ERICSSON-ALARM-XPATH-MIB :: eriAlarmXActiveOrigAdditionalText

MIB Reference — IPNetwork Monitor · Updated October 02, 2026

All MIBs › ERICSSON-ALARM-XPATH-MIB › eriAlarmXActiveOrigAdditionalText

eriAlarmXActiveOrigAdditionalText

Module: ERICSSON-ALARM-XPATH-MIB

OID (symbolic): ERICSSON-ALARM-XPATH-MIB::eriAlarmXActiveOrigAdditionalText

OID (numeric): 1.3.6.1.4.1.193.183.6.1.3.5.1.13

Node type: OBJECT-TYPE

Type: EriLargeAdditionalText

Access: read-only

Description: A user-friendly text describing the alarm. The text is both static depending on the alarm type (probable cause), and dynamic depending on YANG resource instance and other conditions. This is the original text as reported by the first alarm notification, after which it is not altered.

What is eriAlarmXActiveOrigAdditionalText?

The original human-readable alarm description as first reported, frozen at raise time and never updated afterward, letting an admin compare it against the current eriAlarmXActiveAdditionalText to see if the wording changed as the fault evolved.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.193.183.6.1.3.5.1.13
snmpwalk -v2c -c public <target> ERICSSON-ALARM-XPATH-MIB::eriAlarmXActiveOrigAdditionalText

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.193.183.6.1.3.5.1.13.1
snmpget -v2c -c public <target> ERICSSON-ALARM-XPATH-MIB::eriAlarmXActiveOrigAdditionalText.1

Start monitoring Ericsson telecom network element/element manager (XPath-filterable alarm subscription) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the ERICSSON-ALARM-XPATH-MIB::eriAlarmXActiveOrigAdditionalText OID value, configure state conditions and alerts, and monitor any Ericsson telecom network element/element manager (XPath-filterable alarm subscription) from a single console.

OID Breakdown

Upper-level ancestors (8 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.193ericssonANS-COMMON-MIB
1.3.6.1.4.1.193.183atsAxd301Comm-OMS
Numeric OIDNameModule
1.3.6.1.4.1.193.183.6ericssonAlarmXpathMIBERICSSON-ALARM-XPATH-MIB
1.3.6.1.4.1.193.183.6.1eriAlarmXObjectsERICSSON-ALARM-XPATH-MIB
1.3.6.1.4.1.193.183.6.1.3eriAlarmXActiveAlarmsERICSSON-ALARM-XPATH-MIB
1.3.6.1.4.1.193.183.6.1.3.5eriAlarmXActiveAlarmTableERICSSON-ALARM-XPATH-MIB
1.3.6.1.4.1.193.183.6.1.3.5.1eriAlarmXActiveAlarmEntryERICSSON-ALARM-XPATH-MIB
1.3.6.1.4.1.193.183.6.1.3.5.1.13eriAlarmXActiveOrigAdditionalTextERICSSON-ALARM-XPATH-MIB