| OID symbolic | OID numeric | Type | Access | Description |
| myInterfaceMIB | 1.3.6.1.4.1.171.10.97.2.10 | | | This module defines my interface mibs. |
| myIfConfigMIBObjects | 1.3.6.1.4.1.171.10.97.2.10.1 | | | |
| myIfTable | 1.3.6.1.4.1.171.10.97.2.10.1.1 | | not-accessible | list of interface basic configuration objects. |
| myIfEntry | 1.3.6.1.4.1.171.10.97.2.10.1.1.1 | | not-accessible | Entry contains interface basic configurations. |
| IFI myIfIndex | 1.3.6.1.4.1.171.10.97.2.10.1.1.1.1 | IfIndex | read-only | |
| INT myIfPortType | 1.3.6.1.4.1.171.10.97.2.10.1.1.1.2 | INTEGER | read-only | Port type of this port, list as above.
port100MBASEFX indicates that port is port100MBASEFXL or port100MBASEFXS,
and system doesn't distinguish.
port1000MBASEFX indicates that port is port1000MBASEFLX or port1000MBASEFSX,
and system doesn't distinguish.
This attribute apply physical port |
| INT myIfFlowControlAdminStatus | 1.3.6.1.4.1.171.10.97.2.10.1.1.1.3 | INTEGER | read-write | Flow control of a port management status.
This attribute apply physical port and aggreate port |
| ENA myIfFlowControlOperStatus | 1.3.6.1.4.1.171.10.97.2.10.1.1.1.4 | EnabledStatus | read-only | Oper status: after the negotiation between two ports connetted
the flow contrl status.
This attribute apply physical port and aggreate port |
| INT myIfAdminSpeed | 1.3.6.1.4.1.171.10.97.2.10.1.1.1.5 | INTEGER | read-write | port speed settings.
This attribute apply physical port and aggreate port |
| INT myIfAdminDuplex | 1.3.6.1.4.1.171.10.97.2.10.1.1.1.6 | INTEGER | read-write | port duplex settings.
This attribute apply physical port and aggreate port |
| INT myIfOperSpeed | 1.3.6.1.4.1.171.10.97.2.10.1.1.1.7 | INTEGER | read-only | After two port have negotiated the speed status,and this object
is the working speed status. while the port link status is down ,
then the speed status is unknown(4).
This attribute apply physical port and aggreate port |
| INT myIfOperDuplex | 1.3.6.1.4.1.171.10.97.2.10.1.1.1.8 | INTEGER | read-only | After two port have negotiated the duplex status, and this object
is the working duplex status. while the port link status is down ,
then the speed status is unknown(3).
This attribute apply physical port and aggreate port |
| ENA myIfManageStatus | 1.3.6.1.4.1.171.10.97.2.10.1.1.1.9 | EnabledStatus | read-write | Management status of the interface. |
| IP myIfIpBroadcast | 1.3.6.1.4.1.171.10.97.2.10.1.1.1.10 | IpAddress | read-write | Broadcast address of the interface. if broadcast address not configured on interface, return 0.0.0.0 |
| INT myIfLayer | 1.3.6.1.4.1.171.10.97.2.10.1.1.1.11 | INTEGER | read-write | |
| INT myIfMode | 1.3.6.1.4.1.171.10.97.2.10.1.1.1.12 | INTEGER | read-write | This value is meaning for only physical port and aggreate port |
| I32 myIfCounterClear | 1.3.6.1.4.1.171.10.97.2.10.1.1.1.13 | Integer32 | read-write | Setting its to any value but 0, will clear counters of this interface.
Setting its value to 0 will cause no action of the agent. and when
query will always return 0. |
| CON myIfEntryStatus | 1.3.6.1.4.1.171.10.97.2.10.1.1.1.14 | ConfigStatus | read-create | Status of this entry, set this object to valid will create a interface,
and set its value to invalid will delete the interface of this entry. |
| INT myIfMediumType | 1.3.6.1.4.1.171.10.97.2.10.1.1.1.15 | INTEGER | read-write | Port medium type of this port,fiber or copper. |
| myIfIpTable | 1.3.6.1.4.1.171.10.97.2.10.1.2 | | not-accessible | A list of interface ip configuration entries. |
| myIfIpEntry | 1.3.6.1.4.1.171.10.97.2.10.1.2.1 | | not-accessible | An entry containing configuration information applicable
to a Layer3 interface. |
| IFI myIfIpIfIndex | 1.3.6.1.4.1.171.10.97.2.10.1.2.1.1 | IfIndex | read-only | A unique value, for each Layer3 interface. |
| INT myIfIpId | 1.3.6.1.4.1.171.10.97.2.10.1.2.1.2 | INTEGER | read-only | Type of interface ip address. |
| IP myIfIp | 1.3.6.1.4.1.171.10.97.2.10.1.2.1.3 | IpAddress | read-only | Ip address of the interface myIfIndex refer to. |
| IP myIfIpMask | 1.3.6.1.4.1.171.10.97.2.10.1.2.1.4 | IpAddress | read-write | Ip mask of the interface ip address. |
| ROW myIfIpEntryStatus | 1.3.6.1.4.1.171.10.97.2.10.1.2.1.5 | RowStatus | read-create | entry status of this entry. and the means in this enviraments can
reffer to the text-convention definition of the RowStatus. |
| myIfStatusTable | 1.3.6.1.4.1.171.10.97.2.10.1.3 | | not-accessible | list of interface status. Status information include some error state and
result of examining to the interface,etc. |
| myIfStatusEntry | 1.3.6.1.4.1.171.10.97.2.10.1.3.1 | | not-accessible | Entry contains interface status information. |
| IFI myIfStatusIndex | 1.3.6.1.4.1.171.10.97.2.10.1.3.1.1 | IfIndex | read-only | |
| I32 myIfStatusLoopBackExamine | 1.3.6.1.4.1.171.10.97.2.10.1.3.1.2 | Integer32 | read-write | Setting its to any value but 0, will Checking whether this port or aggreate can
receive and send packets normally, It indicates that port or aggreate is normal
if opertion is success.
