OID (symbolic): H3C-STORAGE-MIB::h3cServerPowerState
OID (numeric): 1.3.6.1.4.1.2011.10.10.1.1.1.3.4
Node type: OBJECT-TYPE
Type: INTEGER
Access: read-only
Description: This object identifies the state of power supply in the server, and is valid when UPS has been configured successful. The value 'online' means power supply is well-balanced. The value 'onlinebypass' means supply power without ups. The value 'onbattery' means supply power with battery. The value 'unknown' means the power supply state is unknown.
What is h3cServerPowerState?
Reports the server's power source when a UPS is configured: online(1) means normal balanced power, onlinebypass(2) means power is supplied without going through the UPS, onbattery(3) means it's running on battery, and unknown(4) means the state can't be determined -- an admin watches this to catch a utility power loss before the battery runs out.
Examples
Walk all instances (SNMPv2c):
snmpwalk -v2c -c public <target> 1.3.6.1.4.1.2011.10.10.1.1.1.3.4 snmpwalk -v2c -c public <target> H3C-STORAGE-MIB::h3cServerPowerState
Get a specific instance (index 1):
snmpget -v2c -c public <target> 1.3.6.1.4.1.2011.10.10.1.1.1.3.4.1 snmpget -v2c -c public <target> H3C-STORAGE-MIB::h3cServerPowerState.1
SNMPv3 example:
snmpget -v3 -l authPriv -u snmpv3-user -a SHA -A "AuthPassword1" -x AES -X "PrivPassword1" <target> h3cServerPowerState.1
Start monitoring H3C storage platform (RAID/FC/NAS capability and control) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the H3C-STORAGE-MIB::h3cServerPowerState OID value, configure state conditions and alerts, and monitor any H3C storage platform (RAID/FC/NAS capability and control) from a single console.
OID Breakdown
Upper-level ancestors (9 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.4 | private | AirPair-MIB |
| 1.3.6.1.4.1 | enterprises | AirPair-MIB |
| 1.3.6.1.4.1.2011 | huawei | EXPERTV2-MIB |
| 1.3.6.1.4.1.2011.10 | h3c | HUAWEI-3COM-OID-MIB |
| 1.3.6.1.4.1.2011.10.10 | h3cStorageRef | H3C-STORAGE-REF-MIB |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.2011.10.10.1 | h3cStorageMIB | H3C-STORAGE-MIB |
| 1.3.6.1.4.1.2011.10.10.1.1 | h3cStorageMibObjects | H3C-STORAGE-MIB |
| 1.3.6.1.4.1.2011.10.10.1.1.1 | h3cStorageServerInfo | H3C-STORAGE-MIB |
| 1.3.6.1.4.1.2011.10.10.1.1.1.3 | h3cStorageServerPhysInfo | H3C-STORAGE-MIB |
| 1.3.6.1.4.1.2011.10.10.1.1.1.3.4 | h3cServerPowerState | H3C-STORAGE-MIB |