RAD-MIB :: agnStationClockCard

MIB Reference — IPNetwork Monitor

All MIBsRAD-MIBagnStationClockCard

agnStationClockCard

Module: RAD-MIB

OID (symbolic): RAD-MIB::agnStationClockCard

OID (numeric): 1.3.6.1.4.1.164.6.2.29

Node type: OBJECT-TYPE

Type: INTEGER

Access: read-only

Description:

This entry specifies the station clock card existence and status. notExist - station clock card (piggy) does not exist. notValid - station clock card exists but clock status is not valid. ok - station clock card exists, and its status is OK When the sepcific reason for clock status not being valid is known, it may be reported by lossOfSync or lossOfSignal values.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.164.6.2.29
snmpwalk -v2c -c public <target> RAD-MIB::agnStationClockCard

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.164.6.2.29.1
snmpget -v2c -c public <target> RAD-MIB::agnStationClockCard.1

SNMPv3 example:

snmpget -v3 -l authPriv -u snmpv3-user -a SHA -A "AuthPassword1" -x AES -X "PrivPassword1" <target> agnStationClockCard.1

OID Breakdown

Numeric OIDNameModule
1isoLANART-AGENT
1.3orgBIANCA-BRICK-PPP-MIB
1.3.6dodBIANCA-BRICK-PPP-MIB
1.3.6.1internetBIANCA-BRICK-PPP-MIB
1.3.6.1.4privateBIANCA-BRICK-PPP-MIB
1.3.6.1.4.1enterprisesANIROOT-MIB
1.3.6.1.4.1.164radDACS-MIB
1.3.6.1.4.1.164.6radGenDACS-MIB
1.3.6.1.4.1.164.6.2agntDACS-MIB
1.3.6.1.4.1.164.6.2.29agnStationClockCardRAD-MIB