| OID symbolic | OID numeric | Type | Access | Description |
| codex | 1.3.6.1.4.1.449 | | | |
| cdxProductSpecific | 1.3.6.1.4.1.449.2 | | | |
| cdx6500 | 1.3.6.1.4.1.449.2.1 | | | |
| cdx6500Configuration | 1.3.6.1.4.1.449.2.1.2 | | | |
| cdx6500CfgProtocolGroup | 1.3.6.1.4.1.449.2.1.2.1 | | | |
| cdx6500PCTPortProtocolGroup | 1.3.6.1.4.1.449.2.1.2.1.1 | | | |
| cdx6500PPCTNCRBisyncTable | 1.3.6.1.4.1.449.2.1.2.1.1.17 | | not-accessible | A table of NCRBSC Port configuration entries. |
| cdx6500PPCTNCRBisyncEntry | 1.3.6.1.4.1.449.2.1.2.1.1.17.1 | | not-accessible | A NCRBSC Configuration Table entry. Each entry
contains the configuration parameters for a single
NCRBSC port. |
| INT cdx6500NCRBSCCfgPortNumber | 1.3.6.1.4.1.449.2.1.2.1.1.17.1.1 | INTEGER | read-only | The NCRBSC port number described by this entry. |
| INT cdx6500NCRBSCCfgPADType | 1.3.6.1.4.1.449.2.1.2.1.1.17.1.2 | INTEGER | read-only | Indicates whether the port is functioning as a
Terminal PAD (TPAD) or a Host PAD (HPAD).
newvalTpad : same functionality as 'tpad', new enumeration
added for RFC1155 compatibility. |
| INT cdx6500NCRBSCCfgClockSource | 1.3.6.1.4.1.449.2.1.2.1.1.17.1.3 | INTEGER | read-only | int - internal clock source.
ext - external clock source.
newvalInt - same functionality as 'int', new
enumeration added for RFC1155 compatibility. |
| INT cdx6500NCRBSCCfgClockSpeed | 1.3.6.1.4.1.449.2.1.2.1.1.17.1.4 | INTEGER | read-only | This is the speed of the port in bits per second,
when using internal clocking. |
| INT cdx6500NCRBSCCfgContention | 1.3.6.1.4.1.449.2.1.2.1.1.17.1.5 | INTEGER | read-only | Indicates whether Half Duplex (hdx) or
Full Duplex (fdx) modem signals are being generated.
Full Duplex indicates communication is occuring
in both directions simultaneously between devices.
Half Duplex indicates transmission is occuring
in both directions, but only in one direction
at a time.
newvalHdx - same functionality as 'hdx', new enumeration
added for RFC1155 compatibility. |
| INT cdx6500NCRBSCCfgNumDevices | 1.3.6.1.4.1.449.2.1.2.1.1.17.1.6 | INTEGER | read-only | Specifies the number of physical devices on this line. |
| INT cdx6500NCRBSCCfgServTimer | 1.3.6.1.4.1.449.2.1.2.1.1.17.1.7 | INTEGER | read-only | The Service Timer specifies the interval of time in
seconds between periodic servicing. Such servicing
includes intervals between the time the PAD will
attempt to poll devices that previously failed to
respond and intervals between failures in attempts
to establish a connection from a device configured
for Autocall. |
| INT cdx6500NCRBSCCfgErrThreshCount | 1.3.6.1.4.1.449.2.1.2.1.1.17.1.8 | INTEGER | read-only | Indicates number of consecutive errors that can occur
before a device is considered down. |
| INT cdx6500NCRBSCCfgRetranTimeout | 1.3.6.1.4.1.449.2.1.2.1.1.17.1.10 | INTEGER | read-only | Specifies the amount of time in TENTHS OF A SECOND before a
retransmission of the previously sent protocol sequence is
attempted. The effective range is 0.1 - 25.5 seconds.
