| OID symbolic | OID numeric | Type | Access | Description |
| rbnPvcMib | 1.3.6.1.4.1.2352.2.7 | | | Defines the objects necessary to support the management of
ATM, Frame Relay and IEEE 802.1Q permanent virtual circuits
(PVC). |
| rbnPvcMIBObjects | 1.3.6.1.4.1.2352.2.7.1 | | | |
| rbnAtmPvcConfigTable | 1.3.6.1.4.1.2352.2.7.1.1 | | not-accessible | This table contains the objects which identify and configure
ATM PVCs. |
| rbnAtmPvcConfigEntry | 1.3.6.1.4.1.2352.2.7.1.1.1 | | not-accessible | A conceptual row in the rbnAtmPvcConfigTable. |
| RBN rbnAtmPvcSlot | 1.3.6.1.4.1.2352.2.7.1.1.1.1 | RbnSlot | not-accessible | The chassis slot number |
| RBN rbnAtmPvcPort | 1.3.6.1.4.1.2352.2.7.1.1.1.2 | RbnPort | not-accessible | The port number |
| U32 rbnAtmPvcVpi | 1.3.6.1.4.1.2352.2.7.1.1.1.3 | Unsigned32 | not-accessible | The Virtual Path Identifier for the PVC. |
| U32 rbnAtmPvcVci | 1.3.6.1.4.1.2352.2.7.1.1.1.4 | Unsigned32 | not-accessible | The Virtual Channel Identifier for the PVC. |
| STR rbnAtmPvcProfileName | 1.3.6.1.4.1.2352.2.7.1.1.1.5 | SnmpAdminString | read-create | The profile name to use with the PVC. |
| RBN rbnAtmPvcEncapsulation | 1.3.6.1.4.1.2352.2.7.1.1.1.6 | RbnAtmEncapsulation | read-create | The encapsulation to use with the PVC. |
| ROW rbnAtmPvcRowStatus | 1.3.6.1.4.1.2352.2.7.1.1.1.8 | RowStatus | read-create | The row status for creating, modifying, or deleting an entry
in the table. |
| RBN rbnAtmPvcCircuitType | 1.3.6.1.4.1.2352.2.7.1.1.1.9 | RbnPvcCircuitType | read-create | The PVC circuit type. With respect to this mib
object, only those entries whose rbnAtmPvcCircuitType
has a value 'explicit' may be removed by setting
rbnAtmPvcRowStatus equal to 'destroy'. A set
operation with rbnAtmPvcRowStatus equal to 'destroy'
on any row with rbnAtmPvcCircuitType not equal to
'explicit' will result in an INCONSISTENT_VALUE_ERROR. |
| RBN rbnAtmPvcCircuitHandle | 1.3.6.1.4.1.2352.2.7.1.1.1.10 | RbnCircuitHandle | read-only | This object is used internally to uniquely identify
a circuit. The value of this object may be used to
correlate entries with those in the rbnBindTable defined
in the RBN-BIND-MIB. |
| T/F rbnAtmPvcClearCircuit | 1.3.6.1.4.1.2352.2.7.1.1.1.11 | TruthValue | read-create | When this object is true(1), the system will clear active
subscriber sessions on the specified circuit. When false(2),
there is no action taken. This object can only be written
when the conceptual row exists.
