SHE-PHYSICAL-MIB :: shePhysShelfTypeCode

MIB Reference — IPNetwork Monitor · Updated October 06, 2026

All MIBs › SHE-PHYSICAL-MIB › shePhysShelfTypeCode

shePhysShelfTypeCode

Module: SHE-PHYSICAL-MIB

OID (symbolic): SHE-PHYSICAL-MIB::shePhysShelfTypeCode

OID (numeric): 1.3.6.1.4.1.231.7.1.2.2.1.1.7.1.1.2

Node type: OBJECT-TYPE

Type: DisplayString

Access: read-only

Description: Contains the typecode for the possible used She-Shelf's. Depending on the detected shelftype-code the corresponding system version will be displayed.

Systemversion -> Shelftypes SHE hiX5635 -> M1200:E, M1100:E, G1100:E, G1100:A, G1100:B:E SHE hiX5630 -> M600:E, G600:E, G600:R:E, M600:DF:E SHE hiX5625 -> M400:E, G400:E, G400:R:A, SHE hiX5622 R1.0 -> MDUS:E (obsolete because release was canceled) SHE hiX5608 -> 'empty' string because no shelf is used, single box system

Shelftype's 2 generation - only new 2G powermodules could be used! (>= with R2.8 maintenance) SHE hiX5635 -> G1100:2G:E, M1100:2G:E SHE hiX5630 -> G600:2G:E, G600:R:2G:E, SHE hiX5625 -> G400:2G:E, G400:R:2G:E, SHE hiX5622 -> G200:2G:E, G200S:2G:E

What is shePhysShelfTypeCode?

Read-only string identifying which physical SHE shelf model this row describes (e.g. G1100:E, M600:E, or an empty string for a single-box hiX5608 system with no shelf), which in turn determines the overall system version (hiX5635/5630/5625/5622/5608).

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.231.7.1.2.2.1.1.7.1.1.2
snmpwalk -v2c -c public <target> SHE-PHYSICAL-MIB::shePhysShelfTypeCode

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.231.7.1.2.2.1.1.7.1.1.2.1
snmpget -v2c -c public <target> SHE-PHYSICAL-MIB::shePhysShelfTypeCode.1

Start monitoring Nokia Siemens Networks SHE DSLAM chassis (slot/card/port hardware inventory and insertion/removal events) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the SHE-PHYSICAL-MIB::shePhysShelfTypeCode OID value, configure state conditions and alerts, and monitor any Nokia Siemens Networks SHE DSLAM chassis (slot/card/port hardware inventory and insertion/removal events) from a single console.

OID Breakdown

Upper-level ancestors (12 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.231sniAN-MIB
1.3.6.1.4.1.231.7siemensUnitsAN-MIB
1.3.6.1.4.1.231.7.1oenProductMibsAN-MIB
1.3.6.1.4.1.231.7.1.2anAN-MIB
1.3.6.1.4.1.231.7.1.2.2ppeAN-SHE-MIB
1.3.6.1.4.1.231.7.1.2.2.1sheAN-SHE-MIB
Numeric OIDNameModule
1.3.6.1.4.1.231.7.1.2.2.1.1shePhysicalSHE-PHYSICAL-MIB
1.3.6.1.4.1.231.7.1.2.2.1.1.7shePhysShelfObjectsSHE-PHYSICAL-MIB
1.3.6.1.4.1.231.7.1.2.2.1.1.7.1shePhysShelfTableSHE-PHYSICAL-MIB
1.3.6.1.4.1.231.7.1.2.2.1.1.7.1.1shePhysShelfEntrySHE-PHYSICAL-MIB
1.3.6.1.4.1.231.7.1.2.2.1.1.7.1.1.2shePhysShelfTypeCodeSHE-PHYSICAL-MIB