All MIBs › SCANET-MIB
Category: Generic Switch Management
Description:
Manages SCANET network device configuration, interface status, and operational monitoring.
Imported Objects
What Is SCANET-MIB?
SCANET-MIB is described as managing SCANET network device configuration, interface status, and general operational monitoring, though no module description or sample object list was available for this module to confirm specifics. Based on its stated purpose, it likely exposes device configuration parameters and interface-level operational status typical of a vendor-specific network device MIB. Without sample objects to ground specific hardware/software status claims (uptime, temperature, CPU/memory), no detailed monitoring capabilities can be honestly asserted beyond the general interface-status and configuration focus indicated by its short description. It likely depends on standard MIB-II (IF-MIB) conventions for interface representation, as is typical for vendor device MIBs of this kind. It would be deployed wherever SCANET-branded network equipment is managed via SNMP. Loading SCANET-MIB into a MIB Browser would be a practical first step for an administrator to enumerate its actual configuration and interface-status objects, since published documentation for it is otherwise sparse.
IPNetwork Monitor allows you to monitor SNMP objects defined in SCANET-MIB. Use the built-in SNMP Monitoring Browser to explore available variables, view their current values and descriptions, and select the objects you want to monitor. You can then create SNMP monitors, configure thresholds, and receive alerts when monitored values change.
Supported Devices
- SCANET network devices
Monitoring Examples
No sample_objects were provided for this MIB, so no concrete object-level monitoring scenario can be honestly described; the module_desc field was also empty. Administrators would need to consult the actual MIB source to identify specific tables and objects available for configuration and interface status polling.
OIDs
| OID symbolic | OID numeric | Type | Access | Description |
|---|---|---|---|---|
| scanet | 1.3.6.1.4.1.208 | |||
| products | 1.3.6.1.4.1.208.1 | |||
| ts_2104 | 1.3.6.1.4.1.208.1.12 | |||
| cs_72xx | 1.3.6.1.4.1.208.1.13 | |||
| cs_76xx | 1.3.6.1.4.1.208.1.15 | |||
| cs_14xx | 1.3.6.1.4.1.208.1.32 | |||
| ethernetSwitch | 1.3.6.1.4.1.208.1.35 | |||
| es_1810 | 1.3.6.1.4.1.208.1.35.1 | |||
| es_1820 | 1.3.6.1.4.1.208.1.35.2 | |||
| es10t24 | 1.3.6.1.4.1.208.1.35.3 | |||
| es10t24plus | 1.3.6.1.4.1.208.1.35.4 | |||
| es_1520 | 1.3.6.1.4.1.208.1.35.5 | |||
| es_1850 | 1.3.6.1.4.1.208.1.35.6 | |||
| es_1851 | 1.3.6.1.4.1.208.1.35.7 | |||
| es100fx | 1.3.6.1.4.1.208.1.35.8 | |||
| cs_3300 | 1.3.6.1.4.1.208.1.42 | |||
| mfts | 1.3.6.1.4.1.208.1.67 | |||
| cs_21xx | 1.3.6.1.4.1.208.1.68 | |||
| ct_30xx | 1.3.6.1.4.1.208.1.69 | |||
| in_40xx | 1.3.6.1.4.1.208.1.82 | |||
| ct_40xx | 1.3.6.1.4.1.208.1.83 | |||
| matchboxRouter | 1.3.6.1.4.1.208.1.88 | |||
| mr_1010 | 1.3.6.1.4.1.208.1.88.1 | |||
| mr_1011 | 1.3.6.1.4.1.208.1.88.2 | |||
| mr_1013 | 1.3.6.1.4.1.208.1.88.3 | |||
| mr_1014 | 1.3.6.1.4.1.208.1.88.4 | |||
| mr_1050 | 1.3.6.1.4.1.208.1.88.5 | |||
| mr_1051 | 1.3.6.1.4.1.208.1.88.6 | |||
| mr_1110 | 1.3.6.1.4.1.208.1.88.7 | |||
