All MIBs › H3C-VODIGITALIF-MIB
Organization: Huawei-3COM Technologies Co., Ltd.
Last Updated: 2005-03-15
Category: Domain: VoIP/Telephony, Vendor: H3C/HH3C
Description: H3C MIB for voice digital interface management configuring E1/T1 and PRI/BRI ports on H3C voice gateways.
Start monitoring vendor-neutral, standards-based MIB, any SNMPv3-capable network device (SNMP engine identity/boot/clock status) with a free 30-day trial of IPNetwork Monitor. Import MIBs, browse SNMP OIDs, create custom SNMP monitors, configure alerts, and monitor any SNMP-enabled network device from a single console.
What Is H3C-VODIGITALIF-MIB?
H3C-VODIGITALIF-MIB provides configuration objects for digital voice interfaces on H3C voice gateway equipment, covering digital telephony trunk interfaces such as E1/T1 and ISDN PRI/BRI ports used to connect the gateway to the PSTN or a PBX. No sample object names were extracted for this module, so specific table/object structure can't be confirmed, but based on its description it models per-port digital voice interface configuration. As a voice-gateway interface MIB, its relevant monitoring role is hardware/interface status — such as line/port operational state and configuration parameters for the digital trunk — though the specific counters (e.g., alarm or signaling status) can't be confirmed without visible objects. It likely complements standard voice/telephony MIBs and the standard IF-MIB for interface indexing, though this can't be confirmed without object names. It would be deployed on H3C voice gateway products interconnecting IP telephony systems with traditional E1/T1/PRI/BRI trunks. Network engineers evaluating or troubleshooting this functionality can download the H3C-VODIGITALIF-MIB file directly to load it into their MIB browser.
IPNetwork Monitor allows you to monitor SNMP objects defined in H3C-VODIGITALIF-MIB. Use the built-in SNMP Monitoring Browser to explore available variables, view their current values and descriptions, and select the objects you want to monitor. You can then create SNMP monitors, configure thresholds, and receive alerts when monitored values change.
Supported Devices
- H3C voice gateways
Monitoring Examples
No sample objects were provided for this module, so specific table or object names cannot be confirmed; based on the description, an administrator would typically monitor the configuration and line state of an E1/T1 or PRI/BRI digital voice port to confirm the trunk is provisioned and synchronized correctly, watching for a loss-of-signal or alarm condition indicating a physical PSTN/PBX trunk problem.
What Can Be Monitored
- E1/T1 digital port configuration
- PRI/BRI interface configuration
- digital voice interface operational status
This MIB depends on
Related MIBs
Imported Objects
From HUAWEI-3COM-OID-MIB
| h3cVoice | OBJECT-IDENTITY |
From SNMPv2-SMI
| Integer32 | |
| MODULE-IDENTITY | |
| OBJECT-TYPE |
OIDs
| OID symbolic | OID numeric | Type | Access | Description |
|---|---|---|---|---|
| h3cVoiceDigitalInterface | 1.3.6.1.4.1.2011.10.2.39.4 | The MIB file is to provide the definition of the general digital voice interface configuration. | ||
| h3cVoDigitalIfCommonObjects | 1.3.6.1.4.1.2011.10.2.39.4.1 | |||
| h3cVoDigitalIfCommonCfgTable | 1.3.6.1.4.1.2011.10.2.39.4.1.1 | not-accessible | This table contains the information about configurable parameters for a digital voice interface. | |
