Start monitoring vendor-neutral, standards-based MIB, any SNMPv3-capable network device (SNMP engine identity/boot/clock status) with a free 30-day trial of IPNetwork Monitor. Import MIBs, browse SNMP OIDs, create custom SNMP monitors, configure alerts, and monitor any SNMP-enabled network device from a single console.
What Is MICOM-RFC1604-MIB?
This is a MICOM Communications vendor MIB module providing MICOM-specific extensions to the standard RFC 1604 Frame Relay DTE (Data Terminal Equipment) MIB. It exposes per-port frame relay logical port (Lport) configuration such as numbering plan, DLCI addressing length, and VC signaling protocol, plus a management VC signaling table tracking signaling procedure and network-side timer (N392) settings. Its monitoring value is largely in frame relay service configuration/signaling health, letting an operator confirm signaling protocol and procedure parameters are consistent for a frame relay port, which affects whether PVC/SVC signaling operates correctly. As its name states, it is explicitly built as an extension to the IETF RFC 1604 Frame Relay DTE MIB, adding MICOM-specific fields on top of that standard. It would be deployed on MICOM frame relay access equipment interoperating with carrier frame relay networks. Engineers can download the MICOM-RFC1604-MIB file directly to load it into their MIB browser.
IPNetwork Monitor allows you to monitor SNMP objects defined in MICOM-RFC1604-MIB. Use the built-in SNMP Monitoring Browser to explore available variables, view their current values and descriptions, and select the objects you want to monitor. You can then create SNMP monitors, configure thresholds, and receive alerts when monitored values change.
Supported Devices
- MICOM frame relay access equipment
Monitoring Examples
An operator would poll mcmFrLportTable / mcmFrLportEntry indexed by mcmFrLportIfIndex to check mcmFrLportType and mcmFrLportVCSigProtocol, confirming the frame relay port is configured with the expected signaling protocol for its carrier connection. mcmFrLportAddrDLCILen and mcmFrLportNumPlan would be checked when diagnosing a DLCI addressing mismatch. mcmFrMgtVCSigTable / Entry with mcmFrMgtVCSigProced and mcmFrMgtVCSigNetN392 let an admin verify signaling procedure and retry-counter settings affecting PVC/SVC establishment reliability.
What Can Be Monitored
- frame relay port type/signaling protocol
- DLCI addressing length
- numbering plan
- VC signaling procedure and N392 timer
This MIB depends on
Related MIBs
Imported Objects
OIDs
| OID symbolic | OID numeric | Type | Access | Description |
|---|---|---|---|---|
| INT mcmFrLportAddrDLCILen | 1.3.6.1.4.1.335.1.4.8.1.1.1.4 | INTEGER | read-only | NAME = ; DESC = The value of this object identifies \ the Q.922 Address field length and \ DLCI length for this UNI logical \ port. (Operational); HELP = ; CAPABILITIES = ; |
| mcmFrLportEntry | 1.3.6.1.4.1.335.1.4.8.1.1.1 | not-accessible | NAME = ; DESC = An entry in the Frame Relay Logical \ Port Information table (Operational).; HELP = ; CAPABILITIES = ; | |
| INT mcmFrLportIfIndex | 1.3.6.1.4.1.335.1.4.8.1.1.1.1 | INTEGER | read-only | NAME = ; DESC = The ifIndex of the local DCE interface. \ (Analogous to the ifIndex pointer in the \ MIB II Interfaces Group, but specific to \ the FR Logical Port info table.) (Operational); HELP = ; CAPABILITIES = ; |