When this object is set to true(1) and the encapsulation
of the circuit is bridged or routed, e.g. bridge1483(2) or
route1483(4), subscribers will re-authenticate after
being cleared. |
| rbnFrameRelayPvcConfigTable | 1.3.6.1.4.1.2352.2.7.1.2 | | not-accessible | This table contains the objects which identify and configure
Frame Relay PVCs. |
| rbnFrameRelayPvcConfigEntry | 1.3.6.1.4.1.2352.2.7.1.2.1 | | not-accessible | A conceptual row in the rbnFrameRelayPvcConfigTable. |
| RBN rbnFrameRelayPvcSlot | 1.3.6.1.4.1.2352.2.7.1.2.1.1 | RbnSlot | not-accessible | The chassis slot number |
| RBN rbnFrameRelayPvcPort | 1.3.6.1.4.1.2352.2.7.1.2.1.2 | RbnPort | not-accessible | The port number |
| U32 rbnFrameRelayPvcChannel | 1.3.6.1.4.1.2352.2.7.1.2.1.3 | Unsigned32 | not-accessible | The channel number |
| U32 rbnFrameRelayPvcDLCI | 1.3.6.1.4.1.2352.2.7.1.2.1.4 | Unsigned32 | not-accessible | The Data Link Connection Identifier |
| STR rbnFrameRelayPvcProfileName | 1.3.6.1.4.1.2352.2.7.1.2.1.5 | SnmpAdminString | read-create | The profile name to use with the PVC. |
| RBN rbnFrameRelayPvcEncapsulation | 1.3.6.1.4.1.2352.2.7.1.2.1.6 | RbnFrameRelayEncapsulation | read-create | The encapsulation to use with the PVC. |
| ROW rbnFrameRelayPvcRowStatus | 1.3.6.1.4.1.2352.2.7.1.2.1.8 | RowStatus | read-create | The row status for creating, modifying, or deleting an entry
in the table. |
| RBN rbnFrameRelayPvcCircuitType | 1.3.6.1.4.1.2352.2.7.1.2.1.9 | RbnPvcCircuitType | read-create | The PVC circuit type. With respect to this mib
object, only those entries whose rbnFrameRelayPvcCircuitType
has a value 'explicit' may be removed by setting
rbnFrameRelayPvcRowStatus equal to 'destroy'. A set
operation with rbnFrameRelayPvcRowStatus equal to 'destroy'
on any row with rbnFrameRelayPvcCircuitType not equal to
'explicit' will result in an INCONSISTENT_VALUE_ERROR. |
| RBN rbnFrameRelayPvcCircuitHandle | 1.3.6.1.4.1.2352.2.7.1.2.1.10 | RbnCircuitHandle | read-only | This object is used internally to uniquely identify
a circuit. The value of this object may be used to
correlate entries with those in the rbnBindTable defined
in the RBN-BIND-MIB. |
| T/F rbnFrameRelayPvcClearCircuit | 1.3.6.1.4.1.2352.2.7.1.2.1.11 | TruthValue | read-create | When this object is true(1), the system will clear active
subscriber sessions on the specified circuit. When false(2),
there is no action taken. This object can only be written
when the conceptual row exists.
When this object is set to true(1) and the encapsulation
of the circuit is bridged or routed, e.g. bridge1490(2) or
route1490(4), subscribers will re-authenticate after
being cleared. |
| rbnDot1qPvcOnEthConfigTable | 1.3.6.1.4.1.2352.2.7.1.3 | | not-accessible | This table contains the objects which identify and configure
IEEE 802.1Q PVCs on Ethernet ports. |
| rbnDot1qPvcOnEthConfigEntry | 1.3.6.1.4.1.2352.2.7.1.3.1 | | not-accessible | A conceptual row in the rbnDot1qPvcOnEthConfigTable. |
| RBN rbnDot1qPvcOnEthSlot | 1.3.6.1.4.1.2352.2.7.1.3.1.1 | RbnSlot | not-accessible | The chassis slot number. |
| RBN rbnDot1qPvcOnEthPort | 1.3.6.1.4.1.2352.2.7.1.3.1.2 | RbnPort | not-accessible | The port number. |
| RBN rbnDot1qPvcOnEthVlanId | 1.3.6.1.4.1.2352.2.7.1.3.1.3 | RbnVidOrUntagged | not-accessible | IEEE 802.1Q Virtual LAN (VLAN) tag value. |
| ROW rbnDot1qPvcOnEthRowStatus | 1.3.6.1.4.1.2352.2.7.1.3.1.4 | RowStatus | read-create | The row status for creating, modifying, or deleting an entry
in the table. |
| STR rbnDot1qPvcOnEthProfileName | 1.3.6.1.4.1.2352.2.7.1.3.1.5 | SnmpAdminString | read-create | The profile name to use with the PVC. |
| RBN rbnDot1qPvcOnEthEncapsulation | 1.3.6.1.4.1.2352.2.7.1.3.1.6 | RbnDot1qEncapsulation | read-create | The encapsulation to use with the PVC. |
