LIEBERT-GP-FLEXIBLE-MIB :: lgpFlexibleEntryValue

MIB Reference — IPNetwork Monitor · Updated October 06, 2026

All MIBs › LIEBERT-GP-FLEXIBLE-MIB › lgpFlexibleEntryValue

lgpFlexibleEntryValue

Module: LIEBERT-GP-FLEXIBLE-MIB

OID (symbolic): LIEBERT-GP-FLEXIBLE-MIB::lgpFlexibleEntryValue

OID (numeric): 1.3.6.1.4.1.476.1.42.3.9.20.1.20

Node type: OBJECT-TYPE

Type: DisplayString

Access: read-write

Description: A string representation of any data available. This is the preferred method of data access, since this will give fully scaled data for both integer and floating point data, in addition to textual data. If this string column cannot be used, then columns in the lgpFlexibleExtendedTable must be used in order to get a fully scaled version of integer data.

What is lgpFlexibleEntryValue?

This read-write DisplayString holds the fully scaled string representation of a flexible data point's current value or setpoint, covering integer, floating-point, and textual data uniformly. Admins prefer reading and writing this column over the separate integer columns in the extended table because it already accounts for decimal scaling and units, making it directly human-readable. For example, an admin could read lgpFlexibleEntryValue as '72.5' for a temperature sensor row, or write '75.0' to it to change a writable setpoint, without needing to consult the decimal-position column.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.476.1.42.3.9.20.1.20
snmpwalk -v2c -c public <target> LIEBERT-GP-FLEXIBLE-MIB::lgpFlexibleEntryValue

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.476.1.42.3.9.20.1.20.1
snmpget -v2c -c public <target> LIEBERT-GP-FLEXIBLE-MIB::lgpFlexibleEntryValue.1

Set instance 1 (SNMPv2c):

snmpset -v2c -c private <target> 1.3.6.1.4.1.476.1.42.3.9.20.1.20.1 s <value>

Start monitoring Liebert/Vertiv UPS or precision cooling unit (flexible generic object tables) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the LIEBERT-GP-FLEXIBLE-MIB::lgpFlexibleEntryValue OID value, configure state conditions and alerts, and monitor any Liebert/Vertiv UPS or precision cooling unit (flexible generic object tables) from a single console.

OID Breakdown

Upper-level ancestors (11 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.476emersonLIEBERT-GP-REGISTRATION-MIB
1.3.6.1.4.1.476.1liebertCorpLIEBERT-GP-REGISTRATION-MIB
1.3.6.1.4.1.476.1.42liebertGlobalProductsLIEBERT-GP-REGISTRATION-MIB
1.3.6.1.4.1.476.1.42.3lgpFoundationLIEBERT-GP-REGISTRATION-MIB
1.3.6.1.4.1.476.1.42.3.9lgpFlexibleLIEBERT-GP-REGISTRATION-MIB
Numeric OIDNameModule
1.3.6.1.4.1.476.1.42.3.9.20lgpFlexibleBasicTableLIEBERT-GP-FLEXIBLE-MIB
1.3.6.1.4.1.476.1.42.3.9.20.1lgpFlexibleBasicEntryLIEBERT-GP-FLEXIBLE-MIB
1.3.6.1.4.1.476.1.42.3.9.20.1.20lgpFlexibleEntryValueLIEBERT-GP-FLEXIBLE-MIB