| INT mcmFrLportNumPlan | 1.3.6.1.4.1.335.1.4.8.1.1.1.2 | INTEGER | read-only | NAME = ; DESC = The value of this object identifies \ the network address numbering plan \ for this UNI logical port. \ (Operational); HELP = The network address is the object ifPhysAddress. \ The value 'none' implies that there is \ no ifPhysAddress (the SNMP proxy-agent \ will return an octet string of zero \ length for ifPhysAddress). The value \ 'other' means that an address has been \ assigned to this interface, but the \ numbering plan is not enumerated here. ; CAPABILITIES = ; |
| mcmFrLportTable | 1.3.6.1.4.1.335.1.4.8.1.1 | not-accessible | NAME = ; DESC = The Frame Relay Logical Port Information \ table (Operational).; HELP = ; CAPABILITIES = NET_CFG, VPN_CFG; | |
| INT mcmFrLportType | 1.3.6.1.4.1.335.1.4.8.1.1.1.3 | INTEGER | read-only | NAME = ; DESC = The value of this object identifies \ the type of network interface for this \ logical port. (Operational); HELP = ; CAPABILITIES = ; |
| INT mcmFrLportVCSigProtocol | 1.3.6.1.4.1.335.1.4.8.1.1.1.5 | INTEGER | read-only | NAME = ; DESC = The value of this object identifies \ the Local In-Channel Signaling Protocol \ that is used for this frame relay UNI \ logical port. (Operational); HELP = ; CAPABILITIES = ; |
| INT mcmFrMgtVCSigCntrAction | 1.3.6.1.4.1.335.1.4.8.2.1.1.2 | INTEGER | write-only | NAME = ; DESC = Setting this object to reset(1) will \ zero the values of a specific row of \ counters in the FR Management VC \ Signaling Parameters table.; HELP = When set to reset(1), a row containing \ the following counter objects are reset: \ mcmFrMgtVCSigNetLinkRelErrors \ mcmFrMgtVCSigNetProtErrors \ mcmFrMgtVCSigNetChanInactive; CAPABILITIES = ; |
| mcmFrMgtVCSigCntrEntry | 1.3.6.1.4.1.335.1.4.8.2.1.1 | not-accessible | NAME = ; DESC = An entry in the Frame Relay Management VC \ Signaling Parameters counter reset table.; HELP = ; CAPABILITIES = ; | |
| INT mcmFrMgtVCSigCntrIfIndex | 1.3.6.1.4.1.335.1.4.8.2.1.1.1 | INTEGER | read-only | NAME = ; DESC = The ifIndex of the FR Management VC Signaling \ Parameters table. This index specifies \ the particular row of counter objects to \ be reset.; HELP = ; CAPABILITIES = ; |
| mcmFrMgtVCSigCntrTable | 1.3.6.1.4.1.335.1.4.8.2.1 | not-accessible | NAME = ; DESC = The Frame Relay Management VC Signaling \ Parameters counter reset table.; HELP = ; CAPABILITIES = NET_OPER, VPN_OPER; | |
| mcmFrMgtVCSigEntry | 1.3.6.1.4.1.335.1.4.8.1.2.1 | not-accessible | NAME = ; DESC = An entry in the Frame Relay Management \ VC Signaling Parameters and Errors table. (Operational); HELP = ; CAPABILITIES = ; | |
| INT mcmFrMgtVCSigIfIndex | 1.3.6.1.4.1.335.1.4.8.1.2.1.1 | INTEGER | read-only | NAME = ; DESC = The ifIndex of the local DCE interface. \ (Operational); HELP = (Analogous to the ifIndex pointer in the \ MIB II Interfaces Group but specific to \ the FR Mgmt VC Sig table.); CAPABILITIES = ; |
| CTR mcmFrMgtVCSigNetChanInactive | 1.3.6.1.4.1.335.1.4.8.1.2.1.8 | Counter | read-only | NAME = ; DESC = The number of times the network-side channel \ was declared inactive.; (Operational) \ ; HELP = If the logical port is not performing \ network-side procedures, then this value \ is equal to noSuchName. Note: no Configuration \ counterpart for this object.; CAPABILITIES = ; |