The MINIMUM acceptable values are dependent on the speed
configured as follows (speed - responsetimeout):
1200 - 12, 2400 - 6, 4800 - 3,9600 - 2, 19200 - 2 |
| INT cdx6500NCRBSCCfgInterBuffTimeout | 1.3.6.1.4.1.449.2.1.2.1.1.17.1.11 | INTEGER | read-only | Specifies the maximum amount of time in seconds the PAD
will wait for the end of a multi-packet message from the
network. If this time limit is exceeded, the PAD will
abort the entire message and request retransmission. |
| STR cdx6500NCRBSCCfgPortSubAddr | 1.3.6.1.4.1.449.2.1.2.1.1.17.1.12 | DisplayString | read-only | 0 - 3 Decimal digits
Calls addressed to this node and with this subaddress
will be routed to this port. |
| STR cdx6500NCRBSCCfgPortOptions | 1.3.6.1.4.1.449.2.1.2.1.1.17.1.13 | DisplayString | read-only | Select options on this NCRBSC port as follows:
NONE - no option specified
ORG - Controllers on this port will originate the calls
ACK - DSP End-to-End Acknowledgements are to be used
Any combination of above specified by summing
(e.g. ORG+ACK). |
| STR cdx6500NCRBSCCfgRestrictConnDest | 1.3.6.1.4.1.449.2.1.2.1.1.17.1.14 | DisplayString | read-only | 1 - 32 Decimal digits or a single blank
All calls originating from this port will be routed to
the destination specified in this parameter, irrespective
of route selection table entries. For example, to route
calls to port 1, use P1. To route calls to port 2,
station 4, use P2S4.
Blank this field to disable this function. |
| INT cdx6500NCRBSCCfgBillRec | 1.3.6.1.4.1.449.2.1.2.1.1.17.1.15 | INTEGER | read-only | This controls whether billing (accounting) records will
be created for calls on this Device.
newvalOff : same functionality as 'off', new enumeration
added for RFC1155 compatibility. |
| INT cdx6500NCRBSCCfgElectricalInterfaceType | 1.3.6.1.4.1.449.2.1.2.1.1.17.1.16 | INTEGER | read-only | Specify the Electrical Interface Type:
V.24 - V.24 Electrical Interface Type
V.35 - V.35 Electrical Interface Type
V.36 - V.36 Electrical Interface Type
X.21 - X.21 Electrical Interface Type
NONE - Electrically disabled |
| INT cdx6500NCRBSCCfgV24ElectricalInterfaceOption | 1.3.6.1.4.1.449.2.1.2.1.1.17.1.17 | INTEGER | read-only | Specify the Pin 22 option:
RI - V.24 uses Pin 22 for Ring Indicator output signal
TM - V.24 uses Pin 22 for Test Mode input signal |
| INT cdx6500NCRBSCCfgHighSpeedElectricalInterfaceOption | 1.3.6.1.4.1.449.2.1.2.1.1.17.1.18 | INTEGER | read-only | Specify the cable type:
NONE - V.35/V.36/X.21 DCE with straight through cable
XOVER - V.35/V.36/X.21 DCE with crossover adapter cable |
| cdx6500PCTNCRBSCDeviceGroup | 1.3.6.1.4.1.449.2.1.2.1.7 | | | |
| cdx6500PBCTNCRBSCDeviceTable | 1.3.6.1.4.1.449.2.1.2.1.7.1 | | not-accessible | A table of NCRBSC device configuration entries. |
| cdx6500PBCTNCRBSCDeviceEntry | 1.3.6.1.4.1.449.2.1.2.1.7.1.1 | | not-accessible | A NCRBSC Configuration Table entry. Each entry
contains the configuration parameters for a single
NCRBSC device. |
| INT cdx6500ncrbscDevPortNumber | 1.3.6.1.4.1.449.2.1.2.1.7.1.1.1 | INTEGER | read-only | The NCRBSC port accessing this device |
| INT cdx6500ncrbscDevEntry | 1.3.6.1.4.1.449.2.1.2.1.7.1.1.2 | INTEGER | read-only | The unique number for this specific port. |
| STR cdx6500ncrbscBSCControlUnitAddr | 1.3.6.1.4.1.449.2.1.2.1.7.1.1.3 | DisplayString | read-only | 0-2 Hex digits,