| mr_1111 | 1.3.6.1.4.1.208.1.88.8 | |||
| mr_1113 | 1.3.6.1.4.1.208.1.88.9 | |||
| mr_1114 | 1.3.6.1.4.1.208.1.88.10 | |||
| mr_1150 | 1.3.6.1.4.1.208.1.88.11 | |||
| mr_1151 | 1.3.6.1.4.1.208.1.88.12 | |||
| mr_1055 | 1.3.6.1.4.1.208.1.88.13 | |||
| mr_1155 | 1.3.6.1.4.1.208.1.88.14 | |||
| mr_1020 | 1.3.6.1.4.1.208.1.88.15 | |||
| mr_1120 | 1.3.6.1.4.1.208.1.88.16 | |||
| mr_1023 | 1.3.6.1.4.1.208.1.88.17 | |||
| mr_1123 | 1.3.6.1.4.1.208.1.88.18 | |||
| mr_1024 | 1.3.6.1.4.1.208.1.88.19 | |||
| mr_1124 | 1.3.6.1.4.1.208.1.88.20 | |||
| mr_1040 | 1.3.6.1.4.1.208.1.88.21 | |||
| mr_1140 | 1.3.6.1.4.1.208.1.88.22 | |||
| mr_1021 | 1.3.6.1.4.1.208.1.88.23 | |||
| mr_1121 | 1.3.6.1.4.1.208.1.88.24 | |||
| er9100 | 1.3.6.1.4.1.208.1.88.25 | |||
| er9200 | 1.3.6.1.4.1.208.1.88.26 | |||
| er9300 | 1.3.6.1.4.1.208.1.88.27 | |||
| er9400 | 1.3.6.1.4.1.208.1.88.28 | |||
| mib2ext | 1.3.6.1.4.1.208.2 | |||
| system | 1.3.6.1.4.1.208.2.1 | |||
| INT reboot | 1.3.6.1.4.1.208.2.1.1 | INTEGER | read-write | Object to control actions in the device such as: resetNow(1) is reset the device immediately, reloadParm(7) is reload parameterblock from FLASH. saveParm(8) is save the parameter block to FLASH. Notice that not all products supports all values of this object. |
| INT ram | 1.3.6.1.4.1.208.2.1.2 | INTEGER | read-only | The size of the CPU RAM. |
| idTable | 1.3.6.1.4.1.208.2.1.3 | not-accessible | A table containing H/W and F/W identification. | |
| idEntry | 1.3.6.1.4.1.208.2.1.3.1 | not-accessible | A H/W and F/W information entry for each set of boards. | |
| INT brdNumber | 1.3.6.1.4.1.208.2.1.3.1.1 | INTEGER | read-only | An index identifying one or more boards. |
| STR hwId | 1.3.6.1.4.1.208.2.1.3.1.2 | DisplayString | read-only | H/W identification for the board, ex 10T24. |
| STR fwId | 1.3.6.1.4.1.208.2.1.3.1.3 | DisplayString | read-only | F/W identification for the board. ex PROM version number. |
| swTable | 1.3.6.1.4.1.208.2.1.4 | not-accessible | A table af S/W filenames. | |
| swEntry | 1.3.6.1.4.1.208.2.1.4.1 | not-accessible | A filename. | |
| STR swName | 1.3.6.1.4.1.208.2.1.4.1.1 | DisplayString | read-only | Filename of S/W. |
| INT errorLogNumber | 1.3.6.1.4.1.208.2.1.5 | INTEGER | read-write | Number of entries in the error log. Setting the value zero will clear the log. Set of any other value is invalid. |
| INT systemLogNumber | 1.3.6.1.4.1.208.2.1.6 | INTEGER | read-write | Number of entries in the system log. Setting the value zero will clear the log. Set of any other value is invalid. |
| autAccessTable | 1.3.6.1.4.1.208.2.1.7 | not-accessible | Authorization Access list. A list of all IP addresses that has passed the authorization. The access can be from either SNMP, TFTP or Telnet | |
| autAccessEntry | 1.3.6.1.4.1.208.2.1.7.1 | not-accessible | Authorization accept entry. | |
| IP autAccessIP | 1.3.6.1.4.1.208.2.1.7.1.1 | IpAddress | read-only | IP address of the host that has successfully passed the authorization. |
| TIK autAccessTime | 1.3.6.1.4.1.208.2.1.7.1.2 | TimeTicks | read-only | Time of last successfully access. |
| INT pysmiFakeCol988 | 1.3.6.1.4.1.208.2.1.7.1.4294967295 | INTEGER | not-accessible | |