| h3cVoDigitalIfCommonCfgEntry | 1.3.6.1.4.1.2011.10.2.39.4.1.1.1 | not-accessible | The entry of h3cVoDigitalIfCommonCfgTable, which is automatically created when a digital voice module has been found. | |
| I32 h3cVoDIfCfgPort | 1.3.6.1.4.1.2011.10.2.39.4.1.1.1.1 | Integer32 | not-accessible | This object indicates the port of a voice digital module. |
| I32 h3cVoDIfCfgGroup | 1.3.6.1.4.1.2011.10.2.39.4.1.1.1.2 | Integer32 | not-accessible | This object indicates the group number of a voice digital module. |
| INT h3cVoDIfCfgBoardType | 1.3.6.1.4.1.2011.10.2.39.4.1.1.1.3 | INTEGER | read-only | This object indicates the type of board. |
| INT h3cVoDIfCfgSignalType | 1.3.6.1.4.1.2011.10.2.39.4.1.1.1.4 | INTEGER | read-only | This object indicates the signal type of a group. |
| OCT h3cVoDIfCfgTsInformation | 1.3.6.1.4.1.2011.10.2.39.4.1.1.1.5 | OCTET STRING | read-only | This object indicates the availability of every single timeslot for voice services. '1' indicates the timeslot is available for voice services. '0' indicates the timeslot is not available for voice services. |
| OCT h3cVoDIfCfgPortSubLine | 1.3.6.1.4.1.2011.10.2.39.4.1.1.1.6 | OCTET STRING | read-only | This object indicates the port subscriber line name. |
| h3cVoDigitalIfEMObjects | 1.3.6.1.4.1.2011.10.2.39.4.2 | |||
| h3cVoDigitalIfEMCfgTable | 1.3.6.1.4.1.2011.10.2.39.4.2.1 | not-accessible | This table contains the information about configurable parameters for a digital EM voice interface. | |
| h3cVoDigitalIfEMCfgEntry | 1.3.6.1.4.1.2011.10.2.39.4.2.1.1 | not-accessible | The entry of h3cVoDigitalIfEMCfgTable. | |
| I32 h3cVoDIfEMCfgPort | 1.3.6.1.4.1.2011.10.2.39.4.2.1.1.1 | Integer32 | not-accessible | This object indicates the port of a voice digital module. |
| I32 h3cVoDIfEMCfgGroup | 1.3.6.1.4.1.2011.10.2.39.4.2.1.1.2 | Integer32 | not-accessible | This object indicates the group number of a voice digital module. |
| I32 h3cVoDIfEMCfgTimeoutInterDigit | 1.3.6.1.4.1.2011.10.2.39.4.2.1.1.3 | Integer32 | read-write | The maximum seconds, to wait for two DTMF (Dual Tone Multi-Frequency) number. |
| I32 h3cVoDIfEMCfgTimeoutRinging | 1.3.6.1.4.1.2011.10.2.39.4.2.1.1.4 | Integer32 | read-write | The maximum seconds, to wait for the ring back on the EM interface. |
| I32 h3cVoDIfEMCfgTimeoutWaitDigit | 1.3.6.1.4.1.2011.10.2.39.4.2.1.1.5 | Integer32 | read-write | The maximum seconds, to wait for called number of called side. |
| OCT h3cVoDIfEMCfgPortSubLine | 1.3.6.1.4.1.2011.10.2.39.4.2.1.1.6 | OCTET STRING | read-only | This object indicates the port subscriber line name. |
| h3cVoDigitalIfEMABCDCfgTable | 1.3.6.1.4.1.2011.10.2.39.4.2.2 | not-accessible | This table contains the information about ABCD bits parameters for a digital EM voice interface. | |
| h3cVoDigitalIfEMABCDCfgEntry | 1.3.6.1.4.1.2011.10.2.39.4.2.2.1 | not-accessible | The entry of h3cVoDigitalIfEMABCDCfgTable. | |
| I32 h3cVoDIfEMABCDCfgPort | 1.3.6.1.4.1.2011.10.2.39.4.2.2.1.1 | Integer32 | not-accessible | This object indicates the port of a voice digital module. |
| I32 h3cVoDIfEMABCDCfgGroup | 1.3.6.1.4.1.2011.10.2.39.4.2.2.1.2 | Integer32 | not-accessible | This object indicates the group number of a voice digital module. |
| OCT h3cVoDIfEMABCDRxIdle | 1.3.6.1.4.1.2011.10.2.39.4.2.2.1.3 | OCTET STRING | read-write | This object indicates the ABCD bits of receiving idle signal. |
