| OID symbolic | OID numeric | Type | Access | Description |
| hwMplsOam | 1.3.6.1.4.1.2011.5.12.7 | | | The HUAWEI-MPLSOAM-MIB contains objects to configure OAM module.
The Operation, Administration and Maintenance (OAM)
is an effective means for decreasing the cost of network maintenance.
The MPLS OAM is used to administrate and maintain MPLS. |
| hwMplsOamPs | 1.3.6.1.4.1.2011.5.12.7.1 | | | |
| hwMplsPsObjects | 1.3.6.1.4.1.2011.5.12.7.1.3 | | | |
| hwMplsPsTable | 1.3.6.1.4.1.2011.5.12.7.1.3.1 | | not-accessible | This table specifies per-protection-group MPLS PS
capability and associated information. |
| hwMplsPsEntry | 1.3.6.1.4.1.2011.5.12.7.1.3.1.1 | | not-accessible | An entry in this table is created by an LSR for every
protection group capable of supporting mpls ps. |
| U32 hwMplsPsIndex | 1.3.6.1.4.1.2011.5.12.7.1.3.1.1.1 | Unsigned32 | read-only | This is a unique index for an entry in the mplspsEntry. |
| I32 hwMplsPsType | 1.3.6.1.4.1.2011.5.12.7.1.3.1.1.2 | Integer32 | read-only | The type of protection switch,can be 1:1,1+1,shared mesh,
packet 1+1,the default choice is 1:1.
In the 1+1 architecture type, a protection LSP is dedicated to
each working LSP with the working LSP bridged onto the
protection LSP at the source of the protection domain.
The traffic on working and protection LSPs is transmitted
simultaneously to the sink of the protection domain,
where a selection between the working and protection LSP is
made, based on some predetermined criteria, such as defect
indication.
In the 1:1 architecture type, a protection LSP is dedicated to
each working LSP. The working traffic is transmitted either by
working or protection LSP.
In the shared mesh architecture type, possible sharing of
protection capacity between disjoint link, node in the network
is achieved while guaranteeing recovery from a single failure.
In the packet 1+1 architecture type, the traffic is transmitted
simultaneously onto two possibly disjoint routed LSPs to the
sink of the protection domain. Each pair of duplicate
transmitted packets is assigned the same identifier (sequence
number) but distinct from the other pairs of duplicate packets.
At the sink of the protection domain packet level selection
mechanism is employed to select one of the two possibly
received copies of each packet.
1: 1:1 protection switching,;
2: 1+1 protection switching;
3: shared mesh protection swiching;
4: packet 1+1 protection switching. |
| OCT hwMplsPsWorkTunnName | 1.3.6.1.4.1.2011.5.12.7.1.3.1.1.3 | OCTET STRING | read-only | The name of work-tunnel. |
| I32 hwMplsPsWorkTunnId | 1.3.6.1.4.1.2011.5.12.7.1.3.1.1.4 | Integer32 | read-only | Work-tunnel id(session-tunnel-id). |
| OCT hwMplsPsProtectTunnName | 1.3.6.1.4.1.2011.5.12.7.1.3.1.1.5 | OCTET STRING | read-only | The name of protect-tunnel. |
| I32 hwMplsPsProtectTunnId | 1.3.6.1.4.1.2011.5.12.7.1.3.1.1.6 | Integer32 | read-only | Protect-tunnel id(session-tunnel-id). |
| I32 hwMplsPsRevertiveMode | 1.3.6.1.4.1.2011.5.12.7.1.3.1.1.7 | Integer32 | read-only | Revertive mode is a protection switching mode where revertive
action (switch back to the working LSP) is taken after the
working LSP is repaired.And switching does not occur in a
non-revertive mode.
1: revertive;
2: non-revertive; |
| I32 hwMplsPsWTR | 1.3.6.1.4.1.2011.5.12.7.1.3.1.1.8 | Integer32 | read-only | Wait to Restore timer is only applicable for the revertive mode
and applies to a working LSP,It prevents reversion back to
select the working LSP until the Wait to Restore timer has
expired.The default value is 12 minutes.step is 30s. |
| I32 hwMplsPsHoldOff | 1.3.6.1.4.1.2011.5.12.7.1.3.1.1.9 | Integer32 | read-only | The time between declaration of signal degrade or signal fail,
and the initialization of the protection switching algorithm.
step is 100ms.maximum is 10s. |
| I32 hwMplsPsSwitchCondition | 1.3.6.1.4.1.2011.5.12.7.1.3.1.1.10 | Integer32 | read-only | The current switch condition of the protection group.