| RBN rbnDot1qPvcOnEthCircuitType | 1.3.6.1.4.1.2352.2.7.1.3.1.7 | RbnPvcCircuitType | read-create | The PVC circuit type. With respect to this mib object,
only those entries whose rbnDot1qPvcOnEthCircuitType
has a value 'explicit' may be removed by setting
rbnDot1qPvcOnEthRowStatus equal to 'destroy'. A set
operation with rbnDot1qPvcOnEthRowStatus equal to 'destroy'
on any row with rbnDot1qPvcOnEthCircuitType not equal to
'explicit' will result in an INCONSISTENT_VALUE_ERROR. |
| RBN rbnDot1qPvcOnEthCircuitHandle | 1.3.6.1.4.1.2352.2.7.1.3.1.8 | RbnCircuitHandle | read-only | This object is used internally to uniquely identify
a circuit. The value of this object may be used to
correlate entries with those in the rbnBindTable defined
in the RBN-BIND-MIB. |
| T/F rbnDot1qPvcOnEthClearCircuit | 1.3.6.1.4.1.2352.2.7.1.3.1.9 | TruthValue | read-create | When this object is true(1), the system will clear active
subscriber sessions on the specified circuit. When false(2),
there is no action taken. This object can only be written
when the conceptual row exists. |
| rbnDot1qPvcOnAtmConfigTable | 1.3.6.1.4.1.2352.2.7.1.4 | | not-accessible | This table contains the objects which identify and configure
IEEE 802.1Q PVCs on ATM circuits. |
| rbnDot1qPvcOnAtmConfigEntry | 1.3.6.1.4.1.2352.2.7.1.4.1 | | not-accessible | A conceptual row in the rbnDot1qPvcOnAtmConfigTable. |
| RBN rbnDot1qPvcOnAtmSlot | 1.3.6.1.4.1.2352.2.7.1.4.1.1 | RbnSlot | not-accessible | The chassis slot number. |
| RBN rbnDot1qPvcOnAtmPort | 1.3.6.1.4.1.2352.2.7.1.4.1.2 | RbnPort | not-accessible | The port number. |
| U32 rbnDot1qPvcOnAtmVpi | 1.3.6.1.4.1.2352.2.7.1.4.1.3 | Unsigned32 | not-accessible | The Virtual Path Identifier for the PVC. |
| U32 rbnDot1qPvcOnAtmVci | 1.3.6.1.4.1.2352.2.7.1.4.1.4 | Unsigned32 | not-accessible | The Virtual Channel Identifier for the PVC. |
| RBN rbnDot1qPvcOnAtmVlanId | 1.3.6.1.4.1.2352.2.7.1.4.1.5 | RbnVidOrUntagged | not-accessible | IEEE 802.1Q Virtual LAN (VLAN) tag value. |
| ROW rbnDot1qPvcOnAtmRowStatus | 1.3.6.1.4.1.2352.2.7.1.4.1.6 | RowStatus | read-create | The row status for creating, modifying, or deleting an entry
in the table. |
| STR rbnDot1qPvcOnAtmProfileName | 1.3.6.1.4.1.2352.2.7.1.4.1.7 | SnmpAdminString | read-create | The profile name to use with the PVC. |
| RBN rbnDot1qPvcOnAtmEncapsulation | 1.3.6.1.4.1.2352.2.7.1.4.1.8 | RbnDot1qEncapsulation | read-create | The encapsulation to use with the PVC. |
| RBN rbnDot1qPvcOnAtmCircuitType | 1.3.6.1.4.1.2352.2.7.1.4.1.9 | RbnPvcCircuitType | read-create | The PVC circuit type. With respect to this mib object,
only those entries whose rbnDot1qPvcOnAtmCircuitType
has a value 'explicit' may be removed by setting
rbnDot1qPvcOnAtmRowStatus equal to 'destroy'. A set
operation with rbnDot1qPvcOnAtmRowStatus equal to 'destroy'
on any row with rbnDot1qPvcOnAtmCircuitType not equal to
'explicit' will result in an INCONSISTENT_VALUE_ERROR. |
| RBN rbnDot1qPvcOnAtmCircuitHandle | 1.3.6.1.4.1.2352.2.7.1.4.1.10 | RbnCircuitHandle | read-only | This object is used internally to uniquely identify
a circuit. The value of this object may be used to
correlate entries with those in the rbnBindTable defined
in the RBN-BIND-MIB. |
| T/F rbnDot1qPvcOnAtmClearCircuit | 1.3.6.1.4.1.2352.2.7.1.4.1.11 | TruthValue | read-create | When this object is true(1), the system will clear active
subscriber sessions on the specified circuit. When false(2),
there is no action taken. This object can only be written
when the conceptual row exists. |
| rbnDot1qPvcOnFrConfigTable | 1.3.6.1.4.1.2352.2.7.1.5 | | not-accessible | This table contains the objects which identify and configure
IEEE 802.1Q PVCs on ATM circuits. |
