.7.1.2.2.1.1.6.1 | not-accessible | The shelf/chassis table. | |
| shePhysRackEntry | 1.3.6.1.4.1.231.7.1.2.2.1.1.6.1.1 | not-accessible | Entry of the rack table. The entries represent the SHE rack. | |
| SHE shePhysRackAlarmSeverityIndex | 1.3.6.1.4.1.231.7.1.2.2.1.1.6.1.1.1 | SheAlarmSevProfileIndex | read-only | A pointer to the instance of the alarm severity profile that contains the severity assignments for alarms reported by this managed entity. Default is 1. |
| shePhysRackControl | 1.3.6.1.4.1.231.7.1.2.2.1.1.6.2 | |||
| SHE shePhysRackControlRequest | 1.3.6.1.4.1.231.7.1.2.2.1.1.6.2.1 | ShePhysControlRequestType | read-write | The rack commands : changeAlarmSeverityProfile: the alarm severity profile of the rack is changed. Notifications : shePhysRackControlResult at the command ending in case of long running command. |
| SHE shePhysRackControlStatus | 1.3.6.1.4.1.231.7.1.2.2.1.1.6.2.2 | SheControlStatusType | read-only | The status of a user command. |
| PHY shePhysRackControlIndex | 1.3.6.1.4.1.231.7.1.2.2.1.1.6.2.3 | PhysicalIndex | read-write | The entPhysicalIndex of the rack. |
| SHE shePhysRackControlAlarmSeverityIndex | 1.3.6.1.4.1.231.7.1.2.2.1.1.6.2.4 | SheAlarmSevProfileIndex | read-write | The new AlarmSeverityIndex of the alarm severity profile assigned to the rack. |
| U32 shePhysRackControlTimeStamp | 1.3.6.1.4.1.231.7.1.2.2.1.1.6.2.5 | Unsigned32 | read-only | The time stamp of the last command (end of command). |
| U32 shePhysRackControlTimer | 1.3.6.1.4.1.231.7.1.2.2.1.1.6.2.6 | Unsigned32 | read-only | The maximum wait time for the manager for command ending in case of long running user commands. The manager reads this value from the PPE SHE. The end of request indicates the trap ShePhysResult . |
| SHE shePhysRackControlReqResult | 1.3.6.1.4.1.231.7.1.2.2.1.1.6.2.7 | ShePhysControlRequestResultType | read-only | The result of the last user command. |
| shePhysShelfObjects | 1.3.6.1.4.1.231.7.1.2.2.1.1.7 | |||
| shePhysShelfTable | 1.3.6.1.4.1.231.7.1.2.2.1.1.7.1 | not-accessible | The shelf/chassis table. | |
| shePhysShelfEntry | 1.3.6.1.4.1.231.7.1.2.2.1.1.7.1.1 | not-accessible | Entry of the chassis table. The entries represent the SHE shelf(s). | |
| SHE shePhysShelfAlarmSeverityIndex | 1.3.6.1.4.1.231.7.1.2.2.1.1.7.1.1.1 | SheAlarmSevProfileIndex | read-only | A pointer to the instance of the alarm severity profile that contains the severity assignments for alarms reported by this managed entity. Default is 1. |
| STR shePhysShelfTypeCode | 1.3.6.1.4.1.231.7.1.2.2.1.1.7.1.1.2 | DisplayString | read-only | Contains the typecode for the possible used She-Shelf's. Depending on the detected shelftype-code the corresponding system version will be displayed. Systemversion -> Shelftypes SHE hiX5635 -> M1200:E, M1100:E, G1100:E, G1100:A, G1100:B:E SHE hiX5630 -> M600:E, G600:E, G600:R:E, M600:DF:E SHE hiX5625 -> M400:E, G400:E, G400:R:A, SHE hiX5622 R1.0 -> MDUS:E (obsolete because release was canceled) SHE hiX5608 -> 'empty' string because no shelf is used, single box system Shelftype's 2 generation - only new 2G powermodules could be used! (>= with R2.8 maintenance) SHE hiX5635 -> G1100:2G:E, M1100:2G:E SHE hiX5630 -> G600:2G:E, G600:R:2G:E, SHE hiX5625 -> G400:2G:E, G400:R:2G:E, SHE hiX5622 -> G200:2G:E, G200S:2G:E |