1: clear,This command clears all of the externally
initiated switch commands listed below;
2: lockout of protection,Fix the selector position on the
working LSP,Prevents the selector from switching to the
protection LSP when it is selecting the working LSP.
Switches the selector from the protection to the working LSP
when it is selecting the protection LSP;
3: forced protection,Switches the selector from the working LSP
to the protection LSP (unless a higher priority switch
request (i.e., LoP) is in effect);
4: signal fail,for 1:1,Signal Fail (SF) is declared when the
source of the protection domain enters the Defect State by
receiving a BDI packet (from the return LSP or out of band).
5: manual switch for working-lsp,Switches the selector from the
working LSP to the protection LSP (unless an equal or higher
priority switch request (i.e., LoP, FS, SF or MS) is in
effect);
6: manual switch for protection-lsp,Switches the selector from
the protection LSP to the working LSP (unless an equal or
higher priority switch request (i.e., LoP, FS, SF or MS) is
in effect).
7: WTR-timer;
8: HoldOff-timer;
9: Others;
The pripority of the commands are:
clear > lockout of protection > force switch > manual switch for working
lsp = manual switch for protection lsp |
| I32 hwMplsPsWorkTunnelState | 1.3.6.1.4.1.2011.5.12.7.1.3.1.1.11 | Integer32 | read-only | The state of working tunnel state in one protection group,
whether it is in detection,
1: it is outof defect
2: it enters defect |
| I32 hwMplsPsProtTunnelState | 1.3.6.1.4.1.2011.5.12.7.1.3.1.1.12 | Integer32 | read-only | The state of protection tunnel state in one protection group,
whether it is in detection,
1: it is outof defect
2: it enters defect |
| I32 hwMplsPsSwitchResult | 1.3.6.1.4.1.2011.5.12.7.1.3.1.1.13 | Integer32 | read-only | Which tunnel is used to transfer the data stream.
1: working-tunnel
2: protection-tunnel |
| I32 hwMplsPsCfgType | 1.3.6.1.4.1.2011.5.12.7.1.3.1.1.14 | Integer32 | read-only | The type of protection switch which is configured.
1: 1:1
2: 1+1
3: shared mesh
4: packet 1:1 |
| I32 hwMplsPsCfgProtectTunnId | 1.3.6.1.4.1.2011.5.12.7.1.3.1.1.15 | Integer32 | read-only | Protect-tunnel id(session-tunnel-id). |
| I32 hwMplsPsCfgRevertiveMode | 1.3.6.1.4.1.2011.5.12.7.1.3.1.1.16 | Integer32 | read-only | Revertive mode is a protection switching mode where revertive
action (switch back to the working LSP) is taken after the
working LSP is repaired.And switching does not occur in a
non-revertive mode.
1: revertive;
2: non-revertive; |
| I32 hwMplsPsCfgWTR | 1.3.6.1.4.1.2011.5.12.7.1.3.1.1.17 | Integer32 | read-only | Wait to Restore timer is only applicable for the revertive mode
and applies to a working LSP,It prevents reversion back to
select the working LSP until the Wait to Restore timer has
expired.The default value is 12 minutes.step is 30s. |
| I32 hwMplsPsCfgHoldOff | 1.3.6.1.4.1.2011.5.12.7.1.3.1.1.18 | Integer32 | read-only | The time between declaration of signal degrade or signal fail,
and the initialization of the protection switching algorithm.
step is 100ms.maximum is 10s. |
| ROW hwMplsPsRowStatus | 1.3.6.1.4.1.2011.5.12.7.1.3.1.1.19 | RowStatus | read-only | This variable is used to create, modify, and
delete a row in this table.