| INT timeOfDay | 1.3.6.1.4.1.208.2.1.8 | INTEGER | read-write | The system's Time Of Day. The time is expresed in seconds since midnight (0 hour), Januar 1, 1970. |
| INT configurationLastChanged | 1.3.6.1.4.1.208.2.1.9 | INTEGER | read-only | Time Of Day the configuration was last changed. The time is expresed in seconds since midnight (0 hour), Januar 1, 1970. |
| INT configurationLastSaved | 1.3.6.1.4.1.208.2.1.10 | INTEGER | read-only | Time Of Day the configuration was saved to FLASH. The time is expresed in seconds since midnight (0 hour), Januar 1, 1970. |
| INT unsavedConfiguration | 1.3.6.1.4.1.208.2.1.11 | INTEGER | read-only | Indicates if there are unsaved configuration changes to FLASH. If the value is yes(2) the configuration has been changed and can be saved by setting the object reboot to saveParm(8). |
| ip | 1.3.6.1.4.1.208.2.4 | |||
| ipTable | 1.3.6.1.4.1.208.2.4.1 | not-accessible | This table is needed to set the IP address and the IP mask. Refer to the table ipAddrTable in MIB-II, for a description. | |
| ipEntry | 1.3.6.1.4.1.208.2.4.1.1 | not-accessible | Entry with an IP address and an IP mask. | |
| INT ipIndex | 1.3.6.1.4.1.208.2.4.1.1.1 | INTEGER | read-only | The value of an interface indentified by ifIndex. |
| OCT ipAddrAndMask | 1.3.6.1.4.1.208.2.4.1.1.2 | OCTET STRING | read-write | The IP Address and the Subnet Mask. The format of the octet string is: 4 bytes : IP Address 4 bytes : IP Subnet Mask. |
| IP pysmiFakeCol989 | 1.3.6.1.4.1.208.2.4.1.1.4294967295 | IpAddress | not-accessible | |
| snmp | 1.3.6.1.4.1.208.2.11 | |||
| INT filter | 1.3.6.1.4.1.208.2.11.1 | INTEGER | read-write | Filter to control logging af events. |
| STR print | 1.3.6.1.4.1.208.2.11.2 | DisplayString | read-only | A general object used for SNMP-TRAPS. Notice that this object for newer products is obsolete and replaced by unique TRAP's. |
| STR cause | 1.3.6.1.4.1.208.2.11.3 | DisplayString | read-only | A general object used for SNMP-TRAPS. Notice that this object for newer products is obsolete and replaced by unique TRAP's. |
| STR solution | 1.3.6.1.4.1.208.2.11.4 | DisplayString | read-only | A general object used for SNMP-TRAPS. Notice that this object for newer products is obsolete and replaced by unique TRAP's. |
| INT autMaxEntries | 1.3.6.1.4.1.208.2.11.5 | INTEGER | read-only | Maximun number of entries in the autTable |
| autTable | 1.3.6.1.4.1.208.2.11.6 | not-accessible | Authorization list. | |
| autEntry | 1.3.6.1.4.1.208.2.11.6.1 | not-accessible | Authorization entry. | |
| INT autNumber | 1.3.6.1.4.1.208.2.11.6.1.1 | INTEGER | read-only | A number that uniquely identifies an authorization entry. |
| OCT autIpAndAccessAndCommunity | 1.3.6.1.4.1.208.2.11.6.1.2 | OCTET STRING | read-write | This object contains the Ip address (4 byte), Access (1 byte) and Community (0 to 31 byte). If the Ip address is zero then any ip address is allowed. The Access can take the values readOnly(1) and readWrite(2). If the community string is zero length, then any value of community is allowed. |
| INT autDelete | 1.3.6.1.4.1.208.2.11.6.1.3 | INTEGER | read-write | The autEntry is removed when set to 1. Allways returns 0 |
| INT trapMaxEntries | 1.3.6.1.4.1.208.2.11.7 | INTEGER | read-only | Maximun number of entries in the trapTable |