| OCT h3cVoDIfEMABCDRxSeizure | 1.3.6.1.4.1.2011.10.2.39.4.2.2.1.4 | OCTET STRING | read-write | This object indicates the ABCD bits of receiving seizure signal. |
| OCT h3cVoDIfEMABCDTxIdle | 1.3.6.1.4.1.2011.10.2.39.4.2.2.1.5 | OCTET STRING | read-write | This object indicates the ABCD bits of sending idle signal. |
| OCT h3cVoDIfEMABCDTxSeizure | 1.3.6.1.4.1.2011.10.2.39.4.2.2.1.6 | OCTET STRING | read-write | This object indicates the ABCD bits of sending seizure signal. |
| OCT h3cVoDIFEMABCDSubLine | 1.3.6.1.4.1.2011.10.2.39.4.2.2.1.7 | OCTET STRING | read-only | This object indicates the port subscriber line name. |
| h3cVoDigitalIfEMTimerTable | 1.3.6.1.4.1.2011.10.2.39.4.2.4 | not-accessible | This table contains the timer parameters for a digital EM voice interface. | |
| h3cVoDigitalIfEMTimerEntry | 1.3.6.1.4.1.2011.10.2.39.4.2.4.1 | not-accessible | The entry of h3cVoDigitalIfEMTimerTable. | |
| I32 h3cVoDIfEMTimerPort | 1.3.6.1.4.1.2011.10.2.39.4.2.4.1.1 | Integer32 | not-accessible | This object indicates the port of a voice digital module. |
| I32 h3cVoDIfEMTimerGroup | 1.3.6.1.4.1.2011.10.2.39.4.2.4.1.2 | Integer32 | not-accessible | This object indicates the group number of a voice digital module. |
| I32 h3cVoDIfEMTimerSendWink | 1.3.6.1.4.1.2011.10.2.39.4.2.4.1.4 | Integer32 | read-write | This object indicates the maximum time in milliseconds between receiving seizure signal and sending wink signal. This object can only take effect when h3cVoDIfCfgSignalType is set to 'emWinkStart'. |
| I32 h3cVoDIfEMTimerWinkRising | 1.3.6.1.4.1.2011.10.2.39.4.2.4.1.5 | Integer32 | read-write | This object indicates the maximum time in milliseconds between sending seizure signal and receiving wink signal. This object can only take effect when h3cVoDIfCfgSignalType is set to 'emWinkStart'. |
| I32 h3cVoDIfEMTimerWinkHold | 1.3.6.1.4.1.2011.10.2.39.4.2.4.1.6 | Integer32 | read-write | This object indicates the maximum duration in milliseconds for sending wink signal. This object can only take effect when h3cVoDIfCfgSignalType is set to 'emWinkStart'. |
| I32 h3cVoDIfEMTimerDialoutDelay | 1.3.6.1.4.1.2011.10.2.39.4.2.4.1.7 | Integer32 | read-write | This object indicates the maximum duration in milliseconds for sending called digits. This object can only take effect when h3cVoDIfCfgSignalType is set to 'emImmediateStart'. |
| I32 h3cVoDIfEMTimerDelayRising | 1.3.6.1.4.1.2011.10.2.39.4.2.4.1.8 | Integer32 | read-write | This object indicates the maximum duration in milliseconds between receiveing seizure signal and sending delay signal. This object can only take effect when h3cVoDIfCfgSignalType is set to 'emDelayStart'. |
| I32 h3cVoDIfEMTimerDelayHold | 1.3.6.1.4.1.2011.10.2.39.4.2.4.1.9 | Integer32 | read-write | This object indicates the maximum duration in milliseconds for sending delay signal. This object can only take effect when h3cVoDIfCfgSignalType is set to 'emDelayStart'. |
| I32 h3cVoDIfEMTimerDtmf | 1.3.6.1.4.1.2011.10.2.39.4.2.4.1.10 | Integer32 | read-write | This object indicates DTMF sending duration in milliseconds. |
| I32 h3cVoDIfEMTimerDtmfInterval | 1.3.6.1.4.1.2011.10.2.39.4.2.4.1.11 | Integer32 | read-write | This object indicates DTMF sending interval in milliseconds. |
| OCT h3cVoDIfEMTimerPortSubLine | 1.3.6.1.4.1.2011.10.2.39.4.2.4.1.12 | OCTET STRING | read-only | This object indicates the port subscriber line name. |