Setting its value to 0 will cause no action of the agent. and when
query will always return 0.
This attribute apply physical port and aggreate port |
| INT myIfErrorStatus | 1.3.6.1.4.1.171.10.97.2.10.1.3.1.3 | INTEGER | read-only | Port's error status information |
| I32 myIfLineDetect | 1.3.6.1.4.1.171.10.97.2.10.1.3.1.4 | Integer32 | read-only | When reading this object, system detects the quality of line connecting the port.
Detect whether the line is broken or short circuit or not.
The meaning of the obtained value:
Return value=N*10000000+M
N stands for the line state (0: perfect; 1: break; 2: short circuit)
M stands for the location of the break or short circuit in the line(distance from the switch port, in metre)
If the line is perfect, the value is zero. |
| I32 myGlobalIfDisableRecovery | 1.3.6.1.4.1.171.10.97.2.10.1.4 | Integer32 | read-write | Setting its to any value but 0, the interfaces which is shutted down by
some error happened will recovery from disabled status .
Setting its value to 0 will cause no action of the agent. and when
query will always return 0.
This attribute apply physical port and aggreate port |
| myPortTypeChooseTable | 1.3.6.1.4.1.171.10.97.2.10.1.5 | | not-accessible | Table of entrance to choose port type. |
| myPortTypeChooseEntry | 1.3.6.1.4.1.171.10.97.2.10.1.5.1 | | not-accessible | Entrance to choose port type. |
| IFI myPortTypeChooseIndex | 1.3.6.1.4.1.171.10.97.2.10.1.5.1.1 | IfIndex | read-only | The logic port number. |
| INT myPortTypeChooseType | 1.3.6.1.4.1.171.10.97.2.10.1.5.1.2 | INTEGER | read-only | The chosen port type. This object is used to choose one of the multiple physical ports of different types,
when the same logical port is correspondent with them.
Apply this attribute to the physical port only. |
| myIfMTUTable | 1.3.6.1.4.1.171.10.97.2.10.1.6 | | not-accessible | Access table of MTU on interface. |
| myIfMTUEntry | 1.3.6.1.4.1.171.10.97.2.10.1.6.1 | | not-accessible | Interfac MTU access. |
| IFI myIfMTUIndex | 1.3.6.1.4.1.171.10.97.2.10.1.6.1.1 | IfIndex | read-only | Interface number |
| I32 myIfMTU | 1.3.6.1.4.1.171.10.97.2.10.1.6.1.2 | Integer32 | read-write | Interface MTU. |
| myIfAvailableBWTable | 1.3.6.1.4.1.171.10.97.2.10.1.7 | | not-accessible | Access table of Available Bandwidth on interface. |
| myIfAvailableBWEntry | 1.3.6.1.4.1.171.10.97.2.10.1.7.1 | | not-accessible | Interfac available bandwidth access. |
| IFI myIfAvailableBWIfIndex | 1.3.6.1.4.1.171.10.97.2.10.1.7.1.1 | IfIndex | read-only | Interface number |
| GAU myIfAvailableBWIfBWEx | 1.3.6.1.4.1.171.10.97.2.10.1.7.1.2 | Gauge | read-only | Interface available bandwidth(bit). |
| myInterfaceTraps | 1.3.6.1.4.1.171.10.97.2.10.2 | | | |
| INT lineDetectStatus | 1.3.6.1.4.1.171.10.97.2.10.2.1 | INTEGER | accessible-for-notify | The type of storm of interface |
| I32 lineDetectPosition | 1.3.6.1.4.1.171.10.97.2.10.2.2 | Integer32 | accessible-for-notify | Location where the break or short circuit in the line happens
(Distance from the switch port, in metre.) |
| NTF lineQualityDetect | 1.3.6.1.4.1.171.10.97.2.10.2.3 | | | The notification of discovering a break or short circuit in the line,
or restoring the line to the normal state. |
| myInterfaceMIBConformance | 1.3.6.1.4.1.171.10.97.2.10.3 | | | |
| myInterfaceMIBCompliances | 1.3.6.1.4.1.171.10.97.2.10.3.1 | | | |
| myInterfaceMIBCompliance | 1.3.6.1.4.1.171.10.97.2.10.3.1.1 | | | The compliance statement for entities which implement
the My Interface MIB |
| myInterfaceMIBGroups | 1.3.6.1.4.1.171.10.97.2.10.3.2 | | | |
| myInterfaceMIBGroup | 1.3.6.1.4.1.171.10.97.2.10.3.2.1 | | | A collection of objects providing interface basic configure . |
| myPortTypeChooseMibGroup | 1.3.6.1.4.1.171.10.97.2.10.3.2.2 | | | Information collection of choosing port type. |
| myIfMTUMibGroup | 1.3.6.1.4.1.171.10.97.2.10.3.2.3 | | | Interface MTU information collection. |
| myIfLineDetectGroup | 1.3.6.1.4.1.171.10.97.2.10.3.2.4 | | | Information collection of line quality detection. |
| myIfAvailableBWMibGroup | 1.3.6.1.4.1.171.10.97.2.10.3.2.5 | | | Interface available bandwidth information collection. |