| trapTable | 1.3.6.1.4.1.208.2.11.8 | not-accessible | Host Trap list. | |
| trapEntry | 1.3.6.1.4.1.208.2.11.8.1 | not-accessible | Host Trap entry. | |
| INT trapNumber | 1.3.6.1.4.1.208.2.11.8.1.1 | INTEGER | read-only | A number that uniquely identifies an trap entry. |
| OCT trapIpAndCommunity | 1.3.6.1.4.1.208.2.11.8.1.2 | OCTET STRING | read-write | This object contains the Ip address (4 byte) and the Community (0 to 31 byte) used in the Traps. |
| INT trapDelete | 1.3.6.1.4.1.208.2.11.8.1.3 | INTEGER | read-write | The trapEntry is removed when set to 1. Allways returns 0 |
| swUpdate | 1.3.6.1.4.1.208.2.40 | |||
| swInfoTable | 1.3.6.1.4.1.208.2.40.1 | not-accessible | Software information table. If the product has a dual software system the table contains two entries. | |
| swInfoEntry | 1.3.6.1.4.1.208.2.40.1.1 | not-accessible | Software information entry. | |
| INT swStatus | 1.3.6.1.4.1.208.2.40.1.1.1 | INTEGER | read-write | This object is only used for products with a dual software system. After loading and initiating new software the status is experimental. The software must be approved to be used after power off. |
| OCT swName2 | 1.3.6.1.4.1.208.2.40.1.1.2 | OCTET STRING | read-only | The software file name (0 to 46 bytes) |
| TIK swLoadTime | 1.3.6.1.4.1.208.2.40.1.1.3 | TimeTicks | read-only | The time the software was loaded and saved to FLASH. |
| IP swTftpIp | 1.3.6.1.4.1.208.2.40.1.1.4 | IpAddress | read-only | IP address of the TFTP server from which the software was loaded. |
| INT pysmiFakeCol990 | 1.3.6.1.4.1.208.2.40.1.1.4294967295 | INTEGER | not-accessible | |
| OCT swTftpIpAndSwName | 1.3.6.1.4.1.208.2.40.2 | OCTET STRING | read-write | This object contains the IP address of the TFTP server (4 bytes) and the software file name (0 to 46 bytes). This is used to initiate a software update. |
| INT swUpdateResult | 1.3.6.1.4.1.208.2.40.3 | INTEGER | read-only | The result of software update. |
| scaProt | 1.3.6.1.4.1.208.4 |
FAQ
What would SCANET-MIB let me check on a SCANET network device?
Based on its stated purpose, it covers device configuration parameters and interface-level operational status, typical of a vendor-specific network device MIB. An administrator managing SCANET equipment would use it as a general interface-status and configuration check, though published documentation for this module is sparse enough that specific object names can't be confirmed beyond that general scope.
Why would loading SCANET-MIB into a MIB browser be a useful first step before monitoring a SCANET device?
Since detailed object-level documentation for SCANET-MIB is limited, compiling it into a MIB browser lets an administrator directly enumerate its actual configuration and interface-status objects. It's also expected to build on standard MIB-II/IF-MIB conventions for representing interfaces, as is typical for vendor device MIBs of this kind.
RFC description
Scanner network management MIB for document imaging device monitoring.
Start monitoring SCANET network devices (configuration/interface status, vendor origin uncertain) with a free 30-day trial of IPNetwork Monitor. Import MIBs, browse SNMP OIDs, create custom SNMP monitors, configure alerts, and monitor any SNMP-enabled network device from a single console.