| SHE shePhysShelfExternalAlarmOutput01Status | 1.3.6.1.4.1.231.7.1.2.2.1.1.7.1.1.3 | ShePhysShelfExternalAlarmOutputStatusType | read-only | Status of the external alarm output 01. |
| OCT shePhysShelfExternalAlarmOutput01Usage | 1.3.6.1.4.1.231.7.1.2.2.1.1.7.1.1.4 | OCTET STRING | read-only | Description for usage of this external alarm output. Only for managment interface and no special meaning for the NE. |
| SHE shePhysShelfExternalAlarmOutput02Status | 1.3.6.1.4.1.231.7.1.2.2.1.1.7.1.1.5 | ShePhysShelfExternalAlarmOutputStatusType | read-only | Status of the external alarm output 02. |
| OCT shePhysShelfExternalAlarmOutput02Usage | 1.3.6.1.4.1.231.7.1.2.2.1.1.7.1.1.6 | OCTET STRING | read-only | Description for usage of this external alarm output. Only for managment interface and no special meaning for the NE. |
| SHE shePhysShelfExternalAlarmOutput03Status | 1.3.6.1.4.1.231.7.1.2.2.1.1.7.1.1.7 | ShePhysShelfExternalAlarmOutputStatusType | read-only | Status of the external alarm output 03. |
| OCT shePhysShelfExternalAlarmOutput03Usage | 1.3.6.1.4.1.231.7.1.2.2.1.1.7.1.1.8 | OCTET STRING | read-only | Description for usage of this external alarm output. Only for managment interface and no special meaning for the NE. |
| SHE shePhysShelfExternalAlarm01Level | 1.3.6.1.4.1.231.7.1.2.2.1.1.7.1.1.9 | ShePhysShelfExternalAlarmLevelType | read-only | Configured level for active alarm. |
| OCT shePhysShelfExternalAlarm01Usage | 1.3.6.1.4.1.231.7.1.2.2.1.1.7.1.1.10 | OCTET STRING | read-only | Description for usage of this external alarm. Only for managment interface and no special meaning for the NE. Default usage in hiX5622 R1.0 system (shelftyp MDUS:E): AC Failure -> Powering Alarm - Loss of external power Default usage in hiX5608 R1.0 system: Door Contact -> Physical Intrusion alarm. |
| SHE shePhysShelfExternalAlarm02Level | 1.3.6.1.4.1.231.7.1.2.2.1.1.7.1.1.11 | ShePhysShelfExternalAlarmLevelType | read-only | Configured level for active alarm. |
| OCT shePhysShelfExternalAlarm02Usage | 1.3.6.1.4.1.231.7.1.2.2.1.1.7.1.1.12 | OCTET STRING | read-only | Description for usage of this external alarm. Only for managment interface and no special meaning for the NE. Default usage in hix5622 R1.0 system (shelftyp MDUS:E): DC Failure (internal fault) -> Equipment Alarm - A functional failure on an internal interface. |
| SHE shePhysShelfExternalAlarm03Level | 1.3.6.1.4.1.231.7.1.2.2.1.1.7.1.1.13 | ShePhysShelfExternalAlarmLevelType | read-only | Configured level for active alarm. |
| OCT shePhysShelfExternalAlarm03Usage | 1.3.6.1.4.1.231.7.1.2.2.1.1.7.1.1.14 | OCTET STRING | read-only | Description for usage of this external alarm. Only for managment interface and no special meaning for the NE. Default usage in hix5622 R1.0 system (shelftyp MDUS:E): Deep battery discharge -> Battery Low - battery is provisioned and present but voltage is too low. |
