RAPID-CITY :: rcHighPriorityMode

MIB Reference — IPNetwork Monitor · Updated September 12, 2026

All MIBsRAPID-CITYrcHighPriorityMode

rcHighPriorityMode

Module: RAPID-CITY

OID (symbolic): RAPID-CITY::rcHighPriorityMode

OID (numeric): 1.3.6.1.4.1.2272.1.6.3

Node type: OBJECT-TYPE

Type: TruthValue

Access: read-only

Description: Used to indicate whether the system is configured to operate in a high priority mode. The switch can operate in either a 'best effort' or 'high priority' mode. In the 'best effort' setting, the maximum queue thresholds for the QUIDs are set to 768/768 buffers. In the 'high priority' mode the setting is 512/768. This means that in 'high priority' mode the normal priority queue can't have more than 512 buffers, while the high priority queue can have up to 768.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.2272.1.6.3
snmpwalk -v2c -c public <target> RAPID-CITY::rcHighPriorityMode

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.2272.1.6.3.1
snmpget -v2c -c public <target> RAPID-CITY::rcHighPriorityMode.1

Start monitoring Bay Networks/Nortel Accelar and Ethernet Routing Switch (ERS) chassis switches with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the RAPID-CITY::rcHighPriorityMode OID value, configure state conditions and alerts, and monitor any Bay Networks/Nortel Accelar and Ethernet Routing Switch (ERS) chassis switches from a single console.

OID Breakdown

Upper-level ancestors (6 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
Numeric OIDNameModule
1.3.6.1.4.1.2272rapidCityRAPID-CITY
1.3.6.1.4.1.2272.1rcMgmtRAPID-CITY
1.3.6.1.4.1.2272.1.6rcDipSwitchRAPID-CITY
1.3.6.1.4.1.2272.1.6.3rcHighPriorityModeRAPID-CITY