| h3cVoDigitalIfR2Objects | 1.3.6.1.4.1.2011.10.2.39.4.3 | |||
| h3cVoDigitalIfR2CfgTable | 1.3.6.1.4.1.2011.10.2.39.4.3.1 | not-accessible | This table contains information about general configurable parameters for digital r2 voice interface. | |
| h3cVoDigitalIfR2CfgEntry | 1.3.6.1.4.1.2011.10.2.39.4.3.1.1 | not-accessible | The entry of h3cVoDigitalIfR2CfgTable. | |
| I32 h3cVoDIfR2CfgPort | 1.3.6.1.4.1.2011.10.2.39.4.3.1.1.1 | Integer32 | not-accessible | This object indicates the port of a voice digital module. |
| I32 h3cVoDIfR2CfgGroup | 1.3.6.1.4.1.2011.10.2.39.4.3.1.1.2 | Integer32 | not-accessible | This object indicates the group number of a voice digital module. |
| INT h3cVoDIfR2CfgCountryMode | 1.3.6.1.4.1.2011.10.2.39.4.3.1.1.3 | INTEGER | read-write | This object indicates the value of country mode. |
| INT h3cVoDIfR2CfgSpecialChar | 1.3.6.1.4.1.2011.10.2.39.4.3.1.1.4 | INTEGER | read-write | This object indicates the special character(A,B,C,D,#,*). |
| I32 h3cVoDIfR2CfgSpecialSignal | 1.3.6.1.4.1.2011.10.2.39.4.3.1.1.5 | Integer32 | read-write | This object indicates the signal of special character. |
| INT h3cVoDIfR2CfgSelectMode | 1.3.6.1.4.1.2011.10.2.39.4.3.1.1.6 | INTEGER | read-write | This object indicates the trunk mode to be selected: min set selected trunk mode to min-mode. max set selected trunk mode to max-mode. minpoll set selected trunk mode to min-poll-mode. maxpoll set selected trunk mode to max-poll-mode. |
| OCT h3cVoDIFR2CfgSubLine | 1.3.6.1.4.1.2011.10.2.39.4.3.1.1.7 | OCTET STRING | read-only | This object indicates the port subscriber line name. |
| h3cVoDigitalIfR2ABCDCfgTable | 1.3.6.1.4.1.2011.10.2.39.4.3.2 | not-accessible | This table contains the information about ABCD bits parameters for a digital r2 voice interface. | |
| h3cVoDigitalIfR2ABCDCfgEntry | 1.3.6.1.4.1.2011.10.2.39.4.3.2.1 | not-accessible | The entry of h3cVoDigitalIfR2ABCDCfgTable. | |
| I32 h3cVoDIfR2ABCDCfgPort | 1.3.6.1.4.1.2011.10.2.39.4.3.2.1.1 | Integer32 | not-accessible | This object indicates the port of a voice digital module. |
| I32 h3cVoDIfR2ABCDCfgGroup | 1.3.6.1.4.1.2011.10.2.39.4.3.2.1.2 | Integer32 | not-accessible | This object indicates the group number of a voice digital module. |
| OCT h3cVoDIfR2ABCDReverseABCD | 1.3.6.1.4.1.2011.10.2.39.4.3.2.1.3 | OCTET STRING | read-write | This object indicates whether the ABCD bits should be inverted. '0' : disable invertion. '1' : enable invertion. |
| OCT h3cVoDIfR2ABCDRenewABCD | 1.3.6.1.4.1.2011.10.2.39.4.3.2.1.4 | OCTET STRING | read-write | This object indicates the unused ABCD bits to be sent. |
| OCT h3cVoDIfR2ABCDRxIdle | 1.3.6.1.4.1.2011.10.2.39.4.3.2.1.5 | OCTET STRING | read-write | This object indicates the IDLE line signaling to be received. |
| OCT h3cVoDIfR2ABCDTxIdle | 1.3.6.1.4.1.2011.10.2.39.4.3.2.1.6 | OCTET STRING | read-write | This object indicates the IDLE line signaling to be sent. |
| OCT h3cVoDIfR2ABCDRxSeizure | 1.3.6.1.4.1.2011.10.2.39.4.3.2.1.7 | OCTET STRING | read-write | This object indicates the SEIZURE line signaling to be received. |
| OCT h3cVoDIfR2ABCDTxSeizure | 1.3.6.1.4.1.2011.10.2.39.4.3.2.1.8 | OCTET STRING | read-write | This object indicates the SEIZURE line signaling to be sent. |