| SHE shePhysShelfExternalAlarm04Level | 1.3.6.1.4.1.231.7.1.2.2.1.1.7.1.1.15 | ShePhysShelfExternalAlarmLevelType | read-only | Configured level for active alarm. |
| OCT shePhysShelfExternalAlarm04Usage | 1.3.6.1.4.1.231.7.1.2.2.1.1.7.1.1.16 | OCTET STRING | read-only | Description for usage of this external alarm. Only for managment interface and no special meaning for the NE. Default usage in hix5622 R1.0 system (shelftyp MDUS:E): Battery missing -> Battery is provisioned but missing. |
| SHE shePhysShelfExternalAlarm05Level | 1.3.6.1.4.1.231.7.1.2.2.1.1.7.1.1.17 | ShePhysShelfExternalAlarmLevelType | read-only | Configured level for active alarm. |
| OCT shePhysShelfExternalAlarm05Usage | 1.3.6.1.4.1.231.7.1.2.2.1.1.7.1.1.18 | OCTET STRING | read-only | Description for usage of this external alarm. Only for managment interface and no special meaning for the NE. Default usage in hix5622 R1.0 system (shelftyp MDUS:E): Battery replace (end of life) -> Battery Failure - Battery is provisioned and present but cannot recharge. |
| SHE shePhysShelfExternalAlarm06Level | 1.3.6.1.4.1.231.7.1.2.2.1.1.7.1.1.19 | ShePhysShelfExternalAlarmLevelType | read-only | Configured level for active alarm. |
| OCT shePhysShelfExternalAlarm06Usage | 1.3.6.1.4.1.231.7.1.2.2.1.1.7.1.1.20 | OCTET STRING | read-only | Description for usage of this external alarm. Only for managment interface and no special meaning for the NE. Default usage in hix5622 R1.0 system (shelftyp MDUS:E): Door Contact -> Physical Intrusion alarm. |
| SHE shePhysShelfExternalAlarm07Level | 1.3.6.1.4.1.231.7.1.2.2.1.1.7.1.1.21 | ShePhysShelfExternalAlarmLevelType | read-only | Configured level for active alarm. |
| OCT shePhysShelfExternalAlarm07Usage | 1.3.6.1.4.1.231.7.1.2.2.1.1.7.1.1.22 | OCTET STRING | read-only | Description for usage of this external alarm. Only for managment interface and no special meaning for the NE. |
| SHE shePhysShelfExternalAlarm08Level | 1.3.6.1.4.1.231.7.1.2.2.1.1.7.1.1.23 | ShePhysShelfExternalAlarmLevelType | read-only | Configured level for active alarm. |
| OCT shePhysShelfExternalAlarm08Usage | 1.3.6.1.4.1.231.7.1.2.2.1.1.7.1.1.24 | OCTET STRING | read-only | Description for usage of this external alarm. Only for managment interface and no special meaning for the NE. |
| U32 shePhysShelfRelativeHumidity | 1.3.6.1.4.1.231.7.1.2.2.1.1.7.1.1.25 | Unsigned32 | read-only | Environmentale parameter for relative humidity in %. This parameter is only valid for shelftype G400R//G600:R:E with powermodule PM_R is plugged and optional humidity sensor is available. In all other cases the value 255 will report, that a valid measurement result is not available. |
| U32 shePhysShelfRelativeHumidityAlarmOn | 1.3.6.1.4.1.231.7.1.2.2.1.1.7.1.1.26 | Unsigned32 | read-only | Environmentale parameter for relative humidity alarm threshold on. This parameter is only valid for shelftype G400R/G600:R:E with powermodule PM_R is plugged and optional humidity sensor is available. |
| U32 shePhysShelfRelativeHumidityAlarmOff | 1.3.6.1.4.1.231.7.1.2.2.1.1.7.1.1.27 | Unsigned32 | read-only | Environmentale parameter for relative humidity alarm threshold off. This parameter is only valid for shelftype G400R/G600:R:E with powermodule PM_R is plugged and optional humidity sensor is available. |