This is the Poll address of the Control Unit that supports
this device. It consists of two hexadecimal digits. Valid
ranges depend on device Character Set as follows:
EBCDIC: 40,C1,C2,C3,C4,C5,C6,C7,C8,C9,4A,4B,4C,4D,4E,4F,
50,D1,D2,D3,D4,D5,D6,D7,D8,D9,5A,5B,5C,5D,5E,5F
ASCII : 20,41,42,43,44,45,46,47,48,49,5B,2E,3C,28,2B,21,
26,4A,4B,4C,4D,4E,4F,50,51,52,5D,24,2A,29,3B,5E |
| STR cdx6500ncrbscDestControlUnitAddr | 1.3.6.1.4.1.449.2.1.2.1.7.1.1.4 | DisplayString | read-only | 0-3 Hex digits,
Specifies control unit address on remote PAD. Used with
Connection Request Mode = 2 or 3 |
| STR cdx6500ncrbscAutocallMnemonic | 1.3.6.1.4.1.449.2.1.2.1.7.1.1.5 | DisplayString | read-only | 0-2 Hex digits,
This mnemonic name is used if this device is configured
for AUTO or FAST calling. |
| INT cdx6500ncrbscDeviceEnabled | 1.3.6.1.4.1.449.2.1.2.1.7.1.1.6 | INTEGER | read-only | This parameter is used to enable or disable the operation
of this controller device.
yes - Enable device.
no - Disable device.
newvalNo - same functionality as 'no', new enumeration
added for RFC1155 compatibility. |
| cdx6500Statistics | 1.3.6.1.4.1.449.2.1.3 | | | |
| cdx6500StatProtocolGroup | 1.3.6.1.4.1.449.2.1.3.1 | | | |
| cdx6500PSTPortProtocolGroup | 1.3.6.1.4.1.449.2.1.3.1.1 | | | |
| cdx6500PPSTNCRBisyncTable | 1.3.6.1.4.1.449.2.1.3.1.1.17 | | not-accessible | A table of NCRBSC port statistics entries. |
| cdx6500ncrbscPortStatEntry | 1.3.6.1.4.1.449.2.1.3.1.1.17.1 | | not-accessible | A NCRBSC Port Statistic Table entry. Each entry
contains the statistics for a single NCRBSC port. |
| INT cdx6500ncrbscStatPortNumber | 1.3.6.1.4.1.449.2.1.3.1.1.17.1.1 | INTEGER | read-only | The NCRBSC port number described by this entry. |
| INT cdx6500ncrbscPortStatus | 1.3.6.1.4.1.449.2.1.3.1.1.17.1.2 | INTEGER | read-only | Port Status indicates whether or not the port
is switched on and is ready for operation. This value
may be one of :
up - Port is up and running.
down - port is down.
disabled - port has been disabled.
enabled - port has been enabled, but is not yet Up
busyOut - port has been set to be disabled as soon as
last active session is disestablished. No
new sessions will be established.
newvalDisabled - same functionality as 'disabled',
new enumeration added for RFC1155 compatibility. |
| STR cdx6500ncrbscPortState | 1.3.6.1.4.1.449.2.1.3.1.1.17.1.3 | DisplayString | read-only | Port State indicates what the port is actually in the
process of doing. This value may be one of :
INACTIVE - H/TPAD port inactive entered during boot.
WTPOLSERVE - TPAD is waiting for response to a poll.
WTSELRESP - TPAD is waiting for the response to a select.
WTDATARESP - H/TPAD is waiting for data to be acknowledged.
DATA - H/TPAD is in the process of sending/receiving
data.
SEL/POL - TPAD is about to select or poll a
controller. This is the most common state
for a TPAD.
SELECT - TPAD is about to select a device.
POLL - TPAD is about to poll a device.
WTENQRESP - H/TPAD is waiting for a NAK response to
an ENQ sent.
IDLE - HPAD is waiting for the host to send commands.
This is the most common state of the HPAD.
WTEOT - HPAD is waiting for an expected EOT from the
host.
FLUSHINGDATA - HPAD encountered an error in the message
received from the host. As a result,
the data is being flushed.