| CTR mcmFrMgtVCSigNetLinkRelErrors | 1.3.6.1.4.1.335.1.4.8.1.2.1.6 | Counter | read-only | NAME = ; DESC = The number of network-side local in-channel \ signaling link reliability errors. \ (Operational); HELP = Marks non-receipt of Status/Status Enquiry \ messages or invalid sequence numbers \ in a Link Integrity Verification Information \ Element for this UNI logical port. \ If the logical port is not performing \ network-side procedures, then this value is equal \ to noSuchName. Note: no Configuration counterpart \ for this object.; CAPABILITIES = ; |
| INT mcmFrMgtVCSigNetN392 | 1.3.6.1.4.1.335.1.4.8.1.2.1.3 | INTEGER | read-only | NAME = ; DESC = The value of this object identifies \ the Network-side N392 error threshold \ value for this UNI logical port (nN2 for LMI). \ (Operational); HELP = If the logical port is not performing \ network-side procedures, then this value is \ equal to noSuchName. This object \ applies to Q.933 Annex A, T1.617 \ Annex D, and LMI.; CAPABILITIES = ; |
| INT mcmFrMgtVCSigNetN393 | 1.3.6.1.4.1.335.1.4.8.1.2.1.4 | INTEGER | read-only | NAME = ; DESC = The value of this object identifies \ the Network-side N393 monitored events \ count value for this UNI logical port \ (nN3 for LMI). (Operational); HELP = If the logical port is not performing \ network-side procedures, then this value is equal \ to noSuchName. This object \ applies to Q.933 Annex A, T1.617 \ Annex D, and LMI.; CAPABILITIES = ; |
| CTR mcmFrMgtVCSigNetProtErrors | 1.3.6.1.4.1.335.1.4.8.1.2.1.7 | Counter | read-only | NAME = ; DESC = The number of network-side local in-channel \ signaling protocol errors. (Operational); HELP = Types include protocol discriminator, message type, call reference, \ and mandatory information element errors) \ for this UNI logical port. If \ the logical port is not performing \ network-side procedures, then this value is equal \ to noSuchName. \ Note: no Configuration counterpart for this object.; CAPABILITIES = ; |
| INT mcmFrMgtVCSigNetT392 | 1.3.6.1.4.1.335.1.4.8.1.2.1.5 | INTEGER | read-only | NAME = ; DESC = The value of this object identifies \ the Network-side T392 polling verification \ timer value for this UNI logical port \ (nT2 for LMI). (Operational); HELP = This value is in seconds. \ If the logical port is not performing\ network-side procedures, \ then this value is equal to noSuchName. \ This object applies to Q.933 Annex A, \ T1.617 Annex D, and LMI.; CAPABILITIES = ; |
| INT mcmFrMgtVCSigProced | 1.3.6.1.4.1.335.1.4.8.1.2.1.2 | INTEGER | read-only | NAME = ; DESC = The value of this object identifies \ the Local In-Channel Signaling Procedure \ that is used for this UNI logical \ port. (Operational); HELP = The UNI logical port can \ be performing only user-to-network \ network-side procedures.; CAPABILITIES = ; |
| mcmFrMgtVCSigTable | 1.3.6.1.4.1.335.1.4.8.1.2 | not-accessible | NAME = ; DESC = The Frame Relay Management VC \ Signaling Parameters and Errors table. (Operational); HELP = ; CAPABILITIES = NET_CFG, VPN_CFG; | |
| INT mcmFrPVCEndptCntrAction | 1.3.6.1.4.1.335.1.4.8.2.2.1.3 | INTEGER | write-only | NAME = ; DESC = Setting this object to reset(1) will \ zero the values of a specific row of \ counters in the FR PVC End-Point table; HELP = When set to reset(1), a row containing \ the following counter objects are reset: \ mcmFrPVCEndptInFrames \ mcmFrPVCEndptOutFrames \ mcmFrPVCEndptInDEFrames \ mcmFrPVCEndptInExcessFrames \ mcmFrPVCEndptOutExcessFrames \ mcmFrPVCEndptInDiscards \ mcmFrPVCEndptInOctets \ mcmFrPVCEndptOutOctets; CAPABILITIES = ; |