| OCT h3cVoDIfR2ABCDRxSeizureAck | 1.3.6.1.4.1.2011.10.2.39.4.3.2.1.9 | OCTET STRING | read-write | This object indicates the SEIZURE_ACK line signaling to be received. |
| OCT h3cVoDIfR2ABCDTxSeizureAck | 1.3.6.1.4.1.2011.10.2.39.4.3.2.1.10 | OCTET STRING | read-write | This object indicates the SEIZURE_ACK line signaling to be sent. |
| OCT h3cVoDIfR2ABCDRxAnswer | 1.3.6.1.4.1.2011.10.2.39.4.3.2.1.11 | OCTET STRING | read-write | This object indicates the ANSWER line signaling to be received. |
| OCT h3cVoDIfR2ABCDTxAnswer | 1.3.6.1.4.1.2011.10.2.39.4.3.2.1.12 | OCTET STRING | read-write | This object indicates the ANSWER line signaling to be sent. |
| OCT h3cVoDIfR2ABCDRxClearForward | 1.3.6.1.4.1.2011.10.2.39.4.3.2.1.13 | OCTET STRING | read-write | This object indicates the CLEAR_FORWARD line signaling to be received. |
| OCT h3cVoDIfR2ABCDTxClearForward | 1.3.6.1.4.1.2011.10.2.39.4.3.2.1.14 | OCTET STRING | read-write | This object indicates the CLEAR_FORWARD line signaling to be sent. |
| OCT h3cVoDIfR2ABCDRxClearBack | 1.3.6.1.4.1.2011.10.2.39.4.3.2.1.15 | OCTET STRING | read-write | This object indicates the CLEAR_BACKWARD line signaling to be received. |
| OCT h3cVoDIfR2ABCDTxClearBack | 1.3.6.1.4.1.2011.10.2.39.4.3.2.1.16 | OCTET STRING | read-write | This object indicates the CLEAR_BACKWARD line signaling to be sent. |
| OCT h3cVoDIfR2ABCDRxReleaseGuard | 1.3.6.1.4.1.2011.10.2.39.4.3.2.1.17 | OCTET STRING | read-write | This object indicates the RELEASE_GUARD line signaling to be received. |
| OCT h3cVoDIfR2ABCDTxReleaseGuard | 1.3.6.1.4.1.2011.10.2.39.4.3.2.1.18 | OCTET STRING | read-write | This object indicates the RELEASE_GUARD line signaling to be sent. |
| OCT h3cVoDIfR2ABCDRxBlocking | 1.3.6.1.4.1.2011.10.2.39.4.3.2.1.19 | OCTET STRING | read-write | This object indicates the BLOCKING line signaling to be received. |
| OCT h3cVoDIfR2ABCDTxBlocking | 1.3.6.1.4.1.2011.10.2.39.4.3.2.1.20 | OCTET STRING | read-write | This object indicates the BLOCKING line signaling to be sent. |
| OCT h3cVoDIfR2ABCDSubLine | 1.3.6.1.4.1.2011.10.2.39.4.3.2.1.21 | OCTET STRING | read-only | This object indicates the port subscriber line name. |
| h3cVoDigitalIfR2MfcCfgTable | 1.3.6.1.4.1.2011.10.2.39.4.3.3 | not-accessible | This table contains information about MFC(Multi-Frequency Control) configurable parameters for digital r2 voice interface. | |
| h3cVoDigitalIfR2MfcCfgEntry | 1.3.6.1.4.1.2011.10.2.39.4.3.3.1 | not-accessible | The entry of h3cVoDigitalIfR2MfcCfgTable. | |
| I32 h3cVoDIfR2MfcCfgPort | 1.3.6.1.4.1.2011.10.2.39.4.3.3.1.1 | Integer32 | not-accessible | This object indicates the port of a voice digital module. |
| I32 h3cVoDIfR2MfcCfgGroup | 1.3.6.1.4.1.2011.10.2.39.4.3.3.1.2 | Integer32 | not-accessible | This object indicates the group number of a voice digital module. |
| I32 h3cVoDIfR2BillingCategory | 1.3.6.1.4.1.2011.10.2.39.4.3.3.1.3 | Integer32 | read-write | This object indicates the value of BILLING CATEGORY during the MFC procedure. |
| I32 h3cVoDIfR2CallingCategory | 1.3.6.1.4.1.2011.10.2.39.4.3.3.1.4 | Integer32 | read-write | This object indicates the value of CALLING CATEGORY during the MFC procedure. |
| I32 h3cVoDIfR2Congestion | 1.3.6.1.4.1.2011.10.2.39.4.3.3.1.5 | Integer32 | read-write | This object indicates the value of CONGESTION during the MFC procedure. |
| I32 h3cVoDIfR2DemandRefused | 1.3.6.1.4.1.2011.10.2.39.4.3.3.1.6 | Integer32 | read-write | This object indicates the value of DEMAND REFUSED during the MFC procedure. |
