SHE-PHYSICAL-MIB :: shePhysShelfControlRequest

MIB Reference — IPNetwork Monitor · Updated October 06, 2026

All MIBs › SHE-PHYSICAL-MIB › shePhysShelfControlRequest

shePhysShelfControlRequest

Module: SHE-PHYSICAL-MIB

OID (symbolic): SHE-PHYSICAL-MIB::shePhysShelfControlRequest

OID (numeric): 1.3.6.1.4.1.231.7.1.2.2.1.1.7.2.1

Node type: OBJECT-TYPE

Type: ShePhysControlRequestType

Access: read-write

Description: The chassis commands :

changeAlarmSeverityProfile: the alarm severity profile of the chassis is changed.

changeShelfExternalAlarmSettings change level for active external alarms and set a descriptional name for usage Notifications : shePhysShelfControlExternalAlarmsConfigurationChanged shePhysShelfControlResult at the command ending in case of long running command.

changeShelfRelativeHumidityAlarmThreshold change the alarm threshold configuration for environmental parameter relative humidity Notifications: shePhysShelfControlRelativeHumidityAlarmThresholdChanged

hiX5622 R1.0 only: changeShelfBatteryBackupMode: shePhysShelfControlBatteryBackupMode Notifications: shePhysShelfBatteryBackupModified

New with R2.8: changeShelfExternalAlarmOutputStatus change status external alarm outputs Notifications : shePhysShelfControlExternalAlarmsOutputStatusChanged

What is shePhysShelfControlRequest?

Read-write command object for shelf-level actions: changeAlarmSeverityProfile, changeShelfExternalAlarmSettings (adjusts external alarm level/usage text, completion signaled by the shePhysShelfControlExternalAlarmsConfigurationChanged notification), changeShelfRelativeHumidityAlarmThreshold, and, on hiX5622 R1.0 only, changeShelfBatteryBackupMode.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.231.7.1.2.2.1.1.7.2.1
snmpwalk -v2c -c public <target> SHE-PHYSICAL-MIB::shePhysShelfControlRequest

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.231.7.1.2.2.1.1.7.2.1.1
snmpget -v2c -c public <target> SHE-PHYSICAL-MIB::shePhysShelfControlRequest.1

Set instance 1 (SNMPv2c):

snmpset -v2c -c private <target> 1.3.6.1.4.1.231.7.1.2.2.1.1.7.2.1.1 s <value>

Start monitoring Nokia Siemens Networks SHE DSLAM chassis (slot/card/port hardware inventory and insertion/removal events) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the SHE-PHYSICAL-MIB::shePhysShelfControlRequest OID value, configure state conditions and alerts, and monitor any Nokia Siemens Networks SHE DSLAM chassis (slot/card/port hardware inventory and insertion/removal events) from a single console.

OID Breakdown

Upper-level ancestors (12 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.231sniAN-MIB
1.3.6.1.4.1.231.7siemensUnitsAN-MIB
1.3.6.1.4.1.231.7.1oenProductMibsAN-MIB
1.3.6.1.4.1.231.7.1.2anAN-MIB
1.3.6.1.4.1.231.7.1.2.2ppeAN-SHE-MIB
1.3.6.1.4.1.231.7.1.2.2.1sheAN-SHE-MIB
Numeric OIDNameModule
1.3.6.1.4.1.231.7.1.2.2.1.1shePhysicalSHE-PHYSICAL-MIB
1.3.6.1.4.1.231.7.1.2.2.1.1.7shePhysShelfObjectsSHE-PHYSICAL-MIB
1.3.6.1.4.1.231.7.1.2.2.1.1.7.2shePhysShelfControlSHE-PHYSICAL-MIB
1.3.6.1.4.1.231.7.1.2.2.1.1.7.2.1shePhysShelfControlRequestSHE-PHYSICAL-MIB