RAPID-CITY-VSP :: rcChasFanZoneAlarmTimer

MIB Reference — IPNetwork Monitor · Updated September 21, 2026

All MIBs › RAPID-CITY-VSP › rcChasFanZoneAlarmTimer

rcChasFanZoneAlarmTimer

Module: RAPID-CITY-VSP

OID (symbolic): RAPID-CITY-VSP::rcChasFanZoneAlarmTimer

OID (numeric): 1.3.6.1.4.1.2272.1.4.7.2.1.4

Node type: OBJECT-TYPE

Type: Integer32

Access: read-only

Description: Alarm timer indicates the remaining time before system checks and shutdown module when fan is in the alarm state. Zero means the fan i snot in an alarm state

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.2272.1.4.7.2.1.4
snmpwalk -v2c -c public <target> RAPID-CITY-VSP::rcChasFanZoneAlarmTimer

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.2272.1.4.7.2.1.4.1
snmpget -v2c -c public <target> RAPID-CITY-VSP::rcChasFanZoneAlarmTimer.1

Start monitoring Nortel/Bay Networks Accelar switch-router, Nortel Passport/Ethernet Routing Switch chassis with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the RAPID-CITY-VSP::rcChasFanZoneAlarmTimer OID value, configure state conditions and alerts, and monitor any Nortel/Bay Networks Accelar switch-router, Nortel Passport/Ethernet Routing Switch chassis from a single console.

OID Breakdown

Upper-level ancestors (10 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.2272rapidCityRAPID-CITY
1.3.6.1.4.1.2272.1rcMgmtRAPID-CITY
1.3.6.1.4.1.2272.1.4rcChassisRAPID-CITY
1.3.6.1.4.1.2272.1.4.7rcChasFanRAPID-CITY
Numeric OIDNameModule
1.3.6.1.4.1.2272.1.4.7.2rcChasFanZoneTableRAPID-CITY-VSP
1.3.6.1.4.1.2272.1.4.7.2.1rcChasFanZoneEntryRAPID-CITY-VSP
1.3.6.1.4.1.2272.1.4.7.2.1.4rcChasFanZoneAlarmTimerRAPID-CITY-VSP