| rbnDot1qPvcOnFrConfigEntry | 1.3.6.1.4.1.2352.2.7.1.5.1 | | not-accessible | A conceptual row in the rbnDot1qPvcOnFrConfigTable. |
| RBN rbnDot1qPvcOnFrSlot | 1.3.6.1.4.1.2352.2.7.1.5.1.1 | RbnSlot | not-accessible | The chassis slot number. |
| RBN rbnDot1qPvcOnFrPort | 1.3.6.1.4.1.2352.2.7.1.5.1.2 | RbnPort | not-accessible | The port number. |
| U32 rbnDot1qPvcOnFrChannel | 1.3.6.1.4.1.2352.2.7.1.5.1.3 | Unsigned32 | not-accessible | The channel number. |
| U32 rbnDot1qPvcOnFrDLCI | 1.3.6.1.4.1.2352.2.7.1.5.1.4 | Unsigned32 | not-accessible | The Data Link Connection Identifier. |
| RBN rbnDot1qPvcOnFrVlanId | 1.3.6.1.4.1.2352.2.7.1.5.1.5 | RbnVidOrUntagged | not-accessible | IEEE 802.1Q Virtual LAN (VLAN) tag value. |
| ROW rbnDot1qPvcOnFrRowStatus | 1.3.6.1.4.1.2352.2.7.1.5.1.6 | RowStatus | read-create | The row status for creating, modifying, or deleting an entry
in the table. |
| STR rbnDot1qPvcOnFrProfileName | 1.3.6.1.4.1.2352.2.7.1.5.1.7 | SnmpAdminString | read-create | The profile name to use with the PVC. |
| RBN rbnDot1qPvcOnFrEncapsulation | 1.3.6.1.4.1.2352.2.7.1.5.1.8 | RbnDot1qEncapsulation | read-create | The encapsulation to use with the PVC. |
| RBN rbnDot1qPvcOnFrCircuitType | 1.3.6.1.4.1.2352.2.7.1.5.1.9 | RbnPvcCircuitType | read-create | The PVC circuit type. With respect to this mib object,
only those entries whose rbnDot1qPvcOnFrCircuitType
has a value 'explicit' may be removed by setting
rbnDot1qPvcOnFrRowStatus equal to 'destroy'. A set
operation with rbnDot1qPvcOnFrRowStatus equal to 'destroy'
on any row with rbnDot1qPvcOnFrCircuitType not equal to
'explicit' will result in an INCONSISTENT_VALUE_ERROR. |
| RBN rbnDot1qPvcOnFrCircuitHandle | 1.3.6.1.4.1.2352.2.7.1.5.1.10 | RbnCircuitHandle | read-only | This object is used internally to uniquely identify
a circuit. The value of this object may be used to
correlate entries with those in the rbnBindTable defined
in the RBN-BIND-MIB. |
| T/F rbnDot1qPvcOnFrClearCircuit | 1.3.6.1.4.1.2352.2.7.1.5.1.11 | TruthValue | read-create | When this object is true(1), the system will clear active
subscriber sessions on the specified circuit. When false(2),
there is no action taken. This object can only be written
when the conceptual row exists. |
| rbnPvcMIBConformance | 1.3.6.1.4.1.2352.2.7.2 | | | |
| rbnPvcCompliances | 1.3.6.1.4.1.2352.2.7.2.1 | | | |
| rbnPvcCompliance | 1.3.6.1.4.1.2352.2.7.2.1.1 | | | The compliance statement for SNMP entities which implement
the RBN-PVC-MIB. |
| rbnPvcCompliance2 | 1.3.6.1.4.1.2352.2.7.2.1.2 | | | The compliance statement for SNMP entities which implement
the RBN-PVC-MIB. |
| rbnPvcCompliance3 | 1.3.6.1.4.1.2352.2.7.2.1.3 | | | The compliance statement for SNMP entities which implement
the RBN-PVC-MIB. |
| rbnPvcGroups | 1.3.6.1.4.1.2352.2.7.2.2 | | | |
| rbnAtmPvcGroup | 1.3.6.1.4.1.2352.2.7.2.2.1 | | | the collection of objects which represent the ATM PVC. |
| rbnFrameRelayPvcGroup | 1.3.6.1.4.1.2352.2.7.2.2.2 | | | the collection of objects which represent the FrameRelay PVC. |
| rbnAtmPvcGroup2 | 1.3.6.1.4.1.2352.2.7.2.2.3 | | | The collection of objects which represent the ATM PVC. |
| rbnFrameRelayPvcGroup2 | 1.3.6.1.4.1.2352.2.7.2.2.4 | | | The collection of objects which represent the FrameRelay PVC. |
| rbnDot1qPvcOnEthGroup | 1.3.6.1.4.1.2352.2.7.2.2.5 | | | A collection of objects providing information specific
to IEEE 802.1Q PVCs on Ethernet ports. |
| rbnDot1qPvcOnAtmGroup | 1.3.6.1.4.1.2352.2.7.2.2.6 | | | A collection of objects providing information specific
to IEEE 802.1Q PVCs on ATM circuits. |
| rbnDot1qPvcOnFrGroup | 1.3.6.1.4.1.2352.2.7.2.2.7 | | | A collection of objects providing information specific
to IEEE 802.1Q PVCs on Frame Relay circuits. |
| rbnPvcMIBNotifications | 1.3.6.1.4.1.2352.2.7.3 | | | |