All MIBs › F3-CFM-MIB › cfmMepSlmEnabled
cfmMepSlmEnabled
Module: F3-CFM-MIB
OID (symbolic): F3-CFM-MIB::cfmMepSlmEnabled
OID (numeric): 1.3.6.1.4.1.2544.1.12.13.1.1.2.1.22
Node type: OBJECT-TYPE
Type: CfmSlmEnabledTypes
Access: read-write
Description: This bit mask indicates the whether SLM is enabled per each COS.
What is cfmMepSlmEnabled?
This is a bit mask, one bit per CoS (cos0-cos7), controlling whether Synthetic Loss Measurement (SLM) is enabled for each priority class on this MEP. An admin sets specific bits to run SLM only on the CoS classes that need loss measurement, rather than every class.
Examples
Walk all instances (SNMPv2c):
snmpwalk -v2c -c public <target> 1.3.6.1.4.1.2544.1.12.13.1.1.2.1.22 snmpwalk -v2c -c public <target> F3-CFM-MIB::cfmMepSlmEnabled
Get a specific instance (index 1):
snmpget -v2c -c public <target> 1.3.6.1.4.1.2544.1.12.13.1.1.2.1.22.1 snmpget -v2c -c public <target> F3-CFM-MIB::cfmMepSlmEnabled.1
Set instance 1 (SNMPv2c):
snmpset -v2c -c private <target> 1.3.6.1.4.1.2544.1.12.13.1.1.2.1.22.1 s <value>
SNMPv3 example:
snmpget -v3 -l authPriv -u snmpv3-user -a SHA -A "AuthPassword1" -x AES -X "PrivPassword1" <target> cfmMepSlmEnabled.1
Start monitoring ADVA Optical Networking FSP150CM/CC (F3 platform) carrier Ethernet device (802.1ag/Y.1731 Connectivity Fault Management) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the F3-CFM-MIB::cfmMepSlmEnabled OID value, configure state conditions and alerts, and monitor any ADVA Optical Networking FSP150CM/CC (F3 platform) carrier Ethernet device (802.1ag/Y.1731 Connectivity Fault Management) from a single console.
OID Breakdown
Upper-level ancestors (9 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.4 | private | AirPair-MIB |
| 1.3.6.1.4.1 | enterprises | AirPair-MIB |
| 1.3.6.1.4.1.2544 | advaMIB | ADVA-MIB |
| 1.3.6.1.4.1.2544.1 | products | ADVA-MIB |
| 1.3.6.1.4.1.2544.1.12 | fsp150cm | ADVA-MIB |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.2544.1.12.13 | f3CfmMIB | F3-CFM-MIB |
| 1.3.6.1.4.1.2544.1.12.13.1 | cfmExtSvc | F3-CFM-MIB |
| 1.3.6.1.4.1.2544.1.12.13.1.1 | cfmExtSvcObjects | F3-CFM-MIB |
| 1.3.6.1.4.1.2544.1.12.13.1.1.2 | cfmMepTable | F3-CFM-MIB |
| 1.3.6.1.4.1.2544.1.12.13.1.1.2.1 | cfmMepEntry | F3-CFM-MIB |
| 1.3.6.1.4.1.2544.1.12.13.1.1.2.1.22 | cfmMepSlmEnabled | F3-CFM-MIB |