| T/F shePhysShelfBatteryBackupOption | 1.3.6.1.4.1.231.7.1.2.2.1.1.7.1.1.28 | TruthValue | read-only | Indication wether the SHE supports battery backup. Only shelftype SHE hiX5622 R1.0 -> MDUS:E will support battery backup, otherwise false. |
| T/F shePhysShelfBatteryBackupMode | 1.3.6.1.4.1.231.7.1.2.2.1.1.7.1.1.29 | TruthValue | read-only | Indication wether battery backup is provisioned. Only valid for shelftype SHE hiX5622 R1.0 -> MDUS:E. |
| shePhysShelfControl | 1.3.6.1.4.1.231.7.1.2.2.1.1.7.2 | |||
| SHE shePhysShelfControlRequest | 1.3.6.1.4.1.231.7.1.2.2.1.1.7.2.1 | ShePhysControlRequestType | read-write | The chassis commands : changeAlarmSeverityProfile: the alarm severity profile of the chassis is changed. changeShelfExternalAlarmSettings change level for active external alarms and set a descriptional name for usage Notifications : shePhysShelfControlExternalAlarmsConfigurationChanged shePhysShelfControlResult at the command ending in case of long running command. changeShelfRelativeHumidityAlarmThreshold change the alarm threshold configuration for environmental parameter relative humidity Notifications: shePhysShelfControlRelativeHumidityAlarmThresholdChanged hiX5622 R1.0 only: changeShelfBatteryBackupMode: shePhysShelfControlBatteryBackupMode Notifications: shePhysShelfBatteryBackupModified New with R2.8: changeShelfExternalAlarmOutputStatus change status external alarm outputs Notifications : shePhysShelfControlExternalAlarmsOutputStatusChanged |
| SHE shePhysShelfControlStatus | 1.3.6.1.4.1.231.7.1.2.2.1.1.7.2.2 | SheControlStatusType | read-only | The status of a user command. |
| PHY shePhysShelfControlIndex | 1.3.6.1.4.1.231.7.1.2.2.1.1.7.2.3 | PhysicalIndex | read-write | The entPhysicalIndex of the shelf. |
| U32 shePhysShelfControlTimeStamp | 1.3.6.1.4.1.231.7.1.2.2.1.1.7.2.4 | Unsigned32 | read-only | The time stamp of the last command (end of command). |
| U32 shePhysShelfControlTimer | 1.3.6.1.4.1.231.7.1.2.2.1.1.7.2.5 | Unsigned32 | read-only | The maximum wait time for the manager for command ending in case of long running user commands. The manager reads this value from the PPE SHE. The end of request indicates the trap ShePhysRiResult . |
| SHE shePhysShelfControlReqResult | 1.3.6.1.4.1.231.7.1.2.2.1.1.7.2.6 | ShePhysControlRequestResultType | read-only | The result of the last user command. |
| SHE shePhysShelfControlAlarmSeverityIndex | 1.3.6.1.4.1.231.7.1.2.2.1.1.7.2.7 | SheAlarmSevProfileIndex | read-write | The new AlarmSeverityIndex of the alarm severity profile assigned to the chassis. |
| OCT shePhysShelfControlExternalAlarmOutput01Usage | 1.3.6.1.4.1.231.7.1.2.2.1.1.7.2.8 | OCTET STRING | read-write | Description for usage of this external alarm output. Only for managment interface and no special meaning for the NE. |
| OCT shePhysShelfControlExternalAlarmOutput02Usage | 1.3.6.1.4.1.231.7.1.2.2.1.1.7.2.9 | OCTET STRING | read-write | Description for usage of this external alarm output. Only for managment interface and no special meaning for the NE. |
