H3C-STORAGE-MIB :: h3cExtCriticalVoltageLowThreshold

MIB Reference — IPNetwork Monitor · Updated October 05, 2026

All MIBs › H3C-STORAGE-MIB › h3cExtCriticalVoltageLowThreshold

h3cExtCriticalVoltageLowThreshold

Module: H3C-STORAGE-MIB

OID (symbolic): H3C-STORAGE-MIB::h3cExtCriticalVoltageLowThreshold

OID (numeric): 1.3.6.1.4.1.2011.10.10.1.1.2.5.1.6

Node type: OBJECT-TYPE

Type: Integer32

Access: read-write

Description: The critical low threshold for voltage. If the voltage is lower too much than the entity needs, the entity will halt.

What is h3cExtCriticalVoltageLowThreshold?

Sets a more severe low-voltage threshold below h3cExtVoltageLowThreshold; crossing it means the voltage is low enough that the entity will halt if it drops further, so an admin treats a breach here as urgent.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.2011.10.10.1.1.2.5.1.6
snmpwalk -v2c -c public <target> H3C-STORAGE-MIB::h3cExtCriticalVoltageLowThreshold

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.2011.10.10.1.1.2.5.1.6.1
snmpget -v2c -c public <target> H3C-STORAGE-MIB::h3cExtCriticalVoltageLowThreshold.1

Set instance 1 (SNMPv2c):

snmpset -v2c -c private <target> 1.3.6.1.4.1.2011.10.10.1.1.2.5.1.6.1 i <value>

Start monitoring H3C storage platform (RAID/FC/NAS capability and control) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the H3C-STORAGE-MIB::h3cExtCriticalVoltageLowThreshold OID value, configure state conditions and alerts, and monitor any H3C storage platform (RAID/FC/NAS capability and control) from a single console.

OID Breakdown

Upper-level ancestors (9 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.2011huaweiEXPERTV2-MIB
1.3.6.1.4.1.2011.10h3cHUAWEI-3COM-OID-MIB
1.3.6.1.4.1.2011.10.10h3cStorageRefH3C-STORAGE-REF-MIB
Numeric OIDNameModule
1.3.6.1.4.1.2011.10.10.1h3cStorageMIBH3C-STORAGE-MIB
1.3.6.1.4.1.2011.10.10.1.1h3cStorageMibObjectsH3C-STORAGE-MIB
1.3.6.1.4.1.2011.10.10.1.1.2h3cStoragePhysicalInfoH3C-STORAGE-MIB
1.3.6.1.4.1.2011.10.10.1.1.2.5h3cExtVoltageTableH3C-STORAGE-MIB
1.3.6.1.4.1.2011.10.10.1.1.2.5.1h3cExtVoltageEntryH3C-STORAGE-MIB
1.3.6.1.4.1.2011.10.10.1.1.2.5.1.6h3cExtCriticalVoltageLowThresholdH3C-STORAGE-MIB