| INT mcmFrPVCEndptCntrDLCIIndex | 1.3.6.1.4.1.335.1.4.8.2.2.1.2 | INTEGER | read-only | NAME = ; DESC = The DLCI Index of the FR PVC End-Point \ table. This index (in conjunction with \ the ifIndex) specifies the particular \ row of counter objects to be reset.; HELP = ; CAPABILITIES = ; |
| mcmFrPVCEndptCntrEntry | 1.3.6.1.4.1.335.1.4.8.2.2.1 | not-accessible | NAME = ; DESC = An entry in the Frame Relay PVC End-Point \ Group counter reset table.; HELP = ; CAPABILITIES = ; | |
| INT mcmFrPVCEndptCntrIfIndex | 1.3.6.1.4.1.335.1.4.8.2.2.1.1 | INTEGER | read-only | NAME = ; DESC = The ifIndex of the FR PVC End-Point \ table. This index (in conjunction with \ the DLCI index) specifies the particular \ row of counter objects to be reset.; HELP = ; CAPABILITIES = ; |
| mcmFrPVCEndptCntrTable | 1.3.6.1.4.1.335.1.4.8.2.2 | not-accessible | NAME = ; DESC = The Frame Relay PVC End-Point Group \ counter reset table.; HELP = ; CAPABILITIES = NET_OPER, VPN_OPER; | |
| INT mcmFrPVCEndptDLCIIndex | 1.3.6.1.4.1.335.1.4.8.1.3.1.2 | INTEGER | read-only | NAME = ; DESC = The value of this object is equal to the \ DLCI value for this PVC end-point. (Operational); HELP = ; CAPABILITIES = ; |
| mcmFrPVCEndptEntry | 1.3.6.1.4.1.335.1.4.8.1.3.1 | not-accessible | NAME = ; DESC = An entry in the Frame Relay PVC End-point \ table. (Operational); HELP = ; CAPABILITIES = ; | |
| INT mcmFrPVCEndptIfIndex | 1.3.6.1.4.1.335.1.4.8.1.3.1.1 | INTEGER | read-only | NAME = ; DESC = The ifIndex of the local DCE interface. \ (Operational); HELP = (Analogous to the ifIndex pointer in the \ MIB II Interfaces Group but specific to \ the PVC end-point table.); CAPABILITIES = ; |
| INT mcmFrPVCEndptInBc | 1.3.6.1.4.1.335.1.4.8.1.3.1.4 | INTEGER | read-only | NAME = ; DESC = The committed burst size (Bc) in bits \ for this PVC end-point data sent into \ frame relay network.(Operational); HELP = ; CAPABILITIES = ; |
| INT mcmFrPVCEndptInBe | 1.3.6.1.4.1.335.1.4.8.1.3.1.5 | INTEGER | read-only | NAME = ; DESC = The committed excess size (Be) in bits \ for this PVC end-point data sent into \ frame relay network. (Operational); HELP = ; CAPABILITIES = ; |
| INT mcmFrPVCEndptInCIR | 1.3.6.1.4.1.335.1.4.8.1.3.1.6 | INTEGER | read-only | NAME = ; DESC = The committed information rate (CIR) in bits/sec \ for this PVC end-point data sent into \ frame relay network.; HELP = ; CAPABILITIES = ; |
| CTR mcmFrPVCEndptInDEFrames | 1.3.6.1.4.1.335.1.4.8.1.3.1.13 | Counter | read-only | NAME = ; DESC = The number of frames received by the \ network (ingress) with the DE bit set \ to (1) for this PVC end-point. (Operational); HELP = Note: no Configuration counterpart for this object.; CAPABILITIES = ; |
| CTR mcmFrPVCEndptInDiscards | 1.3.6.1.4.1.335.1.4.8.1.3.1.16 | Counter | read-only | NAME = ; DESC = The number of frames received by the \ the network (ingress) that were discarded \ due to traffic enforcement for this \ PVC end-point. (Operational); HELP = Note: no Configuration counterpart for this object.; CAPABILITIES = ; |
| CTR mcmFrPVCEndptInExcessFrames | 1.3.6.1.4.1.335.1.4.8.1.3.1.14 | Counter | read-only | NAME = ; DESC = The number of frames received by the \ network (ingress) for this PVC end-point \ which were treated as excess traffic. \ (Operational); HELP = Frames which are sent to the network \ with DE set to zero are treated as \ excess when more than Bc bits are submitted \ to the network during the Committed \ Information Rate Measurement Interval \ (Tc). Excess traffic may or may not \ be discarded at the ingress if more \ than Bc + Be bits are submitted to \ the network during Tc. Traffic discarded \ at the ingress is not recorded in \ mcmFrPVCEndptInExcessFrames. \ Frames which are sent to the network \ with DE set to one are also treated \ as excess traffic. \ Note: no Configuration counterpart for this object.; CAPABILITIES = ; |