WTLCM - HPAD received a read/modify and is waiting for
the response from the TPAD. |
| INT cdx6500ncrbscPortSpeed | 1.3.6.1.4.1.449.2.1.3.1.1.17.1.4 | INTEGER | read-only | This is the speed of the port if clock is internal. If
clock is external, this is the detected clock speed. If
Port Speed is 0, clock is external, but clocking is not
being received from attatched device. |
| INT cdx6500ncrbscPortUtilIn | 1.3.6.1.4.1.449.2.1.3.1.1.17.1.5 | INTEGER | read-only | Percentage of port input bandwidth in use. |
| INT cdx6500ncrbscPortUtilOut | 1.3.6.1.4.1.449.2.1.3.1.1.17.1.6 | INTEGER | read-only | Percentage of Port output bandwidth in use. |
| CTR cdx6500ncrbscInMsgs | 1.3.6.1.4.1.449.2.1.3.1.1.17.1.7 | Counter | read-only | Number of message received since last node, port, or
statistics reset. |
| CTR cdx6500ncrbscOutMsgs | 1.3.6.1.4.1.449.2.1.3.1.1.17.1.8 | Counter | read-only | Number of message sent since last node, port, or
statistics reset. |
| CTR cdx6500ncrbscInChars | 1.3.6.1.4.1.449.2.1.3.1.1.17.1.9 | Counter | read-only | Number of characters received since last node, port, or
statistics reset. |
| CTR cdx6500ncrbscOutChars | 1.3.6.1.4.1.449.2.1.3.1.1.17.1.10 | Counter | read-only | Number of characters sent since last node, port, or
statistics reset. |
| INT cdx6500ncrbscCharRateIn | 1.3.6.1.4.1.449.2.1.3.1.1.17.1.11 | INTEGER | read-only | Number of characters received per second. |
| INT cdx6500ncrbscCharRateOut | 1.3.6.1.4.1.449.2.1.3.1.1.17.1.12 | INTEGER | read-only | Number of characters sent per second. |
| CTR cdx6500ncrbscCrcBccErrs | 1.3.6.1.4.1.449.2.1.3.1.1.17.1.13 | Counter | read-only | Number of CRC errors since last node, port, or
statistics reset. |
| INT cdx6500ncrbscRviRx | 1.3.6.1.4.1.449.2.1.3.1.1.17.1.14 | INTEGER | read-only | Accumulator, received RVI. |
| INT cdx6500ncrbscRviTx | 1.3.6.1.4.1.449.2.1.3.1.1.17.1.15 | INTEGER | read-only | Accumulator, transmitted RVI. |
| INT cdx6500ncrbscWackRx | 1.3.6.1.4.1.449.2.1.3.1.1.17.1.16 | INTEGER | read-only | Accumulator, recevied WACK. |
| INT cdx6500ncrbscNconvRxMax | 1.3.6.1.4.1.449.2.1.3.1.1.17.1.17 | INTEGER | read-only | Maximum number of conversation messages received
from device within a poll or select. |
| INT cdx6500ncrbscNconvTxMax | 1.3.6.1.4.1.449.2.1.3.1.1.17.1.18 | INTEGER | read-only | Maximum number of conversation messages sent to
device within a poll or select. |
| INT cdx6500ncrbscNgroupRxMax | 1.3.6.1.4.1.449.2.1.3.1.1.17.1.19 | INTEGER | read-only | Maximum number of grouping messages received
from device within a poll or select. |
| INT cdx6500ncrbscNgroupTxMax | 1.3.6.1.4.1.449.2.1.3.1.1.17.1.20 | INTEGER | read-only | Maximum number of grouping messages sent to
device within a poll or select. |
| INT cdx6500ncrbscLongRespTime | 1.3.6.1.4.1.449.2.1.3.1.1.17.1.21 | INTEGER | read-only | Longest response time |
| INT cdx6500ncrbscAverageRespTime | 1.3.6.1.4.1.449.2.1.3.1.1.17.1.22 | INTEGER | read-only | Average response time |
| INT cdx6500ncrbscRviForce | 1.3.6.1.4.1.449.2.1.3.1.1.17.1.23 | INTEGER | read-only | Number of RVI's sent to device from the polling algorithm. |