| I32 h3cVoDIfR2DigitEnd | 1.3.6.1.4.1.2011.10.2.39.4.3.3.1.7 | Integer32 | read-write | This object indicates the value of DIGIT END during the MFC procedure. |
| I32 h3cVoDIfR2Nullnum | 1.3.6.1.4.1.2011.10.2.39.4.3.3.1.8 | Integer32 | read-write | This object indicates the value of NULL NUMBER during the MFC procedure. |
| I32 h3cVoDIfR2ReqBillingCategory | 1.3.6.1.4.1.2011.10.2.39.4.3.3.1.9 | Integer32 | read-write | This object indicates the value of REQUESTING BILLING category during the MFC procedure. |
| I32 h3cVoDIfR2ReqCallingCategory | 1.3.6.1.4.1.2011.10.2.39.4.3.3.1.10 | Integer32 | read-write | This object indicates the value of REQUESTING CALLING CATEGORY during the MFC procedure. |
| I32 h3cVoDIfR2ReqCurrentdigit | 1.3.6.1.4.1.2011.10.2.39.4.3.3.1.11 | Integer32 | read-write | This object indicates the value of REQUESTING CURRENT DIGIT during the MFC procedure. |
| I32 h3cVoDIfR2ReqFirstCallingnum | 1.3.6.1.4.1.2011.10.2.39.4.3.3.1.12 | Integer32 | read-write | This object indicates the value of REQUESTING FIRST CALLING NUMBER during the MFC procedure. |
| I32 h3cVoDIfR2ReqFirstDigit | 1.3.6.1.4.1.2011.10.2.39.4.3.3.1.13 | Integer32 | read-write | This object indicates the value of REQUESTING FIRST DIGIT during the MFC procedure. |
| I32 h3cVoDIfR2ReqNextCallednum | 1.3.6.1.4.1.2011.10.2.39.4.3.3.1.14 | Integer32 | read-write | This object indicates the value of REQUESTING NEXT CALLED NUMBER during the MFC procedure. |
| I32 h3cVoDIfR2ReqNextCallingnum | 1.3.6.1.4.1.2011.10.2.39.4.3.3.1.15 | Integer32 | read-write | This object indicates the value of REQUESTING NEXT CALLING NUMBER during the MFC procedure. |
| I32 h3cVoDIfR2ReqLastFirstDigit | 1.3.6.1.4.1.2011.10.2.39.4.3.3.1.16 | Integer32 | read-write | This object indicates the value of REQUESTING LAST FIRST DIGIT during the MFC procedure. |
| I32 h3cVoDIfR2ReqLastSecondDigit | 1.3.6.1.4.1.2011.10.2.39.4.3.3.1.17 | Integer32 | read-write | This object indicates the value of REQUESTING LAST SECOND DIIGT during the MFC procedure. |
| I32 h3cVoDIfR2ReqLastThirdDigit | 1.3.6.1.4.1.2011.10.2.39.4.3.3.1.18 | Integer32 | read-write | This object indicates the value of REQUESTING LAST LAST THIRD DIGIT during the MFC procedure. |
| I32 h3cVoDIfR2ReqSwitchGroupB | 1.3.6.1.4.1.2011.10.2.39.4.3.3.1.19 | Integer32 | read-write | This object indicates the value of REQUESTING SWITCH GROUP B during the MFC procedure. |
| I32 h3cVoDIfR2SubscriberIdle | 1.3.6.1.4.1.2011.10.2.39.4.3.3.1.20 | Integer32 | read-write | This object indicates the value of SUSCRIBER IDLE during the MFC procedure. |
| I32 h3cVoDIfR2SubscriberBusy | 1.3.6.1.4.1.2011.10.2.39.4.3.3.1.21 | Integer32 | read-write | This object indicates the value of SUBSCRIBER BUSY. |
| I32 h3cVoDIfR2ReqCallingnumOffset | 1.3.6.1.4.1.2011.10.2.39.4.3.3.1.22 | Integer32 | read-write | This object indicates the value of CALLING NUMBER OFFSET during the MFC procedure. |
| I32 h3cVoDIfR2CallCreateInA | 1.3.6.1.4.1.2011.10.2.39.4.3.3.1.23 | Integer32 | read-write | This object indicates the value of CALLCREATE IN GROUP A during the MFC procedure. |
| I32 h3cVoDIfR2ReqFirstCalledNumInC | 1.3.6.1.4.1.2011.10.2.39.4.3.3.1.24 | Integer32 | read-write | This object indicates the value of FIRST CALLED NUMBER IN GROUP C during the MFC procedure. |