| CTR mcmFrPVCEndptInFrames | 1.3.6.1.4.1.335.1.4.8.1.3.1.11 | Counter | read-only | NAME = ; DESC = The number of frames received by the \ network (ingress) for this PVC end-point. \ (Operational); HELP = This includes any frames discarded \ by the network due to submitting more \ than Bc + Be data or due to any network \ congestion recovery procedures. \ Note: no Configuration counterpart for this object.; CAPABILITIES = ; |
| INT mcmFrPVCEndptInMaxFrameSize | 1.3.6.1.4.1.335.1.4.8.1.3.1.3 | INTEGER | read-only | NAME = ; DESC = The largest frame relay information field \ in octets for this PVC end-point data sent \ into the network. (Operational); HELP = The value must be \ less than or equal to the corresponding \ ifMtu (mcmFrPhyPortMtuSize) for this \ Frame Relay UNI logical port.; CAPABILITIES = ; |
| CTR mcmFrPVCEndptInOctets | 1.3.6.1.4.1.335.1.4.8.1.3.1.17 | Counter | read-only | NAME = ; DESC = The number of octets received by the \ network (ingress) for this PVC end-point. \ (Operational); HELP = This counter should only count octets \ from the beginning of the frame relay \ header field to the end of user data. \ If the network supporting Frame Relay \ cannot count octets, then this count \ should be an approximation. \ Note: no Configuration counterpart for this object.; CAPABILITIES = ; |
| INT mcmFrPVCEndptOutBc | 1.3.6.1.4.1.335.1.4.8.1.3.1.8 | INTEGER | read-only | NAME = ; DESC = (Operational); HELP = The committed burst size (Bc) in bits \ for this PVC end-point data received from \ frame relay network.; CAPABILITIES = ; |
| INT mcmFrPVCEndptOutBe | 1.3.6.1.4.1.335.1.4.8.1.3.1.9 | INTEGER | read-only | NAME = ; DESC = The committed excess size (Be) in bits \ for this PVC end-point data received from \ frame relay network. (Operational); HELP = ; CAPABILITIES = ; |
| INT mcmFrPVCEndptOutCIR | 1.3.6.1.4.1.335.1.4.8.1.3.1.10 | INTEGER | read-only | NAME = ; DESC =The committed information rate (CIR) in bits/sec \ for this PVC end-point data received from \ frame relay network.(Operational); HELP = ; CAPABILITIES = ; |
| CTR mcmFrPVCEndptOutExcessFrames | 1.3.6.1.4.1.335.1.4.8.1.3.1.15 | Counter | read-only | NAME = ; DESC = The number of frames sent by the network \ (egress) for this PVC end-point which \ were treated as excess traffic. (The \ DE bit may be set to one.) (Operational); HELP = Note: no Configuration counterpart for this object.; CAPABILITIES = ; |
| CTR mcmFrPVCEndptOutFrames | 1.3.6.1.4.1.335.1.4.8.1.3.1.12 | Counter | read-only | NAME = ; DESC = The number of frames sent by the network \ (egress) regardless of whether they \ are Bc or Be frames for this PVC end-point. (Operational) \ ; HELP = Note: no Configuration counterpart for this object.; CAPABILITIES = ; |
| INT mcmFrPVCEndptOutMaxFrameSize | 1.3.6.1.4.1.335.1.4.8.1.3.1.7 | INTEGER | read-only | NAME = ; DESC = The largest frame relay information field \ in octets for this PVC end-point data received \ from the network. (Operational); HELP = ; CAPABILITIES = ; |
