All MIBs › RAD-MIB › atmNteConfOamAIS
atmNteConfOamAIS
Module: RAD-MIB
OID (symbolic): RAD-MIB::atmNteConfOamAIS
OID (numeric): 1.3.6.1.4.1.164.12.3.1.1.9.2.1
Node type: OBJECT-TYPE
Type: INTEGER
Access: read-write
Description: Defines if a F4 segment OAM cell is transmitted due to problems in the other port, i.e. physical layer alarm or F4 defect. This is valid only when the ACE101 has ATM UNI interfaces in both sides and is configured for 'Non-Intrusive' mode. none - AIS is not sent to any of the ports. user - F4 AIS will be sent toward the user when defect is detected in the network port. network - F4 AIS will be sent toward the network when defect is detected in the user port. both - F4 AIS will be sent toward the network when defect is detected in the user port and toward the user when defect is detected in the network port.
What is atmNteConfOamAIS?
This object controls whether F4 segment OAM Alarm Indication Signal cells are transmitted when detecting defects in the opposite ATM port, with options to send toward user, network, both, or neither. In Non-Intrusive monitoring mode on dual-port ATM equipment, this setting determines how failures are propagated to alert adjacent network elements. Proper configuration ensures failure notifications reach the appropriate endpoints without creating unnecessary traffic.
Examples
Walk all instances (SNMPv2c):
snmpwalk -v2c -c public <target> 1.3.6.1.4.1.164.12.3.1.1.9.2.1 snmpwalk -v2c -c public <target> RAD-MIB::atmNteConfOamAIS
Get a specific instance (index 1):
snmpget -v2c -c public <target> 1.3.6.1.4.1.164.12.3.1.1.9.2.1.1 snmpget -v2c -c public <target> RAD-MIB::atmNteConfOamAIS.1
Set instance 1 (SNMPv2c):
snmpset -v2c -c private <target> 1.3.6.1.4.1.164.12.3.1.1.9.2.1.1 i <value>
Start monitoring RAD Data Communications access/transmission/multiplexer equipment, entire product line (base enterprise MIB) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the RAD-MIB::atmNteConfOamAIS OID value, configure state conditions and alerts, and monitor any RAD Data Communications access/transmission/multiplexer equipment, entire product line (base enterprise MIB) from a single console.
OID Breakdown
Upper-level ancestors (7 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.4 | private | AirPair-MIB |
| 1.3.6.1.4.1 | enterprises | AirPair-MIB |
| 1.3.6.1.4.1.164 | rad | DACS-MIB |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.164.12 | radAtm | RAD-MIB |
| 1.3.6.1.4.1.164.12.3 | atmNte | RAD-MIB |
| 1.3.6.1.4.1.164.12.3.1 | atmNteSys | RAD-MIB |
| 1.3.6.1.4.1.164.12.3.1.1 | atmNteSysConfig | RAD-MIB |
| 1.3.6.1.4.1.164.12.3.1.1.9 | atmNteConfOam | RAD-MIB |
| 1.3.6.1.4.1.164.12.3.1.1.9.2 | atmNteConfOamTransmission | RAD-MIB |
| 1.3.6.1.4.1.164.12.3.1.1.9.2.1 | atmNteConfOamAIS | RAD-MIB |