HUAWEI-TRANSPARENTBRIDGE-MIB

MIB Reference — IPNetwork Monitor · Updated October 05, 2026

All MIBs › HUAWEI-TRANSPARENTBRIDGE-MIB

Organization: Huawei Technologies Co.,Ltd.

Last Updated: 2015-05-08

Category: Technology: Switching/L2, VLAN and Bridging, Vendor: Huawei

Description: Huawei transparent bridging MIB for managing MAC forwarding tables, bridge ports, and Ethernet bridging configuration.

Start monitoring vendor-neutral, standards-based MIB, any SNMPv3-capable network device (SNMP engine identity/boot/clock status) with a free 30-day trial of IPNetwork Monitor. Import MIBs, browse SNMP OIDs, create custom SNMP monitors, configure alerts, and monitor any SNMP-enabled network device from a single console.

What Is HUAWEI-TRANSPARENTBRIDGE-MIB?

HUAWEI-TRANSPARENTBRIDGE-MIB is a Huawei enterprise MIB for managing transparent bridging functionality on Huawei network devices, i.e., Layer 2 forwarding of frames between ports without routing. It exposes configuration and status data organized under objects such as hwTPBridgeMngObjects, hwTPBridgeBase, and hwTPBridgeApply, covering bridge base settings and the application of bridging policy to specific ports or interfaces. Its monitoring value is in confirming that bridge instances and their port associations are correctly configured and operationally active, which is essential software-level visibility for diagnosing unexpected Layer 2 forwarding behavior. It complements standard bridge MIBs (e.g., BRIDGE-MIB) that report the underlying forwarding-table entries, adding Huawei-specific management objects on top. Deployment context is Huawei switches or routers used to bridge legacy or mixed-media network segments transparently. Network engineers evaluating or troubleshooting this functionality can download the HUAWEI-TRANSPARENTBRIDGE-MIB file directly to load it into their MIB browser.

IPNetwork Monitor allows you to monitor SNMP objects defined in HUAWEI-TRANSPARENTBRIDGE-MIB. Use the built-in SNMP Monitoring Browser to explore available variables, view their current values and descriptions, and select the objects you want to monitor. You can then create SNMP monitors, configure thresholds, and receive alerts when monitored values change.

Supported Devices

  • Huawei switch
  • Huawei router with bridging support

Monitoring Examples

An administrator would examine hwTPBridgeBase settings and hwTPBridgeApply entries to confirm a given port is correctly enabled for transparent bridging, and an unexpected disabled or misapplied entry under hwTPBridgeApply would explain why traffic is not being bridged between two interfaces as expected.

What Can Be Monitored

  • transparent bridge base configuration
  • bridge port application status
  • bridging management objects
Imported Objects

From HUAWEI-BASE-TRAP-MIB

hwBaseTrapEventTypeOBJECT-TYPE
hwBaseTrapProbableCauseOBJECT-TYPE
hwBaseTrapSeverityOBJECT-TYPE

From HUAWEI-MIB

hwDatacommOBJECT-IDENTITY

From IF-MIB

InterfaceIndex
ifIndexOBJECT-TYPE

From P-BRIDGE-MIB

EnabledStatus

From SNMPv2-CONF

MODULE-COMPLIANCE
NOTIFICATION-GROUP
OBJECT-GROUP

From SNMPv2-SMI

Counter64
Gauge32
Integer32
IpAddress
MODULE-IDENTITY
NOTIFICATION-TYPE
OBJECT-IDENTITY
OBJECT-TYPE
TimeTicks

From SNMPv2-TC

MacAddress
RowStatus
TEXTUAL-CONVENTION

How to Use in IPNetwork Monitor

Example using hwTPBridgeStatInTotalPkts OID:

Select a Huawei switch or router with bridging support (transparent bridging) as the target host to create a monitor — the SNMP service should be up and running on it. Click New Monitor, then check SNMP Custom on the Favorites tab, click Next, and confirm the host. On the next page, click Select... to open the built-in SNMP MIB Browser and type hwTPBridgeStatInTotalPkts into the Find box to locate it in the OID tree, selecting the specific row/instance you want to monitor since this is a table column, then select it and click OK. The number of received packets. On the monitor's Main parameters page you can set the target's SNMP port (default 161), credentials, polling interval, and other settings — see the SNMP Monitor help for details. On the State conditions and Alerting tabs, configure when the monitor should change state and trigger an alert; since this is a Counter64-type OID, Value bounds is the most useful condition here — trigger an alert if the counter increases sharply between polls relative to its normal baseline, since an unexpected spike often reflects a real change in traffic or activity. Click Finish to create the monitor; you can adjust any parameter later.
OIDs

RFC description

Huawei MIB module that defines managed objects for transparent bridging functionality in Huawei network devices, used for SNMP-based management and monitoring.

Start monitoring Huawei switch or router with bridging support (transparent bridging) with a free 30-day trial of IPNetwork Monitor. Import MIBs, browse SNMP OIDs, create custom SNMP monitors, configure alerts, and monitor any SNMP-enabled network device from a single console.

Download HUAWEI-TRANSPARENTBRIDGE-MIB