| CTR mcmFrPVCEndptOutOctets | 1.3.6.1.4.1.335.1.4.8.1.3.1.18 | Counter | read-only | NAME = ; DESC = The number of octets sent by the network \ (egress) for this PVC end-point. (Operational); ; HELP = This counter should only count octets from \ the beginning of the frame relay header \ field to the end of user data. If \ the network supporting Frame Relay \ can not count octets, then this count \ should be an approximation. Note: no Configuration counterpart for this object.; CAPABILITIES = ; |
| mcmFrPVCEndptTable | 1.3.6.1.4.1.335.1.4.8.1.3 | not-accessible | NAME = ; DESC = The Frame Relay PVC End-Point table. \ (Operational); HELP = This table contains the \ traffic parameters and statistics for \ a PVC end-point.; CAPABILITIES = NET_CFG, VPN_CFG; | |
| micom_rfc1604 | 1.3.6.1.4.1.335.1.4.8 | |||
| INT nvmFrLportAddrDLCILen | 1.3.6.1.4.1.335.1.4.8.1.4.1.4 | INTEGER | read-only | NAME = ; DESC = The value of this object identifies \ the Q.922 Address field length and \ DLCI length for this UNI logical port.\ (Always twoOctets10Bits(1) for Release 1.1). \ (Configuration); HELP = This object has temporarily been assigned read-only \ access. Read-write access will be assigned when \ other enumeration values are supported.); CAPABILITIES = ; |
| nvmFrLportEntry | 1.3.6.1.4.1.335.1.4.8.1.4.1 | not-accessible | NAME = ; DESC = An entry in the Frame Relay Logical \ Port Information table (Configuration).; HELP = ; CAPABILITIES = ; | |
| INT nvmFrLportIfIndex | 1.3.6.1.4.1.335.1.4.8.1.4.1.1 | INTEGER | read-only | NAME = ; DESC = The ifIndex of the local DCE interface. \ (Analogous to the ifIndex pointer in the \ MIB II Interfaces Group but specific to \ the FR Logical Port info table..) (Configuration); HELP = ; CAPABILITIES = ; |
| INT nvmFrLportNumPlan | 1.3.6.1.4.1.335.1.4.8.1.4.1.2 | INTEGER | read-only | NAME = ; DESC = The value of this object identifies \ the network address numbering plan \ for this UNI logical port. \ (Configuration); HELP = The network address is the object ifPhysAddress. \ The value 'none' implies that there is \ no ifPhysAddress (the SNMP proxy-agent \ will return an octet string of zero \ length for ifPhysAddress). The value \ 'other' means that an address has been \ assigned to this interface, but the \ numbering plan is not enumerated here. \ (For Release 1.1, only none(4) will be supported. \ This object has temporarily been assigned read-only \ access. Read-write access will be assigned when \ other enumeration values are supported.) ; CAPABILITIES = ; |
| nvmFrLportTable | 1.3.6.1.4.1.335.1.4.8.1.4 | not-accessible | NAME = ; DESC = The Frame Relay Logical Port Information \ table (Configuration).; HELP = NET_CFG, VPN_CFG; CAPABILITIES = ; | |
| INT nvmFrLportType | 1.3.6.1.4.1.335.1.4.8.1.4.1.3 | INTEGER | read-only | NAME = ; DESC = The value of this object identifies \ the type of network interface for this \ logical port. (Always uni(1) for Release 1.1). \ (Configuration); HELP = This object has temporarily been assigned read-only \ access. Read-write access will be assigned when \ other enumeration values are supported. ; CAPABILITIES = ; |
| INT nvmFrLportVCSigProtocol | 1.3.6.1.4.1.335.1.4.8.1.4.1.5 | INTEGER | read-write | NAME = ; DESC = The value of this object identifies \ the Local In-Channel Signaling Protocol \ that is used for this frame relay UNI \ logical port. (Configuration); HELP = ; CAPABILITIES = ; |