| I32 h3cVoDIfR2ReqCurCalledNumInC | 1.3.6.1.4.1.2011.10.2.39.4.3.3.1.25 | Integer32 | read-write | This object indicates the value of CURRENT CALLED NUMBER IN GROUP C during the MFC procedure. |
| I32 h3cVoDIfR2ReqCalledNumSwitchA | 1.3.6.1.4.1.2011.10.2.39.4.3.3.1.26 | Integer32 | read-write | This object indicates the value of REQUEST CALLED NUMBER AND SWITCH TO GROUP A during the MFC procedure. |
| I32 h3cVoDIfR2ReqSpecialSignal | 1.3.6.1.4.1.2011.10.2.39.4.3.3.1.27 | Integer32 | read-write | This object indicates the value of SPECIAL SIGNAL during the MFC procedure. |
| I32 h3cVoDIfR2SubscriberCharge | 1.3.6.1.4.1.2011.10.2.39.4.3.3.1.28 | Integer32 | read-write | This object indicates the value of SUBSCRIBER CHARGE during the MFC procedure. |
| I32 h3cVoDIfR2SubscriberAbnormal | 1.3.6.1.4.1.2011.10.2.39.4.3.3.1.29 | Integer32 | read-write | This object indicates the value of SUBSCRIBER ABNORMAL during the MFC procedure. |
| INT h3cVoDIfR2Ani | 1.3.6.1.4.1.2011.10.2.39.4.3.3.1.30 | INTEGER | read-write | This object indicates whether to return the calling category and the call number during the MFC procedure. |
| OCT h3cVoDIfR2SubLine | 1.3.6.1.4.1.2011.10.2.39.4.3.3.1.31 | OCTET STRING | read-only | This object indicates the port subscriber line name. |
| h3cVoDigitalIfR2TimerCfgTable | 1.3.6.1.4.1.2011.10.2.39.4.3.4 | not-accessible | This table contains information about time parameters for digital r2 voice interface. | |
| h3cVoDigitalIfR2TimerCfgEntry | 1.3.6.1.4.1.2011.10.2.39.4.3.4.1 | not-accessible | The entry of h3cVoDigitalIfR2TimeCfgTable. | |
| I32 h3cVoDIfR2TimeCfgPort | 1.3.6.1.4.1.2011.10.2.39.4.3.4.1.1 | Integer32 | not-accessible | This object indicates the port of a voice digital module. |
| I32 h3cVoDIfR2TimeCfgGroup | 1.3.6.1.4.1.2011.10.2.39.4.3.4.1.2 | Integer32 | not-accessible | This object indicates the group number of a voice digital module. |
| I32 h3cVoDIfR2CfgDebounceTime | 1.3.6.1.4.1.2011.10.2.39.4.3.4.1.3 | Integer32 | read-write | This object indicates the minimum duration which is the line signal going to persist. |
| I32 h3cVoDIfR2CfgSendringBackTime | 1.3.6.1.4.1.2011.10.2.39.4.3.4.1.4 | Integer32 | read-write | This object indicates the minimum duration which is the ring back going to persist. |
| I32 h3cVoDIfR2CfgSendringBusyTime | 1.3.6.1.4.1.2011.10.2.39.4.3.4.1.5 | Integer32 | read-write | This object indicates the minimum duration which is the ring busy going to persist. |
| I32 h3cVoDIfR2PulseSignalPersistT | 1.3.6.1.4.1.2011.10.2.39.4.3.4.1.6 | Integer32 | read-write | This object indicates the value of pulse signal persistence timer. |
| I32 h3cVoDIfR2CfgDlAnswerTime | 1.3.6.1.4.1.2011.10.2.39.4.3.4.1.7 | Integer32 | read-write | This object indicates the value of answer timer. |
| I32 h3cVoDIfR2CfgDlClearBackTime | 1.3.6.1.4.1.2011.10.2.39.4.3.4.1.8 | Integer32 | read-write | This object indicates the value of clear back timer. |
| I32 h3cVoDIfR2CfgDlClearForwardT | 1.3.6.1.4.1.2011.10.2.39.4.3.4.1.9 | Integer32 | read-write | This object indicates the value of clear forward timer. |
| I32 h3cVoDIfR2CfgDlSeizureTime | 1.3.6.1.4.1.2011.10.2.39.4.3.4.1.10 | Integer32 | read-write | This object indicates the value of seizure timer. |
| I32 h3cVoDIfR2CfgDlReanswerTime | 1.3.6.1.4.1.2011.10.2.39.4.3.4.1.11 | Integer32 | read-write | This object indicates the value of reanswer timer. |