| OCT shePhysShelfControlExternalAlarmOutput03Usage | 1.3.6.1.4.1.231.7.1.2.2.1.1.7.2.10 | OCTET STRING | read-write | Description for usage of this external alarm output. Only for managment interface and no special meaning for the NE. |
| SHE shePhysShelfControlExternalAlarm01Level | 1.3.6.1.4.1.231.7.1.2.2.1.1.7.2.11 | ShePhysShelfExternalAlarmLevelType | read-write | Configured level for active alarm. |
| OCT shePhysShelfControlExternalAlarm01Usage | 1.3.6.1.4.1.231.7.1.2.2.1.1.7.2.12 | OCTET STRING | read-write | Description for usage of this external alarm. Only for managment interface and no special meaning for the NE. |
| SHE shePhysShelfControlExternalAlarm02Level | 1.3.6.1.4.1.231.7.1.2.2.1.1.7.2.13 | ShePhysShelfExternalAlarmLevelType | read-write | Configured level for active alarm. |
| OCT shePhysShelfControlExternalAlarm02Usage | 1.3.6.1.4.1.231.7.1.2.2.1.1.7.2.14 | OCTET STRING | read-write | Description for usage of this external alarm. Only for managment interface and no special meaning for the NE. |
| SHE shePhysShelfControlExternalAlarm03Level | 1.3.6.1.4.1.231.7.1.2.2.1.1.7.2.15 | ShePhysShelfExternalAlarmLevelType | read-write | Configured level for active alarm. |
| OCT shePhysShelfControlExternalAlarm03Usage | 1.3.6.1.4.1.231.7.1.2.2.1.1.7.2.16 | OCTET STRING | read-write | Description for usage of this external alarm. Only for managment interface and no special meaning for the NE. |
| SHE shePhysShelfControlExternalAlarm04Level | 1.3.6.1.4.1.231.7.1.2.2.1.1.7.2.17 | ShePhysShelfExternalAlarmLevelType | read-write | Configured level for active alarm. |
| OCT shePhysShelfControlExternalAlarm04Usage | 1.3.6.1.4.1.231.7.1.2.2.1.1.7.2.18 | OCTET STRING | read-write | Description for usage of this external alarm. Only for managment interface and no special meaning for the NE. |
| SHE shePhysShelfControlExternalAlarm05Level | 1.3.6.1.4.1.231.7.1.2.2.1.1.7.2.19 | ShePhysShelfExternalAlarmLevelType | read-write | Configured level for active alarm. |
| OCT shePhysShelfControlExternalAlarm05Usage | 1.3.6.1.4.1.231.7.1.2.2.1.1.7.2.20 | OCTET STRING | read-write | Description for usage of this external alarm. Only for managment interface and no special meaning for the NE. |
| SHE shePhysShelfControlExternalAlarm06Level | 1.3.6.1.4.1.231.7.1.2.2.1.1.7.2.21 | ShePhysShelfExternalAlarmLevelType | read-write | Configured level for active alarm. |
| OCT shePhysShelfControlExternalAlarm06Usage | 1.3.6.1.4.1.231.7.1.2.2.1.1.7.2.22 | OCTET STRING | read-write | Description for usage of this external alarm. Only for managment interface and no special meaning for the NE. |
| SHE shePhysShelfControlExternalAlarm07Level | 1.3.6.1.4.1.231.7.1.2.2.1.1.7.2.23 | ShePhysShelfExternalAlarmLevelType | read-write | Configured level for active alarm. |
| OCT shePhysShelfControlExternalAlarm07Usage | 1.3.6.1.4.1.231.7.1.2.2.1.1.7.2.24 | OCTET STRING | read-write | Description for usage of this external alarm. Only for managment interface and no special meaning for the NE. |