1: active
2: not in service
3: not ready
4: create and go
5: create and wait
6: destroy |
| U32 hwTunnPsTrapOpen | 1.3.6.1.4.1.2011.5.12.7.1.3.2 | Unsigned32 | read-only | 1:enable;
2:disable; |
| hwMplsVCPsTable | 1.3.6.1.4.1.2011.5.12.7.1.3.3 | | not-accessible | Description. |
| hwMplsVCPsEntry | 1.3.6.1.4.1.2011.5.12.7.1.3.3.1 | | not-accessible | this table for these commands
1.mpls te protection tunnel XXX
2. mpls te reverse-lsp { lsp-name XXXX | lsr-id X.X.X.X tunnel-id x }
3. mpls te reserved-for-binding |
| NUM hwMplsVCPsIfIndex | 1.3.6.1.4.1.2011.5.12.7.1.3.3.1.1 | InterfaceIndex | read-only | Description.the index of working tunnel interface of Protection group |
| T/F hwMplsVCPsTNLBinding | 1.3.6.1.4.1.2011.5.12.7.1.3.3.1.2 | TruthValue | read-create | Description.it is used by command ' mpls te reserved-for-binding ' |
| OCT hwMplsTeReverseLspName | 1.3.6.1.4.1.2011.5.12.7.1.3.3.1.3 | OCTET STRING | read-create | Description.it is used for command ' mpls te reverse-lsp lspname' |
| ROW hwMplsVcPsRowStatus | 1.3.6.1.4.1.2011.5.12.7.1.3.3.1.4 | RowStatus | read-create | Description.
1: active;
2: notInservice;
3: notReady;
4: CreateAndGo;
5: CreateAndWait;
6: destroy; |
| IP hwMplsTeReverseLspLsrId | 1.3.6.1.4.1.2011.5.12.7.1.3.3.1.5 | IpAddress | read-create | Description.it is used for command ' mpls te reverse-lsp lsr-id X.X.X.X tunnel-id XX' |
| I32 hwMplsTeReverseLspTunnId | 1.3.6.1.4.1.2011.5.12.7.1.3.3.1.6 | Integer32 | read-create | Description.it is used for command ' mpls te reverse-lsp lsr-id X.X.X.X tunnel-id XX' |
| INT hwMplsApsMismatchReason | 1.3.6.1.4.1.2011.5.12.7.1.3.4 | INTEGER | accessible-for-notify | Indicates the alarm reason as below:
1. Bridge type mismatch, one side is 1:1 (Selector Bridge) protection,
the other side is 1+1 (Permanent Bridge) protection;
2. Channel type mismatch, one side has APS channel, the other side has no APS channel;
3. Switching type mismatch, one side is bidirectional switching,
the other side is unidirectional switching;
4. Operation type mismatch, one side is revertive operation,
the other side is non-revertive operation;
5. Traffic request mismatch, one side selects working connection,
the other side selects protection connection; |
| hwMplsPsNotifications | 1.3.6.1.4.1.2011.5.12.7.1.4 | | | |
| NTF hwMplsPsSwitchPtoW | 1.3.6.1.4.1.2011.5.12.7.1.4.1 | | | This notification is generated when switching from
protection-lsp to working-lsp occured. |
| NTF hwMplsPsSwitchWtoP | 1.3.6.1.4.1.2011.5.12.7.1.4.2 | | | This notification is generated when switching from woking-lsp
to protection-lsp occured. |
| NTF hwMplsApsMismatch | 1.3.6.1.4.1.2011.5.12.7.1.4.3 | | | Trap information indicates fully incompatible provisioning and
working/protection configuration mismatch are detected by APS frame. |
| NTF hwMplsApsMismatchRecovery | 1.3.6.1.4.1.2011.5.12.7.1.4.4 | | | Trap information indicates fully incompatible provisioning and
working/protection configuration mismatch recovery are detected by APS frame. |
| NTF hwMplsApsLost | 1.3.6.1.4.1.2011.5.12.7.1.4.5 | | | Tunnel protection group did not receive APS frames from protection tunnel. |
| NTF hwMplsApsLostRecovery | 1.3.6.1.4.1.2011.5.12.7.1.4.6 | | | Tunnel protection group received APS frames from protection tunnel. |
| hwMplsOamPsConformance | 1.3.6.1.4.1.2011.5.12.7.1.100 | | | |
| hwMplsOamPsCompliances | 1.3.6.1.4.1.2011.5.12.7.1.100.1 | | | |
| hwMplsOamPsGroupCompliance | 1.3.6.1.4.1.2011.5.12.7.1.100.1.1 | | | The compliance statement for mpls oam ps. |
| hwMplsOamPsGroups | 1.3.6.1.4.1.2011.5.12.7.1.100.2 | | | |
| hwMplsPsGroup | 1.3.6.1.4.1.2011.5.12.7.1.100.2.1 | | | The compliance statement for mpls oam ps management. |
| hwMplsVcPsGroup | 1.3.6.1.4.1.2011.5.12.7.1.100.2.2 | | | The compliance statement for mpls oam ps reverse lsp. |
| hwMplsPsNotificationGroup | 1.3.6.1.4.1.2011.5.12.7.1.100.2.3 | | | Description. |