| nvmFrMgtVCSigEntry | 1.3.6.1.4.1.335.1.4.8.1.5.1 | not-accessible | NAME = ; DESC = An entry in the Frame Relay Management \ VC Signaling Parameters and Errors table. (Configuration); HELP = ; CAPABILITIES = ; | |
| INT nvmFrMgtVCSigIfIndex | 1.3.6.1.4.1.335.1.4.8.1.5.1.1 | INTEGER | read-only | NAME = ; DESC = The ifIndex of the local DCE interface. \ (Analogous to the ifIndex pointer in the \ MIB II Interfaces Group but specific to \ the FR Mgmt VC Sig table.) (Configuration); HELP = ; CAPABILITIES = ; |
| INT nvmFrMgtVCSigNetN392 | 1.3.6.1.4.1.335.1.4.8.1.5.1.3 | INTEGER | read-write | NAME = ; DESC = The value of this object identifies \ the Network-side N392 error threshold \ value for this UNI logical port (nN2 for LMI). \ (Configuration); HELP = If the logical port is not performing \ network-side procedures, then this value is \ equal to noSuchName. This object \ applies to Q.933 Annex A, T1.617 \ Annex D, and LMI.; CAPABILITIES = ; |
| INT nvmFrMgtVCSigNetN393 | 1.3.6.1.4.1.335.1.4.8.1.5.1.4 | INTEGER | read-only | NAME = ; DESC = The value of this object identifies \ the Network-side N393 monitored events \ count value for this UNI logical port \ (nN3 for LMI). (Configuration); HELP = If the logical port is not performing \ network-side procedures, then this value is equal \ to noSuchName. This object applies to Q.933 \ Annex A, T1.617 Annex D, and LMI. \ (Always set to value of N392 for Release 1.1. \ This object has temporarily been assigned read-only \ access. Read-write access will be assigned when \ other values are supported.) ; CAPABILITIES = ; |
| INT nvmFrMgtVCSigNetT392 | 1.3.6.1.4.1.335.1.4.8.1.5.1.5 | INTEGER | read-write | NAME = ; DESC = The value of this object identifies \ the Network-side T392 polling verification \ timer value for this UNI logical port \ (nT2 for LMI). (Configuration); HELP = This value is in seconds. \ If the logical port is not performing\ network-side procedures, \ then this value is equal to noSuchName. \ This object applies to Q.933 Annex A, \ T1.617 Annex D, and LMI; CAPABILITIES = ; |
| INT nvmFrMgtVCSigProced | 1.3.6.1.4.1.335.1.4.8.1.5.1.2 | INTEGER | read-only | NAME = ; DESC = The value of this object identifies \ the Local In-Channel Signaling Procedure \ that is used for this UNI logical \ port. (Configuration); HELP = The UNI logical port can \ be performing only user-to-network \ network-side procedures. \ Always u2nnet(1) for Release 1.1. \ This object has temporarily been assigned read-only \ access. Read-write access will be assigned when \ other enumeration values are supported. ; CAPABILITIES = ; |
| nvmFrMgtVCSigTable | 1.3.6.1.4.1.335.1.4.8.1.5 | not-accessible | NAME = ; DESC = The Frame Relay Management VC \ Signaling Parameters and Errors table. (Configuration); HELP = ; CAPABILITIES = NET_CFG, VPN_CFG; | |
| INT nvmFrPVCEndptDLCIIndex | 1.3.6.1.4.1.335.1.4.8.1.6.1.2 | INTEGER | read-only | NAME = ; DESC = The value of this object is equal to the \ DLCI value for this PVC end-point. (Configuration); HELP = ; CAPABILITIES = ; |
| nvmFrPVCEndptEntry | 1.3.6.1.4.1.335.1.4.8.1.6.1 | not-accessible | NAME = ; DESC = An entry in the Frame Relay PVC End-point \ table. (Configuration); HELP = ; CAPABILITIES = ; | |
| INT nvmFrPVCEndptIfIndex | 1.3.6.1.4.1.335.1.4.8.1.6.1.1 | INTEGER | read-only | NAME = ; DESC = The ifIndex of the local DCE interface. \ (Configuration); HELP = (Analogous to the ifIndex pointer in the \ MIB II Interfaces Group but specific to \ the PVC end-point table.); CAPABILITIES = ; |
