H3C-NVGRE-MIB

MIB Reference — IPNetwork Monitor · Updated October 05, 2026

All MIBs › H3C-NVGRE-MIB

Organization: Hangzhou H3C Technologies Co., Ltd.

Last Updated: 2014-03-11

Category: VPN and Security, Vendor: H3C/HH3C

Description: H3C MIB for NVGRE (Network Virtualization using GRE) managing virtual network overlays in data center environments.

Start monitoring vendor-neutral, standards-based MIB, any SNMPv3-capable network device (SNMP engine identity/boot/clock status) with a free 30-day trial of IPNetwork Monitor. Import MIBs, browse SNMP OIDs, create custom SNMP monitors, configure alerts, and monitor any SNMP-enabled network device from a single console.

What Is H3C-NVGRE-MIB?

H3C-NVGRE-MIB is an H3C-specific MIB for managing Network Virtualization using Generic Routing Encapsulation (NVGRE), a data-center overlay technology that tunnels virtual-machine traffic across a physical underlay network using a Virtual Subnet Identifier. It exposes a table of configured NVGRE virtual networks (ID, associated VSI, remote MAC count, row status) and a separate tunnel table tracking each NVGRE tunnel's identifier and status. As a monitoring MIB it is used for software/overlay-network state visibility rather than physical hardware health: operators check whether expected NVGRE segments and tunnels are configured and active (row status) and watch h3cNvgreRemoteMacCount to gauge how many remote MAC addresses have been learned over a given virtual network, which can reveal underlay connectivity or MAC-learning problems. It logically depends on the device's VSI/bridge-domain and tunnel-interface infrastructure, though no formal MIB import is stated. It is typically deployed on H3C data-center switches/routers acting as NVGRE tunnel endpoints in virtualized, multi-tenant cloud network fabrics. Engineers can download the H3C-NVGRE-MIB file directly to load it into their MIB browser.

IPNetwork Monitor allows you to monitor SNMP objects defined in H3C-NVGRE-MIB. Use the built-in SNMP Monitoring Browser to explore available variables, view their current values and descriptions, and select the objects you want to monitor. You can then create SNMP monitors, configure thresholds, and receive alerts when monitored values change.

Supported Devices

  • H3C data-center switches/routers (NVGRE tunnel endpoints)

Monitoring Examples

Polling h3cNvgreTable / h3cNvgreEntry indexed by h3cNvgreID shows h3cNvgreVsiIndex, h3cNvgreRemoteMacCount, and h3cNvgreRowStatus for each configured virtual network, letting an admin confirm the segment is active and check whether expected remote MACs have been learned. h3cNvgreTunnelTable / h3cNvgreTunnelEntry (h3cNvgreTunnelID, h3cNvgreTunnelRowStatus) shows whether the underlying NVGRE tunnel to a remote endpoint is up. h3cNvgreNextNvgreID and h3cNvgreConfigured give the next available ID and overall configuration state for the NVGRE feature.

What Can Be Monitored

  • configured NVGRE virtual network IDs and status
  • VSI association per NVGRE network
  • remote MAC learning count
  • tunnel status per NVGRE tunnel
  • NVGRE feature configuration state
Imported Objects

From HUAWEI-3COM-OID-MIB

h3cCommonOBJECT-IDENTITY

From SNMPv2-SMI

Counter64
MODULE-IDENTITY
OBJECT-TYPE
Unsigned32

From SNMPv2-TC

MacAddress
RowStatus

How to Use in IPNetwork Monitor

Example using h3cNvgreTunnelOctets OID:

Select an H3C data-center switch/router (NVGRE tunnel endpoints) as the target host to create a monitor — the SNMP service should be up and running on it. Click New Monitor, then check SNMP Custom on the Favorites tab, click Next, and confirm the host. On the next page, click Select... to open the built-in SNMP MIB Browser and type h3cNvgreTunnelOctets into the Find box to locate it in the OID tree, selecting the specific row/instance you want to monitor since this is a table column, then select it and click OK. The number of octets that have been forwarded over the tunnel. On the monitor's Main parameters page you can set the target's SNMP port (default 161), credentials, polling interval, and other settings — see the SNMP Monitor help for details. On the State conditions and Alerting tabs, configure when the monitor should change state and trigger an alert; since this is a Counter64-type OID, Value bounds is the most useful condition here — trigger an alert if the counter increases sharply between polls relative to its normal baseline, since an unexpected spike often reflects a real change in traffic or activity. Click Finish to create the monitor; you can adjust any parameter later.
OIDs

RFC description

Vendor-private MIB for H3C/Huawei devices; defines NVGRE (Network Virtualization using Generic Routing Encapsulation) management objects.

Start monitoring H3C data-center switch/router (NVGRE tunnel endpoints) with a free 30-day trial of IPNetwork Monitor. Import MIBs, browse SNMP OIDs, create custom SNMP monitors, configure alerts, and monitor any SNMP-enabled network device from a single console.

Download H3C-NVGRE-MIB