| SHE shePhysShelfControlExternalAlarm08Level | 1.3.6.1.4.1.231.7.1.2.2.1.1.7.2.25 | ShePhysShelfExternalAlarmLevelType | read-write | Configured level for active alarm. |
| OCT shePhysShelfControlExternalAlarm08Usage | 1.3.6.1.4.1.231.7.1.2.2.1.1.7.2.26 | OCTET STRING | read-write | Description for usage of this external alarm. Only for managment interface and no special meaning for the NE. |
| U32 shePhysShelfControlRelativeHumidityAlarmOn | 1.3.6.1.4.1.231.7.1.2.2.1.1.7.2.27 | Unsigned32 | read-write | Configure the environmentale parameter for relative humidity alarm threshold on. This parameter is only valid for shelftype G400R/G600:R:E with powermodule PM_R is plugged and optional humidity sensor is available. |
| U32 shePhysShelfControlRelativeHumidityAlarmOff | 1.3.6.1.4.1.231.7.1.2.2.1.1.7.2.28 | Unsigned32 | read-write | Configure the environmentale parameter for relative humidity alarm threshold off. This parameter is only valid for shelftype G400R/G600:R:E with powermodule PM_R is plugged and optional humidity sensor is available. |
| T/F shePhysShelfControlBatteryBackupMode | 1.3.6.1.4.1.231.7.1.2.2.1.1.7.2.29 | TruthValue | read-write | Provisioning of battery backup. Only valid for shelftype SHE hiX5622 R1.0 -> MDUS:E. |
| SHE shePhysShelfControlExternalAlarmOutput01Status | 1.3.6.1.4.1.231.7.1.2.2.1.1.7.2.30 | ShePhysShelfExternalAlarmOutputStatusType | read-write | Set the status of the external alarm output 01. |
| SHE shePhysShelfControlExternalAlarmOutput02Status | 1.3.6.1.4.1.231.7.1.2.2.1.1.7.2.31 | ShePhysShelfExternalAlarmOutputStatusType | read-write | Set the status of the external alarm output 02. |
| SHE shePhysShelfControlExternalAlarmOutput03Status | 1.3.6.1.4.1.231.7.1.2.2.1.1.7.2.32 | ShePhysShelfExternalAlarmOutputStatusType | read-write | Set the status of the external alarm output 03. |
| shePhysicalConformance | 1.3.6.1.4.1.231.7.1.2.2.1.1.100 | |||
| shePhysicalGroups | 1.3.6.1.4.1.231.7.1.2.2.1.1.100.1 | |||
| shePhysicalGroup | 1.3.6.1.4.1.231.7.1.2.2.1.1.100.1.1 | Description. | ||
| shePhysicalControlGroup | 1.3.6.1.4.1.231.7.1.2.2.1.1.100.1.2 | Description. | ||
| shePhysicalNotificationGroup | 1.3.6.1.4.1.231.7.1.2.2.1.1.100.1.3 | This group supports notifications of significant conditions associated with physical objects. | ||
| shePhysicalObsoleteGroup | 1.3.6.1.4.1.231.7.1.2.2.1.1.100.1.4 | Description. | ||
| shePhysicalObsoleteNotificationGroup | 1.3.6.1.4.1.231.7.1.2.2.1.1.100.1.5 | Description. | ||
| shePhysicalCompliances | 1.3.6.1.4.1.231.7.1.2.2.1.1.100.2 | |||
| shePhysicalMibCompliance | 1.3.6.1.4.1.231.7.1.2.2.1.1.100.2.1 | The compliance statement for SNMP entities which manage physical interfaces in SHE. |
RFC description
Manages physical entities, chassis components, and module inventory for Nokia Siemens Networks DSLAM equipment.
Start monitoring Nokia Siemens Networks SHE DSLAM chassis (slot/card/port hardware inventory and insertion/removal events) with a free 30-day trial of IPNetwork Monitor. Import MIBs, browse SNMP OIDs, create custom SNMP monitors, configure alerts, and monitor any SNMP-enabled network device from a single console.