ONEACCESS-DOT11-MIB

MIB Reference — IPNetwork Monitor · Updated October 06, 2026

All MIBs › ONEACCESS-DOT11-MIB

Organization: OneAccess

Last Updated: 2011-10-27

Category: CPE/Router

Description: Manages IEEE 802.11 wireless LAN configuration and station statistics on OneAccess CPE routers.

Start monitoring vendor-neutral, standards-based MIB, any SNMPv3-capable network device (SNMP engine identity/boot/clock status) with a free 30-day trial of IPNetwork Monitor. Import MIBs, browse SNMP OIDs, create custom SNMP monitors, configure alerts, and monitor any SNMP-enabled network device from a single console.

What Is ONEACCESS-DOT11-MIB?

ONEACCESS-DOT11-MIB is a OneAccess-specific SNMP module (OneAccess, now part of ECI Telecom, made branch-office CPE routers) that manages IEEE 802.11 wireless LAN interfaces embedded in its customer-premises routers. It exposes wireless interface configuration data such as SSID, MAC address, and interface type, along with a count of currently associated stations. This makes it useful for monitoring the operational status of the built-in Wi-Fi radio on the router, including whether the access point is configured correctly and how many client stations are currently connected, functioning as a health/status indicator for the wireless subsystem of the device. It builds on standard 802.11 wireless concepts but is implemented as a proprietary extension rather than referencing a common IEEE 802.11 MIB directly. It is typically deployed in small branch or remote-office environments where a OneAccess router provides integrated Wi-Fi access alongside WAN routing, and ONEACCESS-DOT11-MIB SNMP monitoring tracks the wireless subsystem's health.

IPNetwork Monitor allows you to monitor SNMP objects defined in ONEACCESS-DOT11-MIB. Use the built-in SNMP Monitoring Browser to explore available variables, view their current values and descriptions, and select the objects you want to monitor. You can then create SNMP monitors, configure thresholds, and receive alerts when monitored values change.

Supported Devices

  • OneAccess CPE routers
  • branch-office routers with integrated Wi-Fi

Monitoring Examples

An administrator would poll oacExpIMDot11InterfaceTable/oacExpIMDot11InterfaceEntry to read oacExpIMDot11SSID and oacExpIMDot11MACAddress for each wireless interface, confirming the AP is broadcasting the expected network. Watching oacExpIMDot11AssociatedStations over time reveals unexpected drops in client count, which can indicate radio interference, a misconfiguration, or a hardware fault in the Wi-Fi module. oacExpIMDot11EntryType helps distinguish access-point versus client-mode interfaces on the CPE.

What Can Be Monitored

  • wireless interface SSID
  • interface MAC address
  • number of associated stations
  • interface entry type
Imported Objects

From IF-MIB

ifIndexOBJECT-TYPE

From ONEACCESS-GLOBAL-REG

oacExpIMDot11OBJECT-IDENTITY
oacMIBModulesOBJECT-IDENTITY
oacRequirementsOBJECT-IDENTITY

From SNMPv2-CONF

MODULE-COMPLIANCE
OBJECT-GROUP

From SNMPv2-SMI

Counter32
MODULE-IDENTITY
OBJECT-TYPE

From SNMPv2-TC

MacAddress
TEXTUAL-CONVENTION

How to Use in IPNetwork Monitor

Example using oacExpIMDot11AssociatedStations OID:

Select an OneAccess CPE router with integrated Wi-Fi (802.11 wireless LAN) as the target host to create a monitor — the SNMP service should be up and running on it. Click New Monitor, then check SNMP Custom on the Favorites tab, click Next, and confirm the host. On the next page, click Select... to open the built-in SNMP MIB Browser and type oacExpIMDot11AssociatedStations into the Find box to locate it in the OID tree, then select it and click OK. This counter is the number of currently associated stations, for vap entries, the stations associated on the SSID of this vap, for radio entry the total of all associated stations. On the monitor's Main parameters page you can set the target's SNMP port (default 161), credentials, polling interval, and other settings — see the SNMP Monitor help for details. On the State conditions and Alerting tabs, configure when the monitor should change state and trigger an alert; since this is a Counter32-type OID, Value bounds is the most useful condition here — trigger an alert if the counter increases sharply between polls relative to its normal baseline, since an unexpected spike often reflects a real change in traffic or activity. Click Finish to create the monitor; you can adjust any parameter later.
OIDs

RFC description

IEEE 802.11 wireless interface management for OneAccess equipment.

Start monitoring OneAccess CPE router with integrated Wi-Fi (802.11 wireless LAN) with a free 30-day trial of IPNetwork Monitor. Import MIBs, browse SNMP OIDs, create custom SNMP monitors, configure alerts, and monitor any SNMP-enabled network device from a single console.

Download ONEACCESS-DOT11-MIB