RAD-MIB :: atmNteConfOamAIS

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsRAD-MIBatmNteConfOamAIS

atmNteConfOamAIS

Module: RAD-MIB

OID (symbolic): RAD-MIB::atmNteConfOamAIS

OID (numeric): 1.3.6.1.4.1.164.12.3.1.1.9.2.1

Node type: OBJECT-TYPE

Type: INTEGER

Access: read-write

Description: Defines if a F4 segment OAM cell is transmitted due to problems in the other port, i.e. physical layer alarm or F4 defect. This is valid only when the ACE101 has ATM UNI interfaces in both sides and is configured for 'Non-Intrusive' mode. none - AIS is not sent to any of the ports. user - F4 AIS will be sent toward the user when defect is detected in the network port. network - F4 AIS will be sent toward the network when defect is detected in the user port. both - F4 AIS will be sent toward the network when defect is detected in the user port and toward the user when defect is detected in the network port.

What is atmNteConfOamAIS?

This object controls whether F4 segment OAM Alarm Indication Signal cells are transmitted when detecting defects in the opposite ATM port, with options to send toward user, network, both, or neither. In Non-Intrusive monitoring mode on dual-port ATM equipment, this setting determines how failures are propagated to alert adjacent network elements. Proper configuration ensures failure notifications reach the appropriate endpoints without creating unnecessary traffic.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.164.12.3.1.1.9.2.1
snmpwalk -v2c -c public <target> RAD-MIB::atmNteConfOamAIS

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.164.12.3.1.1.9.2.1.1
snmpget -v2c -c public <target> RAD-MIB::atmNteConfOamAIS.1

Set instance 1 (SNMPv2c):

snmpset -v2c -c private <target> 1.3.6.1.4.1.164.12.3.1.1.9.2.1.1 i <value>

Start monitoring RAD Data Communications access/transmission/multiplexer equipment, entire product line (base enterprise MIB) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the RAD-MIB::atmNteConfOamAIS OID value, configure state conditions and alerts, and monitor any RAD Data Communications access/transmission/multiplexer equipment, entire product line (base enterprise MIB) from a single console.

OID Breakdown

Upper-level ancestors (7 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.164radDACS-MIB
Numeric OIDNameModule
1.3.6.1.4.1.164.12radAtmRAD-MIB
1.3.6.1.4.1.164.12.3atmNteRAD-MIB
1.3.6.1.4.1.164.12.3.1atmNteSysRAD-MIB
1.3.6.1.4.1.164.12.3.1.1atmNteSysConfigRAD-MIB
1.3.6.1.4.1.164.12.3.1.1.9atmNteConfOamRAD-MIB
1.3.6.1.4.1.164.12.3.1.1.9.2atmNteConfOamTransmissionRAD-MIB
1.3.6.1.4.1.164.12.3.1.1.9.2.1atmNteConfOamAISRAD-MIB