| INT nvmFrPVCEndptInBc | 1.3.6.1.4.1.335.1.4.8.1.6.1.4 | INTEGER | read-only | NAME = ; DESC = The committed burst size (Bc) in bits \ for this PVC end-point data sent into \ frame relay network. (Configuration); HELP = This object has temporarily \ been assigned read-only access. Read-write \ access may be assigned in future \ releases.; CAPABILITIES = ; |
| INT nvmFrPVCEndptInBe | 1.3.6.1.4.1.335.1.4.8.1.6.1.5 | INTEGER | read-write | NAME = ; DESC = The committed excess size (Be) in bits \ for this PVC end-point data sent into \ frame relay network. (Configuration); HELP = ; CAPABILITIES = ; |
| INT nvmFrPVCEndptInCIR | 1.3.6.1.4.1.335.1.4.8.1.6.1.6 | INTEGER | read-write | NAME = ; DESC = The committed information rate (CIR) in bits/sec \ for this PVC end-point data sent into \ frame relay network.(Configuration); HELP = ; CAPABILITIES = ; |
| INT nvmFrPVCEndptInMaxFrameSize | 1.3.6.1.4.1.335.1.4.8.1.6.1.3 | INTEGER | read-write | NAME = ; DESC = The largest frame relay information field \ in octets for this PVC end-point data sent \ into the network. (Configuration); HELP = The value must be \ less than or equal to the corresponding \ ifMtu (nvmFrPhyPortMtuSize) for this \ Frame Relay UNI logical port.; CAPABILITIES = ; |
| INT nvmFrPVCEndptOutBc | 1.3.6.1.4.1.335.1.4.8.1.6.1.8 | INTEGER | read-only | NAME = ; DESC = The committed burst size (Bc) in bits \ for this PVC end-point data received from \ frame relay network. (Configuration); HELP = This object has temporarily \ been assigned read-only access. Read-write \ access may be assigned in future \ releases.; CAPABILITIES = ; |
| INT nvmFrPVCEndptOutBe | 1.3.6.1.4.1.335.1.4.8.1.6.1.9 | INTEGER | read-write | NAME = ; DESC = The committed excess size (Be) in bits \ for this PVC end-point data received from \ frame relay network. (Configuration); HELP = ; CAPABILITIES = ; |
| INT nvmFrPVCEndptOutCIR | 1.3.6.1.4.1.335.1.4.8.1.6.1.10 | INTEGER | read-write | NAME = ; DESC = The committed information rate (CIR) in bits/sec \ for this PVC end-point data received from \ frame relay network. (Configuration); HELP = ; CAPABILITIES = ; |
| INT nvmFrPVCEndptOutMaxFrameSize | 1.3.6.1.4.1.335.1.4.8.1.6.1.7 | INTEGER | read-write | NAME = ; DESC = The largest frame relay information field \ in octets for this PVC end-point data received \ from the network. (Configuration); HELP = The value must be \ less than or equal to the corresponding \ ifMtu (nvmFrPhyPortMtuSize) for this \ Frame Relay UNI logical port.; CAPABILITIES = ; |
| nvmFrPVCEndptTable | 1.3.6.1.4.1.335.1.4.8.1.6 | not-accessible | NAME = ; DESC = The Frame Relay PVC End-Point table. \ This table is used to model a PVC \ end-point. (Configuration); HELP = This table contains the \ traffic parameters and statistics for \ a PVC end-point.; CAPABILITIES = NET_CFG, VPN_CFG; | |
| rfc1604_configuration | 1.3.6.1.4.1.335.1.4.8.1 | |||
| rfc1604_control | 1.3.6.1.4.1.335.1.4.8.2 |
RFC description
Provides MICOM gateway and router management functions based on RFC 1604 remote access protocols.
Start monitoring MICOM frame relay access equipment (RFC 1604 DTE extension) with a free 30-day trial of IPNetwork Monitor. Import MIBs, browse SNMP OIDs, create custom SNMP monitors, configure alerts, and monitor any SNMP-enabled network device from a single console.