| I32 h3cVoDIfR2CfgDlRelGuardTime | 1.3.6.1.4.1.2011.10.2.39.4.3.4.1.12 | Integer32 | read-write | This object indicates the value of release guard timer. |
| I32 h3cVoDIfR2CfgMfcGroupBTime | 1.3.6.1.4.1.2011.10.2.39.4.3.4.1.13 | Integer32 | read-write | This object indicates the value of group B timer. |
| I32 h3cVoDIfR2CfgDTMFTime | 1.3.6.1.4.1.2011.10.2.39.4.3.4.1.14 | Integer32 | read-write | This object indicates the value of DTMF(Dual Tone Multi-Frequency) timer. |
| OCT h3cVoDIfR2TimeCfgSubLine | 1.3.6.1.4.1.2011.10.2.39.4.3.4.1.15 | OCTET STRING | read-only | This object indicates the port subscriber line name. |
| h3cVoDIfR2CapabilityCfgTable | 1.3.6.1.4.1.2011.10.2.39.4.3.5 | not-accessible | This table contains information about capability parameters for digital r2 voice interface. | |
| h3cVoDIfR2CapabilityCfgEntry | 1.3.6.1.4.1.2011.10.2.39.4.3.5.1 | not-accessible | The entry of h3cVoDIfR2CapabilityCfgTable. | |
| I32 h3cVoDIfR2CapCfgPort | 1.3.6.1.4.1.2011.10.2.39.4.3.5.1.1 | Integer32 | not-accessible | This object indicates the port of a voice digital module. |
| I32 h3cVoDIfR2CapCfgGroup | 1.3.6.1.4.1.2011.10.2.39.4.3.5.1.2 | Integer32 | not-accessible | This object indicates the group number of a voice digital module. |
| INT h3cVoDIfR2CfgGroupB | 1.3.6.1.4.1.2011.10.2.39.4.3.5.1.3 | INTEGER | read-write | This object indicates whether the group B process is enabled. |
| INT h3cVoDIfR2CfgClearForwardAck | 1.3.6.1.4.1.2011.10.2.39.4.3.5.1.4 | INTEGER | read-write | This object indicates whether the CLEAR_FORWARD_ACK signal is enabled. |
| INT h3cVoDIfR2CfgDlSeizureAck | 1.3.6.1.4.1.2011.10.2.39.4.3.5.1.5 | INTEGER | read-write | This object indicates whether the SEIZURE_ACK signal is enabled. |
| INT h3cVoDIfR2CfgDTMF | 1.3.6.1.4.1.2011.10.2.39.4.3.5.1.6 | INTEGER | read-write | This object indicates whether the DTMF(Dual Tone Multi-Frequency) is enabled. |
| INT h3cVoDIfR2CfgAnswer | 1.3.6.1.4.1.2011.10.2.39.4.3.5.1.7 | INTEGER | read-write | This object indicates whether the ANSWER signal is enabled. |
| INT h3cVoDIfR2CfgReanswer | 1.3.6.1.4.1.2011.10.2.39.4.3.5.1.8 | INTEGER | read-write | This object indicates whether the REANSWER signal is enabled. |
| INT h3cVoDIfR2CfgFinalCallnum | 1.3.6.1.4.1.2011.10.2.39.4.3.5.1.9 | INTEGER | read-write | This object indicates whether the FINAL_CALL_NUMBER signal is enabled. |
| INT h3cVoDIfR2CfgForceMetering | 1.3.6.1.4.1.2011.10.2.39.4.3.5.1.10 | INTEGER | read-write | This object indicates whether the METERING signal is enabled. |
| INT h3cVoDIfR2CfgSendRingBack | 1.3.6.1.4.1.2011.10.2.39.4.3.5.1.11 | INTEGER | read-write | This object indicates whether to send the ring back tone. |
| INT h3cVoDIfR2CfgSendRingBusy | 1.3.6.1.4.1.2011.10.2.39.4.3.5.1.12 | INTEGER | read-write | This object indicates whether to send the busy tone. |
| OCT h3cVoDIfR2CapCfgSubLine | 1.3.6.1.4.1.2011.10.2.39.4.3.5.1.15 | OCTET STRING | read-only | This object indicates the port subscriber line name. |
RFC description
Configuration management for digital voice interface modules on Huawei 3Com voice equipment.
Start monitoring H3C voice gateway (digital E1/T1/ISDN voice interface config) with a free 30-day trial of IPNetwork Monitor. Import MIBs, browse SNMP OIDs, create custom SNMP monitors, configure alerts, and monitor any SNMP-enabled network device from a single console.